ATO 처리후, 플라즈마 전해 산화 처리된 Ti-6Al-4V 합금의 표면 형태 (Surface Morphology of PEO-treated Ti-6Al-4V Alloy after Anodic Titanium Oxide Treatment)

  • Kim, Seung-Pyo;Choe, Han-Cheol
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2018년도 춘계학술대회 논문집
    • /
    • pp.75-75
    • /
    • 2018
  • Commercially pure titanium (CP-Ti) and Ti-6Al-4V alloys have been widely used in implant materials such as dental and orthopedic implants due to their corrosion resistance, biocompatibility, and good mechanical properties. However, surface modification of titanium and titanium alloys is necessary to improve osseointegration between implant surface and bone. Especially, when titanium oxide nanotubes are formed on the surface of titanium alloy, cell adhesion is greatly improved. In addition, plasma electrolytic oxide (PEO) coatings have a good safety for osseointegration and can easily and quickly form coatings of uniform thickness with various pore sizes. Recently, the effects of bone element such as magnesium, zinc, strontium, silicon, and manganese for bone regeneration are researching in dental implant field. The purpose of this study was researched on the surface morphology of PEO-treated Ti-6Al-4V alloy after anodic titanium oxide treatmentusing various instruments. Ti-6Al-4V ELI disks were used as specimens for nanotube formation and PEO-treatment. The solution for the nanotube formation experiment was 1 M $H_3PO_4$ + 0.8 wt. % NaF electrolyte was used. The applied potential was 30V for 1 hours. The PEO treatment was performed after removing the nanotubes by ultrasonics for 10 minutes. The PEO treatment after removal of the nanotubes was carried out in the $Ca(CH_3)_2{\cdot}H_2O+(CH_3COO)_2Mg{\cdot}4H_2O+Mn(CH_3COO)_2{\cdot}4H_2O+Zn(CH_3CO_2)_2Zn{\cdot}2H_2O+Sr(CH_2COO)_2{\cdot}0.5H_2O+C_3H_7CaO_6P$ and $Na_2SiO_3{\cdot}9H_2O$ electrolytes. And the PEO-treatment time and potential were 3 minutes at 280V. The morphology changes of the coatings on Ti-6Al-4V alloy surface were observed using FE-SEM, EDS, XRD, AFM, and scratch tester. The morphology of PEO-treated surface in 5 ion coating solution after nanotube removal showed formation or nano-sized mesh and micro-sized pores.

  • PDF

지대주의 반복적인 착탈에 따른 임플랜트 고정체의 external hexagon과 지대주 internal hexagon의 변화에 관한 연구 (SURFACE CHANCE OF EXTERNAL HEXAGON OF IMPLANT FIXTURE AND INTERNAL HEXAGON OF ABUTMENT AFTER REPEATED DELIVERY AND REMOVAL OF ABUTMENT)

  • 정석원;김희중;정재헌
    • 대한치과보철학회지
    • /
    • 제43권4호
    • /
    • pp.528-543
    • /
    • 2005
  • Statement of problem: Repeated delivery and removal of abutment cause some changes such as wear, scratch or defect of hexagonal structure. It may increase the value of rotational freedom(RF) between hexagonal structures. Purpose: The purpose of this study was to evaluate surface changes and rotational freedom between the external hexagon of the implant fixture and internal hexagon of abutment after repeated delivery and removal under SEM and toolmaker's microscope. Materials and methods: Implant systems used for this study were 3i and Avana. Seven pail's of implant fixture, abutment and abutment screws for each system were selected and all fixtures were perpendicularly mounted in liquid unsaturated polyesther with dental surveyor. Each one was embedded beneath the platform of fixture. Surfaces of hexagonal structure before repeated closing and opening of abutment were observed using SEM and rotational freedom was measured by using toolmaker's microscope. Each abutment was secured to the implant future by each abutment screw with recommended torque value using a digital torque controller and was repeatedly delivered and removed by 20 times respectively. After experiment, evaluation for the change of hexagonal structures and measurement of rotational freedom were performed. Result : The results were as follows; 1. Wear of contact area between implant fixture and abutment was considerable in both 3i and Avana system. Scratches and defects were frequently observed at the line-angle of hexagonal structures of implant fixture and abutment. 2. In the SEM view of the external hexagon of implant fixture, the point-angle areas at the corner edge of hexagon were severely worn out in both systems. It was more notable in the case of 3i systems than in that of Avana systems. 3. In the SEM view of the internal hexagon of abutment, Gingi-Hue abutment of 3i systems showed severe wear in micro-stop contacts that were machined into the corners to prevent rotation and cemented abutment of Avana systems showed wear in both surface area adjacent to the corner mating with external hexagon of implant fixture. 4 The mean values of rotational freedom between the external hexagon of the implant fixture and internal hexagon of abutment were 0.48$\pm$0.04$^{\circ}$ in pre-tested 3i systems and 1.18$\pm$0.25$^{\circ}$ after test, and 1.80$\pm$0.04$^{\circ}$ in pre-tested Avana systems and 2.61$\pm$0.16$^{\circ}$ after test. 5. Changes of rotational freedom after test shouted statistical)y a significant increase in both 3i and Avana systems(P<0.05, paired t-test). 6. Statistically, there was no significant difference between amount of increase in the rotational freedom of 3i systems and amount of increase in that of Avana ones(P>0.05, unpaired t-test). Conclusion: Conclusively, it was considered that repeated delivery and remove of abutment by 20 times would not have influence on screw joint stability. However, it caused statistically the significant change of rotational freedom in tested systems. Therefore, it is suggested that repeated delivery and remove of abutment should be minimal as possible as it could be and be done carefully Additionally, it is suggested that the means or treatment to prevent the wear of mating components should be devised.

텅스텐 화학적-기계적 연마 공정에서 부식방지막이 증착된 금속 컨디셔너 표면의 전기화학적 특성평가 (Electrochemical Characterization of Anti-Corrosion Film Coated Metal Conditioner Surfaces for Tungsten CMP Applications)

  • 조병준;권태영;김혁민;;박문석;박진구
    • 마이크로전자및패키징학회지
    • /
    • 제19권1호
    • /
    • pp.61-66
    • /
    • 2012
  • 반도체 산업에서 회로의 고집적화와 다층구조를 형성하기 위해 화학적-기계적 연마(CMP: Chemical-Mechanical Planarization) 공정이 도입되었으며 반도체 패턴의 미세화와 다층화에 따라 화학적-기계적 연마 공정의 중요성은 더욱 강조되고 있다. 화학적-기계적 연마공정이란 화학적 반응과 기계적 힘을 동시에 이용하여 표면을 평탄화하는 공정으로, 화학적-기계적 연마 공정은 압력, 속도 등의 공정조건과, 화학적 반응을 유도하는 슬러리(Slurry), 기계적 힘을 위한 패드 등에 의해 복합적으로 영향을 받는다. 패드 컨디셔닝이란 컨디셔너가 화학적-기계적 연마 공정 중에 지속적으로 패드 표면을 연마하여 패드의 손상된 부분을 제거하고 새로운 표면을 노출시켜 패드의 상태를 일정하게 유지시키는 것을 말한다. 한편, 금속박막의 화학적-기계적 연마 공정에 사용되는 슬러리는 금속박막과 산화반응을 하기 위하여 산화제를 포함하는데, 산화제는 금속 컨디셔너 표면을 산화시켜 부식을 야기한다. 컨디셔너의 표면부식은 반도체 수율에 직접적인 영향을 줄 수 있는 스크래치(Scratch) 등을 발생시킬 뿐만 아니라, 컨디셔너의 수명도 저하시키게 되므로 이를 방지하기 위한 노력이 매우 중요하다. 본 연구에서는 컨디셔너 표면에 슬러리와 컨디셔너 표면 간에 일어나는 표면부식을 방지하기 위하여 유기박막을 표면에 증착하여 부식을 방지하고자 하였다. 컨디셔너 제작에 사용되는 금속인 니켈과 니켈 합금을 기판으로 하고, 증착된 유기박막으로는 자기조립단분자막(SAM: Self-Assembled Monolayer)과 불화탄소(FC: FluoroCarbon) 박막을 증착하였다. 자기조립단분자막은 2가지 전구체(Perfluoroctyltrichloro silane(FOTS), Dodecanethiol(DT))를 사용하여 기상 자기조립 단분자막 증착(Vapor SAM) 방법으로 증착하였고, 불화탄소막은 10 nm, 50 nm, 100 nm 두께로 PE-CVD(Plasma Enhanced-Chemical Vapor Deposition, SRN-504, Sorona, Korea) 방법으로 증착하여 표면의 부식특성을 평가하였다. 표면 부식 특성은 동전위분극법(Potentiodynamic Polarization)과 전기화학적 임피던스 측정법(Electrochemical Impedance Spectroscopy(EIS)) 등의 전기화학 분석법을 사용하여 평가되었다. 또한 측정된 임피던스 데이터를 전기적 등가회로(Electrical Equivalent Circuit) 모델에 적용하여 부식 방지 효율을 계산하였다. 동전위분극법과 EIS의 결과 분석으로부터 유기박막이 증착된 표면의 부식전류밀도가 감소하고, 임피던스가 증가하는 것을 확인하였다.