• Title/Summary/Keyword: segmental motion

Search Result 81, Processing Time 0.033 seconds

The Effect Analysis of Postural Stability on the Inter-Segmental Spine Motion according to Types of Trunk Models in Drop Landing (드롭착지 동작 시 체간모델에 따른 척추분절운동이 자세안정성 해석에 미치는 영향)

  • Yoo, Kyoung-Seok
    • Korean Journal of Applied Biomechanics
    • /
    • v.24 no.4
    • /
    • pp.375-383
    • /
    • 2014
  • The purpose of this study was to assess the inter-segmental trunk motion during which multi-segmental movements of the spinal column was designed to interpret the effect of segmentation on the total measured spine motion. Also it analyzed the relative motion at three types of the spine models in drop landing. A secondary goal was to determine the intrinsic algorithmic errors of spine motion and the usefulness of such an approach as a tool to assess spinal motions. College students in the soccer team were selected the ten males with no history of spine symptoms or injuries. Each subject was given a fifteen minute adaptation period of drop landing on the 30cm height box. Inter-segmental spine motion were collected Vicon Motion Capture System (250 Hz) and synchronized with GRF data (1000 Hz). The result shows that Model III has a more increased range of motion (ROM) than Model I and Model II. And the Lagrange energy has significant difference of at E3 and E4 (p<.05). This study can be concluded that there are differences in the three models of algorithm during the phase of load absorption. Especially, Model III shows proper spine motion for the inter-segmental joint motion with the interaction effects using the seven segments. Model III shows more proper observed values about dynamic equilibrium than Model I & Model II. The findings have shown that the dynamic stability strategy of Model III toward multi-directional spinal motion supports for better function of the inter-segmental motor-control than the Model I and Model II.

Impact of scanning strategy on the accuracy of complete-arch intraoral scans: a preliminary study on segmental scans and merge methods

  • Mai, Hai Yen;Mai, Hang-Nga;Lee, Cheong-Hee;Lee, Kyu-Bok;Kim, So-yeun;Lee, Jae-Mok;Lee, Keun-Woo;Lee, Du-Hyeong
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.2
    • /
    • pp.88-95
    • /
    • 2022
  • PURPOSE. This study investigated the accuracy of full-arch intraoral scans obtained by various scan strategies with the segmental scan and merge methods. MATERIALS AND METHODS. Seventy intraoral scans (seven scans per group) were performed using 10 scan strategies that differed in the segmental scan (1, 2, or 3 segments) and the scanning motion (straight, zigzag, or combined). The three-dimensional (3D) geometric accuracy of scan images was evaluated by comparison with a reference image in an image analysis software program, in terms of the arch shape discrepancies. Measurement parameters were the intermolar distance, interpremolar distance, anteroposterior distance, and global surface deviation. One-way analysis of variance and Tukey honestly significance difference post hoc tests were carried out to compare differences among the scan strategy groups (α = .05). RESULTS. The linear discrepancy values of intraoral scans were not different among scan strategies performed with the single scan and segmental scan methods. In general, differences in the scan motion did not show different accuracies, except for the intermolar distance measured under the scan conditions of a 3-segmental scan and zigzag motion. The global surface deviations were not different among all scan strategies. CONCLUSION. The segmental scan and merge methods using two scan parts appear to be reliable as an alternative to the single scan method for full-arch intraoral scans. When three segmental scans are involved, the accuracy of complete arch scan can be negatively affected.

Radiographic Parameters of Segmental Instability in Lumbar Spine Using Kinetic MRI

  • Jang, Se-Youn;Kong, Min-Ho;Hymanson, Henry J.;Jin, Tae-Kyung;Song, Kwan-Young;Wang, Jeffrey C.
    • Journal of Korean Neurosurgical Society
    • /
    • v.45 no.1
    • /
    • pp.24-31
    • /
    • 2009
  • Objective : To investigate the effectiveness of radiographic parameters on segmental instability in the lumbar spine using Kinetic magnetic resonance imaging (MRI). Methods : Segmental motion, defined as excessive (more than 3 mm) translational motion from flexion to extension, was investigated in 309 subjects (927 segments) using Kinetic MRI. Radiographic parameters which can help indicate segmental instability include disc degeneration (DD), facet joint osteoarthritis (FJO), and ligament flavum hypertrophy (LFH). These three radiographic parameters were simultaneously evaluated, and the combinations corresponding to significant segmental instability at each level were determined. Results : The overall incidence of segmental instability was 10.5% at L3-L4, 16.5% at L4-L5, and 7.3% at L5-S1. DD and LFH at L3-L4 and FJO and LFH at L4-L5 were individually associated with segmental instability (p<0.05). At L4-L5, the following combinations had a higher incidence of segmental instability (p<0.05) when compared to other segments : (1) Grade IV DD with grade 3 FJO, (2) Grade 2 or 3 FJO with the presence of LFH, and (3) Grade IV DD with the presence of LFH. At L5-S1, the group with Grade III disc and Grade 3 FJO had a higher incidence of segmental instability than the group with Grade I or II DD and Grade 1 FJO. Conclusion : This study showed that the presences of either Grade IV DD or grade 3 FJO with LFH at L4-L5 were good indicators for segmental instability. Therefore, using these parameters simultaneously in patients with segmental instability would be useful for determining candidacy for surgical treatment.

Dynamic response and waterproof property of tunnel segmental lining subjected to earthquake action

  • Yan, Qixiang;Bao, Rui;Chen, Hang;Li, Binjia;Chen, Wenyu;Dai, Yongwen;Zhou, Hongyuan
    • Earthquakes and Structures
    • /
    • v.17 no.4
    • /
    • pp.411-424
    • /
    • 2019
  • In this study, a numerical model of a shield tunnel with an assembled segmental lining was built. The seismic response of the segmental lining of the section of the shield tunnel in Line 1 of the Chengdu Metro is analyzed as it passes through the interface of sand-cobble and mudstone layers. To do so, the node-stress seismic-motion input method was used to input the seismic motion measured during the 2008 Wenchuan earthquake, and the joint openings and dislocations associated with the earthquake action were obtained. With reference to the Ethylene-Propylene-Diene Monomer (EPDM) sealing gaskets used in the shield tunnels in the Chengdu Metro, numerical simulation was applied to analyze the contact pressure along the seepage paths and the waterproof property under different joint openings and dislocations. A laboratory test on the elastic sealing gasket was also conducted to study its waterproof property. The test results accord well with the numerical results and the occurrence of water seepage in the section of the shield tunnel in Line 1 of the Chengdu Metro during the 2008 Wenchuan earthquake was verified. These research results demonstrate the deformation of segmental joint under earthquake, also demonstrate the relationship between segmental joint deformation and waterproof property.

Reproducibility of an Automatic Quantitation of Regional Myocardial Wall Motion and Systolic Thickening on Gated Tc-99m-MIBI Myocardial SPECT (게이트 Tc-99m-MIBI SPECT에서 국소 심근운동과 수축기 심근두꺼워짐 자동정량화법의 재현성)

  • Paeng, Jin-Chul;Lee, Dong-Soo;Cheon, Gi-Jeong;Kim, Yu-Kyeong;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.6
    • /
    • pp.487-496
    • /
    • 2000
  • Purpose: The aim of this study is to investigate the reproducibility of the quantitative assessment of segmental wall motion and systolic thickening provided by an automatic quantitation algorithm. Materials and Methods: Tc-99m-MIBI gated myocardial SPECT with dipyridamole stress was performed in 31 patients with known or suspected coronary artery disease (4 with single, 6 with two, 11 with triple vessel disease; ejection fraction $51{\pm}14%$) twice consecutively in the same position. Myocardium was divided into 20 segments. Segmental wall motion and systolic thickening were calculated and expressed in mm and % increase respectively, using $AutoQUANT^{TM}$ software. The reproducibility of this quantitative measurement of wall motion and thickening was tested. Results: Correlations between repeated measurements on consecutive gated SPECT were excellent for wall motion (r=0.95) and systolic thickening (r=0.88). On Bland-Altman analysis, two standard deviation was 2 mm for repeated measurement of segmental wall motion, and 20% for that of systolic thickening. The weighted kappa values of repeated measurements were 0.807 for wall motion and 0.708 for systolic thickening. Sex, perfusion, or segmental location had no influence on reproducibility. Conclusion: Segmental wall motion and systolic thickening quantified using $AutoeUANT^{TM}$ software on gated myocardial SPECT offers good reproducibility and is significantly different when the change is more than 2 mm for wall motion and more than 20% for systolic thickening.

  • PDF

The Evaluation of Usefulness of Wide Beam Reconstruction Method on Segmental Perfusion and Regional Wall Motion in Myocardial Perfusion SPECT (심근관류 SPECT의 분절별 관류 및 국소벽 운동에서 Wide Beam Reconstruction기법의 유용성 평가)

  • Seong, Yong-Joon;Kim, Tae-Yeob;Moon, Il-Sang;Cho, Seong-Wook;Woo, Jae-Ryong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.51-57
    • /
    • 2011
  • Purpose: The aim of this study is to identify clinical usefulness of Wide Beam Reconstruction (WBR) which is called Xpress.cardiac$^{TM}$ to confirm the agreement between segmental perfusion and regional wall motion in myocardium compared to conventional OSEM method. Materials and Methods: Subjects were separated two groups. First group was composed of 20 normal control group. Second group was composed of 10 patients (abnormal group) who had coronary artery disease. Subjects underwent myocardial perfusion SPECT ($^{201}Tl$ rest and $^{99m}Tc$-MIBI stress). Image acquisition and reconstruction were that rest stage was each step per 30, 15 seconds and stress stage was each step per 25, 13 seconds, OSEM and WBR methods were applied. Segmental perfusion and regional wall motion were applied 20-segment model of QPS, QGS algorithm in AutoQuant. Status of perfusion was composed of 5 point scoring system (0=normal, 1=mild, 2=moderate, 3=severe hypokinesia, 4=dyskinesia). Status of regional wall motion was also composed of 5 point scoring (0=normal, 1=mild, 2=moderate, 3=severe hypokinesia, 4=dyskinesia). We evaluated the agreement between conventional OSEM and WBR through automatic quantification value. Results: The agreement of rest segmental perfusion between conventional OSEM and WBR in normal patients was 99% (396/400, k=0.662, p<0.0001) and one of rest regional wall motion was 83.8% (335/400, k=0.283), the agreement of stress segmental perfusion was 95.8%(383/400, k=0.656), one of stress regional wall motion was 87.3% (349/400, k=0.390). The match rate of rest segmental perfusion in abnormal patients was 83% (166/200, k=0.605, p<0.0001) and one of rest regional wall motion was 55.5% (111/200, k=0.385), the agreement of stress segmental perfusion was 79.5% (159/200, k=0.682), one of stress regional wall motion was 63.5% (127/200, k=0.486). Conclusion: Compared to conventional OSEM, WBR method had a good agreement of segmental perfusion in myocardium in normal and abnormal groups. However regional wall motion showed meaningful low agreement. Although WBR offers high resolution and contrast ratio, it is not useful method for gated myocardial perfusion SPECT.

  • PDF

Comparative Analysis of Cervical Arthroplasty Using Mobi-$C^{(R)}$ and Anterior Cervical Discectomy and Husion Using the $Solis^{(R)}$-Cage

  • Park, Jin-Hoon;Roh, Kwang-Ho;Cho, Ji-Young;Ra, Young-Shin;Rhim, Seung-Chul;Noh, Sung-Woo
    • Journal of Korean Neurosurgical Society
    • /
    • v.44 no.4
    • /
    • pp.217-221
    • /
    • 2008
  • Objective : Although anterior cervical discectomy and fusion (ACDF) is the standard treatment for degenerative cervical disc disease, concerns regarding adjacent level degeneration and loss of motion have suggested that arthroplasty may be a better alternative. We have compared clinical and radiological results in patients with cervical disc herniations treated with arthroplasty and ACDF. Methods : We evaluated 53 patients treated for cervical disc herniations with radiculopathy, 21 of whom underwent arthroplasty and 32 of whom underwent ACDF. Clinical results included the Visual Analogue Scale (VAS) score for upper extremity radiculopathy, neck disability index (NDI), duration of hospital stay and convalescence time. All patients were assessed radiologically by measuring cervical lordosis, segmental lordosis and segmental range-of-movement (ROM) of operated and adjacent disc levels. Results : Mean hospital stay (5.62 vs. 6.26 days, p<0.05) and interval between surgery and return to work (1.10 vs 2.92 weeks, p<0.05) were significantly shorter in the arthroplasty than in the fusion group. Mean NDI and extremity VAS score improved after 12 months in both groups. Although it was not significant, segmental ROM of adjacent levels was higher in the fusion group than in the arthroplasty group. And, segmental motion of operated levels in arthroplasty group maintained more than preoperative value at last follow up. Conclusion : Although clinical results were similar in the two groups, postoperative recovery was significantly shorter in the arthroplasty group. Although it was not significant, ROM of adjacent segments was less in the arthroplasty group. Motion of operated levels in arthroplasty group was preserved at last follow up.

Clinical Comparison of Posterolateral Fusion with Posterior Lumbar Interbody Fusion

  • Kim, Chang-Hyun;Gill, Seung-Bae;Jung, Myeng-Hun;Jang, Yeun-Kyu;Kim, Seong-Su
    • Journal of Korean Neurosurgical Society
    • /
    • v.40 no.2
    • /
    • pp.84-89
    • /
    • 2006
  • Objective : The purpose of this study is to compare the outcomes of two methods for stabilization and fusion : Postero-Lateral Fusion [PLF, pedicle screw fixation with bone graft] and Posterior Lumbar Interbody Fusion [PLIF, cage insertion] for spinal stenosis and recurred disc herniation except degenerative spondylolisthesis. Methods : Seventy one patients who underwent PLF [n=36] or PLIF [n=35] between 1997 and 2001 were evaluated prospectively. These two groups were compared for the change of interbody space, the range of segmental angle, the angle of lumbar motion, and clinical outcomes by Prolo scale. Results : The mean follow-up period was 32.6 months. The PLIF group showed statistically significant increase of the interbody space after surgery. However, the difference in the change of interbody space between two groups was insignificant [P value=0.05]. The range of segmental angle was better in the PLIF group, but the difference in the change of segmental angle was not statistically significant [P value=0.0l7]. Angle of lumbar motion was similar in the two groups. Changes of Prolo economic scale were not statistically significant [P value=0.193]. The PLIF group showed statistically significant improvement in Prolo functional scale [P value=0.003]. In Prolo economic and functional scale, there were statistically significant relationships between follow-up duration [P value<0.001]. change of interbody space [P value<0.001], and range of segmental angle [P value<0.001]. Conclusion : Results of this study indicate that PLIF is superior to PLF in interbody space augmentation and clinical outcomes by Prolo functional scale. Analysis of clinical outcomes showed significant relationships among various factors [fusion type, follow-up duration, change of interbody space, and range of segmental angle]. Therefore, the authors recommend instrumented PLIF to offer better clinical outcomes in patients who needed instrumented lumbar fusion for spinal stenosis and recurred disc herniation.

An Application of Triple Segmental System in Golf Swing through an Inverse Dynamics Function (Inverse Dynamics 함수를 이용한 골프스윙 3분절 시스템의 적용)

  • Lim, Jung;Moon, Gun-Pil
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.2
    • /
    • pp.57-67
    • /
    • 2005
  • The purpose of this study was to analyze the kinetic factors of the golf driver swing using the Inverse Dynamics function. For this purpose, joint force were calculated. In order to test the possibility of Inverse Dynamics function(motion-dependent interaction), a triple segmental system was set for wrist, left shoulder and lumbar and joint force working on the anatomical joint region was estimated. For this study, 7 professional golfers were sampled, and then, their driver swings were recorded with two high-speed digital video cameras (180 frames/sec.) to be synthesized into 3-dimensional images and coordinated. Then, Eular's equation was used to produce some kinematic data, which were used to calculate joint force and torque with Newton's function. All data were calculated using LabVIEW 6.1 graphic program. The results of this study can be summarized as follows; It was found that the joint force was generated on wrist, shoulder and lumbar joints in the direction of the target, and that the joint force was stronger in the direction of target immediately before impact. The joint force was generated towards the target to activate the nodes, and then, it was generated in the reverse direction to increase the speed during impact.

Molecular Dynamics Simulation Study on Segmental Motion in Liquid Normal Butane

  • 이송희;김한수
    • Bulletin of the Korean Chemical Society
    • /
    • v.19 no.10
    • /
    • pp.1068-1072
    • /
    • 1998
  • We present results of molecular dynamic (MD) simulations for the segmental motion of liquid n-butane as the base case for a consistent study for conformational transition from one rotational isomeric state to another in long chains of liquid n-alkanes. The behavior of the hazard plots for n-butane obtained from our MD simulations are compared with that for n-butane of Brownian dynamics study. The MD results for the conformational transition of n-butane by a Poisson process form the total first passage times are different from those from the separate t-g and g-t first passage times. This poor agreement is probably due to the failure of the detailed balance between the fractions of trans and gauche. The enhancement of the transitions t-g and g-t at short time regions are also discussed.