• Title/Summary/Keyword: second projection method

Search Result 114, Processing Time 0.022 seconds

Collision-Free Path Planning of Articulated Robot using Configuration Space (형상 공간을 이용한 다관절 로보트의 충돌 회피 경로 계획)

  • Kim, J.H.;Choi, J.S.;Kang, H.Y.;Kim, Dong-Won;Yang, S.M.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.2 no.6
    • /
    • pp.57-65
    • /
    • 1994
  • A collision-free path planning algorithm between an articulated robot and polyhedral obstacles using configuration space is presented. In configuration space, a robot is treated as a point and obstacles are treated as grown forbidden regions. Hence path planning problem is transformed into moving a point from start position to goal position without entering forbidden regions. For mapping to 3D joint space, slice projection method is used for first revolute joint and inverse kinematics is used for second and third revolute joint considering kinematic characteristics of industrial robot. Also, three projected 2D joint spaces are used in search of collision-free path. A proper example is provided to illustrate the proposed algorithm.

  • PDF

Effects of US Monetary Policy on Gross Capital Flows: Cases in Korea

  • CHOI, WOO JIN
    • KDI Journal of Economic Policy
    • /
    • v.42 no.4
    • /
    • pp.59-90
    • /
    • 2020
  • U.S. monetary policy has been claimed to generate global spillover and to destabilize other small open economies. We analyze the effects of certain identified U.S. monetary shocks on gross capital flows in the Korean economy using the local projection method. Consistent with previous results on other small open economies, we initially confirm that U.S. interest rate hikes are dynamically correlated with foreign outflows and residents' inflows. That is, not only are they correlated with withdrawals by foreigners but they are also correlated with those by domestic (Korean) investors. The results are mostly driven by portfolio flows. Second, however, the marginal response to a U.S. monetary policy shock is, on average, subdued if we focus on the sample periods after the Global financial crisis of 2007-2008 (henceforth, global financial crisis). We conjecture a possible reason behind the change, an institutional change related to financial friction. If the degree of pledgeability of the value of net worth increases, the marginal responses by both investors would drop with a U.S. monetary policy shock, consistent with our findings.

The Comparison of Image Quality and Quantitative Indices by Wide Beam Reconstruction Method and Filtered Back Projection Method in Tl-201 Myocardial Perfusion SPECT (Tl-201 심근관류 SPECT 검사에서 광대역 재구성(Wide Beam Reconstruction: WBR) 방법과 여과 후 역투영법에 따른 영상의 질 및 정량적 지표 값 비교)

  • Yoon, Soon-Sang;Nam, Ki-Pyo;Shim, Dong-Oh;Kim, Dong-Seok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.122-127
    • /
    • 2010
  • Purpose: The Xpress3.$cardiac^{TM}$ which is a kind of wide beam reconstruction (WBR) method developed by UltraSPECT (Haifa, Israel) enables the acquisition of at quarter time while maintaining image quality. The purpose of this study is to investigate the usefulness of WBR method for decreasing scan times and to compare to it with filtered back projection (FBP), which is the method routinely used. Materials and Methods: Phantom and clinical studies were performed. The anthropomorphic torso phantom was made on an equality with counts from patient's body. The Tl-201 concentrations in the compartments were 74 kBq (2 ${\mu}Ci$)/cc in myocardium, 11.1 kBq (0.3 ${\mu}Ci$)/cc in soft tissue, and 2.59 kBq (0.07 ${\mu}Ci$)/cc in lung. The non-gated Tl-201 myocardial perfusion SPECT data were acquired with the phantom. The former study was scanned for 50 seconds per frame with FBP method, and the latter study was acquired for 13 seconds per frame with WBR method. Using the Xeleris ver. 2.0551, full width at half maximum (FWHM) and average image contrast were compared. In clinical studies, we analyzed the 30 patients who were examined by Tl-201 gated myocardial perfusion SPECT in department of nuclear medicine at Asan Medical Center from January to April 2010. The patients were imaged at full time (50 second per frame) with FBP algorithm and again quarter-time (13 second per frame) with the WBR algorithm. Using the 4D MSPECT (4DM), Quantitative Perfusion SPECT (QPS), and Quantitative Gated SPECT (QGS) software, the summed stress score (SSS), summed rest score (SRS), summed difference score, end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (EF) were analyzed for their correlations and statistical comparison by paired t-test. Results: As a result of the phantom study, the WBR method improved FWHM more than about 30% compared with FBP method (WBR data 5.47 mm, FBP data 7.07 mm). And the WBR method's average image contrast was also higher than FBP method's. However, in result of quantitative indices, SSS, SDS, SRS, EDV, ESV, EF, there were statistically significant differences from WBR and FBP(p<0.01). In the correlation of SSS, SDS, SRS, there were significant differences for WBR and FBP (0.18, 0.34, 0.08). But EDV, ESV, EF showed good correlation with WBR and FBP (0.88, 0.89, 0.71). Conclusion: From phantom study results, we confirmed that the WBR method reduces an acquisition time while improving an image quality compared with FBP method. However, we should consider significant differences in quantitative indices. And it needs to take an evaluation test to apply clinical study to find a cause of differences out between phantom and clinical results.

  • PDF

The use of digital periapical radiographs to study the prevalence of alveolar domes

  • Xambre, Pedro Augusto Oliveira Santos;Valerio, Claudia Scigliano;Cardoso, Claudia Assuncao e Alves;Custodio, Antonio Luis Neto;Manzi, Flavio Ricardo
    • Imaging Science in Dentistry
    • /
    • v.46 no.3
    • /
    • pp.179-184
    • /
    • 2016
  • Purpose: In the present study, we coined the term 'alveolar dome' and aimed to demonstrate the prevalence of alveolar domes through digital periapical radiographs. Materials and Methods: This study examined 800 digital periapical radiographs in regard to the presence of alveolar domes. The periapical radiographs were acquired by a digital system using a photostimulable phosphor (PSP) plate. The ${\chi}^2$ test, with a significance level of 5%, was used to compare the prevalence of alveolar domes in the maxillary posterior teeth and, considering the same teeth, to verify the difference in the prevalence of dome-shaped phenomena between the roots. Results: The prevalence of alveolar domes present in the first pre-molars was statistically lower as compared to the other maxillary posterior teeth (p<0.05). No statistically significant difference was observed in the prevalence of alveolar domes between the maxillary first and second molars. Considering the maxillary first and second molars, it was observed that the palatal root presented a lower prevalence of alveolar domes when compared to the distobuccal and mesiobuccal roots (p<0.05). Conclusion: The present study coined the term 'alveolar dome', referring to the anatomical projection of the root into the floor of the maxillary sinus. The maxillary first and second molars presented a greater prevalence of alveolar domes, especially in the buccal roots, followed by the third molars and second pre-molars. Although the periapical radiograph is a two-dimensional method, it can provide dentists with the auxiliary information necessary to identify alveolar domes, thus improving diagnosis, planning, and treatment.

Differential Subsampling with Cartesian Ordering Contrast-Enhanced Magnetic Resonance Angiography for the Preoperative Assessment of Anterolateral Thigh Flap

  • Yunfeng Shen;Xiucun Li;Chao Zhang;Hai Zhong;Weiqiang Dou
    • Korean Journal of Radiology
    • /
    • v.23 no.8
    • /
    • pp.803-810
    • /
    • 2022
  • Objective: To investigate the clinical application of differential subsampling with Cartesian ordering (DISCO) contrast-enhanced (CE) magnetic resonance angiography for anterolateral thigh (ALT) flap transplantation, using operative findings as a reference. Materials and Methods: Thirty patients (21 males and nine females; mean age ± standard deviation, 45.5 ± 15.6 years) who were scheduled to undergo reconstruction with ALT flaps between June 2020 and June 2021 were included in the prospective study. Before ALT flap transplantation, patients were scanned using CE-DISCO imaging. All acquired DISCO images of the 60 lower limbs (both sides from each patient) were analyzed using maximum intensity projection and volume rendering methods. Two experienced radiologists were employed to examine the patterns of the lateral circumflex femoral artery (LCFA), its branches, and perforators and their skin termini, which were compared with the operative findings. Results: Using CE-DISCO, the patterns of the LCFA and its branches were clearly identified in all patients. Four different origins of the LCFA were found among the 60 blood vessels: type I (44/60, 73.3%), type II (6/60, 10.0%), type III (8/60, 13.3%), and type IV (2/60, 3.3%). Owing to a lack of perforators entering the skin, two patients did not undergo ALT flap transplantation. For the remaining 28 patients, the ALT flaps in 26 patients were successfully operated without flap reselection during the operation, while the remaining two patients underwent other surgical procedures due to the thin diameter of the perforator or injury of the perforator during the operation. The success rate of flap transplantation was 92.8% (26/28). All transplanted flaps exhibited good blood supply and achieved primary healing without infection or delayed healing. Conclusion: CE-DISCO imaging can be an effective method for preoperative perforator imaging before ALT flap transplantation.

Weigh-in-Motion load effects and statistical approaches for development of live load factors

  • Yanik, Arcan;Higgins, Christopher
    • Structural Engineering and Mechanics
    • /
    • v.76 no.1
    • /
    • pp.1-15
    • /
    • 2020
  • The aim of this paper is to simply present live load factor calculation methodology formulation with the addition of a simple new future load projection procedure to previously proposed two methods. For this purpose, Oregon Weigh-in-Motion (WIM) data were used to calculate live load factors by using WIM data. These factors were calculated with two different approaches and by presenting new simple modifications in these methods. A very simple future load projection method is presented in this paper. Using four different WIM sites with different average daily truck traffic (ADTT) volume, and all year data, live load factors were obtained. The live load factors, were proposed as a function of ADTT. ADTT values of these sites correspond to three different levels which are approximately ADTT= 5,000, ADTT = 1,500 and ADTT ≤ 500 cases. WIM data for a full year were used from each site in the calibration procedure. Load effects were projected into the future for the different span lengths considering five-year evaluation period and seventy-five-years design life. The live load factor for ADTT=5,000, AASHTO HS20 loading case and five-year evaluation period was obtained as 1.8. In the second approach, the methodology established in the Manual for Bridge Evaluation (MBE) was used to calibrate the live load factors. It was obtained that the calculated live load factors were smaller than those in the MBE specifications, and smaller than those used in the initial calibration which did not convert to the gross vehicle weight (GVW) into truck type 3S2 defined by AASHTO equivalents.

Nipple Reconstruction with Dermis(Scar Tissue) Graft and C-V Flap (진피(반흔 조직)이식과 C-V피판을 이용한 유두재건술)

  • Lee, Paik Kwon;Lim, Jee Hyun;Ahn, Sang Tae;Oh, Deuk Young;Rhie, Jong Won;Han, Ki Taik
    • Archives of Plastic Surgery
    • /
    • v.33 no.1
    • /
    • pp.101-106
    • /
    • 2006
  • Nipple reconstruction is an important step in breast reconstruction after mastectomy. The authors' preferred reconstructive technique is the local C-V flap in case that a small opposite nipple is not adequate for composite graft. This flap produces an excellent reconstruction, but it is not easy to produce an adequate projection and firmness of the nipple. This article describes the technique and experience in nine patients treated over two years with dermis(scar tissue) graft for nipple reconstruction. This is the first report of application of autologous dermis(scar tissue) grafting to reconstruct a nipple primarily after breast mound reconstruction, decreasing the absorption of the reconstructed nipple and increasing the hardness. The dermis(scar tissue) is taken from scar revision and/or dog-ear correction in the second stage operation after free TRAM flap breast reconstruction. And the dermis(scar tissue) graft is inserted vertically between the local flaps and horizontally under the reconstructed nipple base. Between September 2002 and February 2005, nine patients underwent C-V flap with dermis(scar tissue) graft as a part of their nipple reconstruction. The patient's ages ranged from 28 to 55 years old (mean, 41.1 years old). The follow-up period ranged from 5 to 35 months, with an average of 14.5 months. None of the nipples showed skin flap necrosis or local infection, and uneventful wound healing. Our result showed good nipple projection with less absorption and enough firmness. Our experiences shows that dermis(scar tissue) grafts in C-V flap is a very useful method for nipple reconstruction.

A Study on the Kinematic Surveying Method Using the Digital Video Recorder (디지털 비디오 리코더에 의한 이동 측량 기법 연구)

  • 함창학;김원대
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.21 no.3
    • /
    • pp.229-236
    • /
    • 2003
  • This study recorded an object using a digital video recorder, and then tried to estimate 3-D positional information and to reconstruct an image. Firstly, the accuracy of measurement results from a video recorder was evaluated and tested for an applicability, then it applied to a real object to construct 3-D digital model. This study assumed that there is no lens distortion in a video recorder, and all bundles should precisely pass through the projection center of a lens. The image size for orientations is determined by the size of CCD chip and the number of pixels. The average squared error from the result by a digital video recorder and that by triangular survey from 1-second theodolite shows 0.0173m error in x,y coordinates. Without knowing the accurate information on the lens distortion and the coordinates of the projection center, this study reasonably produces acceptable results in the reconstruction of 3-D model. In consequence, this study found that the image from a digital video camera can be reconstructed 3-D model only from the information on a camera type.

Correction of Rotated Frames in Video Sequences Using Modified Mojette Transform (변형된 모젯 변환을 이용한 동영상에서의 회전 프레임 보정)

  • Kim, Ji-Hong
    • Journal of Korea Multimedia Society
    • /
    • v.16 no.1
    • /
    • pp.42-49
    • /
    • 2013
  • The camera motion is accompanied with the translation and/or the rotation of objects in frames of a video sequence. An unnecessary rotation of objects declines the quality of the moving pictures and in addition is a primary cause of the viewers' fatigue. In this paper, a novel method for correcting rotated frames in video sequences is presented, where the modified Mojette transform is applied to the motion-compensated area in each frame. The Mojette transform is one of discrete Radon transforms, and is modified for correcting the rotated frames as follows. First, the bin values in the Mojette transform are determined by using pixels on the projection line and the interpolation of pixels adjacent to the line. Second, the bin values are calculated only at some area determined by the motion estimation between current and reference frames. Finally, only one bin at each projection is computed for reducing the amount of the calculation in the Mojette transform. Through the simulation carried out on various test video sequences, it is shown that the proposed scheme has good performance for correcting the rotation of frames in moving pictures.

TSSG growth, morphology and properties of potassium lithium niobate (KLN) crystals

  • Chong, Tow-Chong;Xu, Xue-Wu;Lian Li;Zhang, Guang-Yu;H. Kumagai;M. Hirano
    • Proceedings of the Korea Association of Crystal Growth Conference
    • /
    • 1999.06a
    • /
    • pp.167-185
    • /
    • 1999
  • In the present paper, KLN crystals have been grown along <001>, <100> and <110> directions by the top seeded solution growth (TSSG) method from Li-richer melts with different compositions. The morphologies of KLN crystals grown along different directions have been studied, and the well-developed facets have been unambiguously indexed using X-ray goniometer and stereographic projection analysis. The growth mechanism and defects such as cracks and inclusions were discussed on the basis of observations of facets on the crystal-melt interfaces. The crystal compositions were determined by chemical analysis method. The structure and lattice constants of KLN crystals were determined and calculated on the basis of XRD data by using TREOR90 and PIRUM programs. The Curie temperature and optical absorption were determined by dielectric constant peak and spectrum measurements, respectively. The blue SHG characteristics of a KLN sample were also investigated using a pulsed dye laser. PACS: 42.70.M;81.10;81.10A;42.65.K.

  • PDF