• 제목/요약/키워드: secondary beam

검색결과 302건 처리시간 0.025초

Finite element analysis of ratcheting on beam under bending-bending loading conditions

  • Sk. Tahmid Muhatashin Fuyad;Md Abdullah Al Bari;Md. Makfidunnabi;H.M. Zulqar Nain;Mehmet Emin Ozdemir;Murat Yaylaci
    • Structural Engineering and Mechanics
    • /
    • 제89권1호
    • /
    • pp.23-31
    • /
    • 2024
  • Ratcheting is the cyclic buildup of inelastic strain on a structure resulting from a combination of primary and secondary cyclic stress. It can lead to excessive plastic deformation, incremental collapse, or fatigue. Ratcheting has been numerically investigated on a cantilever beam, considering the current study's primary and secondary bending loads. In addition, the effect of input frequency on the onset of ratcheting has been investigated. The non-linear dynamic elastic-plastic approach has been utilized. Analogous to Yamashita's bending-bending ratchet diagram, a non-dimensional ratchet diagram with a frequency effect is proposed. The result presents that the secondary stress values fall sequentially with the increase of primary stress values. Moreover, a displacement amplification factor graph is also established to explain the effect of frequency on ratchet occurrence conditions. In terms of frequency effect, it has been observed that the lower frequency (0.25 times the natural frequency) was more detrimental for ratchet occurrence conditions than the higher frequency (2 times the natural frequency) due to the effect of dynamic displacement. Finally, the effect of material modeling of ratcheting behavior on a beam is shown using different hardening coefficients of kinematic hardening material modeling.

Interface characteristics of RC beams strengthened with FRP plate

  • Peng, Minglan;Shi, Zhifei
    • Structural Engineering and Mechanics
    • /
    • 제18권3호
    • /
    • pp.315-330
    • /
    • 2004
  • A four-point bending RC beam strengthened with FRP plate is investigated based on the theory of elasticity. Taking the adhesive layer into account but ignoring some secondary parameters, the analytical solutions of the normal stress and shear stress on concrete-adhesive interface are obtained and discussed. Besides, the pure bending region of the beam is analyzed and the ultimate load of the beam is predicted. The results obtained in the present paper agree very well with both the results of FEM and the experimental findings.

Optimized Location Selection of Active Mounting System Applied to 1D Beam Structure

  • Kim, Byeongil
    • 한국산업융합학회 논문집
    • /
    • 제25권4_1호
    • /
    • pp.505-511
    • /
    • 2022
  • The objective of this article is finding optimized locations of active mounts applied to 6-DOF beam structure with two active paths. When sinusoidal excitation forces are applied to the beam structure, secondary forces from two active mounts which can minimize (ideally becoming zero) transmitted forces are calculated mathematically and the vibration attenuation performance is validated through computer simulations. When the force applied to two active mounts are relatively low, those specific locations are considered as optimized location of active mounting system. As the location of mount changes, amplitude and phase of secondary forces in each path are analyzed with 3D plots. Based on the simulation results, a criterion for selecting mounting location is suggested and it would be very useful for selecting actuators for active mounts appropriately.

Feasibility Test of Flat-Type Faraday Cup for Ultrahigh-Dose-Rate Transmission Proton Beam Therapy

  • Sang-il Pak;Sungkoo Cho;Seohyeon An;Seonghoon Jeong;Dongho Shin;Youngkyung Lim;Jong Hwi Jeong;Haksoo Kim;Se Byeong Lee
    • 한국의학물리학회지:의학물리
    • /
    • 제33권4호
    • /
    • pp.108-113
    • /
    • 2022
  • Purpose: Proton therapy has been used for optimal cancer treatment by adapting its Bragg-peak characteristics. Recently, a tissue-sparing effect was introduced in ultrahigh-dose-rate (FLASH) radiation; the high-energy transmission proton beam is considered in proton FLASH therapy. In measuring high-energy/ultrahigh-dose-rate proton beam, Faraday Cup is considered as a dose-rate-independent measurement device, which has been widely studied. In this paper, the feasibility of the simply designed Faraday Cup (Poor Man's Faraday Cup, PMFC) for transmission proton FLASH therapy is investigated. Methods: In general, Faraday cups were used in the measurement of charged particles. The simply designed Faraday Cup and Advanced Markus ion chamber were used for high-energy proton beam measurement in this study. Results: The PMFC shows an acceptable performance, including accuracy in general dosimetric tests. The PMFC has a linear response to the dose and dose rate. The proton fluence was decreased with the increase of depth until the depth was near the proton beam range. Regarding secondary particles backscatter from PMFC, the effect was negligible. Conclusions: In this study, we performed an experiment to investigate the feasibility of PMFC for measuring high-energy proton beams. The PMFC can be used as a beam stopper and secondary monitoring system for transmission proton beam FLASH therapy.

초근접 LED 2차 렌즈의 설계 변수에 관한 연구 (Study on Design Parameters of LED Secondary Lens with Very Close Range)

  • 김장윤;현동훈;홍철의
    • 한국생산제조학회지
    • /
    • 제24권2호
    • /
    • pp.217-223
    • /
    • 2015
  • In this paper, the performance of a system was analyzed according to the design parameters of a LED secondary lens that can be applied at a very close range, e.g., for direct lighting or display systems. We designed the secondary lens of the very-close-range LED using an aspheric equation and analyzed its performance-particularly the angle of the beam spread, central luminous intensity, and light uniformity-with respect to the thickness of lens, radius, conic constant, and asphericity (4th). Our analysis shows that four parameters affect the performance. The simulation results indicate an optimal thickness of 1 mm and show that a larger radius yields higher performance. The optimal range for the conic constant was determined as -1.21 to -1.25, the optimal range for the asphericity was determined as 0.0047xx to 0.0049xx (4th).

이차이온 질량분석기를 이용한 탄탈 박막내의 불순물 분석 (Impurity analysis of Ta films using secondary ion mass spectrometry)

  • 임재원;배준우
    • 한국진공학회지
    • /
    • 제13권1호
    • /
    • pp.22-28
    • /
    • 2004
  • 본 논문은 탄탈 박막의 증착시 음의 기판 바이어스에 의한 탄탈 박막내의 불순물 농도변화에 대해서 고찰하였다. 탄탈 박막은 실리콘 기판 위에 이온빔 증착장비를 이용하여 기판 바이어스를 걸지 않은 경우와 -125 V의 기판 바이어스를 건 상태에서 증착하였다. 탄탈 박막내의 불순물 농도를 관찰하기 위해서 이차이온 질량분석기(secondary ion mass spectrometry)를 이용하였다. 세슘 클러스터 이온에 의한 깊이분석에서, -125 V의 기판 바이어스를 걸어줌으로써 산소, 탄소, 그리고 실리콘 불순물의 농도가 기판 바이어스를 걸지 않은 경우에 비해 상당히 감소한 것을 알 수 있었다. 또한, 세슘 이온빔과 산소 이온빔을 이용한 전체 불순물의 농도분포에서도, 음의 기판 바이어스가 박막 증착시 각각의 불순물 농도에 영향을 준다는 결과를 얻었고 이에 대한 고찰을 하였다.

6 MV X-선 빔을 사용하는 치료실에 설치되는 직접 차폐식 도어의 차폐 두께 계산식 (Calculation Formula for Shielding Thickness of Direct Shielded Door installed in Treatment Room using a 6 MV X-ray Beam)

  • 박철서;김종언;강은보
    • 한국방사선학회논문지
    • /
    • 제14권5호
    • /
    • pp.545-552
    • /
    • 2020
  • 이 연구의 목적은 NCRP 보고서 151과 IAEA 안전 보고서 시리즈 47 기반으로 직접차폐식 도어의 납 두께 계산식을 유도하는 데 있다. 직접차폐식 도어에서 선량률 계산식을 유도한 후, 이 식을 납 차폐 두께 계산식에 대입하여 도어에서 차폐 두께 계산식을 유도하였다. 유도된 직접차폐식 도어의 차폐 두께 계산식으로부터 계산된 납 차폐 두께는 NCRP 및 IAEA 2차 방벽 차폐 두께 계산 방법으로 산출된 두께보다 약 6% 낮았다. 이 결과는 NCRP 및 IAEA 2차 방벽 차폐 두께 계산 방법으로부터 두께 계산이 더 보수적이고 2차 빔 차폐에 잘 맞는다는 의미로 해석된다. 결론적으로, 이 연구에서 유도된 직접차폐식 도어의 납 차폐 두께 계산식은 도어의 차폐 설계에 유용하게 사용될 수 있을 것으로 사료된다.

Diagnostic performance of cone-beam computed tomography on detection of mechanically-created artificial secondary caries

  • Charuakkra, Arnon;Prapayasatok, Sangsom;Janhom, Apirum;Pongsiriwet, Surawut;Verochana, Karune;Mahasantipiya, Phattaranant
    • Imaging Science in Dentistry
    • /
    • 제41권4호
    • /
    • pp.143-150
    • /
    • 2011
  • Purpose : The aim of this study was to compare the diagnostic accuracy of cone-beam computed tomography (CBCT) images and bitewing images in detection of secondary caries. Materials and Methods : One hundred and twenty proximal slots of Class II cavities were randomly prepared on human premolar and molar teeth, and restored with amalgam (n=60) and composite resin (n=60). Then, artificial secondary caries lesions were randomly created using round steel No. 4 bur. The teeth were radiographed with a conventional bitewing technique and two CBCT systems; Pax-500ECT and Promax 3D. All images were evaluated by five observers. The area under the receiver operating characteristic (ROC) curve ($A_z$) was used to evaluate the diagnostic accuracy. Significant difference was tested using the Friedman test (p value<0.05). Results : The mean $A_z$ values for bitewing, Pax-500ECT, and Promax 3D imaging systems were 0.882, 0.995, and 0.978, respectively. Significant differences were found between the two CBCT systems and film (p=0.007). For CBCT systems, the axial plane showed the greatest $A_z$ value. Conclusion : Based on the design of this study, CBCT images were better than bitewing radiographs in detection of secondary caries.

대면적 COB-type LED 패키지를 포함한 LED 램프의 좁은 광속각 구현을 위한 2차 광학계 최적 설계 (Optimal Design of Secondary Optics for Narrowing the Beam Angle of an LED Lamp with a Large-Area COB-type LED Package)

  • 김봉준;김대찬;오범환;박세근;김봉호;이승걸
    • 한국광학회지
    • /
    • 제25권2호
    • /
    • pp.78-84
    • /
    • 2014
  • 본 논문에서는 직경이 14.5 mm인 대면적 COB-type LED 패키지를 사용하면서도 15도 이내의 좁은 광속각을 구현하기 위해, 광학계 크기를 축소하고 동시에 satellite ring 발생을 억제할 수 있는 이중 반사경 구조를 고안하여 조명광학계용 2차 광학계를 최적 설계하였다. 최적 설계를 위해 광원 크기와 제 1 반사경의 광속각 관계를 이용하였고, satellite ring 발생을 억제하기 위한 제 2 반사경의 최적 위치 및 크기를 고려하였다. 그 결과 대체 상용 제품의 크기 제한을 만족하며 80%의 광속 효율을 달성할 수 있었다.

다양한 전자선 전류 조건에서 조사된 폴리에틸렌 분리막의 특성 연구 (A Study on Characterization of Polyethylene Separators Irradiated at Various Electron Beam Current Conditions)

  • 임종수;손준용;신준화;임윤묵;최재학;김정수;노영창
    • 폴리머
    • /
    • 제34권1호
    • /
    • pp.74-78
    • /
    • 2010
  • 본 연구에서는 다양한 전류조건하에 전자선 조사로 가교된 리튬 이차전지용 폴리에틸렌 분리막을 제조하였다. 제조된 폴리에틸렌 분리막의 가교율은 조사량이 증가할수록 그리고 빔 전류가 낮을수록 증가하여 최대 71%까지 증가하였다. 낮은 빔 전류에서 조사된 폴리에틸렌 분리막은 상용 분리막 보다 우수한 열수축률(51%) 및 기계적 특성을 보여주었다. 가교된 분리막의 이온전도도는 $1.01{\times}10^{-3}\;S/cm$와 전해액 함침률(275%)은 조사되지 않은 분리막과 거의 동일하였다.