• Title/Summary/Keyword: scale-model

Search Result 8,440, Processing Time 0.036 seconds

Shaking Table Test of Isolated EDG Model (면진된 모형 비상디젤발전기의 지진응답 실험)

  • Kim, Min-Kyu;Choun, Young-Sun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.3 s.55
    • /
    • pp.33-42
    • /
    • 2007
  • In this study, for research on an improvement of the seismic safety of an EDG system, a small scale EDG system was manufactured. For the isolation system, the Coil Spring-Viscous Damper systems were selected. For the shaking table test, 3 kinds of seismic motions were selected which had different frequency contents. In this study, the isolation effects were different and they depended on the input seismic motion. In the case of an NRC earthquake which had low fiequency contents, the isolation effects of the horizontal direction were 20%. But for the seismic motions which had high fiequency contents, the isolation effects were $50{\sim}70%$. In the case of the vertical direction, poor isolation effects were observed. It was because the design properties and the real properties of the isolation system were a little different.

Free Vibrations of Curved Members Resting on Elastic Foundation with Continuity Effect (연속성을 갖는 탄성지반 위에 놓인 곡선부재의 자유진동)

  • 이병구;박광규;오상진;진태기
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.14 no.3
    • /
    • pp.371-379
    • /
    • 2001
  • This paper deals with the free vibrations of horizontally curved members resting on elastic foundations with continuity effect. Taking into account the effects of rotatory inertia and shear deformation, differential equations governing the free vibrations of such beams are derived, in which the Pasternak foundation model is considered as the elastic foundation with continuity effect. The differential equations are solved numerically to calculate natural frequencies and mode shapes. The experiments were performed in which the natural frequencies of such curved beams in laboratorial scale were measured and these results agree quite well with the present numerical studies. In numerical examples, the circular, parabolic, sinusoidal and elliptic curved members with the hinged-hinged, hinged-clamped and clamped end constraints are considered. The parametric studies are conducted and the lowest four frequency parameters are reported in tables and figures as the non-dimensional forms. Also the typical mode shapes are presented.

  • PDF

Seismic Response Control of Structures Using Decentralized Response-Dependent MR Dampers (분산제어식 응답의존형 MR 감쇠기를 이용한 구조물의 지진응답제어)

  • Youn, Kyung-Jo;Min, Kyung-Won;Lee, Sang-Hyun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.6
    • /
    • pp.761-767
    • /
    • 2007
  • In centralized control system, complicated control systems including sensors, power supply and dampers should be required to satisfy the target response of large-scale structures. The practical applications of the centralized control system, however, is very difficult due to high order finite element model of structures, uncertainty of models, and limitations of the excitation system. In this study, the decentralized response-dependent MR damper of which magnetic field is automatically modulated according to the displacement or velocity transferred to the damper without any sensing and computing systems. this decentralized response-dependent MR damper are investigated according to the ranges of relative magnitude between the control force of MR damper and the story shear force of structures by nonlinear time history analysis. Finally, its performance is compared with centralized LQR algorithm which is used in general centralized control theory for a three story building structure.

A Study on Collecting Electrode Design for Developing Electrostatic Precipitator(ESP) of Urban Railway Underground Tunnels (도시철도 지하터널용 전기집진기 개발을 위한 집진극 형상에 대한 기초연구)

  • Koo, Tae Yong;Kim, Yong Min;Hong, Jung Hee;Hwang, Jungho
    • Particle and aerosol research
    • /
    • v.9 no.2
    • /
    • pp.79-87
    • /
    • 2013
  • In this study, the characteristics of turbulent flow and collection efficiency for an one-stage electrostatic precipitator(ESP) with slit type collecting electrode for urban railway underground tunnels were obtained using computational fluid dynamics(CFD) commercial code FLUENT 6.3 and lab-scale experiments. The electrostatic precipitator was operated under high gas velocity(3~12m/s). Five different designs of collecting electrode, flat plate-type and a slit-type of 3mm, 5mm, 7mm and 10mm slit width and four various gas velocity(3, 6, 9, and 12m/s) were used and applied. A standard k-${\varepsilon}$ model in CFD commercial code FLUENT 6.3 was used for flow simulation. The flow simulation results showed that the turbulent intensity of flat plate-type was higher than slit-type under all gas velocity conditions and also the turbulent intensity of flat plate-type was increased continuously, but in case of slit-type was maintained at constant range. And, the turbulent intensity was decreased according to increasing of slit width. The experimental results showed that the collection efficiency of slit-type was higher than flat plate-type under all gas velocity conditions. And, over 6m/s gas velocity condition, the collection efficiency of 5mm and 7mm was highest, when compared to 3mm and 10mm.

Virtual Flight Test for Conceptual Lunar Lander Demonstrator (달 착륙선 개념설계형상 검증모델 가상비행시험)

  • Lee, Won-Beom;Rew, Dong-Young
    • Aerospace Engineering and Technology
    • /
    • v.12 no.1
    • /
    • pp.87-93
    • /
    • 2013
  • The conceptual design lunar lander demonstrator has been developed to use as a test bed for advanced spacecraft technologies and to test a prototype planetary lander capable of vertical takeoff and landing. Size of the lunar lander demonstrator is the same as that of lunar lander conceptually designed, however, the weight of lunar lander demonstrator is designed in 1/6 scale in consideration of gravity difference between moon and earth. The thruster clustering and virtual flight test were performed in the demonstrator fixed on the ground. The demonstrator ground test has been conducted for two months in the test site for the solid motor combustion of the Goheung Flight Center. The purposes of ground test of demonstrator are to demonstrate and verify essential electronics, propulsion system, control algorithm, embedded software, structure and system operation technologies before developing the flight model lander. This paper is described about the virtual flight test including test configuration, test aims and test facilities

Factors associated with Maternal-fetal Attachment of Expectant Mothers Whose Fetus Has a Prenatal Diagnosis of Congenital Heart Disease (선천성 심장병 태아를 임신한 임부의 모-태아 애착 및 관련 요인)

  • Im, Yu-Mi;Kim, Eun-Sook;Yoo, Il-Young
    • Child Health Nursing Research
    • /
    • v.18 no.3
    • /
    • pp.150-156
    • /
    • 2012
  • Purpose: The main purposes of this study were to assess maternal-fetal attachment (MFA) of the expectant mothers of a fetus with a prenatal diagnosis of congenital heart disease (CHD) and to identify factors associated with MFA. Methods: The methodology was a cross sectional survey study using a self-administered questionnaire. Thirty pregnant women carrying a fetus with a prenatal diagnosis of CHD and 30 pregnant women with a normal fetus were enrolled in this study. The MFA Scale and PPS (The Prenatal Psychosocial Profile) were used to collect data. Data were analyzed using SPSS 20.0 Window version. Descriptive statistics, $X^2$-test and t-test were used to compare the two groups. The factors associated with MFA were identified by multiple regression analysis. Results: There was no significant difference between the two groups in MFA and social support from spouse was the only variable showing a significant difference. The model from the multiple regression analysis explained 33.8% of MFA for both groups. Conclusion: MFA of expectant mothers with a prenatal diagnosis of CHD and of mothers with a normal fetus were not significantly different. It is important that health care providers encourage expectant fathers to support the expectant mothers to increase MFA.

An electromechanical impedance-based method for tensile force estimation and damage diagnosis of post-tensioning systems

  • Min, Jiyoung;Yun, Chung-Bang;Hong, Jung-Wuk
    • Smart Structures and Systems
    • /
    • v.17 no.1
    • /
    • pp.107-122
    • /
    • 2016
  • We propose an effective methodology using electromechanical impedance characteristics for estimating the remaining tensile force of tendons and simultaneously detecting damages of the anchorage blocks. Once one piezoelectric patch is attached on the anchor head and the other is bonded on the bearing plate, impedance responses are measured through these two patches under varying tensile force conditions. Then statistical indices are calculated from the impedances, and two types of relationship curves between the tensile force and the statistical index (TE Curve) and between statistical indices of two patches (SR Curve) are established. Those are considered as database for monitoring both the tendon and the anchorage system. If damage exists on the bearing plate, the statistical index of patch on the bearing plate would be out of bounds of the SR curve and damage can be detected. A change in the statistical index by damage is calibrated with the SR curve, and the tensile force can be estimated with the corrected index and the TE Curve. For validation of the developed methodology, experimental studies are performed on the scaled model of an anchorage system that is simplified only with 3 solid wedges, a 3-hole anchor head, and a bearing plate. Then, the methodology is applied to a real scale anchorage system that has 19 strands, wedges, an anchor head, a bearing plate, and a steel duct. It is observed that the proposed scheme gives quite accurate estimation of the remaining tensile forces. Therefore, this methodology has great potential for practical use to evaluate the remaining tensile forces and damage status in the post-tensioned structural members.

Exercise Self-Efficacy as a Mediator between Goal-Setting and Physical Activity: Developing the Workplace as a Setting for Promoting Physical Activity

  • Iwasaki, Yoshie;Honda, Sumihisa;Kaneko, Shuji;Kurishima, Kazuhiro;Honda, Ayumi;Kakinuma, Ayumu;Jahng, Doosub
    • Safety and Health at Work
    • /
    • v.8 no.1
    • /
    • pp.94-98
    • /
    • 2017
  • Background: Physical activity (PA) is ranked as a leading health indicator and the workplace is a key setting to promote PA. The purpose of this study was to examine how goal-setting and exercise self-efficacy (SE) during a health promotion program influenced PA level among Japanese workers. Methods: Using a cross-sectional study design, we surveyed 281 employees. The short version of the International Physical Activity Questionnaire was used to assess PA level. Exercise SE was assessed using a partially modified version of Oka's exercise SE scale. Personal goals were assessed as the total numbers of "yes" responses to five items regarding "details of personal goals to perform PA". A mediational model was used to examine whether exercise SE mediates between the number of personal goals and PA level. Results: The mean age of the participants was 46.3 years, 76.2% were men, and the most common occupational category was software engineer (30.6%). The average PA level per week exceeded the recommended level in 127 participants (45.2%). One hundred and eighty-four participants (65.5%) set some form of concrete personal goal to perform PA. The relationship between the number of personal goals and PA level was mediated by exercise SE. Conclusion: Our study showed that exercise SE mediates goal-setting and increases PA. The results suggest that the components of PA promotion programs should be tailored to enhance participants' confidence in performing PA.

A Study on Model for the Evaluation of Customer Composition in Internet Shopping Malls (인터넷 쇼핑몰의 고객구성 평가 모델에 관한 연구)

  • Park, Kwang-Ho;Han, Dong-Seok;Kim, Hak-So;Baek, Dong-Hyun
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.29 no.2
    • /
    • pp.83-91
    • /
    • 2006
  • Internet shopping mall has become a huge distribution channel with dramatic growth in recent years. The number of consumers has exponentially increased as the scale of shopping mall has been large so that shopping malls with thousands or millions of consumers become a general case. However, it is essential to evaluate whether current assortment of consumers is proper or not in the strategic aspect in order to operate Internet shopping mall effectively and gain profits. That is, it is important to evaluate whether consumer strategy of corporation is proper or not from the corporation. Despite this business importance, consumer assortment has not been evaluated well and related study is not sufficient. This study supposes a framework for consumer assortment evaluation, which evaluates whether consumer assortment of Internet shopping mall is proper or not. In the framework for consumer assortment evaluation, analysis data based on order data and consumer data in database is made. Then, four factors, consumer maintenance rate, consumer profitability, consumer securing rate and consumer conversion are setup, and 22 measurement indexes are drawn. Finally, a consumer assortment evaluation score card is made by integrating them. This study has applied a supposed framework to a domestic typical community based shopping mall, and it is expected that the evaluation result will be used as informant strategic information to operate the shopping mall effectively.

A Study on the Deduction of Internal Temperature of the Ground Magazine (지상형 탄약고의 내부온도 감소 방안 연구)

  • Park, Hyungju;Choi, Myoungjin;Yang, Jaekyung
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.36 no.3
    • /
    • pp.142-149
    • /
    • 2013
  • Among ammunitions which are stored in a war field, the lifespan of propelling gunpowder is affected by storage environment such as storage temperature, humidity, and exposure to sunlight. These are because Nitrocellulose (NC) which is the main component of propelling gunpowder can be naturally disassembled to unstable substances similar with other nitric acid ester. We can't prevent it fundamentally from being disassembled, but to restrain induction of automatic disassembly by decomposition product, a decomposition product ($NO_2$, $NO_3$, and $HNO_3$) and tranquillizer DPA (Diphenylamine), having high reactivity, are added into a propellant. For this, it will decrease the velocity of tranquillizer which can also affect the velocity of producing the decomposition product of NC, storage temperature or humidity of propelling gunpowder is higher, drop of tranquillizer content is much faster. Therefore, to extend storage lifespan of propelling gunpowder, it is really important to control storage temperature or humidity inside the magazine. Hereupon, according to the manufacture of small scale model magazine and the result of performing experiments and measuring variation of inside temperature (storage temperature), using roof types that have a steel slate structure of magazine among ground magazines, this research shows the differences in details.