• Title/Summary/Keyword: screen tests

Search Result 184, Processing Time 0.03 seconds

Evaluation of the Balance Ability for 20 to 29 Years Old on the Unstable Platform (불안정 발판(Unstable Platform)에서 20대 연령의 균형능력 평가)

  • Kwon, Oh-Yun;Choi, Houng-Sik
    • Physical Therapy Korea
    • /
    • v.3 no.3
    • /
    • pp.1-11
    • /
    • 1996
  • The purpose of this study were to evaluate and compare the balance ability at different conditions in normal 20 to 29 years old on unstable platform, KAT 2000(Breg, Inc., Vista, CA. 1994). Static and dynamic BI(balance index) were measured 3psi and 5psi surface conditions. Static tests were done on right and left leg separately, then both legs together with the feet apart 20cm with the eyes opened and closed. Dynamic tests were done on both legs together with apart 20cm with the eyes opened. A dynamic test was performed in which the subject moved platform in a circular manner to chase a moving object on a computer screen. Seventy healthy students(average 21.6 years, male, female) were tested. In this study applied the paired t-test and correlation to determine the statistical significance of result. The results were as follow: 1) The mean static balance index of the Rt leg was $119.9{\pm}75.72$ on 3psi surface condition with the eyes opened, and that of the Lt leg was $224.3{\pm}121.16$. 2) The mean static balance index of the Rt leg was $93.1{\pm}24.16$ on 5psi surface condition with the eyes opened, and that of the Lt leg was $180.5{\pm}61.76$. 3) The mean static and dynamic balance index of both legs were $76.4{\pm}31.86$, $2187.6{\pm}696.99$ on 3psi with the eyes opened, and $68.3{\pm}14.82$, $1938.7{\pm}525.41$ on 5psi respectively. 4) The mean static balance index of the Rt leg was $517.8{\pm}220.87$ on 3psi surface condition with the eyes closed, and that of the Lt leg was $588.6{\pm}204.81$. 5) The mean static balance index of the Rt leg was $271.9{\pm}192.151$ on 5psi surface condition with the eyes closed, and that of the Lt leg was $363.4{\pm}98.97$. 6) The mean static balance index of both legs was $332.6{\pm}137.31$ on 3psi surface condition with the eyes closed, and that of the 5psi was $288.5{\pm}133.07$. 7) The balance index on 3psi surface condition was significantly higher than that of 5psi (p<0.05, p<0.01). 8) The balance index with the eyes closed was significantly higher than that of the eyes opened (p<0.05). 9) The balance index on the left leg was significantly higher than that of the right leg (p<0.05, p<0.01). 10) There was no correlation between static balance index and dynamic balance index. 11) Therewas no correlation between weight or height and balance index.

  • PDF

A Family Screening of Patients with Vesicoureteral Reflux (방광 요관 역류 환아의 가족 선별 검사에 관한 연구)

  • Kang Hee;Kim Hyung Jin;Yoo Kee Hwan;Hong Young Sook;Lee Joo Won;Kim Soon Kyum
    • Childhood Kidney Diseases
    • /
    • v.5 no.1
    • /
    • pp.36-42
    • /
    • 2001
  • Purpose : Vesicoureteral reflux is the most commonly inherited disease detected in children with urinary tract infection. The incidence of vesicoureteral reflux among siblings of children with known vesicoureteral reflux is 8$\%$ to 45$\%$ according to different authors. Family screening of a patient with vesicoureteral reflux is important in order to prevent reflux nephropathy. The purpose of this study is to determine the incidence of vesicoureteral reflux in asymptomatic family of children with vesicoureteral reflux and the factors which influence the family history. Methods : The study group consisted of 27 families of patients with vesicoureteral reflux. The total number in the group were 79 persons. BUN, Cr, urineanalysis, voidingcystourethrography(VCUG) and 99mTc -dimercaptosuccinic acid(DMSA) renal scan were performed oil tile siblings. As for tile parents the same tests were performed except the VCUG. Results : The abnormality was detected in 7 of 27 families(25.9$\%$). Vesicoureteral reflux was detected in 5 of 20 siblings and renal scar ns detected in 3 of 32 parents. In children with vesicoureteral reflux, renal scar was detected in 24 of 32 children. Between the group with the abnormality in its family(Group A) and the group without the abnormality in its family(Group B), There was no difference of creatinine clearance between two groups. More renal scars were detected in group A according to the DMSA(A:100$\%$, B:75$\%$. t-test P<0.05). There was no difference of grade of VCUG between two groups. There was no difference between one site and both sites in two groups. In tile case of tile siblings with vesicoureteral reflux, there was high incidence of renal scar in a patient with vesicoureteral reflux according to the DMSA. Conclusion : It is important to screen vesicoureteral reflux and renal scar in case of urinary tract infection to prevent reflux nephropathy. This study implies that it is necessary to screen the family of a patient with vesicoureteral reflux especially with renal scar. (J, Korean Soc Pediatr Nephrol 5 : 36- 42, 2001)

  • PDF

Feasibility Study for the Cleaning of Well Screens using High-voltage Pulsed Discharge (고전압 펄스 방전을 이용한 지하수 관정 스크린 공막힘 재생법 연구)

  • Chung, Kyoung-Jae;Lee, Seok-Geun;Dang, Jeong-Jeung;Choi, Gil-Hwan;Hwang, Y.S.;Kim, Chul-Young;Park, Young-Jun
    • The Journal of Engineering Geology
    • /
    • v.23 no.1
    • /
    • pp.29-36
    • /
    • 2013
  • The application of appropriate rehabilitation methods can improve the efficiency of clogged wells and extend their life. In this paper, we study the feasibility of well cleaning using high-voltage pulsed discharge, in which electrical energy is used to produce impulsive pressure in water, in contrast to conventional methods that employ chemical or pneumatic energy sources. This technique utilizes the compressive shock wave generated by the expansive force of hot, dense plasma that is produced during a pulsed discharge in the gap between electrodes immersed in water. Compared with conventional techniques, this method is simple, and easy to handle and control. Using a capacitive pulsed power system with an electrical energy of 200 J, an impulsive pressure of 10.7 MPa is achieved at the position 6 cm away from the discharge gap. The amplitude of the impulsive pressure was easily controlled by adjusting the charging voltage of the capacitor and was almost linearly proportional to peak discharge current. The technique achieved good results in cleaning feasibility tests with mock-up specimens similar to clogged well screens.

Evaluation of Gestational Age Median Value by Use of the Quad Test with Dimeric Inhibin A for Korea Pregnant Women (Inhibin-A를 추가한 Quad Test의 한국인 산모의 임신주수별 Median치에 대한 평가)

  • Yoo, Ja-Young;Choi, Sam-Kyu;Cho, Young-Suk;Hwang, Do-Young
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.37 no.1
    • /
    • pp.56-60
    • /
    • 2005
  • Human chorionic gonadotrophin (hCG) and unconjugated estriol (uE3) were added to AFP to make what is commonly known as the Triple test. The Triple test combines results from these three tests and has been a standard screening procedure for several years. Recent studies have demonstrated the usefulness of adding inhibin-A to Down's syndrome risk assessment. The Quad test adds dimeric Inhibin-A (DIA) to the three other markers and uses the same computer program to calculate risk factors. Testing was performed between 14 and 21 weeks of gestation. Sample size were 648 samples and period of study was from 1, July, 2004 to 30, September, 2004. Used analytical methods for AFP, hCG and uE3 were radioimmunoassay (RIA) and dimeric inhibin A was enzyme-linked immunosorbent assay (ELISA). Adding dimeric inhibin-A as a fourth marker to the standard triple test increases the detection rate from 62 % to 75 % with a false-positive rate of 5%. The DIA based Quad test has been shown to be the most effective second trimester screening test for Down's syndrome suitable for routine use. Increased DIA values are observed during normal pregnancy where a bimodal pattern response is seen. Values increase during the first trimester, decline after 14 weeks, and re-ascend between 17-25 weeks. Values for DIA may be additionally elevated during a Down's syndrome pregnancy. Dimeric inhibin A is a glycoprotein hormone made by the ovary and placenta. DIA levels are twice as high in Down's syndrome pregnancies. AFP, hCG, and uE3 levels vary with gestational age, and incorrect gestational dating will influence results. DIA levels do not vary substantially with gestational age, resulting in greater screening accuracy. Although the Quad test is an improvement over the Triple test, it is important to underscore the fact that a positive test on both should be done. Most women who initially screen positive will be found to be carrying normal babies when amniocentesis and definitive diagnostic chromosome analysis are done.

  • PDF

Development on New Laser Tabbing Process for Modulation of Thin Solar Cell (박형 태양 전지 모듈화를 위한 레이져 태빙 자동화 공정(장비) 개발)

  • No, Donghun;Choi, Chul-June;Cho, Hyun Young;Yu, Jae Min;Kim, JungKeun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.58.1-58.1
    • /
    • 2010
  • In solar cell module manufacturing, single solar cells has to be joined electrically to strings. Copper stripes coated with tin-silver-copper alloy are joined on screen printed silver of solar cells which is called busbar. The bus bar collects the electrons generated in solar cell and it is connected to the next cell in the conventional module manufacturing by a metal stringer using conventional hot air or infrared lamp soldering systems. For thin solar cells, both soldering methods have disadvantages, which heats up the whole cell to high temperatures. Because of the different thermal expansion coefficient, mechanical stresses are induced in the solar cell. Recently, the trend of solar cell is toward thinner thickness below 180um and thus the risk of breakage of solar cells is increasing. This has led to the demand for new joining processes with high productivity and reduced error rates. In our project, we have developed a new method to solder solar cells with a laser heating source. The soldering process using diode laser with wavelength of 980nm was examined. The diode laser used has a maximum power of 60W and a scanner system is used to solder dimension of 6" solar cell and the beam travel speed is optimized. For clamping copper stripe to solar cell, zirconia(ZrO)coated iron pin-spring system is used to clamp both joining parts during a scanner system is traveled. The hot plate temperature that solar cell is positioned during lasersoldering process is optimized. Also, conventional solder joints after $180^{\circ}C$ peel tests are compared to the laser soldering methods. Microstructures in welded zone shows that the diffusion zone between solar cell and metal stripes is better formed than inIR soldering method. It is analyzed that the laser solder joints show no damages to the silicon wafer and no cracks beneath the contact. Peel strength between 4N and 5N are measured, with much shorter joining time than IR solder joints and it is shown that the use of laser soldering reduced the degree of bending of solar cell much less than IR soldering.

  • PDF

A Study on Product Design Process in Digital Environment A Comparative Analysis of Image Evaluation and Design Factors in Internet Environment and Reality Environment (디지털 환경 하에 제품디자인 프로세스 연구 -인터넷 환경과 현실 환경에서의 제품디자인 이미지 평가 및 디자인 요소 비교분석-)

  • 윤형건
    • Archives of design research
    • /
    • v.13 no.3
    • /
    • pp.123-134
    • /
    • 2000
  • Electronic commerce in digital environment is greatly different from the commerce in physical environment in the past (reality environment) in terms of marketing, distribution structure and, above an, comsumers'purchase pattern. The Old purchase pattern is that a consumer buys a product after s/he touches, tests, and feels it physically, while the purchase pattern in electronic commerce enables the comsumer to make a decision about whether to buy it or not through the information gleaned from the computer monitor screen. A number of products which appears in the market now are designed to use the reality environment setup without consideration of the digital environment, of which the intention is to appeal to consumers with a series of design process. However, taking under consideration the present situation in which lots of electronic commerce are made in the cyber space or digital environment, we are required to forward the product design which can gains the positive attraction for consumers in this environment. Factor analysis is made in order to understand how the subjects perceive the image of the design of the product both in reality situation and in digital environment. The result shows the first factor has different images in those environments. In the background of this conclusion rests the fact that the difference of the transfer of formative factors to consumers is made in the images which show themselves in those different environments.

  • PDF

Abnormal Changes in Groundwater Monitoring Data Due to Small-Magnitude Earthquakes (지하수 모니터링 이상변동 자료를 이용한 소규모 지진 영향 유추)

  • Woo, Nam C.;Piao, Jize;Lee, Jae-Min;Lee, Chan-Jin;Kang, In-Oak;Choi, Doo-Houng
    • The Journal of Engineering Geology
    • /
    • v.25 no.1
    • /
    • pp.21-33
    • /
    • 2015
  • This study tests the potential of detecting small-magnitude earthquakes (~M3.0) and their precursors using a long-term groundwater-monitoring database. In groundwater records from April to June 2012, abnormal changes in water level, temperature, and electrical conductivity were identified in the bedrock monitoring wells of the Gimcheon-Jijwa, Gangjin-Seongjeon, and Gongju-Jeongan stations. These anomalies could be attributed to the M3.1 earthquake that occurred in the Youngdeok area on May 30th, although no linear relationship was found between the scale of changes and the distance between each monitoring station and the epicenter, which is attributed in part to the wide screen design of the monitoring wells. Groundwater monitoring networks designed specifically for monitoring earthquake impacts could provide better information on the safety of underground space and on the security of emergency water-resources in earthquake disaster areas.

Design of Integrated Management System for Electronic Library Based on SaaS and Web Standard

  • Lee, Jong-Hoon;Min, Byung-Won;Oh, Yong-Sun
    • International Journal of Contents
    • /
    • v.11 no.1
    • /
    • pp.41-51
    • /
    • 2015
  • Management systems for electronic library have been developed on the basis of Client/Server or ASP framework in domestic market for a long time. Therefore, both service provider and user suffer from their high cost and effort in management, maintenance, and repairing of software as well as hardware. Recently in addition, mobile devices like smartphone and tablet PC are frequently used as terminal devices to access computers through the Internet or other networks, sophisticatedly customized or personalized interface for n-screen service became more important issue these days. In this paper, we propose a new scheme of integrated management system for electronic library based on SaaS and Web Standard. We design and implement the proposed scheme applying Electronic Cabinet Guidelines for Web Standard and Universal Code System. Hosted application management style and software on demand style service models based on SaaS are basically applied to develop the management system. Moreover, a newly improved concept of duplication check algorithm in a hierarchical evaluation process is presented and a personalized interface based on web standard is applied to implement the system. Algorithms of duplication check for journal, volume/number, and paper are hierarchically presented with their logic flows. Total framework of our development obeys the standard feature of Electronic Cabinet Guidelines offered by Korea government so that we can accomplish standard of application software, quality improvement of total software, and reusability extension. Scope of our development includes core services of library automation system such as acquisition, list-up, loan-and-return, and their related services. We focus on interoperation compatibility between elementary sub-systems throughout complex network and structural features. Reanalyzing and standardizing each part of the system under the concept on the cloud of service, we construct an integrated development environment for generating, test, operation, and maintenance. Finally, performance analyses are performed about resource usability of server, memory amount used, and response time of server etc. As a result of measurements fulfilled over 5 times at different test points and using different data, the average response time is about 62.9 seconds for 100 clients, which takes about 0.629 seconds per client on the average. We can expect this result makes it possible to operate the system in real-time level proof. Resource usability and memory occupation are also good and moderate comparing to the conventional systems. As total verification tests, we present a simple proof to obey Electronic Cabinet Guidelines and a record of TTA authentication test for topics about SaaS maturity, performance, and application program features.

Seven-year experience with inherited metabolic disorders screening by tandem mass spectrometry (Tandem Mass Spectrometry를 이용한 선천성 대사이상질환 선별검사 7년간의 경험)

  • Song, Sean-Mi;Yoon, Hye-Ran;Lee, An-Na;Lee, Kyoung-Ryul
    • Journal of Genetic Medicine
    • /
    • v.5 no.1
    • /
    • pp.21-25
    • /
    • 2008
  • Purpose : In recent years, many countries have adopted newborn screening programs that use tandem mass spectrometry (MS/MS) to screen and the number of diseases screened has also increased. We began screening for inherited metabolic disorders using MS/MS in April, 2001. Our goal was to determine the overall prevalence of metabolic disorders and to assess the effectiveness of newborn screening by MS/MS in Korea. Methods : From April, 2001 to December, 2007, we screened newborns and high risk groups using MS/MS. Acylcarnitines and amino acids were extracted and butylated and were introduced into the inlet of MS/MS. Confirmatory testing including a repeat newborn screening, and urine organic acid and plasma amino acid analysis were performed on a case-by-case basis. Results : The total number of screened subjects 284,933 which comprised 251,799 neonates and 33,134 high risk subjects. The recall rate was 0.4% (1158 tests) and true positive cases were 117 (0.04%). Confirmed metabolic disorders (newborn/high risk group) were as follows; 78 (25/53) amino acid disorders, 27 (16/11) organic acid disorders, and 12 (5/7) fatty acid oxidation disorders. The estimated prevalence of inherited metabolic diseases in newborns was 1:5,000 and that in the total group was 1:2,000. Conclusion : Newborn screening by MS/MS improved the detection of many inherited metabolic disorders. We therefore propose that all newborns be screened by a MS/MS national program and followed-up using a systemic organization strategy.

  • PDF

Knowledge, Attitudes and Behavior of Bangkok Metropolitan Women Regarding Cervical Cancer Screening

  • Chaowawanit, Woraphot;Tangjitgamol, Siriwan;Kantathavorn, Nuttavut;Phoolcharoen, Natacha;Kittisiam, Thannaporn;Khunnarong, Jakkapan;Supawattanabodee, Busaba;Srijaipracharoen, Sunamchok;Thavaramara, Thaovalai;Pataradool, Kamol
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.3
    • /
    • pp.945-952
    • /
    • 2016
  • Purpose: To assess knowledge, attitudes and cervical cancer screening behavior of Bangkok Metropolitan women. Materials and Methods: Thai women, aged 25-to-65 years old, having lived in Bangkok for 5 years or more were invited to participate in the study. After signing informed consent, all women were asked to complete a self-questionnaire (Thai language) with literate assistance if needed. The questionnaire was divided into 3 parts: (I) demographic data; (II) knowledge about cervical cancer screening; and (III) behavior and attitudes, towards cervical cancer screening. Adequate screening was defined as women who had ${\geq}$two cervical cancer screening tests except women aged 25-30 years who may have only one screening, and the last screen was within 5 year or had had regular screening. Results: Of 4,339 women, there were 1,857 (42.8%) with adequate screening and 2,482 (57.2%) with inadequate screening. Significant factors associated with inadequate screening included age < 45 years, pre-menopausal status, family monthly income <625 USD, no reported sexual intercourse, nulliparous, no knowledge, lack of awareness and poor attitudes. Three major reasons provided by women for inadequate screening were no symptoms (54.4%), fear of pain (33.2%), and embarrassment (34.6%). Conclusions: Personal features, knowledge, and attitudes influence screening behavior of Bangkok Metropolitan women. The three most common reasons of women for not undergoinging screening are no symptoms, fear of pain, and embarrassment. These factors should be the focus of attention to improve coverage of cervical cancer screening in Bangkok.