• Title/Summary/Keyword: scale-model

Search Result 8,446, Processing Time 0.032 seconds

Mediation Role of Satisfaction and Trust on Attitudinal Commitment and Relationship Quality

  • TRAN, Thi Trang;TRAN, Anh Tung;PHAM, Thi Ngan
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.7 no.10
    • /
    • pp.275-281
    • /
    • 2020
  • This study aims to explore a new approach of relationship assessment by partially employing attitudinal commitment to measure the influence on perception of cooperation within the Vietnamese rice supply chains, which begins from commercial enterprises up to the retailers in the Vietnamese market. The quantitative research is first built around the measurement instruments for the constructs of relationship quality (RQ) and its dimensions; next, a questionnaire is designed; finally, we deal with sample issues and analyze the data to answer the research questions. The truncated sampling technique and Likert-scale survey is a suitable method for analyzing Vietnamese rice retailers and data collection. The preliminary test was conducted using SPSS Statistics; the main test was, then, carried out to evaluate the proposed model and test the hypotheses. Appropriately, the results point to a significant influence of attitudinal factors on trust and satisfaction. In addition, with the involvement of perceived trust and satisfaction, that combination showed the mediating effect between the attitudinal factors and the relationship quality. The ad-hoc analysis indicated the significant role of the two mediators. To be more specific, the high degree of trust and satisfaction has a positive impact on the formation of the relationship between participants in the sector.

A Study on the Flue Gas Mixing for the Performance Improvement of De-NOx plant (배연탈질설비의 성능향상을 휘한 가스혼합에 관한 연구)

  • 류병남
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.4
    • /
    • pp.462-472
    • /
    • 1999
  • De-NOx facility using Selective Catalytic Reduction method is the most widely applied one that removes NOx from flue gas emitted from combustion facility such as boiler for power generation engine incinerator etc. Reductant $NH_3\;or\;NH_4OH$ is sprayed into flue gas to convert NOx into $H_2O$ and $N_2.$ Good mixing between flue gas and $NH_3$ is the most important factor to increase reduction in catalytic layer and to reduce unreacted NH3 slip. Therefore the development of mixer device for mixing effect is one of the important part for SCR facility. Objectives of this study are to investigate the relation between flow and concentration field by observation at the wake of delta-wing type mixer. At the first stage qualitative measurement of flow field is conducted by flow visualization using laser light sheet in lab. scale wind tunnel. Also we have conducted the quantitative analysis by comparing flow field measurement using LDV with numerical simulation. On the basis of qualitative and quantitative analysis we investigate the dis-tribution of flow and concentration in flow model facility. The results of an experimental and compu-tational examination of the vortex structures shed from delta wing type vortex generator having $40^{\circ}$ angle of attack are presented, The effects of vortex structure on the gas mixing is discussed, too.

  • PDF

Analysis on Visual Perception and Mood for Color of Light in a Small Office (소규모 사무실의 조명 색 변화에 따른 시각적 감지 및 무드 변화 분석)

  • Kang, Min-Hye;Kim, Soo-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.4
    • /
    • pp.287-296
    • /
    • 2011
  • This study examines the influences of correlated color temperature and illuminance on visual perception and temporary mood sensation in a small office. Field measurements and surveys were conducted in a full-scale mock-up model. Twenty subjects participated in the survey under six lighting conditions formed by three color temperature and two illuminance levels. Results indicate that 4000 K color temperature was effective to mitigate glare sensation from light source. Lamps with low color temperature such as 2700 K was not recommended for office lighting since they are likely to caused glare and visual discomfort. Preferred color temperature was 4000 K and 6500 K for 750 lx and 500 lx target illuminance respectively. The increase of illuminance was not an effective contributor to improve mood perception. The illuminance should be lower than 500 lx to achieve good mood, but the illuminance level in office space should be considered with visual performance simultaneously. This study suggests that fluorescent lighting fixtures with 4000 K lamps would be usefully used for office lighting since they formed friendly conditions for better visual performance.

Analyses on Photosensor Illuminance for Prediction of Fluctuating Illuminance by Daylight Dimming Control Systems (조광제어 시스템 적용시 실내조도의 변동예측을 위한 포토센서의 주광조도 분석)

  • Kim, Soo-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.11
    • /
    • pp.788-797
    • /
    • 2010
  • This study examines the influence of fluctuating daylight illuminance on daylight dimming control systems. Field measurements were performed for a full-scale mocked-up model under various daylight conditions in winter. Fluctuating ranges for a partially-shielded photosensor were great when the variation of sky ratio was great. When solar altitude was lower the illuminance and fluctuating range of illuminance were great due to the influence of direct components of daylight and the interrefelction between surfaces in rear area of space. It implies that daylight dimming system would not function effectively, unless the desktop illuminance by daylight is enough. Fluctuation ranges of photosensor illuminance were lower than 50 lx under clear sky conditions, but they were greater than 100 lx under partly-cloudy sky conditions. It means that the fluctuation range of electric light output of lighting fixture would greater under the partly-cloudy conditions and cause potential visual annoyance to occupants. Outdoor vertical illuminance reaching the windows would be an effective factor that can be used to predict the fluctuation of photosensor signals for effective controls of daylight dimming system.

Allocation of the Optimal Reliability and Maintainability in Manufacturing Systems (제조 시스템의 최적 신뢰도 및 보전도 할당)

  • 이상철
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.22 no.50
    • /
    • pp.23-32
    • /
    • 1999
  • Reliability and maintainability allocation in the analysis of the system's design, with the objective of planning and installing the individual components in such a way that the system performance is achieved. This paper has been made to solve an important task in reliability management of manufacturing systems within the general objective being to increase productivity while maintaining costs low. Thus, the purpose of this paper is to provide an analytical approach to determine an optimal reliability and maintainability allocation, trading off among system performance and parts investment costs. Two important considerations will be addressed in this regard : (ⅰ) determine the reliability and maintainability allocation of parts which maximizes a given production index, having fixed the total cost of investments ; and (ⅱ) determine the reliability and maintainability allocation which minimizes the total cost of investments, having fixed a minimum acceptable level of productivity. The procedure proposed in this paper is able to provide to managers and designers useful indications on the reliability and maintainability characteristics of parts in series -parallel systems. And this heuristic model is a decision support tool for contractors who are involved in large scale design projects such as ship and aircraft design. Numerical examples prove that an approximate expression of the average throughput rate is sufficiently accurate to be used in a numerical optimization method.

  • PDF

A Study of a Correlation between Experiments and Calculations of Pressure Fluctuation on Hull Surface (선체 변동 압력에 관한 실험과 이론의 비교 연구)

  • Moon-Chan Kim;Ki-Sup Kim;In-Haeng Song
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.33 no.1
    • /
    • pp.19-26
    • /
    • 1996
  • An experimental and computational study of the pressure fluctuation induced by a propeller on a hull surface was carried out with three ship models and seven model propellers. The fluctuation of pressure on a flat plate was measured at KRISO cavitation tunnel and calculated by a panel and lifting surface method(XForShip code). To extend the measurement data on the flat plate into that on complex hull forms, the correction factor was determined as a ratio of the solid boundary factor(SBF). The computation of pressure fluctuation around complex hull forms was also performed to make the full scale prediction and compared with the corrected experimental data. The calculated values agreed well with the compensated experimental data and it was found that the correction factor was about 0.65-0.7.

  • PDF

VLSI Implementation of Forward Error Control Technique for ATM Networks

  • Padmavathi, G.;Amutha, R.;Srivatsa, S.K.
    • ETRI Journal
    • /
    • v.27 no.6
    • /
    • pp.691-696
    • /
    • 2005
  • In asynchronous transfer mode (ATM) networks, fixed length cells of 53 bytes are transmitted. A cell may be discarded during transmission due to buffer overflow or a detection of errors. Cell discarding seriously degrades transmission quality. The quality degradation can be reduced by employing efficient forward error control (FEC) to recover discarded cells. In this paper, we present the design and implementation of decoding equipment for FEC in ATM networks based on a single parity check (SPC) product code using very-large-scale integration (VLSI) technology. FEC allows the destination to reconstruct missing data cells by using redundant parity cells that the source adds to each block of data cells. The functionality of the design has been tested using the Model Sim 5.7cXE Simulation Package. The design has been implemented for a $5{\times}5$ matrix of data cells in a Virtex-E XCV 3200E FG1156 device. The simulation and synthesis results show that the decoding function can be completed in 81 clock cycles with an optimum clock of 56.8 MHz. A test bench was written to study the performance of the decoder, and the results are presented.

  • PDF

Sustainable Vibration Energy Harvesting Based on Zr-Doped PMN-PT Piezoelectric Single Crystal Cantilevers

  • Moon, Seung-Eon;Lee, Sung-Q;Lee, Sang-Kyun;Lee, Young-Gi;Yang, Yil-Suk;Park, Kang-Ho;Kim, Jong-Dae
    • ETRI Journal
    • /
    • v.31 no.6
    • /
    • pp.688-694
    • /
    • 2009
  • In this paper, we present the results of a preliminary study on the piezoelectric energy harvesting performance of a Zr-doped $PbMg_{1/3}Nb_{2/3}O_3-PbTiO_3$ (PMN-PZT) single crystal beam. A novel piezoelectric beam cantilever structure is used to demonstrate the feasibility of generating AC voltage during a state of vibration. The energy-harvesting capability of a PMN-PZT beam is calculated and tested. The frequency response of the cantilever device shows that the first mode resonance frequency of the excitation model exists in the neighborhood of several hundreds of hertz, which is similar to the calculated value. These tests show that several significantly open AC voltages and sub-mW power are achieved. To test the possibility of a small scale power source for a ubiquitous sensor network service, energy conversion and the testing of storage experiment are also carried out.

Study on Stabilizable Interconnected system by Decentralized Control (분산 제어로 안정 가능한 대형 시스템에 대하여)

  • 이종수;최종호
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.19 no.4
    • /
    • pp.15-20
    • /
    • 1982
  • Stabilization by decentralized control is an important problem in large scale systems and there has been an increasing interest in this area. The objective of this paper is to obtain the sufficient condition for an interconnected system to be stabilited by local feedback. Recently there has been many papers about this, and we further broaden the class of interconnections for which we can find a decentralized control to stabilize the overall system. The interconnection matrix may take any arbitrary time invariant values and this implies connective stability in some sense. The assumed model is mire general than most of previous ones, and as a special case, when each subsystem is given by companion form of a single inputs the result is compared with that of Ikeda and Siljak. The obtained result is illustrated by examples.

  • PDF

Development of a Converter for Visualizing SEDRIS (SEDRIS 합성 환경 데이터 가시화를 위한 변환기 개발)

  • Kang, Yuna;Kim, Hyungki;Han, Soonhung;Kim, Man Kyu
    • Korean Journal of Computational Design and Engineering
    • /
    • v.18 no.3
    • /
    • pp.189-199
    • /
    • 2013
  • The need for reusing synthetic environment data that are employed in the field of modeling and simulation has recently been rising. SEDRIS (Synthetic Environment Data Representation & Interchange Specification) is a standard to exchange synthetic environment data, and is the specification utilized in various military simulations of the Pentagon for representing and exchanging 3D data. SEDRIS represents environmental areas based on a data model; it can represent wind speed, wind directions, weather changes, the information of buildings, as well as terrain data. In some situations, however, the synthetic environment data stored in SEDRIS format should be converted to various visualization formats. First, because SEDRIS is a form of a super-set, it is necessary to verify whether large scale SEDRIS files are stored successfully through visualization. Second, the synthetic environment data should be visualized in some visualization programs for the simulation results to provide an immersive and realistic sense. In this study, we have developed converters for converting SEDRIS data to various visualization formats and visualized the converted results.