• Title/Summary/Keyword: scale merit

Search Result 58, Processing Time 0.024 seconds

Clinical Uses of Diffusion Tensor Imaging Fiber Tracking Merged Neuronavigation with Lesions Adjacent to Corticospinal Tract : A Retrospective Cohort Study

  • Yu, Qi;Lin, Kun;Liu, Yunhui;Li, Xinxing
    • Journal of Korean Neurosurgical Society
    • /
    • v.63 no.2
    • /
    • pp.248-260
    • /
    • 2020
  • Objective : To investigate the efficiency of diffusion tensor imaging (DTI) fiber-tracking based neuronavigation and assess its usefulness in the preoperative surgical planning, prognostic prediction, intraoperative course and outcome improvement. Methods : Seventeen patients with cerebral masses adjacent to corticospinal tract (CST) were given standard magnetic resonance imaging and DTI examination. By incorporation of DTI data, the relation between tumor and adjacent white matter tracts was reconstructed and assessed in the neuronavigation system. Distance from tumor border to CST was measured. Results : The sub-portion of CST in closest proximity to tumor was found displaced in all patients. The chief disruptive changes were classified as follows : complete interruption, partial interruption, or simple displacement. Partial interruption was evident in seven patients (41.2%) whose lesions were close to cortex. In the other 10 patients (58.8%), delineated CSTs were intact but distorted. No complete CST interruption was identified. Overall, the mean distance from resection border to CST was 6.12 mm (range, 0-21), as opposed to 8.18 mm (range, 2-21) with simple displacement and 2.33 mm (range, 0-5) with partial interruption. The clinical outcomes were analyzed in groups stratified by intervening distances (close, <5 mm; moderated, 5-10 mm; far, >10 mm). For the primary brain tumor patients, the proportion of completely resected tumors increased progressively from close to far grouping (42.9%, 50%, and 100%, respectively). Five patients out of seven (71.4%) experienced new neurologic deficits postoperatively in the close group. At meantime, motor deterioration was found in six cases in the close group. All patients in the far and moderate groups received excellent (modified Rankin Scale [mRS] score, 0-1) or good (mRS score, 2-3) rankings, but only 57.1% of patients in the close group earned good outcome scores. Conclusion : DTI fiber tracking based neuronavigation has merit in assessing the relation between lesions and adjacent white matter tracts, allowing prediction of patient outcomes based on lesion-CST distance. It has also proven beneficial in formulating surgical strategies.

A Study on Installation of Removal Device for Volatile Organic Compounds from Petrochemical Plant (석유화학 공장에서 VOCs 제거시설 설치사례 연구)

  • 김석택
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.2
    • /
    • pp.95-101
    • /
    • 2000
  • High growth of economy and industrial development was produced every air pollutants, that is, SOx, NOx, dust, VOCs and malodorous gas was produced. Recently, volatile organic compounds(VOCs) was bring about very serious environmental problems. Ulsan petrochemical complex was densely a large scale of petrochemical plant. This study was carried out to select treatment equipment of VOCs produced from petrochemical plant, and has compared with Carbon filter, Regenerative thermal oxidation(RCO) and Flare stack for technical merit and demerit but also initial investment and operating cost.

  • PDF

Development and Characterization of High Temperature Filter (내열성여과포의 개발 및 기초성능 규명)

  • 박영옥;구철오;임정환;김홍룡;손재익;이영우
    • Journal of Energy Engineering
    • /
    • v.7 no.1
    • /
    • pp.103-112
    • /
    • 1998
  • A high temperature fabric filter was developed and characterized in order to solve the various problems encountered in the operation of industrial fabric filters. Four kinds of dusts generated in the typical domestic industry were used for its characterization, coke dust from a steel manufacturing process, cement dust from a cement manufacturing process, fly ash from a fluidized-bed combustor, and incinerator ash from a waste plastics incinerator. The physical and chemical properties of the high temperature fabric filter were analyzed in terms of mean flow pore pressure, bubble point pore diameter, mean flow pore diameter, pore size distribution, and the changes in tensile strength and initial elastic modulus under $SO_2$ and $NO_2$ atmospheres. Pressure drop, dust penetration, and figure of merit for the fabric filter were also investigated in a bench-scale filter testing unit. The fabric filter developed in this study had good physical and chemical filter properties and showed a very applicability to typical industrial dusts treatments.

  • PDF

Effect of plate properties on shear strength of bolt group in single plate connection

  • Ashakul, Aphinat;Khampa, Kriangkrai
    • Steel and Composite Structures
    • /
    • v.16 no.6
    • /
    • pp.611-637
    • /
    • 2014
  • A single plate shear connection, or shear tab, is a very popular shear connection due to its merit in ease of construction and material economy. However, problems in understanding the connection behavior, both in terms of strength and ductility, have been well-documented. Suggestions or design model for single plate connections in AISC Design Manual have been altered several times, with the latest edition settling down to giving designers pre-calculated design strength tables if the connection details agree with given configurations. Results from many full-scale tests and finite element models in the past suggest that shear strength of a bolt group in single plate shear connections might be affected by yield strength of plate material; therefore, this research was aimed to investigate and clarify effects of plate yield strength and thickness on shear strength of the bolt group in the connections, including the validity of using a plate thickness/bolt diameter ratio ($t_p/d_b$) in design, by using finite element models. More than 20 models have been created by using ABAQUS program with 19.0- and 22.2-mm A325N bolts and A36 and Gr.50 plates with various thicknesses. Results demonstrated that increase of plate thickness or plate yield strength, with the $t_p/d_b$ ratio remained intact, could significantly reduce shear strength of the bolt group in the connection as much as 15 percent. Results also confirmed that the $t_p/d_b$ ratio is a valid indicator to be used for guaranteeing strength sufficiency. Because the actual ratio recommended by AISC Design Manual is $t_p/d_b$ + 1.6 (mm) for connections with a number of bolts less than six and plate yield strength in construction is normally higher than the nominal value used in design, it is proposed that shear strength of a bolt group in single plate connections with a number of bolts equal or greater than seven be reduced by 15 percent and the $t_p/d_b$ ratio be limited to 0.500.

(2, 2) Secret Sharing Using Data Hiding and Multiplexer Technique (데이터 은닉과 멀티플렉서 기법을 이용한 (2, 2) 비밀 공유방법)

  • Kim, Cheonshik
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.13 no.4
    • /
    • pp.75-81
    • /
    • 2013
  • We presents a novel (2, 2) secret sharing (SS) scheme for all grayscale images. Generally, a secret image is distribute more than two shadow images, which are dealt out among participants. In order to find out secret image, participants print shadow images to transparent papers. Then, a secret image will appear as stacking transparent papers. The secret sharing scheme in this paper distribute secret image into natural grayscale images using multiplexer and data hiding scheme. After then, two participant have two shadow images respectively. The merit of the proposed scheme is that shadow images have small loss in aspect of the quality with steganographic features. Therefore, the proposed secret sharing scheme in this paper is not easily detected by attackers. The experiment result verified that the proposed scheme, obviously outperforms previous SS schemes.

Membrane Processes for Energy Saving in Japan

  • Nakao, Shin-ichi
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1994.06a
    • /
    • pp.45-58
    • /
    • 1994
  • Over the last 20 years, membrane separation processes, such as reverse osmosis, ultrafiltration and microfiltration, have been widely adopted by different industries. Commercial uses of membrane have displaced conventional separation processes, such as distillation, evaporation, precoat filter and so on. Membrane separation processes are often more capital and energy efficient when compared with conventional separation processes. Membrane devices and systems are almost always compact and modular. These are the well-known advantages of membrane separation processes. The disadvantage of the membrane process is that the process does not have scale merit and thus the membrane process is suitable for the small and middle size applications. Energy saving is, of course, the biggest advantage of the membrane process, and in many industries the membrane processes are employed because of this reason. Membrane process has other big advantage. In many applications membrane processes provide much higher quality of product than conventional processes. The example is ultrapure water production by membrane processes in semiconductor industry. Conventional technologies never offer such good quality of pure water. If you can obtain both energy saving and higher quality of product at the same time by membrane processes, this is the best application of membrane processes. One example is the concentration of orange juice by membrane, which has already been commercialized in Japan. Comparing with the conventional vacuum evaporation process, juice concentrated by the membrane process has much better taste and flavor and the energy consumption in the membrane process is much less than the evaporation process. In this paper, first membrane separation technology will be classified and then Japanese membrane manufacturers and new modules and devices under development in Japan will be introduced. Fourth energy saving in membrane process will be discussed and finally practical applications of membrane processes in Japan will be shown.

  • PDF

Spatial Estimation of soil roughness and moisture from Sentinel-1 backscatter over Yanco sites: Artificial Neural Network, and Fractal

  • Lee, Ju Hyoung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.125-125
    • /
    • 2020
  • European Space Agency's Sentinel-1 has an improved spatial and temporal resolution, as compared to previous satellite data such as Envisat Advanced SAR (ASAR) or Advanced Scatterometer (ASCAT). Thus, the assumption used for low-resolution retrieval algorithms used by ENVISAT ASAR or ASCAT is not applicable to Sentinel-1, because a higher degree of land surface heterogeneity should be considered for retrieval. The assumption of homogeneity over land surface is not valid any more. In this study, considering that soil roughness is one of the key parameters sensitive to soil moisture retrievals, various approaches are discussed. First, soil roughness is spatially inverted from Sentinel-1 backscattering over Yanco sites in Australia. Based upon this, Artificial Neural Networks data (feedforward multiplayer perception, MLP, Levenberg-Marquadt algorithm) are compared with Fractal approach (brownian fractal, Hurst exponent of 0.5). When using ANNs, training data are achieved from theoretical forward scattering models, Integral Equation Model (IEM). and Sentinel-1 measurements. The network is trained by 20 neurons and one hidden layer, and one input layer. On the other hand, fractal surface roughness is generated by fitting 1D power spectrum model with roughness spectra. Fractal roughness profile is produced by a stochastic process describing probability between two points, and Hurst exponent, as well as rms heights (a standard deviation of surface height). Main interest of this study is to estimate a spatial variability of roughness without the need of local measurements. This non-local approach is significant, because we operationally have to be independent from local stations, due to its few spatial coverage at the global level. More fundamentally, SAR roughness is much different from local measurements, Remote sensing data are influenced by incidence angle, large scale topography, or a mixing regime of sensors, although probe deployed in the field indicate point data. Finally, demerit and merit of these approaches will be discussed.

  • PDF

Image Quality and Lesion Detectability of Lower-Dose Abdominopelvic CT Obtained Using Deep Learning Image Reconstruction

  • June Park;Jaeseung Shin;In Kyung Min;Heejin Bae;Yeo-Eun Kim;Yong Eun Chung
    • Korean Journal of Radiology
    • /
    • v.23 no.4
    • /
    • pp.402-412
    • /
    • 2022
  • Objective: To evaluate the image quality and lesion detectability of lower-dose CT (LDCT) of the abdomen and pelvis obtained using a deep learning image reconstruction (DLIR) algorithm compared with those of standard-dose CT (SDCT) images. Materials and Methods: This retrospective study included 123 patients (mean age ± standard deviation, 63 ± 11 years; male:female, 70:53) who underwent contrast-enhanced abdominopelvic LDCT between May and August 2020 and had prior SDCT obtained using the same CT scanner within a year. LDCT images were reconstructed with hybrid iterative reconstruction (h-IR) and DLIR at medium and high strengths (DLIR-M and DLIR-H), while SDCT images were reconstructed with h-IR. For quantitative image quality analysis, image noise, signal-to-noise ratio, and contrast-to-noise ratio were measured in the liver, muscle, and aorta. Among the three different LDCT reconstruction algorithms, the one showing the smallest difference in quantitative parameters from those of SDCT images was selected for qualitative image quality analysis and lesion detectability evaluation. For qualitative analysis, overall image quality, image noise, image sharpness, image texture, and lesion conspicuity were graded using a 5-point scale by two radiologists. Observer performance in focal liver lesion detection was evaluated by comparing the jackknife free-response receiver operating characteristic figures-of-merit (FOM). Results: LDCT (35.1% dose reduction compared with SDCT) images obtained using DLIR-M showed similar quantitative measures to those of SDCT with h-IR images. All qualitative parameters of LDCT with DLIR-M images but image texture were similar to or significantly better than those of SDCT with h-IR images. The lesion detectability on LDCT with DLIR-M images was not significantly different from that of SDCT with h-IR images (reader-averaged FOM, 0.887 vs. 0.874, respectively; p = 0.581). Conclusion: Overall image quality and detectability of focal liver lesions is preserved in contrast-enhanced abdominopelvic LDCT obtained with DLIR-M relative to those in SDCT with h-IR.

Usefulness of Treatment with 6.5 mm Cancellous Screw and Steinmann Pin Fixation for Calcaneal Joint Depression Fracture (종골의 관절 함몰 골절에서 6.5 mm 해면골 나사와 Steinmann 핀을 이용한 치료의 유용성)

  • Lee, Gi-Soo;Kang, Chan;Hwang, Deuk-Soo;Noh, Chang-Kyun;Lee, Gi-Young
    • Journal of Korean Foot and Ankle Society
    • /
    • v.19 no.1
    • /
    • pp.11-17
    • /
    • 2015
  • Purpose: To report the radiographic and clinical results of 6.5 mm cancellous full threaded buttress screw or Steinmann pin fixation to maintain a reduction of calcaneal posterior facet depression fracture. Materials and Methods: From June 2009 to June 2012, 50 consecutive cases with calcaneal joint depression fracture that underwent open reduction and screw or pin fixation were enrolled in this study. A 6.5 mm cancellous full threaded screw was inserted from the posteroinferior aspect of the calcaneal tuberosity to the posterior facet (group A) or Steinman pin was inserted from the posterosuperior aspect of the calcaneal tuberosity to the calcaneocuboidal joint (group B). Both preoperative and postoperative Bohler and Gissane angles were measured radiographically, and American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot scale on the final follow-up were assessed. Results: The mean age of patients was 44.1 years, and the mean follow-up period was 27.2 months. According to the Sanders classification, 28 cases were type II and 22 cases were type III. In Sanders type II, Bohler and Gissane angles improved significantly from $10.1^{\circ}$ and $126.2^{\circ}$ preoperatively to $27.2^{\circ}$ and $117.1^{\circ}$, respectively, in the immediate postoperative radiograph, and at the final follow-up, $26.6^{\circ}$ and $118.6^{\circ}$, respectively. In Sanders type III, Bohler and Gissane angles improved significantly from $5.0^{\circ}$ and $129.8^{\circ}$ to $29.9^{\circ}$ and $119.3^{\circ}$, respectively, in the immediate postoperative radiograph, and $26.9^{\circ}$ and $120.2^{\circ}$ at the final follow-up. All cases achieved bony union, and the average period until complete union was 13.3 weeks. AOFAS ankle-hindfoot scale was 82.6 in Sanders type II and 77.3 in Sanders type III at the final follow-up. Conclusion: A 6.5 mm cancellous full threaded buttress screw or Steinman pin fixation is a noninvasive treatment method with a merit of being able to maintain the bearing capacity of the posterior facet comparable to plate fixation.

Barriers to University Librarians' Research Utilization (대학도서관 사서의 연구활용 장애)

  • Lee, Eun-Chul;Kim, Kap-Seon
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.38 no.1
    • /
    • pp.77-91
    • /
    • 2004
  • The present study surveyed university librarians' perceptions of barriers to research utilization using the Barrier Scales. The results shows that in mean Barriers Scale scores, characteristics of the organization had the highest, and then followed by the communication, the research and the librarian. The most important factor was perceived to be organizational support relating to insufficient time to implement new ideas, inadequate facilities, and lack of authority to make changes and in the communication relating to lack of clarity of research implications for practice, lack to demonstrate research's relevance to practice, and lack of readability of research. Also, incomprehensible English research reports and statistical analyses were perceived as major barriers. The comparison with those of nursing was discussed. In order to settle the barriers identified, librarians should be educated to have 'research literacy' and organazational merit and reward systems were reinforced for research utilization. Also, it needs to explore librarians' specific experiences of barriers in utilizing process in practice. In further research, by integrating both the result of the quantitative and qualitative research, it needs to develop and to assess a standard measurement for librarians' barriers of research utilization in national and international context.