• Title/Summary/Keyword: scanning measurements

Search Result 741, Processing Time 0.026 seconds

Estimation of fresh weight for chinese cabbage using the Kinect sensor (키넥트를 이용한 배추 생체중 추정)

  • Lee, Sukin;Kim, Kwang Soo
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.20 no.2
    • /
    • pp.205-213
    • /
    • 2018
  • Development and validation of crop models often require measurements of biomass for the crop of interest. Considerable efforts would be needed to obtain a reasonable amount of biomass data because the destructive sampling of a given crop is usually used. The Kinect sensor, which has a combination of image and depth sensors, can be used for estimating crop biomass without using destructive sampling approach. This approach could provide more data sets for model development and validation. The objective of this study was to examine the applicability of the Kinect sensor for estimation of chinese cabbage fresh weight. The fresh weight of five chinese cabbage was measured and compared with estimates using the Kinect sensor. The estimates were obtained by scanning individual chinese cabbage to create point cloud, removing noise, and building a three dimensional model with a set of free software. It was found that the 3D model created using the Kinect sensor explained about 98.7% of variation in fresh weight of chinese cabbage. Furthermore, the correlation coefficient between estimates and measurements were highly significant, which suggested that the Kinect sensor would be applicable to estimation of fresh weight for chinese cabbage. Our results demonstrated that a depth sensor allows for a non-destructive sampling approach, which enables to collect observation data for crop fresh weight over time. This would help development and validation of a crop model using a large number of reliable data sets, which merits further studies on application of various depth sensors to crop dry weight measurements.

Quantitative Evaluation of the Accuracy of 3D Imaging with Multi-Detector Computed Tomography Using Human Skull Phantom (두개골 팬텀을 이용한 다검출기 CT 3차원 영상에서의 거리측정을 통한 정량적 영상특성 평가)

  • 김동욱;정해조;김새롬;유영일;김기덕;김희중
    • Progress in Medical Physics
    • /
    • v.14 no.2
    • /
    • pp.131-140
    • /
    • 2003
  • As the importance of accuracy in measurings of 3-D anatomical structures continues to be stressed, an objective and quantitative of assessing image quality and accuracy of 3-D volume-rendered images is required. The purpose of this study was to evaluate the quantitative accuracy of 3-D rendered images obtained with MDCT, scanned at various scanning parameters (scan modes, slice thicknesses and reconstruction slice thickness). Twelve clinically significant points that play an important role for the craniofacial bone in plastic surgery and dentistry were marked on the surface of a dry human skull. The direct distances between the reference points were defined as gold standards to assess the measuring errors of 3-D images. Then, we scanned the specimen with acquisition parameters of 300 mA, In kVp, and 1.0 sec scan time in axial and helical scan modes (pitch 3:1 and 6:1) at 1,25 mm, 2.50 mm, 3.75 mm and 5.00 mm slice thicknesses. We performed 3-D visualizations and distance measurements with volumetric analysis software and statistically evaluated the quantitative accuracy of distance measurements. The accuracy of distance measurements on the 3-D images acquired with 1.25, 2.50, 3,75 and 5.00 mm slice thickness were 48%, 33%, 23%, 14%, respectively, and those of the reconstructed 1.25 mm were 53%, 41%, 43%, 36% respectively. Meanwhile, there were insignificant statistical differences (P-value<0.05) in the accuracy of the distance measurements of 3-D images reconstructed with 1.25 mm thickness. In conclusion, slice thickness, rather than scan mode, influenced the quantitative accuracy of distance measurements in 3-D rendered images with MDCT. The quantitative analysis of distance measurements may be a useful tool for evaluating the accuracy of 3-D rendered images used in diagnosis, surgical planning, and radiotherapeutic treatment.

  • PDF

A study on enamel thickness of maxillary incisors using X-ray micro computed tomography (MicroCT를 이용한 상악 전치의 법랑질 두께에 관한 연구)

  • Cho, Young-Won;Cho, Jin-Hyun;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.4
    • /
    • pp.301-307
    • /
    • 2010
  • Purpose: The objectives of the current study are to assess the accuracy of X-Ray Micro Computed Tomography (microCT) in measuring enamel thickness and to evaluate enamel thickness in maxillary incisors of Koreans. Materials and methods: Five maxillary incisors were embedded in resin block. These teeth were longitudinally sectioned labiolingually through the medial axis. After polishing, the teeth were scanned using a microCT (X-EYE SYSTEM; DRGEM, Seoul, Korea). On a scanning electron microscope (S-4300; Hitachi, Tokyo, Japan) (${\times}20$) and a microCT, nearly identical planes were reconstructed. In each tooth, the thickness of labial enamel was measured 1, 3 and 5 mm above the cementoenamel junction (CEJ). Thus, the accuracy of the microCT was evaluated. In addition, using 26 maxillary central incisors and 11 maxillary lateral incisors, in the medial axis and 2 mm remote areas mesially and distally from the medial axis, the thickness of labial enamel was measured 1, 3 and 5 mm above the CEJ along the long axis of the teeth. Results: Measurements from nearly identical planes in physical and microCT sections differed by 3.81%. An independent t-test was performed and this showed that there were no significant differences in the measurements between the two methods. Mean values of labial enamel thickness in maxillary central incisors 1, 3 and 5 mm above the CEJ were $0.32{\pm}0.01$, $0.50{\pm}0.0.2$ and $0.70{\pm}0.02\;mm$, respectively. Mean values of labial enamel thickness in maxillary lateral incisors 1, 3 and 5 mm above the CEJ were $0.30{\pm}0.01$, $0.55{\pm}0.03$ and $0.80{\pm}0.02\;mm$, respectively. Conclusion: In measuring enamel thickness, microCT is one of useful way of measurement. So according to the results of this research, when restoring a porcelain laminate veneer on maxillary incisors in Koreans, careful consideration is needed in the amount of enamel reduction.

Characteristics of c-axis oriented sol-gel derived ZnO films (C-축으로 정렬된 sol-gel ZnO 박막의 특성)

  • 김상수;장기완;김인성;송호준;박일우;이건환;권식철
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.11 no.2
    • /
    • pp.49-55
    • /
    • 2001
  • ZnO films were fabricated on p-type Si(100) wafer ITO glass and quartz glass by the sol-gel process using zinc acetate dihydrate as starting material. A homogeneous and stable solution was prepared by dissolving the zinc acetate dihydrate in a solution of 2-methoxyethanol and monoethanolamine (MEA). ZnO films were deposited by spin-coating at 2800 rpm for 25 s and were dried on a hot plate at $250^{\circ}C$ for 10 min. Crystallization of the films was carried out at $400^{\circ}C$~$800^{\circ}C$ for 1 h in air. X-ray diffraction (XRD) analysis, scanning electron microscopy (SEM), UV-vis transmittance spectroscopy, FTIR transmittance spectroscopy and Photoluminescence (PL) spectroscopy measurements have been used to study the structural and optical properties of the films. ZnO films highly oriented along the (002)plane were obtained. In all cases the films were found to be transparent (above 70%) in visible range with a sharp absorption edge at wavelengths of about 380nm, which is very close to the intrinsic band-gap of ZnO(3.2 eV). The low temperature band-edge photoluminescence revealed a complicated multi-line structure in terms of bound exciton complexes and the phonon replicas.

  • PDF

A STUDY ON GEOMETRIC COMPARISON OF FOUR INTERCHANGEABLE IMPLANT PROSTHETIC RETAINING SCREWS AND MEASUREMENT OF LOOSENING TORGUE (호환 가능한 임플랜트 보철용 유지 나사들의 형태 비교와 풀림 회전력의 측정에 관한 연구)

  • Cho, Su-Mi;Lim, Ju-Hwan;Cho, In-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.3
    • /
    • pp.468-482
    • /
    • 1998
  • Since the concept of osseointegration was introduced by Branemark of Sweden, dental implants have been used for various dental prosthetic treatments. The survival rate of dental implant is likely to be closely related to the total biomechanical role of each component of implant system. The use of interchangeable component is very attractive for dental practitioners because such an approach would save treatment cost, flexibility of prosthetic treatment options as well as conveniences. Therefore, the use of interchangeable implant system has been increasing without scientific assessment of safety and efficacy of various interchangeable implant system. The purpose of this study, therefore, were to compare the geometric characteristic of four interchangeable dental implant screws and the loosening torque of these screws. Four types of dental implant screws tested in this study were Nobelpharma, 3i, Impla-med, Restore. Four screws each of the test specimens were subjected for scanning electron microscopic examinations under the same condition and a 35x magnified standard SEM picture was objected from each test specimen using JSM-5200 scanning microscope. From each of the SEM pictures, eight parameters. i.e., diameter of screw head. screw length, thread pitch, major diameter. neck diameter, neck length, crest width and root width were determined using a caliper. The measurement for each parameters were then corrected for their magnification factor. The loosening torque were also determined by using a torque gauge. All of the measurements were statistically analyzed by ANOVA test and multiple range test. Statistical significance was set in advance at the probability level of less than 0.05. All analyses were done with SPSS software for the personal computer. The conclusion obtained from this studies were summarized as the following; 1. No statistically significances were noted in the thread pitch. and crest width in the four screws, and in the case of major diameter, the Impla-med screw was significantly smaller than the other three screws (p<0.05). Therefore, four implant bolts could be physically inserted in a abutment nuts. 2. The diameter of screw head was decreased in the order of Restore, 3i, Nobelpharma, Impla-med screws and the length of screws were decreased in the order of 3i, Restore, Nobelpharma and Impla-med. The diameter of neck was decreased in the order of Impla-med, Restore. Nobelpharma, 3i screws. The differences of each of these parameters were statistically significant (p<0.05). The width of root of screws were decreased in the order of Nobelpharma, Impla-med, Restore and 3i. The differences among Nobelpharma and Impla-med. Restore and 3i were statistically significant (p<0.05). 3. When the screws were loosening 1, 3, 4 and 5 times, the loosening torque for Impla-med and 3i screws were significantly higher than that of Nobelpharma or Restore screws (p<0.05). However, when statistically smaller than that of 3i, Restore or Nobelpharma screws(p<0.05).

  • PDF

Microstructures and Electrochemical Properties of Si-M (M : Cr, Ni) as Alloy Anode for Li Secondary Batteries (리튬이차전지용 Si-M (M : Cr, Ni) 합금 음극의 미세구조와 전기화학적 특성)

  • Lee, Sung-Hyun;Sung, Jewook;Kim, Sung-Soo
    • Journal of the Korean Electrochemical Society
    • /
    • v.18 no.2
    • /
    • pp.68-74
    • /
    • 2015
  • To compare the microstructure and electrochemical properties between two binary alloys (Cr-Si, Ni-Si), two composition of binary alloys with the same capacity were selected using phase-diagram and prepared by matrix-stabilization method to suppress the volume expansion of Si by inactive-matrix. Master alloys were made by Arc-melting followed by fine structured ribbon sample preparation by Rapid Solidification Process (RSP, Melt-spinning method) under the same conditions. Also powder samples were produced by wet grinding for X-Ray Diffraction (XRD) and electrochemical measurements. As predicted from the phase diagram, only active-Si and inactive-matrix ($CrSi_2$, $NiSi_2$) were detected. The results of Scanning Electron Microscope (SEM) and Transmission Electron Microscopy - Energy Dispersive X-ray Spectroscopy (TEM-EDS) show that Cr-Si alloy has finer microstructure than Ni-Si alloy, which was also predictable through phase diagram. The electrochemical properties related to microstructure were evaluated by coin type full- and half-cells. Separately, self-designed test-cells were used to measure the volume expansion of Si during reaction. Volume expansion of Cr-Si alloy electrode with finer microstructure was suppressed significantly and improved in cycle capability, in comparison Ni-Si alloy with coarse microstructure. From these, we could infer the correlation of microstructure, volume expansion and electrochemical degradation and these properties might be predicted by phase diagram.

Accuracy of Ultrasonography in Early Pregnancy Diagnosis in Doe

  • Singh, N.S.;Gawande, P.G.;Mishra, O.P.;Nema, R.K.;Mishra, U.K.;Singh, Mohan
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.17 no.6
    • /
    • pp.760-768
    • /
    • 2004
  • The present study was undertaken to evaluate the accuracy of ultrasonography in early pregnancy diagnosis in goats. Ultrasonographic scanning with real time B-mode ultrasound machine having 5 MHz linear array transducer was performed on gravid uterus (n=24) obtained from slaughterhouse (Group I). Crown rump length (CRL) measured by ultrasound was found significantly different (p<0.05) with actual CRL measured after dissection in early pregnancy. However, age predicted by ultrasound through the measurement of CRL was found highly correlated (r=0.92) with age measured after dissection through CRL and the weight of fetus. Ages predicted by ultrasound through the measurement of trunk diameter (TD) and uterine diameter (UD) and ages measured after dissection were found highly and equally correlated (r=0.98) and did not differ significantly. Data from six does synchronized (Group II) with PGF2$\alpha$ (Estrumate) at 11 days apart were collected through ultrasound from 17 to 42 days post breding. The correlation between CRL and gestational age was high (r=0.97) in day 30 to 42 post breeding. A high coefficient of correlation (r=0.98) was also observed between predicated age by ultrasound and actual age calculated after kidding. The correlation between CRL and gestational age by the formula Y=(a+bX) i.e. Y=24.42+0.39 X where Y=gestational age and X=CRL, was recorded very high (r=0.99). Accuracy of ultrasonography was lowest on day 17 to 19 (66%) and reached 100% on day 34. Data from 30 does (group III) randomly subjected to only one time ultrasounds scanning to assess the accuracy of pregnancy diagnosis were also obtained. Ages predicted by TD and UD measurements were observed to be non-significantly different with actual age obtained after kidding and correlation between ages predicted by TD and UD measurement with actual age after kidding was found equally and highly correlated (r=0.98). The operator's accuracy in the whole experiment including all three groups was found to be 92%. The sensitivity was 93% and specificity was 86%. From the present study, it was observed that CRL was the most reliable parameter to find out gestational age in early pregnancy and the new formula derived was found very accurate to find out gestational age. TD and UD were also found to be equally reliable parameter to find out gestational age in mid and late stage of pregnancy through ultrasonography. It was concluded that ultrasonography by real time B mode with 5 MHz transrectal transducer was found to be reliable, safe and accurate and practicable means in diagnosing early pregnancy diagnosis as early as 25 days post breeding.

Optical Properties and Structural Analysis of SiO2 Thick Films Deposited by Plasma Enhanced Chemical Vapor Deposition (PECVD법에 의해 증착된 SiO2 후막의 광학적 성질 및 구조적 분석)

  • Cho, Sung-Min;Kim, Yong-Tak;Seo, Yong-Gon;Yoon, Hyung-Do;Im, Young-Min;Yoon, Dae-Ho
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.5
    • /
    • pp.479-483
    • /
    • 2002
  • Silicon dioxide thick film using silica optical waveguide cladding was fabricated by Plasma Enhanced Chemical Vapor Deposition(PECVD) method, at a low temperature ($320^{\circ}$C) and from $(SiH_4+N_2O)$ gas mixtures. The effects of deposition parameters on properties of $SiO_2$ thick films were investigated by variation of $N_2O/SiH_4$ flow ratio and RF power. After the deposition process, the samples were annealed in a furnace at $1150^{\circ}$C, in N2 atmosphere, for 2h. As the $N_2O/SiH_4$ flow ratio increased, deposition rate decreased from 9.4 to 2.9 ${\mu}m/h$. As the RF power increased, deposition rate increased from 4.7 to 6.9 ${\mu}m/h$. The thickness and the refractive index measurements were measured by prism coupler. X-ray Photoelectron Spectroscopy(XPS) and Fourier Transform-infrared Spectroscopy(FT-IR) were used to determine the chemical states. The cross-section of films was observed by Scanning Electron Microscopy(SEM).

Study on the Calibration of a Full-Polarimetric Scatterometer System at X-band (X-밴드 완전 편파 Scatterometer 시스템 보정에 관한 연구)

  • Hwang, Ji-Hwan;Park, Seong-Min;Kwon, Soon-Gu;Oh, Yi-Sok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.4
    • /
    • pp.408-416
    • /
    • 2010
  • A study on the calibration of an X-band HPS(Hongik Polarimetric Scatterometer) system for ground-based operation is presented in this paper. In order to calibrate the scatterometer system, the degree of its distortions are analyzed by comparison between theoretical- and measured-values using the theoretically well-known calibration targets such as a metal sphere, a trihedral corner reflector(CR) and a metal cylinder. The calibration works in the field conditions depend on the precise and stable measurements of those calibration target. we present a measurement technique, so-called, an automatic 2-D target-scanning technique, using the incidence-angle(${\xi}-$ and ${\phi}-$ directions) control of HPS system. Then, we used STCT(Single-Target Calibration Technique) and GCT(General Calibration Technique) to calibrate a distortion of the scatterometer system, and measured the polarimetric RCS(Radar Cross Section) and phase-difference of a trihedral-CR as a test-target to verify the accuracy of the calibration technique. Then, three different types(i.e., 10, 20, 30 cm) of trihedral-CR were used. we obtained the error ranges about ${\pm}1.0$dB, ${\pm}0.5$ dB in a polarimetric RCS and about $-20^{\circ}{\sim}0^{\circ}$ and ${\pm}5^{\circ}$ in the co-polarized phase-difference by using the GCT and STCT, respectively.

Biocompatibility study of lithium disilicate and zirconium oxide ceramics for esthetic dental abutments

  • Brunot-Gohin, Celine;Duval, Jean-Luc;Verbeke, Sandra;Belanger, Kayla;Pezron, Isabelle;Kugel, Gerard;Laurent-Maquin, Dominique;Gangloff, Sophie;Egles, Christophe
    • Journal of Periodontal and Implant Science
    • /
    • v.46 no.6
    • /
    • pp.362-371
    • /
    • 2016
  • Purpose: The increasing demand for esthetically pleasing results has contributed to the use of ceramics for dental implant abutments. The aim of this study was to compare the biological response of epithelial tissue cultivated on lithium disilicate ($LS_2$) and zirconium oxide ($ZrO_2$) ceramics. Understanding the relevant physicochemical and mechanical properties of these ceramics will help identify the optimal material for facilitating gingival wound closure. Methods: Both biomaterials were prepared with 2 different surface treatments: raw and polished. Their physicochemical characteristics were analyzed by contact angle measurements, scanning white-light interferometry, and scanning electron microscopy. An organotypic culture was then performed using a chicken epithelium model to simulate peri-implant soft tissue. We measured the contact angle, hydrophobicity, and roughness of the materials as well as the tissue behavior at their surfaces (cell migration and cell adhesion). Results: The best cell migration was observed on $ZrO_2$ ceramic. Cell adhesion was also drastically lower on the polished $ZrO_2$ ceramic than on both the raw and polished $LS_2$. Evaluating various surface topographies of $LS_2$ showed that increasing surface roughness improved cell adhesion, leading to an increase of up to 13%. Conclusions: Our results demonstrate that a biomaterial, here $LS_2$, can be modified using simple surface changes in order to finely modulate soft tissue adhesion. Strong adhesion at the abutment associated with weak migration assists in gingival wound healing. On the same material, polishing can reduce cell adhesion without drastically modifying cell migration. A comparison of $LS_2$ and $ZrO_2$ ceramic showed that $LS_2$ was more conducive to creating varying tissue reactions. Our results can help dental surgeons to choose, especially for esthetic implant abutments, the most appropriate biomaterial as well as the most appropriate surface treatment to use in accordance with specific clinical dental applications.