• Title/Summary/Keyword: scale removal

Search Result 1,231, Processing Time 0.035 seconds

Treatment of Acute Acromioclavicular Joint Injuries Using AO Hook Locking Plate

  • Kim, Kyung Cheon;Jeon, Yoo Sun
    • Clinics in Shoulder and Elbow
    • /
    • v.17 no.3
    • /
    • pp.114-119
    • /
    • 2014
  • Background: To evaluate clinical and radiological outcome using AO hook locking plate in acute acromioclavicular joint injuries. Methods: This study was based on patients with Rockwood type 3 or 5 acromioclavicular joint injuries who received surgery with AO hook locking plate from June 2008 until June 2009. Among the 22 patients, 19 of them were male and 3 were female, the mean age was $44.4{\pm}15.57$ years (20-72 years) and follow-up period was $15.5{\pm}3.90$ months (12-23 months). Preoperatively, postoperatively, and at the final follow-up after the plate removal, both coracoclavicular distances were measured from the anteroposterior radiograph. Also, the Shoulder Rating Scale of the University of California at Los Angeles scores (UCLA scores), the American Shoulder and Elbow Surgeons scores (ASES scores), Constant scores, and the Korean Shoulder Society scores (KSS scores) were measured at the final followup to evaluate the function of the shoulder joint. Results: At the time of injury, the mean coracoclavicular distance of the injured side was $17.69{\pm}4.23mm$ (9.57-27.82 mm) and the unaffected side was $7.55{\pm}2.20mm$ (3.24-13.05 mm). The mean coracoclavicular distance measured postoperatively and at the final follow-up was $6.87{\pm}2.34mm$ (4.07-14.13 mm) and $8.47{\pm}2.96mm$ (4.37-17.48 mm), respectively. The mean UCLA, ASES, Constant, and KSS scores measured in the final follow-up were $33.5{\pm}1.30$ (31-35), $90.8{\pm}8.36$ (72-100), $78.6{\pm}8.80$ (62-100), and $94.4{\pm}5.08$ (84-100) each. Conclusions: From this short-term research, the surgical treatment using AO hook locking plates in acute acromioclavicular joint injuries is clinically and radiographically satisfying and considered as a useful treatment method.

Coracoclavicular Ligament Suture Augmentation with Anatomical Locking Plate Fixation for Distal Clavicle Fracture

  • Lim, Tae Kang;Shon, Min Soo;Ryu, Hyung Gon;Seo, Jae Sung;Park, Jae Hyun;Ko, Young;Koh, Kyoung-Hwan
    • Clinics in Shoulder and Elbow
    • /
    • v.17 no.4
    • /
    • pp.175-180
    • /
    • 2014
  • Background: For Neer type IIB fracture of distal clavicle with coracoclavicular ligament injury, various surgical treatments have been used in literatures. However, there was no consensus on the optimal treatment. The aim of this study is to report the clinical and radiological results of open reduction and internal fixation of unstable distal clavicle fracture and suture augmentation of disrupted coracoclavicular ligament. Methods: A prospective study was performed in 23 patients with Neer type IIB distal clavicle fracture in Seoul Medical Center, Eulji Hospital, and National Medical Center. Firstly, suture anchors are inserted in the base of coracoid process and preliminary reduction was achieved by tie-off of three suture limbs around the clavicle. Then, the final fixation was completed with anatomical locking plate. Bony union and the distance between coracoclavicular ligaments were evaluated. Clinical results and complications including stiffness and secondary procedures were evaluated. Results: Bony union was achieved in all cases except one (22 of 23). At mean 14.9 months, no significant difference in the mean coracoclavicular distance was observed compared to uninjured shoulder ($8.2{\pm}7.9mm$ versus $7.3{\pm}3.4mm$, p=0.14). Pain visual analogue scale, American Shoulder and Elbow Surgeons score, Constant score, and Disabilities of the Arm, Shoulder and Hand score were 0.5, 83.4, 78.5, and 6.2, respectively. Revision surgery was performed in one case of nonunion. Four patients who complained of skin irritation underwent implant removal. Conclusions: In cases of an unstable distal clavicle fracture with coracoclavicular ligament disruption, satisfactory clinical results were obtained by locking plate fixation and coracoclavicular ligament suture augmentation concurrently.

Ammonia Reduction from Swine Manure Slurry with Additives of Brown Coal and Oak Charcoal (양돈분뇨의 암모니아 저감을 위한 갈탄, 참숯 첨가제의 효능 분석)

  • Hwang, H.S.;Oh, I.H.;Jang, Y.S.
    • Journal of Animal Environmental Science
    • /
    • v.14 no.2
    • /
    • pp.91-96
    • /
    • 2008
  • The odours from spreading the slurry, manure storage tanks, and the stall are a source of annoyance for the neighbors and sometimes even become a case for civil appeal. Reducing the odourant and ammonia emission is an urgent need to be addressed. It is known that brown coal and oak charcoal have an ability to absorb odour. We designed an experiment set in lab scale and used the brown coal and oak charcoal as additives in the test to reduce odour. The test are divided into two categories; namely aeration and no-aeration. The additives were added to the each sample at a concentration of 5% and 10% of total base solids, besides the control samples. We carried out the Phenate Method for ammonia analyzing. In the non-aerated case, the results showed a reducing efficiency of 23.7% and 26.4% with an addition rate of 5% and 10% of additives, respectively. In the aerated test, the reducing efficiency of ammonia was 17.8% and 21.0% with an addition rate of 5% and 10% of additives, respectively. In case of oak charcoal, non-aeration showed removal efficiencies of ammonia at 15.9% and 16.1% with addition rates of 5% and 10%, respectively, With aeration, they were 11.4% and 26.4% with addition rates of 5% and 10% oak charcoal, respectively. The tests show that brown coal and oak charcoal have a reducing effect on ammonia emissions.

  • PDF

An Experimental Study for Preventing the Resonance of Steam Turbine Blade (증기터빈 블레이드의 공진 방지를 위한 실험 연구)

  • 하현천;이동진;류석주
    • Journal of KSNVE
    • /
    • v.11 no.3
    • /
    • pp.410-415
    • /
    • 2001
  • This paper describes an experimental analysis for improving the stability of blade failure due to the vibration resonance, which happens in the low-pressure steam turbine. Some cracks due to high cycle fatigue were found in the blades of a low-pressure turbine after long time operation. Impact test showed that such failure was mainly caused by the resonance. In other words, since one of the natural frequencies of the grouped blade is very close to the excitation frequency of the nozzle, the resonant vibration leads to a large amplitude of displacement and results in a large amount of stress that may cause fatigue failures in the blades. It is interesting that the blade failures occur only at blades neighboring with the nodal points of the natural vibration mode whose natural frequency is close to the nozzle passing frequency. The effective methods for increasing the reliability against the blade vibration are a heightening the fatigue limit of the blade using an advanced material and a removing the resonance away from the operating speed. It is well known that the removal of theresonance could be obtained by the installation of different types of shrouds, wires, and links between the blades as well as by the chance of the number of nozzles. In the present work, two kinds of modification for avoiding the resonance haute been considered; 1) slot-type finger, 2) long span cover. Full-scale mockup tests have been performed in order to confirm the verification for modification in the shop. Test results show that the use of long span cover is very useful to change the natural frequencies of the grouped blade and to avoid the resonance effectively.

  • PDF

Biofiltration of soil Vapor Extraction Off-gas from Gasoline Contaminated Soil Using a Compost (퇴비를 이용한 가솔린 오염토양증기추출 배가스의 바이오필터 처리)

  • 남궁완;박준석
    • Journal of Korea Soil Environment Society
    • /
    • v.4 no.3
    • /
    • pp.25-33
    • /
    • 1999
  • The recent emergence of biofiltration as a cost effective waste-gas control technology has stimulated in European countries and the USA. Biofiltration of soil vapor extraction off-gas from gasoline contaminated site was simulated in lab-scale in this study. A filling material used was a compost. This study was conducted to evaluate biofiltration characteristics of the compost material for gasoline off-gas. TPH elimination capacity at the gas loading rate of about 50g/$\textrm{m}^3$((filling material)/hr was circa 40g/$\textrm{m}^3$((filling material)/hr. Removal rate of xylene was the highest among BTEX. while it was the lowest in case of bezene. The maximum elimination capacity of the compost was about 1.5g/$\textrm{m}^3$((filling material)/hr for benzene. More than 95% of trimethylbenzene and naphtalene were removed below the loading rate of 0.7g/㎥(filling material)/hr. About 80% of total TPH and BTEX were removed by biodegradation.

  • PDF

Removal of Fine Suspended Solids and Soluble Heavy Metals in H Mine Drainage using Settling and Filtering : Field Application (침전 및 여과를 통한 H 광산배수 내 미세부유물질 및 용해성 중금속의 제거 : 현장실험을 중심으로)

  • Oh, Minah;Kim, WonKi;Oh, Seungjin;Kim, DukMin;Lee, SangHoon;Lee, Jai-Young
    • Journal of Soil and Groundwater Environment
    • /
    • v.18 no.7
    • /
    • pp.54-62
    • /
    • 2013
  • Fine suspended solids and soluble heavy metals generated from mine drainage could destroy environment as the aesthetic landscapes, and depreciate water quality. Therefore, this research is focused on process development applied the actual field for controlling fine suspended solids and heavy metals, and so that bench-scale tests were performed for field application based on advanced researches. The field of mine drainage in this research was in H mine located Taebaek-si, Gangwon-do. The inclination plates were mounted 2 kinds of arrangement (octagon and radial types) in circle type settling basin. The inclination plates could be helped to settle of suspended solids; decreased 34% of suspended solids and 50% of turbidity in effluent. Radial type of inclination plates showed the results that is more efficient to settle of suspended solids (average to 3.45 mg/L) compared to octagon type. In the experiments to decrease retention time of mine drainage in settling basin from 6 hrs to 1.5 hrs, suspended solid concentration was exceeded to 30 mg/L as the standard for suspended solid at 10 days after the operation under tha retention time of 3hrs and 1.5hrs. In the tests for filtration, granular activated carbons were indicated the better effective to filtering and absorption of fine suspended solid and soluble heavy metals than anthracite.

Removal of Dissolved Heavy Metals in Abandoned Mine Drainage by Ozone Oxidation System (오존산화를 이용한 폐광산배수 내 용존 중금속 제거에 관한 연구)

  • Seo, Suk Ho;Ahn, Kwang Ho;Lee, Jung Kyu;Kim, Gun Jooung;Chu, Kyoung Hoon;Ra, Young Hyun;Ko, Kwang Baik
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.5
    • /
    • pp.725-731
    • /
    • 2010
  • This study was to evaluate the ozone oxidation of dissolved Fe, Mn, $SO{_4}^{2-}$ ions and color in abandoned mining drainage by conducting a bench-scale operation at various reaction times in an ozone reactor. The influent was collected from an abandoned mine drainage (AMD) near the J Mine in Jungsungun, Kangwon Province. The ozone reactor was operated at ozone reaction times of 10, 20 and 30 min with ozone doses of 0.0 and $2.4g\;O_3/hr$. Samples from each effluent from subsequent sand filtration were regularly collected and analyzed for pH, Fe, Mn, Al, Cr, Hg, $SO{_4}^{2-}$, alkalinity, color, ORP, TDS and EC. The effluent concentrations of Fe and Mn from the sand filter were less than 0.1 mg/L, which were below the concentrations on Korean drinking water quality standards (Fe, Mn < 0.30 mg/L). The influent $SO{_4}^{2-}$, concentrations were not noticeably changed during this ozone oxidation. Cr and Hg in the raw wastewater from the abandoned mining drainage were not detected in this study. The experimental result shows that the ozone oxidation of dissolved heavy metals and subsequent sand filtration of metal precipitates are desirable alternative for removing heavy metals in AMD.

Advanced Wastewater Treatment using Bioreactor Combined with Alternative Membrane (하수의 고도처리를 위한 저비용 저에너지의 대체 막을 조합한 생물반응기의 개발)

  • Kim, Dong-Ha
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.1
    • /
    • pp.25-30
    • /
    • 2005
  • In order to decrease the high costs of membrane process, we have tried to develop two alternatives to membrane; a cartridge type filter and a metal membrane were tested for the high permeation flux with low cost and low energy. This research mainly focused on three points; 1) operation with high permeation flux by using of a cartridge type filter and a metal membrane, 2) removals of the filterable organic materials (FOC) by pretreatments for the membrane fouling control, and 3) advanced wastewater treatment by SMBR process with intermittent aeration and high MLSS. An Intermittently aerated membrane bioreactor using a submerged micro filter (cartridge type) was applied in laboratory scale for the advanced wastewater treatment. To minimize membrane fouling, intermittent aeration was applied inside of the filter with $3.0kg_f/cm^2$. The experiments was conducted for 6 months with three different HRTs (8, 10, 12 hr) and high MLSS of 6,000 and 10,000mg/L. The filtration process could be operated up to 50 days with permeation flux of 500LMH. Regardless of the operating conditions, more than 95% of COD, BOD and SS were removed. Fast and complete nitrification was accomplished, and denitrification was appeared to be the rate-limiting step. More than 75% T-N could be removed due to the endogenous denitrification. T-P removal efficiency was increased to 80% under the condition of MLSS 10,000mg/L.

Improvement of Pressurized MF Pretreatment in MF/RO Process for Reuse (하수방류수 재이용 MF/RO 공정에서 가압식 MF의 전처리 성능 향상 방안 연구)

  • Na, Yumee;Park, Yong-Min;Lee, Yang-Woo;Kim, Won Kyong;Kim, Ji-Tae;Cho, Il-Hyoung
    • Membrane Journal
    • /
    • v.24 no.5
    • /
    • pp.350-357
    • /
    • 2014
  • Pressurized MF membranes are used to remove suspended solid and colloidal materials of wastewater treatment plant effluent as the pretreatment of RO in reuse water production process. Membrane operation data and pollutants removal efficiency are investigated using 100 t/d scale pilot plant in J wastewater treatment plant located in Namyangju city. 40 LMH flux of pressurized MF membrane are obtained in various turbidity and temperature condition. Coagulation of dissolved organic enables flux improvement of MF from 40 LMH to 60 LMH. Pressure drop of 1st RO elements rapidly increased after long-term pause, which is because the complex contamination of organic matter and ionic substances of pluming systems.

Correlation of Releases of Nutrient Salts in Sediment with Vicinal Oxic Conditions (퇴적물의 영양염류 용출과 호기적 조건과의 상관성 분석)

  • Cho, Dae-Chul;Lee, Eun-Mi;Park, Byung-Gi;Kwon, Sung-Hyun
    • Journal of Environmental Science International
    • /
    • v.20 no.7
    • /
    • pp.845-855
    • /
    • 2011
  • The aim of this paper is to correlate the release characteristics of marine and lake sediment with their vicinal oxic conditions. We performed lab-scale simulation experiments using field sediment and water in order to compare the release concentrations and the release rates one another. To provide a few different kinds of oxic environments we used natural air flow and some oxygen releasing compounds such as $CaO_2$ and $MgO_2$. In case of phosphates, in each oxic condition, removal of phosphorus via biological activity and that via salt precipitation with the metal ions lowered the release rates. The behavior of the nitrogen-origin salts seemed to greatly depend on the typical biological actions - growth of biomass, nitrification, and partial denitrification. Generally speaking, the control of releases of $NH_3$-N, $PO_4$-P, T-N and T-P was successful under the oxic conditions meanwhile COD, nitrates and nitrites were difficult to reduce the releases into the bulk water because of the considerable microbial oxidation. Based on typical diffusive mass transfer kinetics the changes of concentrations of the nutrients were computed for qualitative and quantitative comparisons.