• Title/Summary/Keyword: sediment characteristics

Search Result 1,037, Processing Time 0.024 seconds

Development of SWAT SD-HRU Pre-processor Module for Accurate Estimation of Slope and Slope Length of Each HRU Considering Spatial Topographic Characteristics in SWAT (SWAT HRU 단위의 경사도/경사장 산정을 위한 SWAT SD-HRU 전처리 프로세서 모듈 개발)

  • Jang, Wonseok;Yoo, Dongsun;Chung, Il-moon;Kim, Namwon;Jun, Mansig;Park, Younshik;Kim, Jonggun;Lim, Kyoung-Jae
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.3
    • /
    • pp.351-362
    • /
    • 2009
  • The Soil and Water Assessment Tool (SWAT) model, semi-distributed model, first divides the watershed into multiple subwatersheds, and then extracts the basic computation element, called the Hydrologic Response Unit (HRU). In the process of HRU generation, the spatial information of land use and soil maps within each subwatershed is lost. The SWAT model estimates the HRU topographic data based on the average slope of each subwatershed, and then use this topographic datum for all HRUs within the subwatershed. To improve the SWAT capabilities for various watershed scenarios, the Spatially Distributed-HRU (SD-HRU) pre-processor module was developed in this study to simulate site-specific topographic data. The SD-HRU was applied to the Hae-an watershed, where field slope lengths and slopes are measured for all agricultural fields. The analysis revealed that the SD-HRU pre-processor module needs to be applied in SWAT sediment simulation for accurate analysis of soil erosion and sediment behaviors. If the SD-HRU pre-processor module is not applied in SWAT runs, the other SWAT factors may be over or under estimated, resulting in errors in physical and empirical computation modules although the SWAT estimated flow and sediment values match the measured data reasonably well.

The Variation of Water Quality due to Sulice Gate Operation in Shiwha Lake (시화호의 배수갑문 운용에 따른 수질변화)

  • 김종구;김준우;조은일
    • Journal of Environmental Science International
    • /
    • v.11 no.12
    • /
    • pp.1205-1215
    • /
    • 2002
  • To evaluate the change for water quality after the water gate operation in Shiwha lake, in situ survey were conducted on september in 2000 and January, march, jane in 2001. Chemical characteristics and eutrophication level was estimated from the survey data. The water quality of the Shihwa lake was greatly affected by pollutant load from rainfall, and formation of stratification in summer and winter was increased to effect on nutrient release from sediment. Especially, high concentration of chlorophyll-a was occurred in autumn, due to increased nutrient, high water temperature and low salinity after rainfall runoff. The mean concentration of DIN, DIP were 0.346mg/L, 0.0217mg/L in surface water and 0.826mg/L, 0.0415mg/L in bottom water, respectively, which were over III grade of seawater standard. Also high percentage of ammonia nitrogen to DIN in bottom water for autumn and winter was affected by released nutrient from sediment. Correlation analysis of chlorophyll-a versus TSS was shown that organic matter was affected by autochthonous organic matter stem from the algae, these factor showed reverse correlation about salinity. Closely correlations among to the water quality constituent in continuity survey was appeared. The results of eutrophication index estimation showed the high potentiality of red tide occurrence in Shiwha lake, particularity in summer or fall. Overall water quality was greatly improve to compared with measuring data during 1997~1998 at the beginning water gate operation, which reported by KORDI. Therefore, to improve of water quality in Shiwha lake, we need to establish of management plan about nutrient release from sediment, rainfall runoff, maximum of seawater exchange.

The Effect of Different Particle Size from PAHs Contaminated Sediment by Ultrasonic Irradiation (PAHs로 오염된 침전물의 초음파 처리시 입자크기가 미치는 영향)

  • Na, Seung-Min;Khim, Jee-Hyeong;Cui, Ming-Can;Ahn, Yun-Gyong;Weavers, Linda K.
    • Journal of Environmental Science International
    • /
    • v.19 no.3
    • /
    • pp.379-387
    • /
    • 2010
  • Sediments of Little Scioto (LS) River in Ohio was contaminated by poor disposal of creosote from Baker Wood Creosoting Facility. Among the primary compounds of creosote, Polycyclic Aromatic Hydrocarbons (PAHs) are the most common ingredient PAHs are known for toxic, carcinogenic and mutagenic compounds. There are many difficulties to remove the PAHs in nature environment because their characteristics are having a less water-solubility, volatile and low mobility properties as increasing the molecular weight. The generation of hydroxyl radicals (${\cdot}OH$) and hydrogen peroxide ($H_2O_2$) forms as well as high temperature (5000 K) and pressure (1000 atm) by a physico-chemical effects of ultrasound during a cavitation collapse can promote the degradation and desorption of PAHs in sediment And it can also produces shock wave and microjets which are able to change the size and surface of particle in solid-liquid system as one of physical effects. Therefore, we explored to understand the role of particle size, the effect of elimination for PAHs concentration by ultrasound and optimize the conditions for ultrasonic treatment. The condition of various size of particles (> $150{\mu}m$, < $150{\mu}m$) and solid-liquid ratio (12.5g/L, 25g/L) for the treatment was considered and ultrasonic power (430 W/L) with liquid - hexane extraction and microwave extraction method were applied after ultrasound treatment.

Effects of Subwatershed Delineation on SWAT Estimation (소유역구분이 SWAT 예측치에 미치는 영향 평가)

  • Heo, Seong-Gu;Kim, Gi-Seong;An, Jae-Hun;Im, Gyeong-Jae;Choe, Jung-Dae
    • KCID journal
    • /
    • v.13 no.2
    • /
    • pp.262-273
    • /
    • 2006
  • The Soil and Water Assessment Tool (SWAT) model has been widely used in hydrology and sediment simulation worldwide. In most cases, the SWAT model is first calibrated with adjustments in model parameters, and then the validation is performed. However, very little study regarding the effects on SWAT estimation of subwatershed delineation was performed. Thus, the SWAT model was applied to the Doam-dam watershed with various threshold values in subwatershed delineation in this study to examine the effects on the number of subwatershed delineated on SWAT estimation. It was found the flow effect of subwatershed delineation is negligible. However there were huge variations in SWAT estimated sediment, T-N, and T-P values with the use of various threshold value in watershed delineation. Sometimes these variations due to watershed delineation are beyond the effects of parameter adjustment in model calibration and validation. The SWAT is a semi-distributed modeling system, thus, the subwatershed characteristics are assumed to be the same for all Hydrologic Response Unit (HRU) within that subwatershed. This assumption leads to variations in the SWAT estimated sediment and nutrient output values. Therefore, it is strongly recommended the SWAT users need to use the HUR specific slope length and slope value in model runs, instead of using the slope and the corresponding slope length of the subawatershed to exclude the effects of the number of subwatershed delineated on the SWAT estimation.

  • PDF

Contamination Status and Characteristics of Persistent Organochlorine Pesticides in the Saemangeum Environment (새만금 해양환경에서의 잔류성 유기염소계 농약의 분포 및 특성)

  • Hong, Sang-Hee;Shim, Won-Joon;Li, Dong-Hao;Yim, Un-Hyuk;Oh, Jae-Ryoung;Kim, Eun-Soo
    • Ocean and Polar Research
    • /
    • v.28 no.3
    • /
    • pp.317-329
    • /
    • 2006
  • To assess the contamination status of organochlorine pesticides in the marine environment of Saemangeum, surface seawater and sediments were collected and analyzed. Organochlorine pesticides were widely distributed in the Saemangeum environment, with DDT, HCH and endosulfan II contamination being particularly prevalent. The overall concentrations of DDTs, HCHs, and endosulfan II in surface seawater were in the rage of 0.03-0.65ng/l (mean value: 0.36ng/l), 1.31-4.54ng/l (2.63 ng/l), and not detected (ND)-0.96ng/l (0.49ng/l), respectively. Among the target organochlorine pesticides, endosulfan II showed the hi띤est level at the river mouth flowing into the Saemangeum. Additionally, its negative gradient from the rivers to the outside and a good correlation with $NO_3^-$ indicate that endosulfan ll inflows to the Saemangeum through the river; this conclusion is also supported by the elevated levels of endosulfan II in sediments at the river mouth. In sediment, the concentration of DDTs, HCHs, CHLs, and endosulfan II were in the range of 0.05-1.96 ng/g, 0.03-0.31ng/g, 0.01-0.13ng/g, and ND-0.62ng/g, respectively. Levels of contamination in Saemangeum are relatively lower than the median concentrations previously observed at the Korean coastal regions and sediment quality guidelines suggested by NOAA (Long et at. 1995).

Odor Emission from Sediments in Sewer Systems and Odor Removal using an Electrolytic Oxidation Process (하수관거에 퇴적된 유기물에 의한 악취 발생과 산화전리시스템을 이용한 악취 저감)

  • Ahn, Hae-Young;Shin, Seung-Kyu;Song, Ji-Hyeon
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.6
    • /
    • pp.703-710
    • /
    • 2011
  • Odor emission from domestic sewer systems has become a serious environmental problem. An investigation on a sewer manhole revealed that anaerobic decay of sediment organic matters (SOMs) and related declines of oxidation reduction potential (ORP) in the sediment layer were the main reason of the production of volatile sulfur compounds. In addition, as the anaerobic decaying period continued, the odor intensity rapidly increased with increasing concentrations of $H_2S$ and dimethyl sulfide. As a feasible method to control SOMs and to minimize odor emission potentials, an electrolytic oxidation process has been employed to the sediment sludge phase. In this study, voltages applied to the electrolytic oxidation process were varied as a main system parameter, and its effects on odor removal efficiencies and reaction characteristics were investigated. At the applied voltages greater than 20 V, the system efficiently oxidized the organic matter, and the ORP in the sludge phase increased rapidly. As a consequence, the removal efficiency of hydrogen sulfide was found to be >99% within 60 minutes of the electrolytic oxidation. Overall, the electrolytic oxidation process can be an alternative to control odor emission from sewer systems, and a threshold input energy needs to be determined to achieve effective operation of the process.

Influence of Organic Pigment Blending on Surface and Optical Properties of Coated Paper (유기안료 배합이 도공층의 표면 및 광학적 특성에 미치는 영향)

  • Jeong, Kyoung-Mo;Won, Jong-Myoung;Lee, Yong-Kyu
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.44 no.3
    • /
    • pp.1-8
    • /
    • 2012
  • The effects of several factors including organic pigment blending and calending conditions on the surface and optical properties of coated paper were investigated. When clay and calcium carbonate are blended in the ratio of 7 to 3, highest smoothness and relative sediment volume were obtained. When organic pigments were added to the mixture of clay and calcium carbonate, the relative sediment volume did not changed significantly. However, when organic pigments were added to calcium carbonate, sheet gloss and smoothness were improved, and showed the better results than that obtained from the mixture of organic pigment and clay. When organic pigment is blended with clay, the particles of organic pigment are buried in the packing structure of coating layer. However, the particle shape of calcium carbonate is quite different from that of clay, and the aspect ratio of calcium carbonate is similar to that of organic pigment. Thus organic pigment particles are not buried and improved effectively the physical characteristics of coating layer. When the hollow sphere pigment was blended, opacity and sheet gloss were improved significantly. Even though the coating color applied was reduced, the similar level of opacity was maintained. Also, if particle size and void volume are increased, gloss is improved, because coating layer is easily transformed in calendering. Therefore, even though lower pressure was applied during calendering, the smoothness of surface of coating layer was improved, and the decrease of void volume in coating layer was reduced, and the quality of coated sheet can be improved.

Maxima Analysis from Visualized Image based on Multi-Resolution Analysis (다중해상도 웨이브렛 해석을 기본으로 한 가시화 영상의 극대값 해석)

  • Park, Young-Sik;Kim, Og-Gyu
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.11 no.2
    • /
    • pp.157-162
    • /
    • 2010
  • In this paper we propose a fractal analysis based on the discrete wavelet transform. It is well known that Fourier Transform is widely used for frequency analysis of random signal. However, the frequency domain is not used for expressing the sudden signal change and non-stationary signal at the time-axis by this method. Maximum value in the wavelet modules can be expressed by the Lipschitz exponent, which is useful to represent the characteristics of signal or the edge of an image. It is possible to reconstruct the original image only by using the few maximum points. The v possible image It iusing oil was acquired to interpret the maximum value. ufter that, it was applied to the v possible image of a ship model. In addition, the fractal dimens by by the conlapse process of the sediment particle was examined. In this paper, the fractal dimens by has been obtained by the maximum value and the experiment obtained from the visualized image also acquired the same result as existing methods.

Laboratory/In situ Sound Velocities of Shelf Sediments in the South Sea of Korea

  • Kim, Dae-Choul;Kim, Gil-Young;Jung, Ja-Hun;Seo, Young-Kyo;Wilkens, Roy H.;Yoo, Dong-Geun;Lee, Gwang-Hoon;Kim, Jeong-Chang;Yi, Hi-Il;Cifci, Gunay
    • Fisheries and Aquatic Sciences
    • /
    • v.11 no.2
    • /
    • pp.103-112
    • /
    • 2008
  • Compressional sound velocities of shelf sediments in the South Sea of Korea, were measured in situ and in the laboratory for six cores. In situ sound velocity was measured using the Acoustic Lance (frequency of 7.5-15 kHz), while laboratory velocity was measured by the pulse transmission technique (frequency of 1MHz). Physical properties were relatively uniform with sediment depth, suggesting little effect of sediment compaction and/or consolidation. Average in situ velocity at each core site ranged from 1,457 to 1,488 m/s, which was less than the laboratory velocity of 1,503 and 1,604m/s. In muddy sediments the laboratory velocity was 39-47 m/s higher than in situ velocity. In sandy sediments, the difference was greater by an average of 116 m/s. Although the velocity data were corrected by the velocity ratio method based on bottom water temperature, the laboratory velocity was still higher than the in situ velocity (11-21 m/s in muddy sediments and 91 m/s in sandy sediments). This discrepancy may be caused by sediment disturbance during core collection and/or by the pressure of Acoustic Lance insertion, but it was most likely due to the frequency difference between in situ and laboratory measurement systems. Thus, when correcting laboratory velocity to in situ velocity, it is important to consider both temperature and frequency.

Microbiological and Chemical Analyses of Paldang Lake Water (팔당호 수질의 미생물학 및 화학적 분석)

  • 김상진
    • Korean Journal of Microbiology
    • /
    • v.31 no.1
    • /
    • pp.85-92
    • /
    • 1993
  • To investigate the eutrophication process and pollution characteristics in Paldang Lake, Korea, water and sediment samples were analysed during July 1986~June 1987. The transparency, chlorophyll-a concentration, dissolved oxygen concentration and biochemical oxygen demand in Paldang Lake ranged 0.5~3 m, 3-17 ${\mu}gI^{-1}$, 7.2~12.3 ppm and 0.5~2.3 ppm, respectively. Heterotrophic bacterial number fluctuated seasonally between $3.0{\times}10^{3}/ml and 5.0{\times}10^{5}/ml$ in the water column and between $2{\times}10^{6} and 1{\times}10^{8}$ in the I g dry sediment. Water turbulence and water quality of up-stream seem to play important roles for determining the water quality in Paldang Lake particularly where the hydraulic retention time is so short as about 5 days. The present water quality in Paldang Lake according to the criteria of lake water quality was shown to be between mesotrophic and eutrophic state by secchi depth(O.5 ~ 3 m) and chlorophyll-a concentration (3~17 ${\mu}gI^{-1}$). The distribution of coliform bacteria showed that the pollution was mainly due to the human activities in this area and it is needed to establish countmeasurements for the problems.

  • PDF