Peak seismic response of a symmetric base-isolated steel building: near vs. far fault excitations and varying incident angle

  • Pavlidou, Constantina;Komodromos, Petros
    • Earthquakes and Structures
    • /
    • 제18권3호
    • /
    • pp.349-365
    • /
    • 2020
  • Since the peak seismic response of a base-isolated building strongly depends on the characteristics of the imposed seismic ground motion, the behavior of a base-isolated building under different seismic ground motions is studied, in order to better assess their effects on its peak seismic response. Specifically, the behavior of a typical steel building is examined as base-isolated with elastomeric bearings, while the effect of near-fault ground motions is studied by imposing 7 pairs of near- and 7 pairs of far-fault seismic records, from the same 7 earthquake events, to the building, under 3 different loading combinations, through three-dimensional (3D) nonlinear dynamic analyses, conducted with SAP2000. The results indicate that near-fault seismic components are more likely to increase the building's peak seismic response than the corresponding far-fault components. Furthermore, the direction of the imposed earthquake excitations is also varied by rotating the imposed pairs of seismic records from 0◦ to 360◦, with respect to the major construction axes. It is observed that the peak seismic responses along the critical incident angles, which in general differ from the major horizontal construction axes of the building, are significantly higher. Moreover, the influence of 5% and 10% accidental mass eccentricities is also studied, revealing that when considering accidental mass eccentricities the peak relative displacements of the base isolated building at the isolation level are substantially increased, while the peak floor accelerations and interstory drifts of its superstructure are only slightly affected.

면진구조의 응답가속도 감소효과를 고려한 상부구조의 설계전단력 저감계수 (Design Shear Force Reduction Factor of Upper Structure in Seismic Base-isolated System Considering Response Acceleration Decrement Effect)

  • 천하오;오상훈
    • 대한건축학회논문집:구조계
    • /
    • 제35권7호
    • /
    • pp.165-170
    • /
    • 2019
  • The structural damage caused by earthquake to the upper structure of seismic base-isolated system can be suppressed effectively because it is designed to concentrate the input energy on the seismic isolation floor. Further, the response acceleration of seismic base-isolated system can be greatly reduced compared to the seismic structure because of the long period, which means that the design shear force of the seismic base-isolated system can be reduced appropriately. However, when the design shear force is determined to be reduced, the design stiffness will decrease, and the response acceleration will increase oppositely. Therefore, for finding the extent to which the design shear force of the upper structure can be reduced, this paper considered the seismic base-isolated structure as the analytical model and proposed the design shear force reduction factor of the base-isolated structure through the dynamic response analysis, while considering the decrement effect of response acceleration. The research result shows that the response acceleration of the isolated the upper structure can be reduced by 50%~70% of the seismic structure under the same design conditions, and the design shear force can be reduced by up to 40%. By increasing the design stiffness over to 1.8 times of the original design value, the design shear force can be reduced to the same extent as the response acceleration can be reduced compared to the seismic structure.

아치구조물의 지진응답제어를 위한 스마트 면진시스템의 적용 (Application of Smart Base Isolation System for Seismic Response Control of an Arch Structure)

  • 강주원;김현수
    • 한국전산구조공학회논문집
    • /
    • 제24권2호
    • /
    • pp.157-165
    • /
    • 2011
  • 지진하중이 가해지는 구조물의 동적응답을 줄이기 위해서 면진장치가 널리 사용되고 있다. 근래에 들어서는 면진층의 변위를 증가시키지 않으면서도 면진된 구조물의 동적응답을 효과적으로 줄일 수 있는 스마트 면진시스템에 대한 연구가 활발히 이루어지고 있다. 이에 본 연구에서는 지진하중을 받는 아치구조물의 동적응답을 저감시키기 위하여 스마트 면진시스템을 적용하였고 제어성능을 검토하였다. 스마트 면진시스템을 구성하기 위하여 4kN 용량의 MR 감쇠기와 저감쇠 탄성 고무베어링을 사용하였다. 제안된 스마트 면진시스템의 제어성능을 검토하기 위하여 최적설계된 LRB와 지진응답 제어성능을 비교하였다. 이를 위하여 KBC2009 설계응답스펙트럼에 맞추어 생성한 인공지진파를 지진하중으로 사용하였다. 스마트 면진시스템의 MR 감쇠기를 제어하기 위하여 퍼지제어기를 사용하였으며, 다목적 유전자알고리즘을 이용하여 최적화하였다. 수치해석결과 스마트 면진시스템을 사용하면 LRB를 사용한 경우와 비교하여 면진층 변위와 아치구조물의 지진응답을 크게 줄일 수 있음을 확인하였다.

Seismic isolation performance sensitivity to potential deviations from design values

  • Alhan, Cenk;Hisman, Kemal
    • Smart Structures and Systems
    • /
    • 제18권2호
    • /
    • pp.293-315
    • /
    • 2016
  • Seismic isolation is often used in protecting mission-critical structures including hospitals, data centers, telecommunication buildings, etc. Such structures typically house vibration-sensitive equipment which has to provide continued service but may fail in case sustained accelerations during earthquakes exceed threshold limit values. Thus, peak floor acceleration is one of the two main parameters that control the design of such structures while the other one is peak base displacement since the overall safety of the structure depends on the safety of the isolation system. And in case peak base displacement exceeds the design base displacement during an earthquake, rupture and/or buckling of isolators as well as bumping against stops around the seismic gap may occur. Therefore, obtaining accurate peak floor accelerations and peak base displacement is vital. However, although nominal design values for isolation system and superstructure parameters are calculated in order to meet target peak design base displacement and peak floor accelerations, their actual values may potentially deviate from these nominal design values. In this study, the sensitivity of the seismic performance of structures equipped with linear and nonlinear seismic isolation systems to the aforementioned potential deviations is assessed in the context of a benchmark shear building under different earthquake records with near-fault and far-fault characteristics. The results put forth the degree of sensitivity of peak top floor acceleration and peak base displacement to superstructure parameters including mass, stiffness, and damping and isolation system parameters including stiffness, damping, yield strength, yield displacement, and post-yield to pre-yield stiffness ratio.

Seismic responses of base-isolated nuclear power plant structures considering spatially varying ground motions

  • Sayed, Mohamed A.;Go, Sunghyuk;Cho, Sung Gook;Kim, Dookie
    • Structural Engineering and Mechanics
    • /
    • 제54권1호
    • /
    • pp.169-188
    • /
    • 2015
  • This study presents the effects of the spatial variation of ground motions in a hard rock site on the seismic responses of a base-isolated nuclear power plant (BI-NPP). Three structural models were studied for the BI-NPP supported by different number of lead rubber bearing (LRB) base isolators with different base mat dimensions. The seismic responses of the BI-NPP were analyzed and investigated under the uniform and spatial varying excitation of El Centro ground motion. In addition, the rotational degrees of freedom (DOFs) of the base mat nodes were taken to consider the flexural behavior of the base mat on the seismic responses under both uniform and spatial varying excitation. Finally, the seismic response results for all the analysis cases of the BI-NPP were investigated in terms of the vibration periods and mode shapes, lateral displacements, and base shear forces. The analysis results indicate that: (1) considering the flexural behavior of the base mat has a negligible effect on the lateral displacements of base isolators regardless of the number of the isolators or the type of excitation used; (2) considering the spatial variation of ground motions has a substantial influence on the lateral displacements of base isolators and the NPP stick model; (3) the ground motion spatial variation effect is more prominent on lateral displacements than base shear forces, particularly with increasing numbers of base isolators and neglecting flexural behavior of the base mat.

주파수특성이 다른 입력지진에 대한 면진구조물의 지진응답연구 (Study on Seismic Responses for Base Isolated Structure Subjected to Earthquakes with Different Frequency Characteristics)

  • 유봉;이재한
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1997년도 봄 학술발표회 논문집
    • /
    • pp.224-231
    • /
    • 1997
  • A study on the seismic responses for a base isolated structure subjected to earthquakes with different frequency characteristics is peformed with time history analyses. Two types of seismic inputs are considered in these analyses, one is short period earthquakes such as El Centro(1940, NS), the other is long period ones such as Mexico(1985). The seismic responses of the base isolated structure depend on seismic input types and isolation frequencies. In this study the 0.5 Hz of isolation frequency for short period earthquakes remarkably reduces the acceleration responses, increases the relative displacements of isolator that are still within the proposed limits of isolator. However higher isolation frequency for long period earthquakes is more adequate to reduce the seismic responses of the base isolated structures; in the study 0.75 Hz is effective to Mexico 1985 earthquake.

  • PDF

A PERFORMANCE ASSESSMENT OF A BASE ISOLATION SYSTEM FOR AN EMERGENCY DIESEL GENERATOR IN A NUCLEAR POWER PLANT

  • Choun, Young-Sun;Kim, Min-Kyu
    • Nuclear Engineering and Technology
    • /
    • 제40권4호
    • /
    • pp.285-298
    • /
    • 2008
  • This study evaluates the performance of a coil spring-viscous damper system for the vibration and seismic isolation of an Emergency Diesel Generator (EDG) by measuring its operational vibration and seismic responses. The vibration performance of a coil spring-viscous damper system was evaluated by the vibration measurements for an identical EDG set with different base systems - one with an anchor bolt system and the other with a coil spring-viscous damper system. The seismic performance of the coil spring-viscous damper system was evaluated by seismic tests with a scaled model of a base-isolated EDG on a shaking table. The effects of EDG base isolation on the fragility curve and core damage frequency in a nuclear power plant were also investigated through a case study.

소규모 철골조건축물 강축방향 노출형 주각부의 내진성능 향상을 위한 실험 연구 (Experimental Study on Seismic Performance Enhancement of Exposed Column-base Plate Strong-axis Connections for Small-Sized Steel Buildings)

  • 유영찬
    • 대한건축학회논문집:구조계
    • /
    • 제34권12호
    • /
    • pp.11-20
    • /
    • 2018
  • The purpose of this study is to investigate the seismic performance of exposed column-base plate strong-axis connections for small-sized steel buildings. Even though the seismic design for small-sized buildings became mandatory since Dec.2017, the arbitrary connection details in steel structure have been applied at the construction site, which is considered to be very insufficient to secure structural safety and stability considering the increased seismic risk. Therefore, a series of experimental test programs had been carried out to develop enhanced connection details in order to ensue the adequate seismic safety of small buildings. The hysteretic behavior of the exposed column-base plate connections commonly used in Korea seem to be very pure poor due to the "Rocking" phenomena between anchor plate and concrete by the residual plastic deformation of anchor bolts. A series of hysteretic tests were conducted to find the solution to overcome the "Rocking" phenomena of the exposed column-base plate connections, finally the stable seismic behavior was obtained by uisng at least 8 anchor bolts with good bonding strength to the protptype specimen.

지중구조물 내진설계를 위한 기반면의 속도 응답스펙트럼 및 응답변위 산정기법에 대한 연구 (Evaluations of Velocity Response Spectrum of Seismic Base and Response Displacement for the Seismic Design of Underground Structures)

  • 윤종구;김동수;유제남
    • 한국지반공학회논문집
    • /
    • 제19권4호
    • /
    • pp.211-221
    • /
    • 2003
  • 지중구조물의 내진해석에 자주 이용되는 방법으로 응답변위법이 있다. 응답변위법은 정적인 해석방법으로, 이 방법의 핵심은 지진시 지중구조물 측벽에 작용하는 지반변위를 산정하는 것이다. 이때 해석대상부지의 고유주기에 해당하는 기반면의 속도 응답스펙트럼 값을 결정하는 일이 매우 중요하다. 본 연구에서는 국내 설계지반운동기준에 적합한 기반면의 속도 응답스펙트럼 산정과 지반응답해석 없이 응답변위를 신뢰성있게 산정하는 간편법에 대한 연구를 수행하였다. 해석결과 국내 내진설계 기준의 S$_A$ 지반의 지표면 가속도 응답스펙트럼을 적분하여 속도 응답스펙트럼으로 환산하는 방법과 지반을 두 개의 층으로 구분하여 지진시 지반의 응답변위를 산정하는 방법을 현업 설계에 적용할 경우 경제적으로 큰 잇점이 있을 것으로 판단된다.

Seismic assessment of base-isolated nuclear power plants

  • Farmanbordar, Babak;Adnan, Azlan Bin;Tahir, Mahmood Md.;Faridmehr, Iman
    • Advances in Computational Design
    • /
    • 제2권3호
    • /
    • pp.211-223
    • /
    • 2017
  • This research presented a numerical and experimental study on the seismic performance of first-generation base-isolated and fixed-base nuclear power plants (NPP). Three types of the base isolation system were applied to rehabilitate the first-generation nuclear power plants: frictional pendulum (FP), high-damping rubber (HDR) and lead-rubber (LR) base isolation. Also, an Excel program was proposed for the design of the abovementioned base isolators in accordance with UBC 97 and the Japan Society of Base Isolation Regulation. The seismic assessment was performed using the pushover and nonlinear time history analysis methods in accordance with the FEMA 356 regulation. To validate the adequacy of the proposed design procedure, two small-scale NPPs were constructed at Universiti Teknologi Malaysia's structural laboratory and subjected to a pushover test for two different base conditions, fixed and HDR-isolated base. The results showed that base-isolated structures achieved adequate seismic performance compared with the fixed-base one, and all three isolators led to a significant reduction in the containment's tension, overturning moment and base shear.