• Title/Summary/Keyword: scan mode

Search Result 197, Processing Time 0.024 seconds

A Parallel Mode Confocal System using a Micro-Lens and Pinhole Array in a Dual Microscope Configuration (이중 현미경 구조를 이용한 마이크로 렌즈 및 핀홀 어레이 기반 병렬 공초점 시스템)

  • Bae, Sang Woo;Kim, Min Young;Ko, Kuk Won;Koh, Kyung Chul
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.11
    • /
    • pp.979-983
    • /
    • 2013
  • The three-dimensional measurement method of confocal systems is a spot scanning method which has a high resolution and good illumination efficiency. However, conventional confocal systems had a weak point in that it has to perform XY axis scanning to achieve FOV (Field of View) vision through spot scanning. There are some methods to improve this problem involving the use of a galvano mirror [1], pin-hole array, etc. Therefore, in this paper we propose a method to improve a parallel mode confocal system using a micro-lens and pin-hole array in a dual microscope configuration. We made an area scan possible by using a combination MLA (Micro Lens Array) and pin-hole array, and used an objective lens to improve the light transmittance and signal-to-noise ratio. Additionally, we made it possible to change the objective lens so that it is possible to select a lens considering the reflection characteristic of the measuring object and proper magnification. We did an experiment using 5X, 2.3X objective lens, and did a calibration of height using a VLSI calibration target.

MTF measuring method of TDI camera electronics

  • Kim, Young-Sun;Kong, Jong-Pil;Heo, Haeng-Pal;Park, Jong-Euk;Yong, Sang-Soon;Choi, Hae-Jin
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.540-543
    • /
    • 2007
  • The modulation transfer function (MTF) in a camera system is a measurement of how well the system will faithfully reproduce the original scene. The electro-optical camera system consists of optics, an array of pixels, and an electronics which is related to the image signal chain. The system MTF can be cascaded with each element's MTF in the frequency domain. That is to say, the electronics MTF including the detector MTF can be recalculated easily by the acquired system MTF if the well-known test optics is used in the measuring process. A Time-Delay and Integration (TDI) detector can make a signal increase by taking multiple exposures of the same object and adding them. It can be considered the various methods to measure the MTF of the TDI camera system. This paper shows the actual and practical MTF measuring methods for the detector and electronics in the TDI camera. The several methods are described according to the scan direction as well as the TDI stages such as the single line mode and the multiple-lines mode. The measuring is performed in the in the static condition or dynamic condition to get the point spread function (PSF) or the line spread function (LSF). Especially, the dynamic test bench is used to simulate on track velocity to synchronize with TDI read out frequency for the dynamic movement.

  • PDF

Reconstructing Flaw Image Using Dataset of Full Matrix Capture Technique (Full Matrix Capture 데이터를 이용한 균열 영상화)

  • Lee, Tae-Hun;Kim, Yong-Sik;Lee, Jeong-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.37 no.1
    • /
    • pp.13-20
    • /
    • 2017
  • A conventional phased array ultrasonic system offers the ability to steer an ultrasonic beam by applying independent time delays of individual elements in the array and produce an ultrasonic image. In contrast, full matrix capture (FMC) is a data acquisition process that collects a complete matrix of A-scans from every possible independent transmit-receive combination in a phased array transducer and makes it possible to reconstruct various images that cannot be produced by conventional phased array with the post processing as well as images equivalent to a conventional phased array image. In this paper, a basic algorithm based on the LLL mode total focusing method (TFM) that can image crack type flaws is described. And this technique was applied to reconstruct flaw images from the FMC dataset obtained from the experiments and ultrasonic simulation.

DEVELOPMENT OF THE FAST IMAGING SOLAR SPECTROGRAPH FOR 1.6 m NEW SOLAR TELESCOPE (1.6 m 신태양망원경용 고속영상태양분광기 개발)

  • Nah, Ja-Kyoung;Chae, Jong-Chul;Park, Young-Deuk;Park, Hyung-Min;Jang, Bi-Ho;Ahn, Kwang-Su;Yang, Hee-Su;Cho, Kyung-Suk;Kim, Yeon-Han;Kim, Kwang-Dong;Cao, Wenda;Gorceix, Nicolas;Goode, Philip. R.
    • Publications of The Korean Astronomical Society
    • /
    • v.26 no.1
    • /
    • pp.45-54
    • /
    • 2011
  • KASI and Seoul National University developed the Fast Imaging Solar Spectrograph (FISS) as one of major scientific instruments for the 1.6 m New Solar Telescope (NST) and installed it in the Coude room of the NST at Big Bear Solar Observatory (BBSO) in May, 2010. The major objective of the FISS is to study the fine-scale structures and dynamics of plasma in the photosphere and chromosphere. To achieve it, the FISS is required to take data with a spectral resolution higher than $10^5$ at the spectrograph mode and a temporal resolution less than 10 seconds at the imaging mode. The FISS is a spectrograph using Echelle grating and has characteristics that can observe dual bands (H${\alpha}$ and CaII 8542) simultaneously and perform fast imaging using fast raster scan and two fast CCD cameras. In this paper, we introduce briefly the whole process of FISS development from the requirement analysis to the first observations.

A Case Report of Ventricular Septal Defect with Bacterial Endocarditis and Pulmonic Valve Vegetation (심실중격결손증 환자에서 심내막염 및 폐동맥판막 증식물이 관찰되었던 1예 보고)

  • Park, Wha-Chong;Kim, Young-Jo;Sim, Bong-Sup;Kim, Chong-Suhl;Lee, Dong-Hyup;Lee, Cheol-Joo;Cho, Bum-Koo
    • Journal of Yeungnam Medical Science
    • /
    • v.2 no.1
    • /
    • pp.241-247
    • /
    • 1985
  • Bacterial endocarditis has been well recognized as an important complication of congenital heart disease, such as ventricular septal defect, patent ductus arteriosus or pulmonary stenosis. The incidence of right sided bacterial endocarditis is lesser than left sided bacterial endocarditis. Also, pulmonic valve vegetation has been thought to be relatively uncommon. And pulmonary embolism is common in the patients with right sided bacterial endocarditis. So in a patient with fever and evidence of recurrent pulmonary infarction, changing heart murmurs and scattered pneumonic infiltrates, one should direct attention to the heart as a possible source of the infection. Echocardiography with M-mode, 2-D and Doppler mode represents the only noninvasive technic available for detecting vegetations in bacterial endocarditis. In fact, the technic is more sensitive in identifying these lesions than angiography. We experienced a case of ventricular septal defect with bacterial endocarditis, pulmonic valve vegetation and multiple pulmonary embolism diagnosed with Echocardiogram and lung scan, and confirmed by operation. Patch repair of ventricular septal defect, resection of pulmonic valve and vegetation and artificial valve formation with pericardium were done.

  • PDF

Hardware Implementation of Rasterizer with SIMD Architecture Applicable to Mobile 3D Graphics System (모바일 3차원 그래픽스 시스템에 적용 가능한 SIMD 구조를 갖는 래스터라이저의 하드웨어 구현)

  • Ha, Chang-Soo;Sung, Kwang-Ju;Choi, Byeong-Yoon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.313-315
    • /
    • 2010
  • In this paper, we describe research results of developing hardware rasterizer that is applicable to mobile 3D graphics system, designed in SIMD architecture and verified in FPGA. Tile-based scan conversion unit is designed like SIMD architecture running four tiles simultaneously and each tile traverses pixels hierarchical in 3-level so that visiting counts is minimized. As experimental results, $8{\times}8$ is the most efficient size of tile and the last step of tile traversing is performed on $2{\times}2$ sized subtile. The rasterizer supports flat shading and gouraud shading and texture mapper supports affine mapping and perspective corrected mapping. Also, texture mapper supports point sampling mode and bilinear interpolating sampling mode and two types of wrapping modes and various blending modes. The rasterzer operates as 120Mhz on xilinx vertex4 $l{\times}100$ device. To easy verification, texture memory and frame buffer are generated as block rom and block ram.

  • PDF

The Comparison of Quantitative Indices by Changing an Angle of LAO View in Multi-Gated Cardiac Blood Pool Scan (게이트 심장 혈액풀 스캔에서 좌전사위상 각도의 변화에 따른 정량적 지표 비교)

  • Yoon, Soon-Sang;Nam, Ki-Pyo;Ryu, Jae-Kwang;Kim, Seong-Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.57-61
    • /
    • 2012
  • Purpose: The multi-gated cardiac blood pool scan is to evaluate the function of left ventricle (LV) and usefully observe a value of ejection fraction (EF) for a patient who is receiving chemotherapy. To calculate LVEF, we should adjust an angle of left anterior oblique (LAO) view to separate both ventricles. And by overlapped ventricles, it is possible to affect LVEF. The purpose of this study is to investigate and compare quantitative indices by changing an angle of LAO view. Materials and methods: We analyzed the 49 patients who were examined by multi-gated cardiac blood pool scan in department of nuclear medicine at Asan Medical Center from June to September 2011. Firstly, we acquired "Best septal" view. And then, we got images by addition and subtraction of angle for LAO view to anterior and lateral. We compared three LAO views for 20 people by 5 degrees and 39 people by 10 degrees. And we analyzed quantitative indices, EF, end diastole and end systole counts, by automated and manual region of interest (ROI) modes. Results: Firstly, we analyzed quantitative indices by automated ROI mode. In case of 5 degrees, the averages of EF are $61.0{\pm}7.5$, $62.1{\pm}7.1$, $60.9{\pm}6.7%$ ($p$=0.841) in LAO, LAO $-5^{\circ}$ and LAO $+5^{\circ}$ respectively. And there is no difference in end diastole and end systole counts ($p$<0.05). In case of 10 degrees, the averages of EF are $62.4{\pm}9.5$, $62.3{\pm}10.8$, $61.6{\pm}.9.3%$ ($p$=0.938) in LAO, LAO $-10^{\circ}$ and LAO $+10^{\circ}$ respectively. And there is no difference in end diastole and end systole counts ($p$<0.05). Secondly, we analyzed quantitative indices by manual ROI mode. In case of 5 degrees, the averages of EF are $62.8{\pm}7.1$, $63.6{\pm}7.5$, $62.7{\pm}7.3%$ ($p$=0.903) in LAO, LAO $-5^{\circ}$ and LAO $+5^{\circ}$ respectively. And there is no difference in end diastole and end systole counts ($p$<0.05). In case of 10 degrees, the averages of EF are $65.5{\pm}9.0$, $66.3{\pm}8.7$, $63.5{\pm}.9.3%$ (p=0.473) in LAO, LAO $-10^{\circ}$ and LAO $+10^{\circ}$ respectively. And there is no difference in end diastole and end systole counts ($p$<0.05). Conclusion: When an image is nearly "Best septal" view, the difference of LAO angle would not affect to change LVEF. Although there was no difference in quantitative analysis, deviations could happen when to interpret wall motion qualitatively by reading physicians.

  • PDF

Quantitative Evaluation of the Accuracy of 3D Imaging with Multi-Detector Computed Tomography Using Human Skull Phantom (두개골 팬텀을 이용한 다검출기 CT 3차원 영상에서의 거리측정을 통한 정량적 영상특성 평가)

  • 김동욱;정해조;김새롬;유영일;김기덕;김희중
    • Progress in Medical Physics
    • /
    • v.14 no.2
    • /
    • pp.131-140
    • /
    • 2003
  • As the importance of accuracy in measurings of 3-D anatomical structures continues to be stressed, an objective and quantitative of assessing image quality and accuracy of 3-D volume-rendered images is required. The purpose of this study was to evaluate the quantitative accuracy of 3-D rendered images obtained with MDCT, scanned at various scanning parameters (scan modes, slice thicknesses and reconstruction slice thickness). Twelve clinically significant points that play an important role for the craniofacial bone in plastic surgery and dentistry were marked on the surface of a dry human skull. The direct distances between the reference points were defined as gold standards to assess the measuring errors of 3-D images. Then, we scanned the specimen with acquisition parameters of 300 mA, In kVp, and 1.0 sec scan time in axial and helical scan modes (pitch 3:1 and 6:1) at 1,25 mm, 2.50 mm, 3.75 mm and 5.00 mm slice thicknesses. We performed 3-D visualizations and distance measurements with volumetric analysis software and statistically evaluated the quantitative accuracy of distance measurements. The accuracy of distance measurements on the 3-D images acquired with 1.25, 2.50, 3,75 and 5.00 mm slice thickness were 48%, 33%, 23%, 14%, respectively, and those of the reconstructed 1.25 mm were 53%, 41%, 43%, 36% respectively. Meanwhile, there were insignificant statistical differences (P-value<0.05) in the accuracy of the distance measurements of 3-D images reconstructed with 1.25 mm thickness. In conclusion, slice thickness, rather than scan mode, influenced the quantitative accuracy of distance measurements in 3-D rendered images with MDCT. The quantitative analysis of distance measurements may be a useful tool for evaluating the accuracy of 3-D rendered images used in diagnosis, surgical planning, and radiotherapeutic treatment.

  • PDF

Application of a Boundary element Method to the Analysis of ultrasonic Scattering by Flaws (경계요소법을 이용한 결함의 초음파 산란장 해석)

  • Jeong, Hyun-Jo;Kim, Jin-Ho;Park, Moon-Cheol
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.11
    • /
    • pp.2457-2465
    • /
    • 2002
  • Numerical modeling of a nondestructive testing system plays an important role in many aspects of quantitative nondestructive evaluation (QNDE). The ultimate goal of a model is to predict test results for a specific flaw in a material. Thus, in ultrasonic testing, a system model should include the transducer, its radiation pattern, the beam reflection and propagation, and scattering from defects. In this paper attention is focused on the scattering model and the scattered fields by defects are observed by an elastodynamic boundary element method. Flaw types addressed are void-like and crack-like flaws. When transverse ultrasonic waves are obliquely incident on the flaw, the angular distribution of far-field scattered displacements are calculated and presented in the form of A-scan mode. The component signals obtained from each scattering problem are identified and their differences are addressed. The numerical results are also compared with those obtained by high frequency approximate solutions.

Stripping Voltammetric Determination of Osmium (벗김 전압전류법에 의한 오스뮴 정량)

  • Kwon, Young-Soon;Kim, So-Jin;Czae, Myung-Zoon
    • Analytical Science and Technology
    • /
    • v.10 no.2
    • /
    • pp.114-118
    • /
    • 1997
  • A stripping voltammetric scheme for the determination of osmium, based on the adsorptive accumulation of osmium in the presence of hydroxylamine, was described. Cyclic voltammetry was used to characterize the redox and interfacial processes. Optimal experimental conditions were found to be a stirred 0.05M hydroxylamine hydrochloride solution(pH 1.8), accumulation at -0.65V for 60s, and a differential pulse mode with a scan rate of 10mV/s. The detection limit was $6.3{\times}10^{-8}M$(12ppb) with the optimal condition.

  • PDF