• Title/Summary/Keyword: sealed

Search Result 783, Processing Time 0.026 seconds

Surgical Treatment of Emphysematous Bullae (기낭성 폐기종의 외과적 치료)

  • 김형묵
    • Journal of Chest Surgery
    • /
    • v.6 no.2
    • /
    • pp.165-170
    • /
    • 1973
  • The selection and treatment with resection and drainage for patients with emphysematous bullae is discussed with reference to two patients recently. One case with bilateral multiple bullous emphysema resulting tension pneumothorax due to rupture of the bullae on right, 47 year old man with pulmonary tuberculosis history for 16 years, was treated with resection of the bullae on right including upper lobectomy and c!osed rhoracostomy drainage on left for another spontaneous pneumothorax, and result was excellent for 6 month after discharge. Another 53 year old man with giant tension air cysts occupying right whole lung field and shifting mediastinum to the left was treated with right under water sealed closed thoracostomy drainage for 7 days in vain, and resection was not performed for his poor respiratory function and general condition. The most useful preoperarive information was obtained from a study of the plain chest radiogram and the surgical procedure of choice was obliteration of the bullae at thoracotomy.

  • PDF

A Study on the Behavior of Chloride Ion in Hardened Cement Paste at Defferent Stages of Curing (재령에 따른 시멘트 경화체내 염화물 이온의 거동에 관한 연구)

  • 문소현;소승영;소양섭
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10c
    • /
    • pp.185-190
    • /
    • 1998
  • Corrosion of steel reinforcement is the most significant factor of deterioration in reinforced concrete structures. Chloride ion is considered one of the most common culprits on the corrosion of steels in concrete. The main objective of this study is understanding behavior of chloride ion in hardened cement pastes at different stages of curing. Cement pastes with water-cement ratio of 0.5 are allowed to hydrate in sealed containers for 28, 70, 180 days. And than pore solution is expressed. It was found that the $Cl^-$ concentrations in pore solution is decreased with increasing curing time in all Nacl addition level, the $OH^-$ concentrations is increased to 70 days but decrease at 180 days in all Nacl addition level. The $Cl^-$/$OH^-$ in pore solution is increased with increasing curing time in all Nacl addition level, however $Cl^-$/$OH^-$ of maximum Nacl addition level(Nacl 0.54% by weight of cement) is under the onset of depassivation level 0.3.

  • PDF

Behavior of Chloride Binding in Hardened Cement Pastes (Forcused on $C_3A$ content) (시멘트 경화체내 염화물의 고정화 성상 ($C_3A$ 함유량을 중심으로))

  • 임순지;소형석;소승영;박홍신;소양섭
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1994.10a
    • /
    • pp.87-92
    • /
    • 1994
  • The main objective of this study is to determine the critical chloride ion concentrations in the pore solutions causing depassivation of steel reinforcement in concrete made with cements of different $C_3A$ contents. Cement pastes with water-ratio of 0.5 were prepared using four cements with $C_3A$ contents of 0.46, 5.97, 9.14, and 9.65 percent. The pastes were allowed to hydrate in sealed containers for 28days and then objected to pore solution expression. The expressed pore fluids were analyzed for chloride and hydroxyl ion concentrations. It was found that the free cholride concentration in the pore solution decreases significantly with an increase in the $C_3A$ content of the cement. With increasing level of chloride addition, although the alsolute amount of bound chloride increase, the ratio of bound to total chlorides decreases.

  • PDF

Chloride Binding Capacity of Fly Ash Cement Pastes. (플라이 애쉬 첨가 시멘트 페이스트외 염화물 고정화율)

  • 이순지;소형석;소승영;소양섭
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1995.04a
    • /
    • pp.106-110
    • /
    • 1995
  • Chloride ion is considered one of the most common culprits in the corrosion of steel in concrete. It breaks down the passive film and allows the steel to corrode actively at a high rate. The main objective of this study is to determine the critical chloride ion concentrations in the pore solutions and chloride binding effect of cement pastes made with and without fly ash. Cement pastes with water-ratio of 0.5 allowed to hydrate in sealed containers for 28 days and to express poresolution. T도 expressed pore fluids were analyzed for chloride and hydroxyl ion concentrations. It was found that the replaced cement with fly ash have little effect on Chloride binding capacity ratio.

  • PDF

Storage of Waste-Brown Seaweed and Degradation of Alginate Using Microorganism (미생물을 이용한 미역폐기물의 저장 및 알긴산염 저분자화)

  • An, Sang Jun;Kim, Yeong Suk;Park, Gwon Pil
    • Journal of Environmental Science International
    • /
    • v.13 no.3
    • /
    • pp.313-318
    • /
    • 2004
  • We studied a storage of waste-brown seaweed at room temperature and degradation of alginate in seaweed by microorganism DS-02. The seaweeds, mixed with 5.0 wt% DS-02 and sealed in vinyl package without any other treatment, could be stored longer than 1 year without spoilage at room temperature. During the storage process, the alginate of seaweed was decomposed by enzyme of DS-02 and the molecular weight of alginate decreased to about 1/10 of initial quantity. DS-02 growed as fast as it had maximum weight after 24 hour culture and it's enzyme had a maximum activity of alginate degradation at $40^{\circ}C.$ The seaweed sample became particles in DS-02 culture solution and the M. W of alginate decreased to about 1/10 of initial value after 24 hour decomposition. The effect of alginate degradation with DS-02 was similar to that of degradation with 3.0 M HCI solution for 24 hour.

Development of the Ultrasonic Transducers for the Degradation of TCE in Aqueous Solution (수중 TCE 분해용 압전 초음파 트랜스듀서 개발)

  • Lee, Youngjin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.11
    • /
    • pp.753-759
    • /
    • 2014
  • This paper describes the development of a piezoelectric flextensional transducer, which aims to effectively degrade the TCE contained in aqueous solution. In order to adjust the 1st flextensional resonant frequency and output displacement of the flextensional transducer, the effect of the geometrical variations on performance was analyzed using the finite element analysis (FEM). The results indicated that the effect of external shell's thickness and curvature were most significant, and experimental fabrication and characterization of a transducer was performed to confirm the results. To prove the capacity to degrade the TCE contained in aqueous solution, 50 and 100 ppm of TCE were prepared in sealed chamber, and investigated the removal rate of TCE through the time and initial concentration.

Computational and Experimental Investigation on U-type Seal of Hydraulic Actuator (유압액추에이터용 U자형 시일의 해석 및 실험적 고찰)

  • Yoo, Myung-Ho;Kwon, Jong-Ho;Lee, Taek-Sung
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.12 s.189
    • /
    • pp.80-87
    • /
    • 2006
  • Seals are usually made from elastomer, a kind of rubber, and it has the non-linearity and hyper-elasticity. U-type seals are used to prevent the leakage of internal fluid sealed in hydraulic actuator because they have more excellent performance than O-rings or rectangular seals. As a core part of hydraulic actuator, U-type seal gives much effect on performance and reliability of actuator. This study considers an NBR U-type seal under high pressure of a hydraulic actuator, and provides its deformation, stress-strain characteristic and contact force using the non-linear finite element analysis. Analysis results are compared with the experimental ones performed by the self-developed testing equipment. Verification result shows that this study presents a good application process for the effective design of U-type seals under high operation pressure.

Development of the calibration system for very accurate thermometers at low temperatures (초정밀 온도센서의 저온 영역 교정 장치 개발)

  • Yang, In-Seok;Song, Chang-Ho;Kang, Kee-Hoon;Kim, Yong-Gyoo
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.3
    • /
    • pp.188-194
    • /
    • 2008
  • For the accurate calibrations of thermometers at low temperatures, triple points of oxygen and argon have been realized using sealed-type triple point cells. The triple points were realized with both adiabatic and continuous heating methods. The resistance of three capsule-type standard platinum resistance thermometers were measured at the triple points of oxygen, argon, mercury and water for the calibrations of these thermometers in the range from $-220^{\circ}C$ to $0.01^{\circ}C$. The extended uncertainty, with the coverage factor of 2, of the calibration in this range is smaller than 1 mK.

Development and Evaluation of a Carbon Dioxide Diffusive Sampling Method using Barium Hydroxide (수산화바륨을 이용한 이산화탄소 확산측정법의 개발 및 평가)

  • Yim, Bongbeen
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.1
    • /
    • pp.56-63
    • /
    • 2013
  • This study was aimed at developing and evaluating a diffusive sampling method using a barium hydroxide solution as an absorbent for measuring carbon dioxide ($CO_2$) in ambient air. The collected $CO_2$ concentration was calculated by the change of conductivity resulted in the reaction of $CO_3{^{2-}}$ and $Ba^{2+}$ in aqueous solution. The sampling rate for the diffusive sampler was determined 0.218 mL/min, as obtained from the slope of the linear correlation between the $CO_2$ mass collected by the diffusive sampler and the time-weighted $CO_2$ concentration with the active sampling method. The unexposed blank sampler sealed in aluminium foil-polyethylene laminated packets has remained stable during at least one-month storage period. A good correlation was observed between the diffusive sampler and active sampler with a coefficient of determination of 0.956. This diffusive sampler would be suitable for the indoor $CO_2$ concentration monitoring.

Dependence of Xe Plasma Flat Fluorescent Lamp On the Electrode Gap and Dielectric Layer Thickness

  • Kang, Jong-Hyun;Lee, Yang-Kyu;Heo, Sung-Taek;Oh, Myung-Hoon;Lee, Dong-Gu
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08b
    • /
    • pp.1519-1521
    • /
    • 2007
  • In this work, a coplanar-type plasma flat fluorescent lamp having cross type of electrode was fabricated by screen printing and sealing technique. Cross type of electrode with a dielectric layer were screen-printed on a rear glass plate, and then fired at $550^{\circ}C$. Phosphor was printed on and fired at $450^{\circ}C$. Finally, the lamp was sealed by frit glass at $450^{\circ}C$. The lamp of cross electrode type was studied depending on the electrode gap and the thickness of dielectric layer.

  • PDF