• Title/Summary/Keyword: sefA

Search Result 51, Processing Time 0.03 seconds

Analysis on the Depth of Anesthesia by Using EEG and ECG Signals

  • Ye, Soo-Young;Choi, Seok-Yoon;Kim, Dong-Hyun;Song, Seong-Hwan
    • Transactions on Electrical and Electronic Materials
    • /
    • v.14 no.6
    • /
    • pp.299-303
    • /
    • 2013
  • Anesthesia, which started being used to remove pain during surgery, has become itself one of the major concerns to be considered during surgery. While actual anesthesia is being performed, patients tend to have unpleasant experiences, due to wakening that accompanies pain, or wakening that does not accompany pain. Since this awakening during anesthesia is a most unpleasant experience in a patient's life, evaluating the depth of anesthesia during surgery is essential for patients to avoid this experience. Although there has been much effort on the understanding and measurement of the depth of anesthesia, while various researches were performed on the need of anesthesia, the development of an indicator that could objectively evaluate the depth of anesthesia, other than by using the patient's vital signs, is still inadequate. Therefore, this study was to develop an objective indicator by using EEG and ECG, which are essentially measured during the surgery, to evaluate the depth of anesthesia. The experiment was performed by taking patients who require a relatively short operation time, and general inhalation anesthetics among surgical patients in obstetrics and gynecology as the subjects of experiment, to measure the EEG and ECG signals of patients under anesthetics. The result showed that SEF using EEG and LF, HF using ECG signal and correlation dimension analysis parameter were valuable parameters that could measure the depth of anesthesia, by the stage of anesthesia.

Comparative Analysis of Salmonella enterica subsp. enterica Serovar Thompson Isolates associated with Outbreaks Using PFGE and wgMLST

  • Youngho Koh;Yunyoung Bae;Min-Jung Lee;Yu-Si Lee;Dong-Hyun Kang;Soon Han Kim
    • Journal of Microbiology and Biotechnology
    • /
    • v.32 no.12
    • /
    • pp.1605-1614
    • /
    • 2022
  • The strains associated with foodborne Salmonella enterica Thompson outbreaks in Korea have not been identified. Therefore, we characterized S. Thompson strains isolated from chocolate cakes linked to foodborne outbreaks in Korea. A total of 56 strains were isolated from preserved cake products, products in the supply chain distribution, the manufacturer's apparatus, and egg white liquid products used for cream preparation. Subsequently, serological typing, pathogenic gene-targeted polymerase chain reaction (PCR), pulsed-field gel electrophoresis (PFGE), and whole-genome multi-locus sequence typing (wgMLST) were performed to characterize these isolates. The antigen formula of all isolates was 7:k:1,5, namely Salmonella enterica subsp. enterica Serovar Thompson. All 56 isolates harbored invA, his, hin, and stn, and were negative for sefA and spvC based on gene-targeted PCR analyses. Based on PFGE results, these isolates were classified into one group based on the same SP6X01.011 pattern with 100% similarity. We selected 19 strains based on the region and sample type, which were subjected to wgMLST. Although the examined strains showed 100% similarity, they were classified into seven clusters based on allelic differences. According to our findings, the cause of these outbreaks was chocolate cake manufactured with egg white liquid contaminated with the same Salmonella Thompson. Additionally, comparative analysis of wgMLST on domestic isolates of S. Thompson from the three outbreaks showed genetic similarities of over 99.6%. Based on the results, the PFGE and wgMLST combination can provide highly resolved phylogeny and reliable evidence during Salmonella outbreak investigations.

A Study on the Correlation Analysis of EEG and Vibraimage due to Auditory and Olfactory Stimulation (청각 및 후각자극에 의한 뇌파(EEG)와 진동이미지기술의 상관성 분석에 관한 연구)

  • Kim, Jung-Min;Kim, Myung-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.4291-4297
    • /
    • 2015
  • EEG has been used to measure the emotion of amenity and discomfort in the interior space. EEG is limited to the experiment, because it is a equipment of contact type. However, Vibraimage can measure the emotion with a web camera. Because Vibraimage is a equipment of non-contact type, it is more suitable for the interior space than EEG. Therefor, it tries to find a correlation variable between EEG and Vibraimage to measure the human emotions. In this study, it were analyzed correlation of EEG and vibraimage due to variation of loudness 60[dB], 90[dB] and rosemary, jasmine scents. Check the health status of subjects who were selected 3 male students, and the period of this experiment was about months. The condition of the environmental test room was in temperature 25[$^{\circ}C$], relative humidity 50[RH%], air current speed 0.02[m/s] and illuminance 1000[lux]. It were analyzed correlation of twenty-three index of EEG(absolute ${\theta}$, relative ${\theta}$, absolute $S{\alpha}$, relative $S{\alpha}$, absolute ${\alpha}$, relative ${\alpha}$, absolute ${\beta}$, relative ${\beta}$, absolute $\gamma$, relative $\gamma$, absolute $F{\alpha}$, relative $F{\alpha}$, absolute SMR, relative SMR, $SMR/{\theta}$, $SMR+M{\beta}/{\theta}$, absolute $H{\beta}$, relative $H{\beta}$, $H{\beta}/{\alpha}$, absolute $M{\beta}$, relative $M{\beta}$, SEF50, ASEF50) and ten index of Vibraimage(Aggression, Stress, Tension/Anxiety, Suspect, Balance, Charm, Energy, Self regulation, Inhibition, Neuroticism). As a result, I was found that relative ${\gamma}$ index of EEG and neuroticism index of Vibraimage have a high correlation as (${\pm}$).414 and (${\pm}$).424.

Analysis of electroencephalogram-derived indexes for anesthetic depth monitoring in pediatric patients with intellectual disability undergoing dental surgery

  • Silva, Aura;Amorim, Pedro;Felix, Luiza;Abelha, Fernando;Mourao, Joana
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.18 no.4
    • /
    • pp.235-244
    • /
    • 2018
  • Background: Patients with intellectual disability (ID) often require general anesthesia during oral procedures. Anesthetic depth monitoring in these patients can be difficult due to their already altered mental state prior to anesthesia. In this study, the utility of electroencephalographic indexes to reflect anesthetic depth was evaluated in pediatric patients with ID. Methods: Seventeen patients (mean age, $9.6{\pm}2.9years$) scheduled for dental procedures were enrolled in this study. After anesthesia induction with propofol or sevoflurane, a bilateral sensor was placed on the patient's forehead and the bispectral index (BIS) was recorded. Anesthesia was maintained with sevoflurane, which was adjusted according to the clinical signs by an anesthesiologist blinded to the BIS value. The index performance was accessed by correlation (with the end-tidal sevoflurane [EtSevo] concentration) and prediction probability (with a clinical scale of anesthesia). The asymmetry of the electroencephalogram between the left and right sides was also analyzed. Results: The BIS had good correlation and prediction probabilities (above 0.5) in the majority of patients; however, BIS was not correlated with EtSevo or the clinical scale of anesthesia in patients with Lennox-Gastaut, West syndrome, cerebral palsy, and epilepsy. BIS showed better correlations than SEF95 and TP. No significant differences were observed between the left- and right-side indexes. Conclusion: BIS may be able to reflect sevoflurane anesthetic depth in patients with some types of ID; however, more research is required to better define the neurological conditions and/or degrees of disability that may allow anesthesiologists to use the BIS.

Spatial correlation of aerodynamic forces on 5:1 rectangular cylinder in different VIV stages

  • Lei, Yongfu;Sun, Yanguo;Zhang, Tianyi;Yang, Xiongwei;Li, Mingshui
    • Wind and Structures
    • /
    • v.34 no.1
    • /
    • pp.81-90
    • /
    • 2022
  • To better understand the vortex-induced vibration (VIV) characteristics of a 5:1 rectangular cylinder, the distribution of aerodynamic force and the non-dimensional power spectral density (PSD) of fluctuating pressure on the side surface were studied in different VIV development stages, and their differences in the stationary state and vibration stages were analyzed. The spanwise and streamwise correlations of surface pressures were studied, and the flow field structure partitions on the side surface were defined based on the streamwise correlation analysis. The results show that the variation tendencies of mean and root mean square (RMS) pressure coefficients are similar in different VIV development stages. The RMS values during amplitude growth are larger than those at peak amplitude, and the smallest RMS values are observed in the stationary state. The spanwise correlation coefficients of aerodynamic lifts increase with increase of the peak amplitude. However, for the lock-in region, the maximum spanwise correlation coefficient for aerodynamic lifts occurs in the VIV rising stage rather than in the peak amplitude stage, probably due to the interaction of vortex shedding force (VSF) and self-excited force (SEF). The streamwise correlation results show that the demarcation point positions between the recirculation region and the main vortex region remain almost constant in different VIV development stages, and the reattachment points gradually move to the tailing edge with increasing amplitude. This study provides a reference to estimate the demarcation point and reattachment point positions through streamwise correlation and phase angle analysis from wind tunnel tests.

EEG based Cognitive Load Measurement for e-learning Application (이러닝 적용을 위한 뇌파기반 인지부하 측정)

  • Kim, Jun;Song, Ki-Sang
    • Korean Journal of Cognitive Science
    • /
    • v.20 no.2
    • /
    • pp.125-154
    • /
    • 2009
  • This paper describes the possibility of human physiological data, especially brain-wave activity, to detect cognitive overload, a phenomenon that may occur while learner uses an e-learning system. If it is found that cognitive overload to be detectable, providing appropriate feedback to learners may be possible. To illustrate the possibility, while engaging in cognitive activities, cognitive load levels were measured by EEG (electroencephalogram) to seek detection of cognitive overload. The task given to learner was a computerized listening and recall test designed to measure working memory capacity, and the test had four progressively increasing degrees of difficulty. Eight male, right-handed, university students were asked to answer 4 sets of tests and each test took from 61 seconds to 198 seconds. A correction ratio was then calculated and EEG results analyzed. The correction ratio of listening and recall tests were 84.5%, 90.6%, 62.5% and 56.3% respectively, and the degree of difficulty had statistical significance. The data highlighted learner cognitive overload on test level of 3 and 4, the higher level tests. Second, the SEF-95% value was greater on test3 and 4 than on tests 1 and 2 indicating that tests 3 and 4 imposed greater cognitive load on participants. Third, the relative power of EEG gamma wave rapidly increased on the 3rd and $4^{th}$ test, and signals from channel F3, F4, C4, F7, and F8 showed statistically significance. These five channels are surrounding the brain's Broca area, and from a brain mapping analysis it was found that F8, right-half of the brain area, was activated relative to the degree of difficulty. Lastly, cross relation analysis showed greater increasing in synchronization at test3 and $4^{th}$ at test1 and 2. From these findings, it is possible to measure brain cognitive load level and cognitive over load via brain activity, which may provide atimely feedback scheme for e-learning systems.

  • PDF

The Analysis of Quantitative EEG to the Left Cranial Cervical Ganglion Block in Beagle Dogs (비글견에서 좌측앞쪽목신경절 차단에 대한 정량적 뇌파 분석)

  • Park, Woo-Dae;Bae, Chun-Sik;Kim, Se-Eun;Lee, Soo-Han;Lee, Jung-Sun;Chang, Wha-Seok;Chung, Dai-Jung;Lee, Jae-Hoon;Kim, Hwi-Yool
    • Journal of Veterinary Clinics
    • /
    • v.24 no.4
    • /
    • pp.514-521
    • /
    • 2007
  • The sympathetic nerve block improves the blood flow in the innervated regions. For this region, the sympathetic nerve block has been performed in the neural and cerebral disorders. However, the cerebral blood flow regulation of the cranial cervical ganglion block in dogs have not been well defined and the correlation to the changes in the cerebral circulation and the changes in the electroencephalogram is not well defined in dogs yet. Therefore, we investigated the hypothesis that changes in the EEG could be affected by the changes in cerebral blood flow following the cranial cervical ganglion block in dogs. Twenty five beagle dogs were divided into 3 groups; group I(LCCGB, n=10) underwent left sided cranial cervical ganglion block using the 1% lidocaine, group II(L, n=10) injected the 1% lidocaine into the right or left sided digastricus muscle, group III(N/SCCGB, n=5, served as control) underwent the left sided cranial cervical ganglion block using saline. A statistical difference was not found between the control group and the LCCGB group in the 95% spectral edge frequency(SEF) and the median frequency(MF). In the relative band power, the $\delta$ frequency was decreased during 5-25 min, while the $\alpha$ frequency was increased during the same time(p<0.05). But the $\theta$ frequency and the $\beta$ frequency were not shown the significant changes compared with the control group during the same time(p<0.05). These results suggest that the left cranial cervical ganglion block does not induce the change of the cerebral blood flow and its effect is insignificant.

Analysis on the Trends of Science Education Studies Related to 'Science Inquiry' by Professional Factors of Teaching Practice for Science Inquiry (과학탐구 수업실행 전문성 요소에 의한 '과학탐구' 관련 연구동향 분석)

  • Lee, Dongseung;Park, Jeongseok
    • Journal of the Korean Chemical Society
    • /
    • v.61 no.4
    • /
    • pp.197-203
    • /
    • 2017
  • The purpose of this study is to analyse the characteristics of domestic scientific inquiry related research topics and consequently provide fundamental data and suggestions from a teaching method point of view. The study subjects was collected from the initial issue to the february 2016 issue of academic journals and using the keyword that 'inquiry', 'scientific inquiry'. The framework of Professional factors of teaching practice was developed and used for selecting subjects of study. The selected study subjects were analyzed according to the framework. And Topics of study were categorized and analyzed. The topic was thoroughly debated between 2 science education experts and 4 doctorate candidates within a specialist workshop. Results show that scientific education environments, scientific inquiry evaluation and teaching ability was studied less than education process and textbook analysis, scientific inquiry designing and application. And The research on the topics indicated that most research is concentrated in specific areas. It is postulated that additional research into scientific education environments, scientific inquiry evaluation and teaching ability would further develop the teachers' teaching abilities and enable a more successful science lesson in the classroom.

A Study on the Synergistic Effects of Hybrid System Simultaneously Irradiating the UV and US (자외선과 초음파를 동시에 조사하는 연계 공정의 시너지 효과에 관한 연구)

  • Lee, Hanuk;Han, Jonghun;Yoon, Yeomin;Lee, Jongyeol;Park, Jaewoo;Her, Namguk
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.7
    • /
    • pp.5-11
    • /
    • 2014
  • Both ultraviolet (UV) and ultrasound (US) systems are used in degrading of organic contaminants and they can thus be applicable simultaneously as an UV/US hybrid system in attempts further to increase the degradation efficiency. The pseudo-first order degradation rate constants with the UV, US and UV/US hybrid irradiation were 2.60, 10.34, and $14.81{\times}10^{-3}min^{-1}$, respectively. It was observed that the synergistic effect of UV/US hybrid system for degrading the bis (2-ethylhexyl) phthalate (DEHP). The highest rate of DEHP degradation was found during UV/US hybrid irradiation and the synergistic effect factor (SEF) was calculated to be 1.15 based on the pseudo-first order degradation rate constants. Results indicate that synergistic effect of UV/US hybrid system is closely correlated to the enhancement of sonochemical reactivity with the UV-US interaction of increasing the formation rate of OHby providing additional $H_2O_2$ production through the pyrolysis of water molecules during UV/US hybrid irradiation.

A Comparative study of roughness of enamel surface to various interdental enamel stripping methods in vitro (치간 법랑질 삭제방법에 따른 치아표면 거칠기에 관한 비교연구)

  • Row, Joon;Chun, Youn-Sic
    • The korean journal of orthodontics
    • /
    • v.29 no.4 s.75
    • /
    • pp.483-490
    • /
    • 1999
  • Interdental enamel stripping is an usual method for correction of abnormal tooth shape and tooth size discrepancy which is one of the etiologic factors of malocclusion. Clinically it Is useful to correct the minor crowding in anterior teeth and posterior occlusion during finishing stage of orthodontic treatment. But this procedure has risks such as irreversible tooth reduction and remaining roughness of enamel surface can accumulate plaque which can evoke periodontal problem. Even if various methods were introduced to minimize the enamel surface roughness, their evaluation was limited in morphologic differences by scanning electronic microscope(SEM). The purpose of this study was to compare the various interdental enamel stripping method by SEM and to quantify the difference of surface roughness by use of Surfcorder SEF-30D(Kosaka Lab. Ltd.) which can measure the roughness of surface. The stripping methods were divided into mechanical and mechanical-chemical method. Air-rotor stripping and separating strip were used for mechanical stripping and $37\%$ phosphoric acid was used for chemical stripping. The enamel surface roughness after mechanical or mechanical-chemical stripping of interproximal surfaces of premolars which were extracted for orthodontic purpose were measured and compared by means of SEM and $Surfcorder^{\circledR}$, the results were as follows. 1. Enamel surface of primary treated by coarse diamond bur and separating strip groups showed highest value of roughness. 2. To compare the primary treated groups between mechanical and mechanical-chemical method, the latter group showed lower value of roughness remarkably. 3. Mechanical stripping groups which were treated both coarse and fine instrument showed lower value of roughness as much as non treated group. 4. The use of Pumice for final polishing did not show significantly smoothening the stripped enamel surface any more.

  • PDF