Proceedings of the Korean Society of Computer Information Conference
/
2011.06a
/
pp.111-113
/
2011
우리나라에서도 2010년 1월 25일 지식경제부의 "Smart Grid 로드맵" 확정으로 Smart Grid 사업이 진행 중이다. 그러나 정보통신 환경에서 발생하고 있는 다양한 공격에 대한 보안위협이 Smart Meter에서도 발생하고 있다. 따라서 본 논문에서는 Smart Grid에 사용되는 Smart Meter 공격을 분석하고 Smart Meter 방어 방안을 제시한다.
Latest in Smart Grid projects are emerging as the biggest issue that smart meter should meet the security goal and the SW upgrade for compliance with future standard. However, unlike regular equipment, Smart meters should be designed in accordance with the regulation of legal metrology instrument in order to establish a fair trade-based business and unauthorized changes, it is not allowed and it is strictly limited by law. Therefore, this paper propose a new scheme of certification regarding type approval and verification for legal smart meter as analyzing the requirements of a smart meter regarding upgrade and security. This analysis shows that the proposed scheme comply with the regulation and the specification of smart meter by applying it to smart meter with smart card.
Journal of the Korea Institute of Information Security & Cryptology
/
v.25
no.5
/
pp.1001-1009
/
2015
In Smart Grid, smart meter sends our electric signal data to the main server of power supply in real-time. However, the more efficient the management of power loads become, the more likely the user's pattern of usage leaks. This paper points out the threat of privacy and the need of security measures in smart device environment by showing that it's possible to identify the appliances and the specific usage patterns of users from the smart meter's data. Learning algorithm PCA is used to reduce the dimension of the feature space and k-NN Classifier to infer appliances and states of them. Accuracy is validated with 10-fold Cross Validation.
Hafiz Abdullah, Muhammad Daniel;Hanapi, Zurina Mohd;Zukarnain, Zuriati Ahmad;Mohamed, Mohamad Afendee
KSII Transactions on Internet and Information Systems (TIIS)
/
v.9
no.4
/
pp.1493-1515
/
2015
A smart meter is one of the core components in Advanced Metering Infrastructure (AMI) that is responsible for providing effective control and monitor of electrical energy consumptions. The multifunction tasks that a smart meter carries out such as facilitating two-way communication between utility providers and consumers, managing metering data, delivering anomalies reports, analyzing fault and power quality, simply show that there are huge amount of data exchange in smart metering networks (SMNs). These data are prone to security threats due to high dependability of SMNs on Internet-based communication, which is highly insecure. Therefore, there is a need to identify all possible security threats over this network and propose suitable countermeasures for securing the communication between smart meters and utility provider office. This paper studies the architecture of the smart grid communication networks, focuses on smart metering networks and discusses how such networks can be vulnerable to security attacks. This paper also presents current mechanisms that have been used to secure the smart metering networks from specific type of attacks in SMNs. Moreover, we highlight several open issues related to the security and privacy of SMNs which we anticipate could serve as baseline for future research directions.
Journal of the Korea Institute of Information Security & Cryptology
/
v.26
no.3
/
pp.809-820
/
2016
The smart grid, a new open platform, is a core application for facilitating a creative economy in the era of the Internet of Things (IoT). Advanced Metering Infrastructure (AMI) is one of the components of the smart grid and a two-way communications infrastructure between the main utility operator and customer. The smart meter records consumption of electrical energy and communicates that information back to the utility for monitoring and billing. This paper investigates the impact of a cybersecurity attack on the smart meter. We analyze the cost to the smart grid in the case of a smart meter attack by authorized users based on a high risk scenario from NESCOR. Our findings could be used by policy makers and utility operators to create investment decision-making models for smart grid security.
Journal of the Korea Institute of Information Security & Cryptology
/
v.24
no.5
/
pp.1001-1011
/
2014
Smart Grid Devices could have security vulnerabilities that have legacy communication networks because of the fact that Smart Grid employs bi-directional communications and adopted a variety of communication interface. Consequently, it is required to build concrete response processes and to minimize the damage of the cyber attacks including security evaluation and certification methods. DCU is designed to collect meter data from numerous smart meter and send to utility's server so DCU installed between smart meter and utility's server. For this reason, If DCU compromised by attacker then attacker could use DCU to launching point for and attack on other devices. However, DCU's security evaluation and certification techniques do not suffice to be deployed in smart grid infrastructure. This work development DCU protection profile based on CC, it is expected that provide some assistance to DCU manufacturer for development of DCU security target and to DCU operator for help safety management of DCU.
Journal of the Korea Institute of Information Security & Cryptology
/
v.21
no.4
/
pp.125-136
/
2011
The vulnerabilities existed in Korean electricity control systems is unexposed because it is being operated in a closed network with superior security. The threat will become greater once the closed network develops into a smart grid environment with superior intelligence. Security will have a greater impact once each household will be connected to the power plant via the smart meter. This research focuses on stable data transfer in harsh external environment and whole-nation coverage network, and suggested standardized and optimized Virtual Private Network (VPN) Gateway architecture to support Power Line Communication (PLC). The functionality and stability of the prototype has been verified with field tests. For implementation of outdoor type VPN device for smart grid, we adopted PLC low voltage remote-meter-net for data communication. Also, IPSec type tunneling and ARIA algorithm based encryption of data collected by PLC low voltage remote meter is transmitted.
Journal of Korea Society of Industrial Information Systems
/
v.28
no.5
/
pp.41-54
/
2023
Smart grid that supports efficient energy production and management is used in various fields and industries. However, because of the environment in which services are provided through open networks, it is essential to resolve trust issues regarding security vulnerabilities and privacy preservation. In particular, the identification information of smart meter is managed by a centralized server, which makes it vulnerable to security attacks such as device stolen, data forgery, alteration, and deletion. To solve these problems, this paper proposes a blockchain based authentication protocol for a smart meter. The proposed scheme issues an unique decentralized identifiers (DIDs) for individual smart meter through blockchain and utilizes a random values based on physical unclonable function (PUF) to strengthen the integrity and reliability of data. In addition, we analyze the security of the proposed scheme using informal security analysis and AVISPA simulation, and show the efficiency of the proposed scheme by comparing with related work.
This paper studies the security module for the reliable transmission of the meter reading and the control data between the remote terminals and the upper server-side in smart water grid. The proposed security module was implemented to make it attachable to the remote terminal without security function. In particular, unlike the smart grid of electric field, the low power is considered due to the use of battery power in the smart water grid, and the ARIA-GCM-128 symmetric key method is adopted taking into the account that the damp and constrictive environments by the installed meter location in the underground occur a communication obstacle on building of the large-scale network system. The encryption module of this paper was devised to ensure the safety between the reading data on the terminal and the control data from the upper server, and secure the stability of the remote meter reading system by taking protection against an arbitrary alteration or modification.
The Journal of the Korea institute of electronic communication sciences
/
v.8
no.10
/
pp.1485-1490
/
2013
The demonstration project of the electrical grid for Smart grid is progressed, the smart digital appliances AV technology, Smart home energy management technology charging the management function of complex energy for the automation management of air conditioning and heating, humidity and air, the health care technology charging the design of housing for the elderly and disabled and the measurement of individual bio information, and the Smart home security technology dealing with the biometric security and motion sensors, etc. have been studied. The power monitoring terminal which uses a variety of wired and wireless networks and protocol is the target additionally to be considered in addition to the security vulnerabilities that was occurred in the existing terminal. In this research paper, the author analyzes the cryptographic techniques corresponding to the smart meter occurred by the problems that are exposed on the outside which are vulnerable to physical attacks, and intends to propose the design of the security systems for the Smart meter terminal being able to maximize the efficiency of the terminal.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.