• Title/Summary/Keyword: scan mode

Search Result 197, Processing Time 0.027 seconds

Compensations of Polarization Mode Dispersion and Thermal Drift in Optical Coherence Tomography with PZT Optical Delay Lines (광간섭 단층촬영(OCT)용 PZT 광경로 지연기에서의 편광모드 분산 및 열요동 보상)

  • Kim, Young-Kwan;Park, Sung-Jin;Kim, Yong-Pyung
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.6
    • /
    • pp.547-552
    • /
    • 2005
  • We have fabricated and characterized optical delay lines for optical coherence tomography, which is composed of cylindrical PZT(piezoelectric transducer) and single mode optical fiber. The polarization mode dispersion from the optical delay lines was compensated by the polarization controllers. By applying the duplex optical delay line, we minimized the thermal drift due to optical delay lines and obtained the scan range of 2 times that of a single optical delay line. The OCT system showed resolution of $18.6\pm0.5{\mu}m$, scanning range of 1.68mm, and scanning speed of 360.4mm/s.

Discharge Characteristics of AC-PDP Having Auxiliary Electrodes (보조 전극을 가진 AC-PDP cell구조의 전기 광학적 특성)

  • Jang, Jin-Ho;Kang, Kyung-Il;Lee, Dong-Wook;Lee, Don-Kyu;Kim, Dong-Hyun;Lee, Ho-Jun;Park, Chung-Hoo
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1406-1407
    • /
    • 2007
  • 본 논문에서 제안한 ac-PDP(Plasma display panel) 셀구조는 Long gap의 전극 사이에 보조 전극을 삽입한 구조이다. 일반적으로, long gap 구조를 가진 PDP cell은 높은 방전 개시 전압을 가지므로, Long gap 전극 사이에 보조전극을 삽입하여 방전 개시 전압을 낮춤과 동시에 휘도 상승, 소비 전력의 감소효과로 발광효율의 향상을 가져왔다. 제안한 구조의 구동을 위하여 asymmetric mode와 long gap mode라는 2가지 파형을 가지고 실험하였다. 두 파형은 공통적으로 기존의 ADS(Address and Display period Separated)파형을 Y(Scan), Z(Common), A(Address) 전극에 인가하였으며, 보조적극에는 Z(Common) 전극의 파형을 수정한 형태로 인가하였다. Asymmetric mode는 보조전극에 Z(Common) 전극에 인가되는 파형과 같은 형태의 파형을 인가하여 Long gap의 구조를 가지지만 Short gap에서 방전이 가능하도록 설계하였고, long gap mode는 보조전극에 인가되는 Z(Common) 파형 중 sustain pulse를 초기 3개만을 주어 Short gap에서 방전을 개시함과 동시에 priming 입자를 생성하고, 나머지 sustain 구간에서는 floating시켜 이미 생성된 priming 입자를 long gap에서 구동을 가능하도록 하였다.

  • PDF

SPACEBORNE TOPS SAR SYSTEM MODELING AND PERFORMANCE ANALYSIS (TOPS 위성 SAR 모드 시스템 구현 및 성능 평가 연구)

  • Kang, Seo-Li;Song, Jeong-Hwan;Kim, Bum-Seung;Kim, Hyeon-Cheol;Lee, Woo-Kyung
    • Journal of Satellite, Information and Communications
    • /
    • v.9 no.2
    • /
    • pp.74-79
    • /
    • 2014
  • Conventional ScanSAR mode has been adopted in Envisat or Radarsat and played an important role to acquire wide swath SAR images for environmental surveillance. However, it suffers from the undesirable scalloping effect caused by non-homogeneity of antenna pattern while the image resolution is sacrificed. In recent years, TOPS mode has been suggested and put into use to overcome the disadvantages of the conventional scanning mode. Although TOPS mode is able to produce wide-swath SAR image in a short time interval, it demands highly complicated system design knowledge. In this paper, we present the operation principle of TOPS mode and a full SAR simulation is performed to generate TOPS SAR raw data. Azimuth antenna pattern is modified during TOPS mode operation and it is shown that the undesired scalloping effect is suppressed in the generated SAR image.

Investigation of the Effect of kV Combinations on Image Quality for Virtual Monochromatic Imaging Using Dual-Energy CT: A Phantom Study

  • Jeon, Pil-Hyun;Chung, Heejun;Kim, Daehong
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.1
    • /
    • pp.1-9
    • /
    • 2018
  • Background: In this study, we investigate the image quality of virtual monochromatic images synthesized from dual-energy computed tomography (DECT) at voltages of 80/140 kV and 100/140 kV. Materials and Methods: Virtual monochromatic images of a phantom are synthesized from DECT scans from 40 to 70 keV in steps of 1 keV under the two combinations of tube voltages. The dose allocation of dual-energy (DE) scan is 50% for both low- and high-energy tubes. The virtual monochromatic images are compared to single-energy (SE) images at the same radiation dose. In the DE images, noise is reduced using the 100/140 kV scan at the optimal monochromatic energy. Virtual monochromatic images are reconstructed from 40 to 70 keV in 1-keV increments and analyzed using two quality indexes: noise and contrast-to-noise ratio (CNR). Results and Discussion: The DE scan mode with the 100/140 kV protocol achieved a better maximum CNR compared to the 80/140 kV protocol for various materials, except for adipose and brain. Image noise is reduced with the 100/140 kV protocol. The CNR values of DE with the 100/140 kV protocol is similar to or higher than that of SE at 120 kV at the same radiation dose. Furthermore, the maximum CNR with the 100/140 kV protocol is similar to or higher than that of the SE scan at 120 kV. Conclusion: It was found that the CNR achieved with the 100/140 kV protocol was better than that with the 80/140 kV protocol at optimal monochromatic energies. Virtual monochromatic imaging using the 100/140 kV protocol could be considered for application in breast, brain, lung, liver, and bone CT in accordance with the CNR results.

Design of a CMOS x-ray line scan sensors (CMOS x-ray 라인 스캔 센서 설계)

  • Heo, Chang-Won;Jang, Ji-Hye;Jin, Liyan;Heo, Sung-Kyn;Kim, Tae-Woo;Ha, Pan-Bong;Kim, Young-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.10
    • /
    • pp.2369-2379
    • /
    • 2013
  • A CMOS x-ray line scan sensor which is used in both medical imaging and non-destructive diagnosis is designed. It has a pixel array of 512 columns ${\times}$ 4 rows and a built-in DC-DC converter. The pixel circuit is newly proposed to have three binning modes such as no binning, $2{\times}2$ binning, and $4{\times}4$ binning in order to select one of pixel sizes of $100{\mu}m$, $200{\mu}m$, and $400{\mu}m$. It is designed to output a fully differential image signal which is insensitive to power supply and input common mode noises. The layout size of the designed line scan sensor with a $0.18{\mu}m$ x-ray CMOS image sensor process is $51,304{\mu}m{\times}5,945{\mu}m$.

Accurate Measurement of Agatston Score Using kVp-Independent Reconstruction Algorithm for Ultra-High-Pitch Sn150 kVp CT

  • Xi Hu;Xinwei Tao;Yueqiao Zhang;Zhongfeng Niu;Yong Zhang;Thomas Allmendinger;Yu Kuang;Bin Chen
    • Korean Journal of Radiology
    • /
    • v.22 no.11
    • /
    • pp.1777-1785
    • /
    • 2021
  • Objective: To investigate the accuracy of the Agatston score obtained with the ultra-high-pitch (UHP) acquisition mode using tin-filter spectral shaping (Sn150 kVp) and a kVp-independent reconstruction algorithm to reduce the radiation dose. Materials and Methods: This prospective study included 114 patients (mean ± standard deviation, 60.3 ± 9.8 years; 74 male) who underwent a standard 120 kVp scan and an additional UHP Sn150 kVp scan for coronary artery calcification scoring (CACS). These two datasets were reconstructed using a standard reconstruction algorithm (120 kVp + Qr36d, protocol A; Sn150 kVp + Qr36d, protocol B). In addition, the Sn150 kVp dataset was reconstructed using a kVp-independent reconstruction algorithm (Sn150 kVp + Sa36d, protocol C). The Agatston scores for protocols A and B, as well as protocols A and C, were compared. The agreement between the scores was assessed using the intraclass correlation coefficient (ICC) and the Bland-Altman plot. The radiation doses for the 120 kVp and UHP Sn150 kVp acquisition modes were also compared. Results: No significant difference was observed in the Agatston score for protocols A (median, 63.05; interquartile range [IQR], 0-232.28) and C (median, 60.25; IQR, 0-195.20) (p = 0.060). The mean difference in the Agatston score for protocols A and C was relatively small (-7.82) and with the limits of agreement from -65.20 to 49.56 (ICC = 0.997). The Agatston score for protocol B (median, 34.85; IQR, 0-120.73) was significantly underestimated compared with that for protocol A (p < 0.001). The UHP Sn150 kVp mode facilitated an effective radiation dose reduction by approximately 30% (0.58 vs. 0.82 mSv, p < 0.001) from that associated with the standard 120 kVp mode. Conclusion: The Agatston scores for CACS with the UHP Sn150 kVp mode with a kVp-independent reconstruction algorithm and the standard 120 kVp demonstrated excellent agreement with a small mean difference and narrow agreement limits. The UHP Sn150 kVp mode allowed a significant reduction in the radiation dose.

Material Characterization of Weld-Zone Using Poisson's Ratio Distribution

  • Park, Jin-Ha;Kim, Young-H.;Lee, Seung-S.;Kim, Young-Gil
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.6
    • /
    • pp.586-590
    • /
    • 2009
  • Poisson's ratio, one of elastic constants of elastic solids, has not attracted attention due to its narrow range and difficult measurement. Transverse wave velocity as well as longitudinal wave velocity should be measured for nondestructive measurement of Poisson's ratio. Rigid couplants for transverse wave is one of obstacle for scanning over specimen. In the present work, a novel measurement of Poisson's ratio distribution was applied. Immersion method was employed for the scanning over the specimen. Echo signals of normal beam longitudinal wave were collected, and transverse wave modes generated by mode conversion were identified. From transit time of longitudinal and transverse waves, Poisson's ratio was determined without the information of specimen thickness. Poisson's ratio distribution of the carbon steel weldment was mapped. Heat affected zone of the weldment was clearly distinguished from base and filler metals.

A Variable Quantization Coefficient Scanning for Macroblock Considering the Histogram Value of Previous Macroblock's Quantization Coefficient (이전 매크로블록의 양자화계수 누적값을 이용한 매크로블록 마다 가변적인 양자화계수 탐색방법)

  • Hyun, Myung-Han
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.281-288
    • /
    • 2011
  • In this paper, a variable quantization coefficient scanning for macroblock considering the histogram value of previous macroblock's quantization coefficient is proposed. In order to scan a quantization coefficient, the proposed method makes $4{\times}4$ histograms for various prediction modes($16{\times}16$, $16{\times}8$, $8{\times}16$, $8{\times}8$) by adding 1 if the value of quantization coefficient is not 0. After a final mode decision procedure, the $4{\times}4$ histogram of the final mode will be sorted. Then, quantization coefficients in corresponding macroblock of the next frame are scanned using the sorted order. The experimental results show that the proposed scheme reduces the total bits by approximately 0.01~2.25% with similar PSNR performance compared with the previous method.

The Evaluation of Dose Reduction and Quality of Images According to 80 kVp of Scan Mode Change in Pediatric Chest CT (소아 흉부 CT 검사에서 관전압 80 kVp 조건으로 스캔 모드별 방사선량 감소와 화질 평가)

  • Kim, Gu;Kim, Gyeong-Rip;Lee, Eun-Sook;Cho, Hee-Jung;Sung, Soon-Ki;Moon, Seul-ji-a;Kwak, Jong-Hyeok
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.8
    • /
    • pp.284-292
    • /
    • 2019
  • To evaluate the usefulness of pediatric chest CT scans by comparing the dose, examination time, and image quality by applying Helical mode, High-pitch mode, and Volume Axial mode to minimize the radiation exposure and obtain high diagnostic value. Revolution (GE Healthcare, Wisconsin USA) was used to divide PBU-70 phantom into Helical mode, High-pitch mode, and Volume Axial mode. After acquiring images, ROI is set for each image, heart, bone, lung, and back-ground air, and the average value is obtained by measuring CT number (HU) and noise (SD). SNR and CNR were measured and compared with DLP values provided directly by the equipment. Determining statistical significance Statistical analysis was performed using ONE-WAY-ANAOVA using SPSS 21.0. In this experiment, it was possible to inspect at a short time without deterioration of image quality with the lowest dose when using volume axial mode. Although the detector coverage of 16 cm is limited to all pediatric chest CT scans, it is recommended to be actively used in pediatric patients, and further study is needed to apply other test sites in volume axial mode.