• Title/Summary/Keyword: screw anchor

Search Result 25, Processing Time 0.025 seconds

The Method of Estimating Group Effect with Small Pull-out Tests of Screw Anchors (나선형 앵커의 실내인발시험을 이용한 무리효과 평가기법)

  • Park Si-Sam;Lee Hyung-Kyu
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.10
    • /
    • pp.123-131
    • /
    • 2005
  • In the present study, laboratory pull-out tests with screw anchors are carried out to investigate behavior characteristics of the anchors used in foundation system of underground structures which are applied to uplifting seepage forces. Small scaled pull-out tests in sand under saturated condition and dry condition were carried out. For estimating the group effects of the anchors, the upward displacement and the pullout load varied with spacing of the anchor were observed. The test results were compared with theoretical equation for the ultimate pull-out force. Also, the result of tests can be used to the finite element analysis program, $PENTAGON^{2D}$.

Development of an ACL Anchor: Effects of the Design Parameters on the Performance of a New Anterior Cruciate Ligament Fixation Device

  • Kim, Jong-Dae;Oh, Chae-Youn;Kim, Cheol-Sang
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.2
    • /
    • pp.132-138
    • /
    • 2008
  • We investigated the biomechanical properties of a newly designed self-expansion type anterior cruciate ligament (ACL) anchor. The ACL anchor consists of the ring section giving the elastic force, the wedge for maintaining in contact with the femur tunnel wall and the link suspending hamstring graft or artificial ligament. The main design parameters that determine the performance of this device were the expansion angle (${\theta}$) and the thickness ($t_R$). The Ti6Al4V anchors were heated after inserting in a jig for 1 hour at $800^{\circ}C$ in a protective argon gas atmosphere and allowed to cool to room temperature in the furnace. In order to investigate the influence of the expansion angle and the thickness of the ring on the biomechanical properties of the anchor, the maximum pull-out load, stiffness and slippage of the ACL anchor were measured using the pull-out tester, and statistical analyses were also executed. The present results showed that the design parameters gave a significant effect on the performance of the self- expansion type of anchor. The pull-out load of the ACL anchors significantly increased as the thickness of the ring section was increased, having a similar trend for both expansion angles. The ACL anchor showed about 2.5 times higher values of the pull-out load than that of the minimum load (500N)required for the "accelerated rehabilitation". The optimum ${\theta}$ and $t_R$ values of this ACL anchor were suggested to have sufficient resistance against the pull-out force, high stiffness and relatively low slippage after ACL reconstruction.

Arthroscopic Cannulated Screw Fixation of Avulsion Fracture of the Intercondylar Eminence of the Tibia in a Child -A Case Report- (소아에서 발생한 전방 십자인대 견열 골절에서 유관 나사못을 이용한 관절경적 정복술 -증례보고-)

  • Moon, Kyu Pill;Kim, Kyung Taek;Kang, Min Soo;Park, Won Ro
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.11 no.1
    • /
    • pp.62-65
    • /
    • 2012
  • Avulsion fractures of the intercondylar eminence of the tibia are uncommon. This kind of fracture is most commonly found in adolescents, with an increasing incidence for those involved in competitive athletics. Recently, an arthroscopic procedure is preferred to reduce the operation-related morbidity. Screws, K-wires, Suture anchor have been described as fixation devices. Cannulated screw fixation is a simple method, but this instrument has the risk of causing damage to the growth plate. The authors report good results using cannulated screw in arthroscopic treatment for pediatric anterior cruciate ligament avulsion fracture.

  • PDF

Widening of Bony Tunnel after ACL Reconstruction Using Hamstring Tendon with Ligament Anchor(LA) Screw (슬괵건 및 LA나사를 이용한 관절경적 전방 십자 인대 재건술 후 골터널의 확장)

  • Song Eun Kyoo;Yoon Taek Rim;Jung Jong Wook;Jeong Kwang Cheul
    • Journal of the Korean Arthroscopy Society
    • /
    • v.5 no.2
    • /
    • pp.69-73
    • /
    • 2001
  • Purpose : To evaluate the clinical results and widening of bony tunnel after anterior cruciate ligament(ACL) reconstruction using hamstring tendon with Ligament Anchor(LA) screw, which is newly designed fur fixation of graft into femur. Materials and Methods : Fifty eight patients who were followed up at least more than 2 years after ACL reconstruction with four strands of Hamstring tendon were included in this study. The graft was fixed with LA screw at femoral tunnel and with bioabsorbable interference screw at tibial tunnel. The average period of follow-up was 28 months. The clinical results such as physical examination and Lysholm knee score and radiological results. widening of bony tunnel and instrumented anterior laxity test with $Telos^{\circledR}$(Telos stress device; Austin & Associates, Inc., Polston, US) were evaluated. Results . The Lysholm knee score was 60.0 in average preoperatively and improved to 94.0 in average at follow up. On the Lachman test, there were mild(+) instability in 16 cases, moderate(++) in 24, severe(+++) in 18 preoperatively. 50 cases were converted to negative and 8 to mild instability at follow up. On instrumented anterior laxity test with $Telos^{\circledR}$, side to side difference in 20 lb was 12.9mm in average preoperatively, and was decreased to 3.1mm in average follow-up. The femoral tunnel was widened from 10.6mm postoperatively to 12.7mm$(21.1\%)$ at follow up on antero-posterior plane and from 10.7mm to 12.4mm$(16.5\%)$ on lateral plane. Tibial tunnels was also widened from 9.8mm to 11.8mm$(20.7\%)$ on antero-posterior plane and from 9.9mm to 11.7mm$(18.9\%)$ in lateral plane. Conclusion : ACL reconstruction with hamstring tendon and LA screw was one of the choice of grafts and fixatives in restoring knee stability and in improving clinical results with little complications such as excessive widening of bony tunnel.

  • PDF

Free Hand Insertion Technique of S2 Sacral Alar-Iliac Screws for Spino-Pelvic Fixation : Technical Note, Acadaveric Study

  • Park, Jong-Hwa;Hyun, Seung-Jae;Kim, Ki-Jeong;Jahng, Tae-Ahn
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.6
    • /
    • pp.578-581
    • /
    • 2015
  • A rigid spino-pelvic fixation to anchor long constructs is crucial to maintain the stability of long fusion in spinal deformity surgery. Besides obtaining immediate stability and proper biomechanical strength of constructs, the S2 alar-iliac (S2AI) screws have some more advantages. Four Korean fresh-frozen human cadavers were procured. Free hand S2AI screw placement is performed using anatomic landmarks. The starting point of the S2AI screw is located at the midpoint between the S1 and S2 foramen and 2 mm medial to the lateral sacral crest. Gearshift was advanced from the desired starting point toward the sacro-iliac joint directing approximately $20^{\circ}$ angulation caudally in sagittal plane and $30^{\circ}$ angulation horizontally in the coronal plane connecting the posterior superior iliac spine (PSIS). We made a S2AI screw trajectory through the cancellous channel using the gearshift. We measured caudal angle in the sagittal plane and horizontal angle in the coronal plane. A total of eight S2AI screws were inserted in four cadavers. All screws inserted into the iliac crest were evaluated by C-arm and naked eye examination by two spine surgeons. Among 8 S2AI screws, all screws were accurately placed (100%). The average caudal angle in the sagittal plane was $17.3{\pm}5.4^{\circ}$. The average horizontal angle in the coronal plane connecting the PSIS was $32.0{\pm}1.8^{\circ}$. The placement of S2AI screws using the free hand technique without any radiographic guidance appears to an acceptable method of insertion without more radiation or time consuming.

Is the Strong Fixation Necessary in Performing Biceps Tenodesis? (이두근 장두 건 고정술시 강한 고정이 필요한가?)

  • Song, Hyun Seok;Choi, Woo Hyuk
    • Clinics in Shoulder and Elbow
    • /
    • v.15 no.2
    • /
    • pp.148-153
    • /
    • 2012
  • Various biceps tenodesis techniques being used, make it difficult to compare the result of reports. First, the biceps tenodesis could be classified according to being performed by open incision or by the arthroscopic procedure. Second, it could be classified as a soft tissue and bony tenodesis according to the tissue which the long head of biceps is fixed with. Third, it could be classified as a proximal and distal tenodesis according to the location which the long head of biceps is fixed with. Fourth, it could be classified according to the implant (interference screw, suture anchor, knotless suture anchor). A decision should be suspended until an appropriate strength of tenodesis is revealed.

Cranioplasty and temporal hollowing correction with a three-dimensional printed bioresorbable mesh and double vertical suture anchor muscle sling: a case report

  • Choi, Jae Hyeok;Roh, Tai Suk;Lee, Won Jai;Baek, Wooyeol
    • Archives of Craniofacial Surgery
    • /
    • v.23 no.4
    • /
    • pp.178-182
    • /
    • 2022
  • Postoperative temporal hollowing is a common complication of craniotomy. Damage and repositioning of the temporalis muscle can lead to a depression in the temporal side of the skull with inferior bulging, worsening aesthetic outcomes. We report a case of cranioplasty with three-dimensional (3D) printed mesh involving an additional correction using a temporalis muscle sling to help address this problem. A 3D-printed bioabsorbable mesh was prepared based on preoperative facial computed tomography, and was fixed to the hollowed area for tissue augmentation. The temporalis muscle was elevated and fanned out to its original position, and a sling was attached to a screw that was fixed to the mesh. For reinforcement, an additional sling was attached to another screw fixed to the mesh 2-3 cm vertically above the first screw. Aesthetic results were confirmed immediately after surgery and later during outpatient follow-up. Both depression and lateral bulging were resolved, and there was no delayed drooping of the temporalis muscle on 6-month follow-up. There were no complications, and the patient was satisfied with the appearance. This is a simple yet effective technique with a low risk of complications, and should be considered for postoperative temporal hollowing patients, especially those with severe lateral bulging.

Arthroscopic Treatment of Greater Tuberosity fracture - Preliminary Report - (상완골 대결절 골절 손상에 대한 관절경적 치료 -예비 보고-)

  • Ji, Jong-Hoon;Kim, Young-Yul;Park, Sang-Eun;Ra, Ki-Hang;Do, Jeong-Hun;Kim, Weon-Yoo
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.6 no.1
    • /
    • pp.57-65
    • /
    • 2007
  • Purpose: The purpose of this study was to evaluate the clinical result of arthroscopic treatments by using suture anchors or suture anchors combined with cannulated screw in the greater tuberosity fracture of the proximal humerus fracture. Materials and Methods: From March 2004 to March 2006 we have used suture anchor or suture anchors combined with cannulated screw for 6 cases of the greater tuberosity fracture which include displaced fractures, comminuted fractures and minimally displaced fractures with comcomittent lesions such as rotator cuff tears, stiffness and labral lesion. In this retrospective study, we analyzed the clinical outcomes by using the range of motion, University of California at Los Angeles shoulder rating scale (UCLA) and the ASES shoulder index score (ASES) in the average 6 months follow up. Results: At the last follow up, average range of motion was improved to 154.3 degree, 145.8 degree, 32.6 degree and L1 vertebrae in each forward flexion, abduction, external rotation and internal rotation. Clinically the UCLA rating scales improved to 31.5 and the ASES shoulder index score (ASES) improved to 93.6 in the last follow up. Conclusion: Arthroscopic treatments by using suture anchor or suture anchors combined with cannulated screw in the greater tuberosity fracture of the proximal humerus fracture is an alternative treatment of the greater tuberosity fracture of the proximal humerus fracture.

  • PDF

Clinical Results of Anterior Cruciate Ligament Reconstruction Using Hamstring Tendon (슬괵건을 이용한 전방십자인대 재건술의 임상적 결과)

  • Song Eun Kyoo;Lee Keun Bae;Shin Sang Gyoo;Kim Hyun Jong
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.1 no.1
    • /
    • pp.21-25
    • /
    • 2002
  • Purpose: To evaluate the clinical results after anterior cruciate ligament (ACL) reconstruction with hamstring tendon and Ligament Anchor (LA) screw, which is newly designed for fixation of graft into femur. Materials and Methods: Fifty eight patients who were followed up at least more than 2 years after ACL reconstruction with four strands of Hamstring tendon and LA screw were included in this study. The graft was fixed with LA screw at femoral tunnel and with only bioabsorbable interference screw at tibial tunnel. The mean follow-up period was 28 months. The clinical results were evaluated by physical examination and Lysholm knee score. Widening of bony tunnel and anterior laxity difference compared with normal side by instrumented anterior laxity test with Telos(R) (Telos stress device; Austin & Associates, Inc., Polston, US) were evaluated. Results: The Lysholm knee score improved from 60.0 points preoperatively to 94.0 points at last follow up. On the Lachman test, there were mild (+) instability in 16 cases, moderate (++) in 24,severe (+++) in 18 preoperatively. 50 cases were converted to negative and 8 to mild instability at postoperative follow up. On instrumented anterior laxity test with Telos(R), difference between normal and affected knee on 20 lb was 12.9 mm in average preoperatively, and was decreased to 3.1mm at last follow-up. The femoral tunnel was widened from 10.6 mm postoperatively to 12.7 mm (21.1$\%$) at follow up on antero-posterior plane and from 10.7 mm to 12.4 mm (16.5$\%$) on lateral plane. Tibial tunnels was also widened from 9.8mm to 11.8mm (20.7$\%$) on antero-posterior plane and from 9.9mm to 11.7 mm ($18.9\%$) on lateral plane. Complications were: anterior knee crepitus in 17 case, quadriceps muscle atrophy(>3 cm) in 6, penetration of screw over the lateral femoral cortex in 5, saphenous nerve paresthesia in 2.Conclusions: ACL reconstruction with hamstring tendon and LA screw was one of the choice of grafts and fixation devices in restoring knee stability and in improving clinical results with little complications such as excessive widening of bony tunnel and anterior knee pain

  • PDF