• Title/Summary/Keyword: scan pattern

Search Result 397, Processing Time 0.033 seconds

Pattern of Ovulation in Korean Women with Premature Ovarian Failure (한국인 조기난소부전 여성의 배란양상)

  • Kim, Hye-Min;Kim, Jae-Ryoung;Choi, Eun-Joo;Park, Eun-Joo;Hong, Seo-Yu;Lee, Jin-Yong;Park, Won-Il
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.35 no.3
    • /
    • pp.231-238
    • /
    • 2008
  • Objective: Significant portion of premature ovarian failure patients ovulate intermittently and even can achieve pregnancy. The clinical features and reproductive potentials of Korean women with premature ovarian failure have never been elucidated. The purpose of this study is to assess ovarian follicular growth and ovulatory potential. Methods: Complete medical records of fifteen women with idiopathic premature ovarian failure were reviewed retrospectively. Subjects with more than 6 ultrasonographic scans and 36 months of follow-up period were included. Once the ovarian follicle was found by ultrasonography, the follicular growth was serially monitored. The result of ovulation induction of 6 cycles in 4 patients were also evaluated. Rate of positive ovarian follicle by ultrasound, rate of natural follicular growth and response of ovulation induction were assessed. Results: Among the 15 patients, 6 women (40%) had ovarian follicle in random ultrasonography. But the chance of positive follicle per ultrasonography scan was 7% (8 out of 115 scans). One out of 6 women eventually ovulated during the follow-up scan. In remaining 5 subjects, size of follicles remained unchanged. None of 6 ovulation induction cycles resulted successful ovulation. Conclusion: Incidence of positive ovarian follicle in Korean premature ovarian failure patients is lower than that of Western counterpart. This result, however, could not be directly compared because of the differences of study design. The ovulation rate by medical ovulation induction in this group is 0%, which is worse than the reported success rate of Western studies.

Ultrasonographic Features of Intra-abdominal Abscess (복부내 농양의 초음파 소견)

  • Cho, Kil-Ho;Jung, Kyung-Hee;Hwang, Mi-Soo;Chang, Jae-Chun;Kwun, Koing-Bo;Min, Hyun-Sik
    • Journal of Yeungnam Medical Science
    • /
    • v.2 no.1
    • /
    • pp.87-93
    • /
    • 1985
  • Intraabdommal abscess usually causes distress with fever, leukocytosis, pain and toxicity. Diagnosis of intraabdominal abscess is occasionally difficult and It has high morbidity. However radiologic method, such as ultrasonography, CT scan, or RI scan are helpful to early detection of intraabdominal abscess. Among these methods, ultrasonography is a non-invasive technique and performed without discomfort to patient. And also differential diagnosis between cystic and solid lesion is very easy and sequential ultrasonography in same patient is valuable for the evaluation of treatment effect. We analyzed the ultrasonic features of 48 cases with intra-abdominal abscesses and the results are as follows; 1. In total 48 cases, the intra-abdominal abscesses were 30 cases, the retroperitoneal abscesses, 5 cases, and the visceral abscesses, 13 cases. 2. The causes of the intra-abdominal abscesses were perforating appendicitis (25 cases), postoperative complications (5 cases), pyogenic and amebic hepatic abscesses (13 cases), and the others (5 cases). 3. Round or oval shaped lesions were 26 cases (54%), irregular shape, 18 cases (38%), and multiple abscess formation in 4 cases (8 %). 4. The size of the lesions were between 5 and 10cm in diameter in 54% of total 48 cases, and the most frequent feature of the echo-pattern of the lesions was cystic with or without internal echogenicity (69%).

  • PDF

Fixed prosthodontic rehabilitation of maxillary posterior teeth using functionally generated path technique and intraoral digital scan: Case report (Functionally generated path technique 및 구내 디지털 스캔을 이용한 상악 구치부의 고정성 보철 수복 증례)

  • Kim, Sung-Ho;Lee, Jonghyuk;Choi, Yu-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.3
    • /
    • pp.228-238
    • /
    • 2020
  • In order to deliver fixed partial denture to a patient successfully, dentist must take into many considerations beforehand. Patient's occlusal pattern should be fully understood before delivering any type of prosthesis, whether it's canine guidance or group function occlusion. In order to do so, movement of mandible should be recorded precisely. Introduced by Meyers in 1933, functionally generated path technique (FGP) has been successfully used to record mandibular movement with various materials, such as wax, and utilize it in fabricating precise prosthesis. In the following cases, patients showed secondary caries or endodontic-periodontic lesion on maxillary molars. Root canal treatment and subgingival curettage were done for each patient. Since the long term prognosis of each tooth was questionable, lateral force should be minimized. In order to do so, FGP technique was used to record mandibular movements precisely. Instead of using conventional plaster impression, intra-oral scanning of wax tracing was done to fabricate prosthesis efficiently. After delivery of fixed partial denture, favorable outcome was obtained.

Intratumoral distribution of 64Cu-ATSM and 18F-FDG in VX2tumor xenografted rabbit

  • Yoo, Ran Ji;Lee, Ji Woong;Lee, Kyo Chul;An, Gwang Il;Ko, In Ok;Chung, Wee Sup;Park, Ji Ae;Kim, Kyeong Min;Choi, Yang-Kyu;Kang, Joo Hyun;Lim, Sang Moo;Lee, Yong Jin
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.1 no.2
    • /
    • pp.123-129
    • /
    • 2015
  • $^{64}Cu$-labeled diacetyl-bis($N^4$-methylthiosemicarbazone) is a promising agent for internal radiation therapy and imaging of hypoxic tissues. In the study, we confirmed hypoxia regions in VX2 tumor implanted rabbits with injection $^{64}Cu$-ATSM and $^{18}F$-FDG using positron emission tomography (PET)/computed tomography (CT). PET images with $^{18}F$-FDG and $^{64}Cu$-ATSM were obtained for 40 min by dynamic scan and additional delayed PET images of $^{64}Cu$-ATSM the acquired up to 48 hours. Correlation between intratumoral $O_2$ level and $^{64}Cu$-ATSM PET image was analyzed. $^{64}Cu$-ATSM and $^{18}F$-FDG were intravenously co-injected and the tumor was dissected and cut into slices for a dual-tracer autoradiographic analysis. In the PET imaging, $^{64}Cu$-ATSM in VX2 tumors displayed a specific uptake in hypoxic region for48 h. The uptake pattern of $^{64}Cu$-ATSM in VX2 tumor at 24 and 48 h did not match to the $^{18}F$-FDG. Through ROI analysis, in the early phase (dynamic scan), $^{18}F$-FDG has positive correlation with $^{64}Cu$-ATSM but late phase (24 and 48 h) of the $^{64}Cu$-ATSM showed negative correlation with $^{18}F$-FDG. High uptake of $^{64}Cu$-ATSM in hypoxic region was responded with significant decrease of oxygen pressure, which confirmed by $^{64}Cu$-ATSM PET imaging and autoradiographic analysis. In conclusion, $^{64}Cu$-ATSM can utilize for specific targeting of hypoxic region in tumor, and discrimination between necrotic- and viable hypoxic tissue.

Comparative accuracy of implant impression techniques with different splinting materials (임플란트 인상채득 방법과 인상용 코핑 연결 고정에 따른 정확성 비교)

  • Ki-Yoon Hong;Soo-Yeon Shin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.39 no.1
    • /
    • pp.9-20
    • /
    • 2023
  • Purpose: We investigated the effect of open tray impression using pick-up impression coping and close tray impression using transfer impression coping on the accuracy of impression in edentulous patients on their mandibular parts. the effect of material types of pick-up type impression copings for splinting in open tray impression on the accuracy of impression was also evaluated. Materials and Methods: Two implant fixtures were implanted in parallel in the left molar of the mandibular in the shape of a mandibular partial edentulous model. The 40 individual trays were fabricated using 3D printer. The prepared individual trays were classified into 4 groups (i.e., PN, PG, PH, and TN groups), and a total of 40 impression-takings were conducted. A master cast was connected to a Scan Body. The converted STL file was super-imposed on the scan images of the various groups. Results: The order of standard deviation values decreased as follows: PN (0.2343 ± 0.0844 mm), TN (0.2192 ± 0.0840 mm), indicating that the high accuracy of impression for TN group. In addition, for the comparison results between the material types used in splinting the open tray impression, the PH group showed a relatively lower standard deviation (0.1910 ± 0.1176 mm) than that of the PN group (0.2343 ± 0.0844 mm), PG group (0.2556 ± 0.1082 mm). Conclusion: The acrylic resin synthesized by light-induced polymerization exhibited a higher accuracy of impression taking than that of autopolymerizing acrylic resin. Meanwhile, the accuracy of impression taking was not dependent on the implant impression taking method or the presence of connection/fixation of impression copings.

Comparative evaluation of marginal and internal fit of metal copings fabricated by various CAD/CAM methods (다양한 CAD/CAM 방식으로 제작한 금속하부구조물 간의 변연 및 내면 적합도 비교 연구)

  • Jeong, Seung-Jin;Cho, Hye-Won;Jung, Ji-Hye;Kim, Jeong-Mi;Kim, Yu-Lee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.211-218
    • /
    • 2019
  • Purpose: The purpose of the present study was to compare the accuracy of four different metal copings fabricated by CAD/CAM technology and to evaluate clinical effectiveness. Materials and methods: Composite resin tooth of the maxillary central incisor was prepared for a metal ceramic crown and duplicated metal die was fabricated. Then scan the metal die for 12 times to obtain STL files using a confocal microscopy type oral scanner. Metal copings with a thickness of 0.5 mm and a cement space of $50{\mu}m$ were designed on a CAD program. The Co-Cr metal copings were fabricated by the following four methods: Wax pattern milling & Casting (WM), Resin pattern 3D Printing & casting (RP), Milling & Sintering (MS), Selective laser melting (SLM). Silicone replica technique was used to measure marginal and internal discrepancies. The data was statistically analyzed with One-way analysis of variance and appropriate post hoc test (Scheffe test) (${\alpha}=.05$). Results: Mean marginal discrepancy was significantly smaller in the Group WM ($27.66{\pm}9.85{\mu}m$) and Group MS ($28.88{\pm}10.13{\mu}m$) than in the Group RP ($38.09{\pm}11.14{\mu}m$). Mean cervical discrepancy was significantly smaller in the Group MS than in the Group RP. Mean axial discrepancy was significantly smaller in the Group WM and Group MS then in the Group RP and Group SLM. Mean incisal discrepancies was significantly smaller in the Group RP than in all other groups. Conclusion: The marginal and axial discrepancies of the Co-Cr coping fabricated by the Wax pattern milling and Milling/Sintering method were better than those of the other groups. The marginal, cervical and axial fit of Co-Cr copings in all groups are within a clinically acceptable range.

Imaging Diagnosis of Central Giant Cell Granuloma Showing Massive Osteoid Material (다량의 골양물질을 형성한 중심성 거대세포육아종의 영상진단)

  • Lee Sol-Mie;Heo Min-Suk;Lee Sam-Sun;Choi Soon-Chul;Park Tae-Won
    • Imaging Science in Dentistry
    • /
    • v.30 no.2
    • /
    • pp.127-131
    • /
    • 2000
  • A 19-year-old man was referred to Seoul National University Dental Hospital for evaluation of a large painless swelling of the left mandibular angle area in August, 1999. The growth had been first noted 6 years ago. He had visited other hospital in 1997. In spite of the treatment given at the hospital, the mass continued to grow rapidly. Conventional radiographs in 1999 showed an expansile, lobulated, and destructive lesion of the left mandibular body. CT scan demonstrated an expansile mass with a corticated margin. Bony septa were seen within the lesion. Internal calcification noted on the bone-setting CT image, and corresponded to the hypointense area in T1-weighted MRI image. MRI clearly delineated the extent of the lesion which had heterogenous intermediate signal intensity in T1-weighted images and heterogenous hyperintense signal intensity in T2-weighted images. The lesion was well-enhanced. Histopathologically, the lesion was well demarcated. Multinucleated giant cells were presented in a fibrous background, demonstrating a storiform pattern. Areas of osteoid rimmed by a few osteoblasts were scattered throughout the lesion. Inflammatory cells, blood vessels, and hemosiderin deposition were also shown. CGCG may show lots of internal calcification foci on the CT, and varied signal intensity in MRI. More cases will be needed to understand the features of the CT & MR finding of CGCG.

  • PDF

MIDFACIAL MEASUREMENT USING OCCLUSAL MAXILLARY CT AND SURGICAL IMPLICATIONS OF MAXILLARY OSTEOTOMIES (컴퓨터 단층촬영을 이용한 중안모 계측과 상악골 절단술에의 응용)

  • Choung, Pill-Hoon;Yoo, Chung-Kyu;Lee, Eun-Kyung;Suh, Je-Duck;Chung, Il-Hyuk
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.28 no.3
    • /
    • pp.222-228
    • /
    • 2006
  • Various methods have been used in the past to indirectly analyze the craniofacial region. Among these, the lateral and posterior-anterior cephalometircs are used for the evaluation of the dentofacial deformities. However, cephalometircs create inaccuracies because of the inherent enlargement and distortion of the image. The interpretation of cephalometric films is also problematic: the number of anatomic landmarks that can be identified accurately is limited, and the overlap of structures on a radiograph making locating these landmarks difficult. To overcome these problems, computed tomography(CT) has been recommended as an useful modality in the diagnosis, surgical planning, and follow-up of craniofacial anomalies. There is no significant enlargement or distortion of the image, overlap of structure, or tracing error. And the number of anatomic landmarks is vast. The purpose of this study was to examine the orbit and midfacial region using Occlusal Maxillary CT, consisted of slices parallel to the occlusal plane. Based on these CT scan, we provide the data that could be applied to monitor an individual patient's skeletal pattern and the guide to the maxillary osteotomy.

Direct Patterning Technology of Indium Tin Oxide Layer using Nd:$YVO_4$ Laser Beam (Nd:$YVO_4$ 레이저 빔을 이용한 인듐 주석 산화물 직접 묘화 기술)

  • Kim, Kwang-Ho;Kwon, Sang-Jik
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.11
    • /
    • pp.8-12
    • /
    • 2008
  • For the reduction of fabrication cost and process time of AC plasma display panel (PDP), indium tin oxide (ITO) layer was patterned as bus electrode using Nd:$YVO_4$ laser. In comparison with the chemically wet etched ITO patterns, laser ablated ITO patterns showed the formation of shoulders and ripple-like structures at the edge of the ITO lines. For the reduction of shoulders and ripple-like structures, pulse repetition rate and scan velocity of laser was changed. In addition, we analyzed a discharge characteristic of PDP test panel to observe how the shoulders and ripple-like structures influence on the PDP. Based on experimental results, the pattern etched at the 500 mm/s and 40 kHz was better than any other condition. From this experiment we could see the possibility of the laser direct patterning for the application to the patterning of ITO in AC-PDP.

An Improved Method of Digital Watermarking Applied to Binary Printed Images (이진 프린트 영상에 적용하는 디지털 워터마킹의 성능 개선)

  • 김현주;곽내정;권혁봉;안재형
    • Journal of Korea Multimedia Society
    • /
    • v.4 no.3
    • /
    • pp.247-256
    • /
    • 2001
  • Digital watermarking is a copyright protection technique for digital images which embed a code into the digital data so the data is marked. Watermarking techniques previously deal with on-line digital data and have been developed to withstand digital attacks such image processing, compression and geometric transformation. In this paper we propose a novel method of embedding watermarks in printed images. In the proposed algorithm, watermark is embedded in a dithered binary image by comparing the $2\times{2}$ blocks of the counting array is the number of 1 (WHITE) in the $16\times{16}$ blocks of the dithered binary image with predefined reference block pattern, which is generated by watermark values. The proposed algorithm is able to provide more information at a watermark because the proposed algorithm use both '1'and '0' as watermark values. The watermark information is detected by comparing the watermark which is reconstructed from the image which is embedded watermark with the original watermark which is embedded in a binary image. The performance of the proposed algorithm is compared with that of the conventional watermark embedding algorithm for printed images by detecting watermark for scan images.

  • PDF