• Title/Summary/Keyword: screen thickness

Search Result 237, Processing Time 0.027 seconds

A Evaluation of Shielding Deficiency by Means of Gamma Scanning Test (Gamma Scanning Test에 의한 대단위 차폐체의 결함 평가 연구)

  • Lee, B.J.;Seo, K.W.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.14 no.4
    • /
    • pp.228-236
    • /
    • 1995
  • In this paper the method to evaluate shielding deficiency by gamma scanning test was presented and verified theoretically by Monte Carlo code which is one of the best effective method for radiation shielding calculation. The cylindrical shielding model was selected to evaluate shielding deficiency by gamma scanning test. First, the reference shielding according to the design requirement of cask was fabricated specially and reference values were measured with Co-60 source and scintillation detector. As a result with which calculated the reference values, it is shown that maximum deficiency thickness for lead of true cylindrical shielding model was 12mm. To verify this, thickness of lead was calculated by MCNP code and maximum deficiency thickness was 11.6mm. The experimental result obtained by the use of reference shielding was in good agreement with the theoretical result within 4.1%. So, this method can be applied to inspect the shielding ability for great shielding or cask which the radioactive material is used. To perform measurement more exactly, the further work on the development of measuring equipment to display the results on the screen will be required.

  • PDF

A Study on the Image Quality and Patient Dose in Erect Simple Abdomen Radiography (복부 선자세 단순촬영시 화질과 피폭선량에 관한 연구)

  • Kim, Jung-Min;Hayashi, Taro;Ishida, Yuji;Sakurai, Tatsuya
    • Journal of radiological science and technology
    • /
    • v.21 no.1
    • /
    • pp.29-34
    • /
    • 1998
  • The purpose of simple abdomen erect projection is to see the fluid level which indicates gastrointestinal ileus or free air due to perforation. we do not have to insist on low kVp technique in simple abdomen erect position as long as we can detect the fluid level and free air shadow. Therefore, the author tried to decrease patient dose by high kVp technique and to improve the image quality due to motion artifact by reduction of exposure time. [Methods] Experiment 1. * screen/film SRO1000/HRH * exposure factor : $140\;kvp{\pm}5\;kv$ with added filters, 200 mA, 0.01 sec * phantom : Acryles : 15.0 cm(equivalent to 17 cm body thickness) 17.5 cm(equivalent to 21 cm body thickness) 20.0 cm (equivalent to 25 cm body thickness) With the exposure factor for same film density($D=0.8{\pm}0.1$) and with the materials above, we tried to find out entrance skin dose and gonad dose for both male and female. Experiment 2. Burger's phantom radiography were checked to see whether there was any change of image quality according to the kVp and the added filters. Experiment 3. Using rotating meter(self made), we examined the motion artifact and the exposure time limitation. [Results and conculution] 1. Using high voltage technique of 140 kVp with added filter, Skin dose, testicle dose and ovary dose decrease to 89.3%, 47% and 71.4% respectively compare to 70 kVp technique, 2. No great changes of Burger's phantom image has detected as from 70 kVp to 140 kVp and the air hole size of Burger's phantom over 0.028 cc(Diameter 3 mm, hight 4 mm) can be distinghished. 3. 0.01 sec(1 pulse) exposure time is possible in the single phase full wave rectification that why we can quitely reduce the unsharness caused by patient's movement.

  • PDF

Image and Exposure Dose in Accordance with Radiation Quality on Plain Chest Radiography (흉부촬영(胸部撮影)에서 증감지(增感紙)-필름계의 선질변화(線質變化)에 따른 감도(感度)와 화질에 관(關)한 연구(硏究))

  • Kim, Jung-Min;Kim, Dong-Huan;Hayashi, Taro;Ishida, Yuji;Maeda, Mika;Sakura, Tatsuya
    • Journal of radiological science and technology
    • /
    • v.15 no.1
    • /
    • pp.65-78
    • /
    • 1992
  • Routine chest radiography is generally imaged by high voltage technique but some radiological technologists use low voltage for imaging. High voltage is usually said between $120\;kV{\sim}140\;kV$. Some RTs like using heavy filtration but others seldom like using it. However which is better for use calcium tungustate film screen system or ortho system and high contrast film or wide latitude c-type film for the exculusive use of chest radiography. We could not make a decision which is ideal method for use. In my opinion any method is not always exellent for chest radiography. In my experiments that I had at Kaken hospital in Japan last year I expect to keep the balance between image quality and diagnostic range and to reduce radiation dose for patients. My experiments are as follows. 1. We have looked into system characteristics(speed and contrast) in accordance with kVp($80{\sim}140$) and added filter($no{\sim}1/16\;VL$) in three screen film systems(BX3+CRONEX4, SRO750+MGH, SRO750+MGL). 2. We have looked into skin dose and film dose with same D=1.8 lung field density in accordance with kVp($80{\sim}140$) and added filter($no{\sim}1/16\;VL$) in three screen film systems. 3. We have compared with the evaluation between correlation of physical image quality(MTF) and optical diagnostic capability. Result are follows. 1. Speed of BX3+CRONEX4 became higher in accodance with kVp and thickness of filter but speed of ortho system was not as like regular system. Thicker filter diminished the speed over 100 kV range in SRO750+MGL. In case of SRO750+MGH speed of 1/16VL filter was looked into lower than speed of 1/4VL filter. Sensitivity of ortho system depends on tube voltage and added filter. 2. Skin dose has been detected $225\;{\mu}Gy{\sim}66\;{\mu}Gy$ in BX3+CRONEX4 from 80 kV, no filter to 140 kV, 1/16VL filter. SRO750+MGH could reduce the patient dose $1/2{\sim}1/3$ level in comparison to that of BX3+CRONEX4. 3. The higher kV was the worse MTF became the thicker filter was the worse MTF became too. MTF of BX3+CRONEX4 was detected better than MTF of SRO750+MGH but SRO750+MGH's optical detectability of small lesion in lung field came out better than that of BX3+CRONEX4. Conclusion Recently routine chest radiography is generally imaged by high voltage but it seems to be there are some questions in using of film screen combination. In high voltage chest radiography the subject contrast will come down that means latitude become wider. In this case if we select the low contrast film screen system(C or L type) the film contrast will fall down extremly and detectability of small lesion will be deteriorated. Wide latitude C, L type film has a merit of high detectability on mediastinum. Furthermore high contrast film screen system has the advantage to keep the high contrast in low density region as like mediastinum and heart shadow. Therefore in low subject contrast high voltage chest radiography we would rather choose the high contrast film screen system(H type) I think. From a view point of patient dose detectability of mediastinum and lung field. The optimum technical facter was found out 120 kV, 1/16VL filter : BX3+CRONEX4, 140 kV, 1/4VL filter : SRO750+MGH, 100 kV, 1/4VL filter : SRO750+MGL.

  • PDF

Microsturcture Control of Metallized Alumina Ceramics for Electronic Devices (전자부품용 메탈라이즈드 알루미나 세라믹스의 미세구조 제어)

  • Jo, Beom-Rae
    • Korean Journal of Materials Research
    • /
    • v.11 no.12
    • /
    • pp.1086-1090
    • /
    • 2001
  • Composition effects on microstructure and metallizing properties of the alumina sintered body were evaluated to develop the metallized alumina tubes having superior properties for electronic devices. SEM observation revealed that resultant micrographs and fractographs were varied with composition chance of additives and $SiO_2$-rich specimens showed better microstructural characteristics with uniform distribution of fine and round particles than other CaO-rich or MgO-rich ones. The resultant interfacial microstructure of the $SiO_2$-rich metallized alumina tubes also showed good metallizing properties with no defects between layers and uniform thickness of metallizing layer.

  • PDF

Development of Bonded Wafer Analysis System (본딩 웨이퍼 분석 시스템 개발)

  • Jang, Dong-Young;Ban, Chang-Woo;Lim, Young-Hwan;Hong, Suk-Ki
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.9
    • /
    • pp.969-975
    • /
    • 2009
  • In this paper, bonded wafer analysis system is proposed using laser beam transmission; while the transmission model is derived by simulation. Since the failure of bonded wafer stems in void existence, transmittance deviations caused by the thickness of the void are analyzed and variations of the intensity through the void or defect easily have been recognized then the testing power has been increased. In addition, large screen display on laser study has been done which resulted in acquiring a feasible technique for analysis of the whole bonding surface. In this regard, three approaches are demonstrated in which Halogen lamp, IR lamp and laser have been tested and subsequently by results comparison the optimized technique using laser has been derived.

Annealing Characteristic of Bi-2212 thick Films on Y2l1 substrate (Y211 기판 위의 Bi-2212 후막의 후열처리 특성)

  • Kang, Hyeong-Gon;Lim, Sung-Hun;Chong, Dong-Chul;Lim, Sung-Woo;Han, Byoung-Sung
    • 한국초전도학회:학술대회논문집
    • /
    • v.9
    • /
    • pp.296-299
    • /
    • 1999
  • Bi$_2Sr_2CaCu_2O$(Bi-2212) thick films were fabricated on Y2l1 substrate by screen printing method. And the samples were annealed in various atmospheres, respectively. Though samples had many voids, the sample annealed in N$_2$ ; O$_2$ = 1:0 atmosphere and the sample in N$_2$ : O$_2$ = 0:1 showed some Bi 2212 low phase in comparison to other samples. The thickness of Bi-2212 on Y2ll substrates was about 20 ${\mu}$m.

  • PDF

Study on Multilayer Chip Inductor (적층 칩 인덕터에 관한 연구)

  • Kim, Kyung-Young;Lee, Jong-Kyu;Kim, Wang-Sup;Choi, Hwan
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.28A no.11
    • /
    • pp.880-886
    • /
    • 1991
  • Multi-layered chip inductors were prepared with good magnetic properties by sintering Ni-Zn-Cu ferrites at a lower temperature. A slurry with 49.5mol%Fe$_{2}O_{3}$, 20.5mol% ZnO, 20mol% NiO and 10nol% CuO was cast into tapes with 60-100\ulcorner of thickness with a doctor blade techniques. The tapes were screen-pronted with 100% silver electrodes, layered and pressed at 250kg/cm$^{2}$ and then sintered ant 900$^{\circ}C$ for 2h. Inductance with internal electrodes printed 5, 10, and 15 turns showed 4.9, 15 and 24$\mu$, respectively, at 1MHz.

  • PDF

The Design of Glass for Vixlim

  • Bae, Joon-Soo;Kim, Jeong-Hoon;Kim, Jong-Heon;Shin, Soon-Cheol
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1179-1182
    • /
    • 2005
  • Nowadays, CRTs are threatened by the flat panel displays (FPD). The screen quality of the CRT is one of best among the displays, however, the depth of CRTs becomes one of the most important design factor to maintain the dominated portion in the display market. When designing slim CRTs, the structure of the glass is important design factor because of the weight and safety. The stress in the glass is increased according to the shortening the total length of tube. The residual stress of the seal is also a major factor should be considered due to the large seal edge thickness. The glass design concept for Vixlim is introduced in this paper.

  • PDF

Fabrication and Characteristics of Electroluminescent Lamp (전계발광램프의 제작 및 특성)

  • 박욱동;최규만;최병진;김기완
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.5
    • /
    • pp.101-105
    • /
    • 1994
  • The EL lamp have been fabricated by screen printing method. the thickness of BaTiO$_3$ dielectric layer and ZnS:Cu phosphor layer was 20 $\mu$m and 40 $\mu$m, respectively. The threshold voltage of green El lamp was 50 $V_{p-p}$ and the maximum brightness was 13.5 $\mu$ W/cm$^2$ at frequency of 700 Hz and the input voltage of 250 $V_{p-p}$. Also when the Rodamin G6 of 0.02 g was doped, the threshold voltage of white EL lamp was 70 $V_{p-p}$ and the maximum brightness was 34 $\mu$W/cm$^2$.

  • PDF

A Study on the Two Phase Flow in the Floor of Containment Building after a Loss of Coolant Accident (냉각재 상실사고 후 격납건물내의 이상유동 연구)

  • Bae, Jin-Hyo;Park, Man Heung;Koh, Chul-Kyun;Lee, Jae-Heon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.10
    • /
    • pp.1274-1284
    • /
    • 1999
  • The Regulatory Guide 1.82 recommends an analysis of hydraulic performance for sump of ECCS (Emergency Core Cooing System) when LOCA(Loss of Coolant Accident) occurs in a nuclear power plant. The present study deals with 3-dimensional, unsteady, turbulent and two-phase flow simulation to examine the behavior of mixture of reactor coolant and debris near the floor of containment building in conjunction with appropriate assumptions. The dispersed solid model has been adjusted to the interfacial momentum transfer between reactor coolant and debris. According to the results, the counterclockwiserecirculation zone had been formed in the region between sump and connection aisle about 376 second after LOCA occurs. The debris thickness accumulated on a sump screen periodically increases or decreases up to 2000 second, afterwards its peak decreases.