• Title/Summary/Keyword: scan pattern

Search Result 397, Processing Time 0.029 seconds

Development of a Semi-Atomatic Protocol for embodiment of a desirable 3D breast shape and deployment of bra cup pattern (3차원의 바람직한 유방형상 구현을 위한 Semi-Atomatic Protocol 개발 및 브래지어 컵 패턴으로의 전개)

  • Sohn, Boo-hyun;Kweon, Soo-ae
    • Journal of Fashion Business
    • /
    • v.20 no.4
    • /
    • pp.189-206
    • /
    • 2016
  • A breast model was for the human body was devised by studying a body scan and human body index of a desirable breast type. Thus, when manufacturing various 3D models, these results can accordingly become a fundamental basis for realizing a desirable breast model. This study aims to provide a basic data for designing the cup patterns of brassieres in order to improve the function and wearing comfort. The comfort of three kinds of brassieres were compared: one manufactured by the actual measured size; another manufactured as per the ratio of desirable upper and lower breast lengths; and the third manufactured by the 3D model attained by the desirable human body ratio. In this study, we suggest a process for realizing the desirable breast model using the ratio of bust breadth and waist front length, which are the components for deciding the appropriate position and size of breast, and which are easy to measure. The ideal breast shape is an equilateral triangle formed by connecting the nipple with the center of the clavicle. After deciding the interval between the nipples, this value can be used to configure the locations of nipples by drawing a tangent, with equal length, from the anterior neck point (which is the center of clavicle) to the nipple. Also, since inside points of breast do not exist, the outer point of breast, upper point of breast, and below point of breast on the same plane, and the depths from the nipple point to the respective points, are applied to simulate a 3D image, by modifications along the x, y, and z axes. Depending on the type of breast, the length from the center of shoulder to the nipple, the diameter of breast, upper length of breast, and the position of nipple, are different. In conical or protruding breast, the wearing sensation is better when the nipple point of brassiere was lifted, by modifying the upper and lower lengths of breast. Considering the wearing sensation and function of a brassiere, it was better to leave the wearer's size as it is and use a pad within the same cup, rather than increase the basal area of the breast in order to increase the volume.

Characteristics of Quality and Volatile Flavor Compounds in Raw and Frozen Pine-mushroom (Tricholoma matsutake) (생송이 버섯과 냉동송이 버섯의 품질 및 향기 성분 특성)

  • Ku, Kyung-Hyung;Cho, Myung-Hee;Park, Wan-Soo
    • Korean Journal of Food Science and Technology
    • /
    • v.34 no.4
    • /
    • pp.625-630
    • /
    • 2002
  • Raw pine-mushrooms (Tricholoma matsutake Sing.) of four grades and those frozen were analyzed for proximate composition, smell pattern, volatile flavor compounds, and sensory evaluation. Proximate compositions of raw pine-mushrooms (A-C, regular grade) were $89.48{\sim}90.77%$ moisture, 6.81% ash excluding D (below regular grade) sample, $2.24{\sim}2.52%$ crude lipid, and $16.19{\sim}20.01%$ crude protein. Proximate compositions of frozen pine-mushrooms preserved for 6 months at -20 and $-70^{\circ}C$ showed no difference compared with raw pine-mushrooms. Results of smell pattern and multidimensional analysis revealed raw pine-mushrooms showed no differences among samples, but frozen pine-mushrooms differed significantly depending on the grade. Volatile flavor compounds of pine-mushrooms were analyzed using a purge and trap method with GC/MSD. Twenty-nine volatile compounds were identified, among which alcohols such as 1-octen-3-ol, 2-octen-1-ol, 3-methyl-butanol, and n-octanol were commonly found in all pine-mushroom samples. In sensory attributes, raw pine-mushrooms were not significantly different at 5% level, and sample D of frozen pine-mushrooms scored lower than samples $A{\sim}C$.

Salivary Gland Uptake on 18F-FP-CIT PET as a New Biomarker in Patients With Parkinsonism

  • Seo Young Kang;Ji Young Yun;Yeon-Koo Kang;Byung Seok Moon;Hai-Jeon Yoon;Min Young Yoo;Bom Sahn Kim
    • Korean Journal of Radiology
    • /
    • v.24 no.7
    • /
    • pp.690-697
    • /
    • 2023
  • Objective: 18F-FP-CIT positron emission tomography (PET) is known for its high sensitivity and specificity for evaluating striatal dopamine transporter (DAT) binding. Recently, for the early diagnose of Parkinson's disease, many researchers focused on the diagnosis of synucleinopathy in organs involved in non-motor symptoms of Parkinson's disease. We investigated the feasibility of salivary gland uptake on 18F-FP-CIT PET as a new biomarker in patients with parkinsonism. Materials and Methods: A total of 219 participants with confirmed or presumed parkinsonism, including 54 clinically diagnosed idiopathic Parkinson's disease (IPD), 59 suspected and yet undiagnosed, and 106 with secondary parkinsonism, were enrolled. The standardized uptake value ratio (SUVR) of the salivary glands was measured on both early and delayed 18F-FP-CIT PET scans using the cerebellum as the reference region. Additionally, the delayed-to-early ratio (DE_ratio) of salivary gland was obtained. The results were compared between patients with different PET patterns. Results: The SUVR in early 18F-FP-CIT PET scan was significantly higher in patients with IPD pattern compared that in the non-dopaminergic degradation group (0.5 ± 0.19 vs. 0.6 ± 0.21, P < 0.001). Compared with the non-dopaminergic degradation group, the DE_ratio was significantly lower in patients with IPD (5.05 ± 1.7 vs. 4.0 ± 1.31, P < 0.001) or atypical parkinsonism patterns (5.05 ± 1.7 vs. 3.76 ± 0.96, P < 0.05). The DE_ratio was moderately and positively correlated with striatal DAT availability in both the whole striatum (r = 0.37, P < 0.001) and posterior putamen (r = 0.36, P < 0.001). Conclusion: Parkinsonism patients with an IPD pattern exhibited a significant increase in uptake on early 18F-FP-CIT PET and a decrease in the DE_ratio in the salivary gland. Our findings suggest that salivary gland uptake of dual-phase 18F-FP-CIT PET can provide diagnostic information on DAT availability in patients with Parkinson's disease.

Prediction of the Development of Pulmonary Fibrosis Using Serial Thin-Section CT and Clinical Features in Patients Discharged after Treatment for COVID-19 Pneumonia

  • Minhua Yu;Ying Liu;Dan Xu;Rongguo Zhang;Lan Lan;Haibo Xu
    • Korean Journal of Radiology
    • /
    • v.21 no.6
    • /
    • pp.746-755
    • /
    • 2020
  • Objective: To identify predictors of pulmonary fibrosis development by combining follow-up thin-section CT findings and clinical features in patients discharged after treatment for COVID-19. Materials and Methods: This retrospective study involved 32 confirmed COVID-19 patients who were divided into two groups according to the evidence of fibrosis on their latest follow-up CT imaging. Clinical data and CT imaging features of all the patients in different stages were collected and analyzed for comparison. Results: The latest follow-up CT imaging showed fibrosis in 14 patients (male, 12; female, 2) and no fibrosis in 18 patients (male, 10; female, 8). Compared with the non-fibrosis group, the fibrosis group was older (median age: 54.0 years vs. 37.0 years, p = 0.008), and the median levels of C-reactive protein (53.4 mg/L vs. 10.0 mg/L, p = 0.002) and interleukin-6 (79.7 pg/L vs. 11.2 pg/L, p = 0.04) were also higher. The fibrosis group had a longer-term of hospitalization (19.5 days vs. 10.0 days, p = 0.001), pulsed steroid therapy (11.0 days vs. 5.0 days, p < 0.001), and antiviral therapy (12.0 days vs. 6.5 days, p = 0.012). More patients on the worst-state CT scan had an irregular interface (59.4% vs. 34.4%, p = 0.045) and a parenchymal band (71.9% vs. 28.1%, p < 0.001). On initial CT imaging, the irregular interface (57.1%) and parenchymal band (50.0%) were more common in the fibrosis group. On the worst-state CT imaging, interstitial thickening (78.6%), air bronchogram (57.1%), irregular interface (85.7%), coarse reticular pattern (28.6%), parenchymal band (92.9%), and pleural effusion (42.9%) were more common in the fibrosis group. Conclusion: Fibrosis was more likely to develop in patients with severe clinical conditions, especially in patients with high inflammatory indicators. Interstitial thickening, irregular interface, coarse reticular pattern, and parenchymal band manifested in the process of the disease may be predictors of pulmonary fibrosis. Irregular interface and parenchymal band could predict the formation of pulmonary fibrosis early.

Evaluation of Reasonable $^{18}F$-FDG Injected Dose for Maintaining the Image Quality in 3D WB PET/CT (PET/CT 검사에서 영상의 질을 유지하기 위한 적정한 $^{18}F$-FDG 투여량의 평가)

  • Moon, A-Reum;Lee, Hyuk;Kwak, In-Suk;Choi, Sung-Wook;Suk, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.36-40
    • /
    • 2011
  • Purpose: $^{18}F$-FDG injected dose to the patient is quite different between the recommended dose from manufacturer and the actual dose applied to each of hospitals. injection of inappropriate $^{18}F$-FDG dose may not only increase the exposed dose to patients but also reduce the image quality. we thus evaluated the proper $^{18}F$-FDG injected dose to decrease the exposed dose to patients considering the image quality. Materials And Methods: NEMA Nu2-1994 phantom was filled with $^{18}F$-FDG increasing hot cylinder radioactivity concentration to 1, 3, 5, 7, 9 MBq/kg based on the ratio of 4:1 between the hot cylinder and background activity. after completing the transmission scan using ct, emission scan was acquired in 3D mode for 2 minutes 30 seconds/bed. ROI was set up on hot cylinder and background radioactivity region. after measuring $SUV_{max}$ those regions, then analyzed SNR at the points. clinical experiment has been conducted the object of patients who have came to smc from november 2009 to august 2010, 97 patients without having a hepatic lesions were selected. ROI was set up in the liver and thigh area. after measuring $SUV_{max}$, the image quality was compared following the injected dose. Results: in phantom study, as the injected radioactivity concentration per unit mass was 1, 3, 5, 7, 9 MBq/kg, $SUV_{max}$ was 23.1, 24.1, 24.3, 22.8, 23.6 and SNR was shown 0.48, 0.54, 0.56, 0.55, 0.55. according to increment of the injected dose, $SUV_{max}$ and SNR was increased under 5 MBq/kg but they were decreased over 7 MBq/kg. in case of clinical experiment, as increased the injected radioactivity concentration per unit mass was 4.72, 5.34, 6.16, 7.41, 8.68 MBq/kg, $SUV_{max}$ was 2.68, 2.67, 2.26, 1.88, 1.95 and SNR was shown 0.52, 0.53, 0.46, 0.46, 0.44. if the injected dose exceeds 5 MBq/kg, showed a decrease pattern as phantom study. Conclusion: increasing $^{18}F$-FDG injected dose considered patient's body weight improve image quality within a certain range. if it exceeds the range, it can be reduced image quality due to random and scatter coincidences. this study indicates that the optimal injected dose was 5 MBq/kg per unit mass the injected radioactivity concentration in 3d wb pet/ct.

  • PDF

Relationship between Pleural Adenosine Deaminase Level and Patterns of Pleural Enhancement in Patients with a Tuberculous Pleural Effusion on CT Scan (결핵성흉막염 환자에서 흉수 내 아데노신 탈아민효소(Adenosine deaminase)의 활성도와 CT에서 흉막의 조영증강 양상과의 연관성)

  • Lee, Hwa Yeun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.62 no.6
    • /
    • pp.486-491
    • /
    • 2007
  • Background: This study examined the relationship between the pleural adenosine deaminase (ADA) level and the patterns of pleural enhancement in patients with a tuberculous pleural effusion (TPE) shown on a CT scan. Methods: The charts and CT findings of 44 patients with TPE from February 2002 to October 2006 were reviesed retrospectively. A diagnosis of TPE was made by the pleural ADA level with a follow-up (24/44), sputum smear or culture of sputum (16/44), pleural fluid culture (3/44) or pleural biopsy (1/44). The patients were divided into two groups according to the ADA level(Group I [n=12]: 40-70, Group II [n=32]: >70 U/L). The presence or absence, maximal thickness and patterns of pleural enhancement were analyzed. The pattern of pleural enhancement was classified into diffuse or focal, smooth or irregular and interrupted or continuous. The difference in CT findings between groups I and group II were analyzed using an unpaired T test, Chi-square test and Z test. Results: All 44 patients showed diffuse pleural enhancement on the CT scans. The maximal pleural thickness of groups I and II was $1.83{\pm}1.03mm$ (1-4 mm) and $3.63{\pm}1.78mm$ (1-8 mm), respectively (p =0.0002). Pleural thickening ${\geq}5mm$ was only demonstrated in 31.3% of patients in group II (10/32). Diffuse interrupted pleural thickening was noted in 91.7% (11/12) of patients in group I and 62.5% (20/32) in group II, respectively. Diffuse continuous pleural thickening was observed in 8.3% (1/12) of patients in group I and 37.5% (12/32) in group II, respectively (p=0.0748). Conclusion: Pleural thickening ${\geq}5mm$ on the contrast enhanced CT is rare in patients with lymphocyte-dominant TPE in whom the pleural ADA level is between 40-70 U/L.

Characteristics of Visual Attention for the Different Type of Material Finishing in Cafe Space Using by Eye-tracking (시선추적을 이용한 카페 공간 마감재 차이의 시각주의력 특성)

  • Choi, Jin-Kyung;Kim, Ju-Yeon
    • Korean Institute of Interior Design Journal
    • /
    • v.27 no.2
    • /
    • pp.3-11
    • /
    • 2018
  • This study aims to investigate whether there is intensionally changing eye - gaze on the cafe space images with floor finishing materials. In the Yarbus' experiment, he argued that changing information that an observer is asked to obtain from an image changes pattern of eye movements. Based on the scan path evidence, this research have questions as (1) the difference of visual attention on finishing floor material stimulus, (2) visual attention of initial activity time and type of movement paths on AOIs, and (3) visual relation floor area with another AOIs. Eye movements were recorded with the SMI REDn Scientific, which sampled eye position at 30Hz and lasted 2 minutes(120s). Although viewing was binocular, only the right eye was tracked. Of the 66 observers(mean age 22 years, standard deviation: ${\pm}1.82$) who participated in the experiment done by the four point calibration and validation procedures at the beginning tasks. Analyzing qualitative data from the number of fixation and duration on AOIs divided into four parts (AOI I-Floor, AOI II-Wall, AOI III-Ceiling, and AOI IV-Counter) in the stimulus. The results from this experiment analyzed as follows. First, it was significant in the difference of the average number of AOIs fixation times observed for the spatial image using the wood tile flooring material and the polishing tile. The wood tile flooring of stimulus had higher fixation number on AOI-II, AOI-III, and AOI-IV than the polishing tile. On seeing AOI-I was higher attention in the polishing tile stimulus. Second, the observers examined AOI-II intensively in both stimuli. However, the visual intensity was also followed by on the AOI-IV and AOI-I in the wood tile flooring stimulus, and on AOI-I, AO-IV in the polishing tile. Third, visual attention data on each AOIs have divided into the time range of "5 sec" for both images. In the wood tile stimulus, the horizontal movement path followed by AOI-II, AOI-IV, and AOI-II. In the polished tile stimulus, the movement path followed by moving vertically to AOI-II, AOI-I, and AOI-II. This study approached meaningfully and found out the characteristics of visual attention, according to the different intentions of visual attention, the relationship pathways of visual mechanism appeared and also activated by eye-tracking experiments.

A new Clustering Algorithm for the Scanned Infrared Image of the Rosette Seeker (로젯 탐색기의 적외선 주사 영상을 위한 새로운 클러스터링 알고리즘)

  • Jahng, Surng-Gabb;Hong, Hyun-Ki;Doo, Kyung-Su;Oh, Jeong-Su;Choi, Jong-Soo;Seo, Dong-Sun
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.37 no.2
    • /
    • pp.1-14
    • /
    • 2000
  • The rosette-scan seeker, mounted on the infrared guided missile, is a device that tracks the target It can acquire the 2D image of the target by scanning a space about target in rosette pattern with a single detector Since the detected image is changed according to the position of the object in the field of view and the number of the object is not fixed, the unsupervised methods are employed in clustering it The conventional ISODATA method clusters the objects by using the distance between the seed points and pixels So, the clustering result varies in accordance with the shape of the object or the values of the merging and splitting parameters In this paper, we propose an Array Linkage Clustering Algorithm (ALCA) as a new clustering algorithm improving the conventional method The ALCA has no need for the initial seed points and the merging and splitting parameters since it clusters the object using the connectivity of the array number of the memory stored the pixel Therefore, the ALCA can cluster the object regardless of its shape With the clustering results using the conventional method and the proposed one, we confirm that our method is better than the conventional one in terms of the clustering performance We simulate the rosette scanning infrared seeker (RSIS) using the proposed ALCA as an infrared counter countermeasure The simulation results show that the RSIS using our method is better than the conventional one in terms of the tracking performance.

  • PDF

Comparative study on quality of scanned images from varying materials and surface conditions of standardized model for dental scanner evaluation (치과용 스캐너 평가를 위한 국제표준모델의 재료 및 표면 상태에 따른 스캔 영상 결과물 비교 연구)

  • Park, Ju-Hee;Seol, Jeong-Hwan;Lee, Jun Jae;Lee, Seung-Pyo;Lim, Young-Jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.2
    • /
    • pp.104-115
    • /
    • 2018
  • Purpose: The purpose of this study is to evaluate the image acquisition ability of intraoral scanners by analyzing the comprehensiveness of scanned images from standardized model, and to identify problems of the model. Materials and Methods: Cast models and 3D-printed models were prepared according to international standards set by ISO12836 and ANSI/ADA no. 132, which were then scanned by model scanner and two different intraoral scanners (TRIOS3 and CS3500). The image acquisition performance of the scanners was classified into three grades, and the study was repeated with varying surface conditions of the models. Results: Model scanner produced the most accurate images in all models. Meanwhile, CS3500 showed good image reproducibility for angled structures and TRIOS3 showed good image reproducibility for rounded structures. As for model ingredients, improved plaster model best reproduced scan images regardless of the type of scanner used. When limited to 3D-printed model, powdered surface condition resulted in higher image quality. Conclusion: When scanning structures beyond FOV (field of view) in standardized models (following ISO12836 and ANSI/ADA 132), lack of reference points to help distinguish different faces confuses the scanning and matching process, resulting in inaccurate display of images. These results imply the need to develop a new standard model not confined to simple pattern repetition and symmetric structure.

Subsidence Characteristics of Artificial Reefs using Sediment Grain Size and Shear Strength (퇴적물의 입도 및 전단강도를 이용한 인공어초 침하특성)

  • Kim, Ho-Sang;Kim, Chang-Gil;Seo, Young-Kyo;Kim, Gil-Young
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.41 no.1
    • /
    • pp.46-53
    • /
    • 2005
  • This paper describes the mean grain size and shear strength properties related to subsidence characteristics using sediment samples and acoustic images obtained from artificial reef areas in Tongyoung and Jangsungpo offshore. The acoustic images collected from chirp sonar and side scan sonar show well the attitude/orientation, the distribution pattern, and the degree of subsidence of artificial reefs, suggesting the possibility of suitable site investigation and the management of the reefs using acoustic sonar. The sediments were largely composed of clayey silt and silty clay. The mean grain sizes in Tongyoung and Jangsungpo offshore show the ranges of 5${\sim}$9${\Phi}$ and 8${\sim}$9${\Phi}$, respectively. The shear strength was significantly increased at the depths of 20cm in Tongyoung offshore and 80cm in Jangsungpo offshore, corresponding to the subsidence depth of artificial reefs. The relationship between mean grain size and shear strength did not show a correlation, suggesting the shear strength does not totally depend on mean grain size. Provided subsidence characteristics with respect to various artificial reefs and seabed condition are investigated in more details, the constructing area of the reef can be more extended.