• 제목/요약/키워드: segmented cell

검색결과 66건 처리시간 0.029초

잡종견(雜種犬)의 혈액학치(血液學値)에 관(關)한 연구(硏究) (Hematologic values of mixed breed dog in Korea)

  • 유석종;김태종
    • 대한수의학회지
    • /
    • 제30권2호
    • /
    • pp.157-162
    • /
    • 1990
  • The hematologic values were examined from 74 healthy mixed breed dogs in the area of Seoul. The results obtained are summarized as follows; 1. Mean${\pm}$SD values and ranges of red blood cell(RBC) count were $6.16{\pm}0.92{\times}10^6/{\mu}l$ and $4.40{\sim}8.62{\times}10^6/{\mu}l$, of hemoglobin(Hb) content $14.90{\pm}2.42g/100ml$ and 8.7~19.2g/100ml, of packed cell volume(PCV) $45.47{\pm}6.16ml/100ml$ and 30~57ml/100ml, of mean corpuscular volume (MCV) $74.80{\pm}6.83fl$ and 54.08~90.90fl, of mean corpuscular hemoglobin (MCH) $24.41{\pm}3.91pg$ and 14.19~32.97pg, of mean corpuscular hemoglobin concentration (MCHC) $32.07{\pm}3.24g/100ml$ and 22.23~39.76g/100ml, respectively. 2. The RBC count value in the age group of 3~4 years was higher (p<0.05) than the total RBC count value. The Hb content value in the age group of less than 6 months was lower (p<0.01) but in the age group of 1~2 years and the age group of 3~4 years were higher (p<0.05, p<0.01) than the total Hb content value. The PCV value in the age group of less than 6 months was lower (p<0.05) than the total PCV value. The MCHC values in the age group of 1~2 years and the age group of 3~4 years were higher (p<0.01, p<0.05) than the total MCHC value. 3. Mean${\pm}$SD values and ranges of white blood cell (WBC) count were $11.26{\pm}3.05{\times}10^3/{\mu}l$ and $6.30{\sim}18.4{\times}10^3/{\mu}l$, of band neutrophil $2.97{\pm}1.44%$ and 1~10%, of segmented neutrophil $62.81{\pm}4.92%$ and 42~70, of lymphocyte $30.55{\pm}5.69%$ and 17~50%, of monocyte $2.49{\pm}0.84%$ and 1~5%, of eosinophil $1.81{\pm}1.175$ and 1~8%, respectively. 4. The WBC count value in the age group of 7~12 months was lower (p<0.05) but in the age group of 3~4 years was higher (p<0.05) than the total WBC count value. The band neutrophil values in the age group of 1~2 years and the age group of 3~4 years were higher (p<0.05, p<0.01) than the total band neutrophil value.

  • PDF

Self Calibration Current Bias 회로에 의한 10-bit 100 MSPS CMOS D/A 변환기의 설계 (A 10-bit 100 MSPS CMOS D/A Converter with a Self Calibration Current Bias Circuit)

  • 이한수;송원철;송민규
    • 대한전자공학회논문지SD
    • /
    • 제40권11호
    • /
    • pp.83-94
    • /
    • 2003
  • 본 논문에서는 빠른 정착시간을 갖는 전류셀(Current Cell) 매트릭스의 구조와 출력의 Gain error를 보정할 수 있는 Self calibration current bias 회로의 기능을 가진 고성능 10-bit D/A 변환기를 제안한다. 매트릭스 구조 회로의 복잡성으로 인한 지연시간의 증가 및 전력 소모를 최소화하기 위해 상위 6MSB(Most Significant Bit)전류원 매트릭스와 하위 4LSB(Least Significant Bit)전류원 매트릭스로 구성된 2단 매트릭스 구조로 설계되어 있다. 이러한 6+4 분할 구조를 사용함으로써 전류 원이 차지하는 면적과 Thermometer decoder 부분의 논리회로를 가장 최적화 시켜 회로의 복잡성과 Chip 사이즈를 줄일 수 있었고 낮은 Glitch 특성을 갖는 저 전력 D/A 변환기를 구현하였다. 또한 self Calibration이 가능한 Current Bias를 설계함으로서 이전 D/A 변환기들의 칩 외부에 구현하던 Termination 저항을 칩 내부에 구현하고 출력의 선형성 및 정확성을 배가시켰다. 본 연구에서는 3.3V의 공급전압을 가지는 0.35㎛ 2-poly 4-metal N-well CMOS 공정을 사용하였고, 모의 실험결과에서 선형성이 매우 우수한 출력을 확인하였다. 또한 소비전력은 45m W로 다른 10bit D/A 변환기에 비해 매우 낮음을 확인 할 수 있었다. 실제 제작된 칩은 Spectrum analyzer에 의한 측정결과에서 100㎒ 샘플링 클럭 주파수와 10㎒ 입력 신호 주파수에서 SFDR은 약 65㏈로 측정되었고, INL과 DNL은 각각 0.5 LSB 이하로 나타났다. 유효 칩 면적은 Power Guard ring을 포함하여 1350㎛ × 750 ㎛ 의 면적을 갖는다.

10-비트 전류출력형 디지털-아날로그 변환기의 설계 (A Design of 10 bit Current Output Type Digital-to-Analog Converter)

  • 권기협;김태민;신건순
    • 한국정보통신학회논문지
    • /
    • 제9권5호
    • /
    • pp.1073-1081
    • /
    • 2005
  • 본 논문은 상위 7비트와 하위 3비트의 segmented 전류원 구조로서 최적화 된 binary-thermal decoding 방식을 이용한 3.3v 10비트 CMOS D/A 변환기를 제안한다. segmeted 전류원 구조와 최적화 된 binary-thermal decoding 방식을 D/A 변환기가 지니므로 가질 수 있는 장점은 디코딩 논리회로의 복잡성을 단순화함으로 칩면적을 줄일 수 있다. 제안된 변환기는 0.35um CMOS n-well 표준공정을 이용하여 제작되었으며, 유효 칩면적은 $0.953mm^2$ 이다. 설계된 칩의 상승/하강시간, 정작시간 및 INL/DNL은 각각 1.92/2.1 ns, 12.71 ns, ${\pm}2.3/{\pm}0.58$ LSB로 나타났다. 또한 설계된 D/A 변환기는 3.3V의 공급전원에서는 224mW의 전력소모가 측정되었다.

Analysis of Random Variations and Variation-Robust Advanced Device Structures

  • Nam, Hyohyun;Lee, Gyo Sub;Lee, Hyunjae;Park, In Jun;Shin, Changhwan
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제14권1호
    • /
    • pp.8-22
    • /
    • 2014
  • In the past few decades, CMOS logic technologies and devices have been successfully developed with the steady miniaturization of the feature size. At the sub-30-nm CMOS technology nodes, one of the main hurdles for continuously and successfully scaling down CMOS devices is the parametric failure caused by random variations such as line edge roughness (LER), random dopant fluctuation (RDF), and work-function variation (WFV). The characteristics of each random variation source and its effect on advanced device structures such as multigate and ultra-thin-body devices (vs. conventional planar bulk MOSFET) are discussed in detail. Further, suggested are suppression methods for the LER-, RDF-, and WFV-induced threshold voltage (VTH) variations in advanced CMOS logic technologies including the double-patterning and double-etching (2P2E) technique and in advanced device structures including the fully depleted silicon-on-insulator (FD-SOI) MOSFET and FinFET/tri-gate MOSFET at the sub-30-nm nodes. The segmented-channel MOSFET (SegFET) and junctionless transistor (JLT) that can suppress the random variations and the SegFET-/JLT-based static random access memory (SRAM) cell that enhance the read and write margins at a time, though generally with a trade-off between the read and the write margins, are introduced.

Classifying Indian Medicinal Leaf Species Using LCFN-BRNN Model

  • Kiruba, Raji I;Thyagharajan, K.K;Vignesh, T;Kalaiarasi, G
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제15권10호
    • /
    • pp.3708-3728
    • /
    • 2021
  • Indian herbal plants are used in agriculture and in the food, cosmetics, and pharmaceutical industries. Laboratory-based tests are routinely used to identify and classify similar herb species by analyzing their internal cell structures. In this paper, we have applied computer vision techniques to do the same. The original leaf image was preprocessed using the Chan-Vese active contour segmentation algorithm to efface the background from the image by setting the contraction bias as (v) -1 and smoothing factor (µ) as 0.5, and bringing the initial contour close to the image boundary. Thereafter the segmented grayscale image was fed to a leaky capacitance fired neuron model (LCFN), which differentiates between similar herbs by combining different groups of pixels in the leaf image. The LFCN's decay constant (f), decay constant (g) and threshold (h) parameters were empirically assigned as 0.7, 0.6 and h=18 to generate the 1D feature vector. The LCFN time sequence identified the internal leaf structure at different iterations. Our proposed framework was tested against newly collected herbal species of natural images, geometrically variant images in terms of size, orientation and position. The 1D sequence and shape features of aloe, betel, Indian borage, bittergourd, grape, insulin herb, guava, mango, nilavembu, nithiyakalyani, sweet basil and pomegranate were fed into the 5-fold Bayesian regularization neural network (BRNN), K-nearest neighbors (KNN), support vector machine (SVM), and ensemble classifier to obtain the highest classification accuracy of 91.19%.

Negative association between high temperature-humidity index and milk performance and quality in Korean dairy system: big data analysis

  • Dongseok Lee;Daekyum Yoo;Hyeran Kim;Jakyeom Seo
    • Journal of Animal Science and Technology
    • /
    • 제65권3호
    • /
    • pp.588-595
    • /
    • 2023
  • The aim of this study was to investigate the effects of heat stress on milk traits in South Korea using comprehensive data (dairy production and climate). The dataset for this study comprised 1,498,232 test-day records for milk yield, fat- and protein-corrected milk, fat yield, protein yield, milk urea nitrogen (MUN), and somatic cell score (SCS) from 215,276 Holstein cows (primiparous: n = 122,087; multiparous: n = 93,189) in 2,419 South Korean dairy herds. Data were collected from July 2017 to April 2020 through the Dairy Cattle Improvement Program, and merged with meteorological data from 600 automatic weather stations through the Korea Meteorological Administration. The segmented regression model was used to estimate the effects of the temperature-humidity index (THI) on milk traits and elucidate the break point (BP) of the THI. To acquire the least-squares mean of milk traits, the generalized linear model was applied using fixed effects (region, calving year, calving month, parity, days in milk, and THI). For all parameters, the BP of THI was observed; in particular, milk production parameters dramatically decreased after a specific BP of THI (p < 0.05). In contrast, MUN and SCS drastically increased when THI exceeded BP in all cows (p < 0.05) and primiparous cows (p < 0.05), respectively. Dairy cows in South Korea exhibited negative effects on milk traits (decrease in milk performance, increase in MUN, and SCS) when the THI exceeded 70; therefore, detailed feeding management is required to prevent heat stress in dairy cows.

50MHz 2단 온도계 디코더 방식을 사용한 10 bit DAC 설계 (Design and Implement of 50MHz 10 bits DAC based on double step Thermometer Code)

  • 정준희;김영식
    • 대한전자공학회논문지SD
    • /
    • 제49권6호
    • /
    • pp.18-24
    • /
    • 2012
  • 본 논문에서는 $0.18-{\mu}m$ CMOS 공정으로 제작된 무선 센서네트워크 송신기에 적용 가능한 50MHz/s 저전력 10비트 DAC 측정 결과를 제시한다. 제작된 DAC는 일반적 세그멘티드 방식과는 다르게 2단 온도계 디코더를 이용한 전류 구동 방식으로, 10비트를 상위 6비트와 하위 4비트로 나누어 구현하였다. 상위 6 비트의 온도계 디코더는 3비트의 행 디코더와 3비트의 열 디코더로 행과 열을 대칭적으로 구성하여 상위 전류 셀을 제어하였고, 하위 4비트도 온도계 디코더 방식으로 하위 전류셀을 구동하도록 설계하였다. 상위와 하위 단위 전류 셀은 셀 크기를 바꾸는 대신 바이어스 회로에서 하위 단위 전류의 크기가 상위 단위 전류와의 크기에 비해 1/16이 되도록 바이어스 회로를 설계하였다. 그리고 상위와 하위 셀간의 온도계 디코더 신호의 동기를 위해 입력 신호 및 디코딩 된 신호에 모두 동기화 래치를 적용하여 Skew를 최소화하도록 설계하였다. 측정결과 DAC는 50MHz클럭에서 최대 출력구동범위가 2.2Vpp이고, 이 조건에서 DC전원은 3.3 V에서 DC전류 4.3mA를 소모하였다. 그리고 DAC의 선형성 특성은 최대 SFDR이 62.02 dB, 최대 DNL은 0.37 LSB, 최대 INL은 0.67 LSB로 측정되었다.

비소세포성 폐암에서 3차원 입체조형 방사선 치료 성적 (Clinical Experience of Three Dimensional Conformal Radiation Therapy for Non-Small Cell Lung Cancer)

  • 최은경;이병용;강원철;노영주;정원규;안승도;김종훈;장혜숙
    • Radiation Oncology Journal
    • /
    • 제16권3호
    • /
    • pp.265-274
    • /
    • 1998
  • 목적 : 비소세포성 폐암에서 새로운 치료방법으로 대두되고 있는 3차원 입체조형 방사선 치료(Three dimensional conformal radiotherapy, 3DCRT)의 임상적용 가능성과 기존의 치료법에 비한 장점을 찾고자 1994년부터 전향적 연구를 시행하였다. 본 연구는 1) 가장 효과적인 3차원 입체조형 치료 방법의 개발, 2) 가능한 총 치료 선량증가, 3) 선량 증가에 따른 방사선 폐렴 발생 위험군 예측, 4) 선량증가에 따른 국소관해 및 생존율 향상을 목적으로 하였다. 대상 및 방법 : 1996년 12월까지 수술이 불가능하다고 판정된 95명의 환자(stage I: 4명, stage II; 1명, stage IIIa; 14명, stage IIIb; 76명)에 대하여 3차원 입체조형 치료를 시행하였다. 3차원입체조형 치료를 위하여 고정기구를 이용하여 앙와위 혹은 복와위 상태로 자세를 고정한 다음 CT-simulator를 이용하여 5 mm간격으로 CT 영상을 얻고 GTV (Gross Tumor Volume), CTV (Clinical Target Volume), PTV(Planning Target Volume)를 정한 후 3차원 치료계획용 컴퓨터를 이용하여 치료계획을 세웠다. 방사선 치료는 육안적 종양과 림프절을 포함하는 부위에 36-40 Gy를 AP-PA로 치료한 후 25-34 Gy의 3차원 입체조형 치료를 추가조사하여 총 65-70 Gy를 시행하였다. 이중 78명 (82.1$\%$)의 환자는 2회의 MVP (Mitomycin C, Vinblastine, Cisplatin) 복합항암요법을 동시에 시행하였다. 3차원 입체조형 치료 계획은 1) 표적 부위의 3차원 선량분포, 2) DVH (Dose Volume Histogram), 3) NTCP (Normal Tissue Complication Probability)를 이용하여 기존의 2차원 통상 치료 계획과 비교하였다. 결과 : 78명의 환자에서는 4-8 조사영역을 이용하는 비동일 평면 입체조형 치료 (Non-coplanar 3DCRT) 방법을 사용하였으며 17명에서는 Coplanar segmented 3DCRT 방법으로 치료하였다. 거의 모든 환자에서 표적부위에 100$\%$의 선량 조사가 가능하였으며 심장에 대한 DVH 분석결과 좌폐하엽 부위 종양 치료시에는 특히 3차원 입체조형 치료가 심장 선량을 줄여줌을 알수 있었다. 3차원 입체조형 치료에 의한 동측폐의 NTCP 평균값은 0.26 (0.17-0.43)으로 2차원 통상 치료의 NTCP 평균값 0.38 (0.27-0.66)에 비하여 부작용이 생길 확률이 32$\%$ 줄어들었다. 치료 결과는 26$\%$(25/95)의 환자에서 완전관해를 보였으며 53$\%$ (50/95)에서는 부분관해를 보여 전체 79$\%$의 환자에서 부분관해 이상의 반응을 보였다. 1기와 2기 환자 5명을 제외한 3기 환자 90명의 1년과 2년 생존율은 62.6$\%$와 35.2$\%$로 같은 기간에 2차원 통상치료로 치료받은 환자의 1년과 2년 생존율 51.9$\%$와 26.8$\%$에 비하여 다소 증가 되었으나 통계적으로 유의한 차이를 보이지는 않았다. 치료후 19명 (Grade 1:8, Grade 2:11)의 환자에서 방사선 폐렴이 발생하였으나 steroid 치료후 모두 호전되었으며 치료 후 발생하는 방사선 폐렴을 예측할 수 있는 가장 좋은 지표는 동측폐에 대한 NTCP 값이었다 (35$\%$ vs 22$\%$). 결론 : 이상의 결과 폐암에 대한 3차원 입체조형 방사선 치료는 기존의 치료법에 비하여 부작용의 증가 없이 총 방사선량을 증가시킬 수 있는 좋은 방법으로 생각되며 방사선 폐렴의 예측인자로는 동측폐에 대한 NTCP 값이 매우 유용한 것으로 보여진다. 향후 NTCP 값에 따른 선량증가 연구와 이에 따른 생존율의 증가에 대한 연구가 더 진행되어야 할 것이다.

  • PDF

한국성우(韓國成牛)의 혈액학치(血液學値) 및 혈액화학치(血液化學値)에 관한 연구(硏究) 제1보(第一報) 한국성우(韓國成牛)의 혈액학치(血液學値)에 관한 연구(硏究) (Studies on the Hematology and Blood Chemistry of Korean Cattle Part I. Studies on the Hematology of Korean Cattle)

  • 정창국
    • 대한수의학회지
    • /
    • 제5권1호
    • /
    • pp.61-96
    • /
    • 1965
  • Observations were made on the blood picture of total 196 heads of healthy Korean cattles, including 98 males and 98 females in the purpose of determination of hematological values and its sex difference, and seasonal variations during one year period from December 1963 to November 1964. The blood sampling were scheduled by random in four different seasons and the sample size of both sex included in each season were designated to be same size. The ranges, averages or mean values of the erythrocytes, hemoglobin, hematocrit, mean corpuscular hemoglobin concentration, total white blood cell count and differential count were determined in this studies and their respective standard deviation, standard error of means, sex defferences and seasonal variations were as follows; 1. The erythrocyte count of male showed a range of $5.0{\times}10^6/c.mm$ to $8.75{\times}10^6/c.mm$ with a mean of $6.5{\pm}0.096{\times}10^6/c.mm$. Female showed a range of $5.0{\times}10^6/c.mm$ to $8.30{\times}10^6/c.mm$, with a mean of 6. $131{\pm}0.078{\times}10^6/c.mm$. There was a highly significant sex difference and seasomal variation was not found to be significant. 2. The hemoglobin value of male showed a range of 9.0g/100cc. to 14.5g/100cc. with a mean of $11.074{\pm}0.143g/100cc$. Female showed a range of 9.0g/100cc to 13.0g/100cc. with a mean of $10.745{\pm}0.034g/100cc$. There was a highly significant sex difference and seasonal variation was not found to be significant. 3. The hematocrit value of male showed a range of 28% to 45% and with a mean of $34.867{\pm}0.468%$. Female showed a range of 28% to 42% with a mean of $32.888{\pm}0.322%$. There was a highly significant sex difference and seasonal variation was not found to be significant. 4. The mean corpuscular hemoglobin of male showed a range of 14.4rr. to 19.6rr. with a mean of $17.1{\pm}0.112rr$. Female showed a range of 14.7rr. to 19.5rr. with a mean of $17.6{\pm}0.113rr$. 5. The mean corpusular volume of male showed a range of $42.5{\mu}^3$ to $62.2{\mu}^3$ with a mean of $53.9{\pm}0.419{\mu}^3$, Female showed a range of $44.2{\mu}^3$ to $60.0{\mu}^3$ with a mean of $53.8{\pm}0.375{\mu}^3$. 6. The mean corpuscular hemoglobin concentration of male showed a range of 28.1 % to 34.9% with a mean of $31.4{\pm}0.161%$. Female showed a range of 28.0% to 34.9% with a mean of $30.9{\pm}0.169%$. 7. The total leucocyte count of male showed a range of 4,000/c.mm to 13,100/c.mm. with a mean of $9,338{\pm}218.23/c.mm$. Female showed a range of 4,000/c.mm. to 14,000/c.mm. with a mean of $9,338{\pm}235.90/c.mm$. Six difference was not found to be significant and there was a highly significant seasonal variation. 8. The differential count of male, the means of neutrophil, stab, segmented cell, Iymphocyte, monocyte, eosinophil and basophil were $31.173{\pm}0.570%$, 0.3%. $30.867{\pm}0.564%$, $55.112{\pm}0.603%$, $3.745{\pm}0.082%$, $9.867{\pm}0.422%$ and 0.14% rspectively. Female showed means of $31.010{\pm}0.572%$, 0.2%, $30.806{\pm}0.569%$, $53.929{\pm}0.634%$, $4.082{\pm}0.109%$, $10.908{\pm}0.503%$ and 0.12% respectively. There were significant sex differences in monocyte and highly significant sex difference in eosinophil, and seasonal variation were found to be highly significant in neutrophil, monocyte and eosinophil. 9. Hematological comparison made between cattles infested with so called "small type piroplasma" and non-infested group. The result of investigation showed no significant difference upon the red blood cell, hemoglobin and hematocrit values between lighty infested group and non-infested group. 10. Age distribution of test group in this study ranged from 2 years to 6 years in both sex and their average age were $4.45{\pm}0.114$(male) and $4.50{\pm}0.116$(female). There found to be no significant sex difference and seasonal variations in the age of test group.

  • PDF

디스플레이 시스템을 위한 소면적 12-bit 300MSPS CMOS D/A 변환기의 설계 (Design of a Small Area 12-bit 300MSPS CMOS D/A Converter for Display Systems)

  • 신승철;문준호;송민규
    • 대한전자공학회논문지SD
    • /
    • 제46권4호
    • /
    • pp.1-9
    • /
    • 2009
  • 본 논문에서는 디스플레이 시스템을 위한 소면적 12-bit 300MSPS의 D/A 변화기(DAC)를 제안한다. 최근 SoC(System-On-Chip) 경향에 맞는 소면적 DAC를 구현하기 위한 전체적인 구조는 6-MSB(Most Significant Bit) + 6-LSB(Least Significant Bit)의 full matrix 구조로 설계 하였다. 고해상도 동작에 요구되는 output impedance을 만족하는 monitoring bias 구조, 고속 동작 및 소면적 디지털 회로 구성을 위하여 logic과 latch 및 deglitching 역할을 동시에 할 수 있는 self-clocked switching logic을 각각 제안하였다. 설계된 DAC는 Samsung $0.13{\mu}m$ thick gate 1-poly 6-metal N-well CMOS 공정으로 제작되었다. 제작된 DAC의 측정결과 INL (Integrated Non Linearity) / DNL (Differential Non Linearity)은 ${\pm}3LSB$ / ${\pm}1LSB$ 이하로 나타났으며, 300MHz 샘플링 속도와 15MHz의 출력신호에서 SFDR은 약 70dB로 측정되었다. DAC의 유효면적은 $0.26mm^2$ ($510{\mu}m{\times}510{\mu}m$)로 기존의 DAC에 비하여 최대 40% 감소된 초소면적으로 구현되었으며, 최대 전력 소모는 100mW로 측정되었다.