• Title/Summary/Keyword: saturation coefficient

Search Result 249, Processing Time 0.024 seconds

Analysis of Relationship between Mixed Venous PO2 and Status of Cardiac Performance with Hemodynamic Values after Correction of Cyanotic Congenital Heart Disease (청색심기형 교정술후 혼합정맥혈 산소분압과 심근상태 및 혈류역학치와의 상관관계 분석)

  • An, Jae-Ho;Kim, Yong-Jin
    • Journal of Chest Surgery
    • /
    • v.22 no.2
    • /
    • pp.212-219
    • /
    • 1989
  • We utilized pulmonary artery pressure monitoring system in risky patients for preventing the postoperative pulmonary hypertensive crisis and for sampling the mixed venous blood. And this mixed venous blood oxygen saturation [MVSO2] or partial pressure [MVPO2]tells us many meaningful patients state. We selected 59 cyanotic congenital heart diseased patients, who were operated in our hospital from Nov. 1987 to Oct. 1988, in the Department of Thoracic and Cardiovascular Surgery, Seoul National University Children\ulcorner Hospital, who had pulmonary artery pressure monitoring catheter and who made us know their mixed venous oxygen condition. We found that there was no close relationship between MVPO2 and Cardiac Index [C.I.] during early postoperative period, but on the first and second day after operation the correlation coefficient was increased as r=0.35[p=0.008], r=0.78[p=0.0001]. So we concluded that the correlation between MVPO2 and C.I. was more reliable with time going as hemodynamic stabilization. And we experienced no survivors whose MVPO2 was under 20 torr, but that was not the only factor for death. From these results, we conclude that we can consider the MVPO2 [or MVSO2] representing C.I. after stabilized postoperative condition of the open heart surgery patients, but during early postoperative period, in addition to this MVPO2, we should do also apply other parameter such as urine output, arterial blood pressure, left atrial pressure and pulmonary arterial pressure for exact estimation of the patients status.

  • PDF

Studies on the Development of Bearing Capacity Reinforcement for the Foundation of Soil (기초지반의 지지력보강공법에 관한 연구)

  • 유동환;최예환;유연택
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.30 no.1
    • /
    • pp.38-49
    • /
    • 1988
  • This paper presented as follows results of laboratory model tests with various shaped footings on soil bed reinforced with the strips on the base of behaviour of soil structure according to the loads and triaxial test results reinforced with geotextiles. Their parameters studied were the effects on the bearing capacity of a footing of the first layer of reinforcement, horizontal and vertical spacing of layers, number of layers, tensile strength of reinforcement and iclination load to the vertical 1.Depending on the strip arrangement, ultimate bearing capacity values could be more improved than urreinforced soil and the failure of soil was that the soil structure was transfered from the macrospace to microspase and its arrangement, from edge to edge to face to face. 2.The reinforcement was produced the reinforcing effects due to controlling the value of factor of one and permeable reinforcement was never a barrier of drainage condition. 3.Strength ratio was decreased as a linear shape according to increment of saturation degree of soil used even though at the lower strength ratio, the value of M-factor was rot influenced on the strength ratio but impermeable reinforcement decreased the strength of bearing capacity. 4.Ultimate bearing capacity under the plane-strain condition was appeared a little larger than triaxial or the other theoretical formulars and the circular footing more effective. 5.The maximum reinforcing effects were obtained at U I B=o.5, B / B=3 and N=3, when over that limit only acting as a anchor, and same strength of fabric appeared larger reinforcing effects compared to the thinner one. 6.As the LDR increased, more and more BCR occurred and there was appeared a block action below Z / B=O.5, but over the value, decrement of BCR was shown linear relation, and no effects above one. 7.The coefficient of the inclination was shown of minimum at the three layers of fabrics, but the value of H / B related to the ultimate load was decreased as increment of inclination degree, even though over the value of 4.5 there wasn't expected to the reinforcing effects As a consequence of the effects on load inclination, the degree of inclination of 15 per cent was decreased the bearing capacity of 70 per cent but irnproved the effects of 45 per cent through the insertion of geotextile.

  • PDF

Estimation of Moisture Diffusivity during Absorption by Boltzmann Transformation Method (Boltzmann법에 의한 목재 흡수시 확산계수 추정)

  • Kang, Wook;Chung, Woo Yang
    • Journal of the Korean Wood Science and Technology
    • /
    • v.37 no.1
    • /
    • pp.1-11
    • /
    • 2009
  • Although the exterior wood such as column may frequently contact with liquid water, little work has been found to measure liquid water absorption in wood. To investigate the moisture diffusivity of wood in the longitudinal direction including bound water and free water movement, liquid water absorption test was conducted at the room temperature. The order of magnitude for absorption coefficient and diffusivity was Japanese elm, horn beam, hemlock, spruce, radiata pine, and painted maple. The Boltzmann transformation method was used to determine the diffusivity from measured moisture content distributions in the absorption test. The shape of the curve representing the dependence of diffusivity with moisture content was similar in test samples. The diffusivity decreased with increasing moisture content until around the fiber saturation point and then increased at the nonhygroscopic region, which ranged from $10^{-10}$ to $10^{-7}m^2/s$.

A Study on Evaluation for the Han River Water Quality Index (한강의 수질지수 산정에 관한 연구)

  • 서정현
    • Water for future
    • /
    • v.14 no.3
    • /
    • pp.55-66
    • /
    • 1981
  • The theory and practice of water quality scoring and indexing are introduced. The monthly water analysis data are available for six stations long the down-stream Han River whthin the areal boundary of the Special City of Seoul. The data cover the period between 1975 and 1979 inclusive and contain the analytical findings on 37 water constituents including DO, BOD, temperature, total solids and etc. Sic parameters are selected form the 37 items, that, to the judgement of the writer, best reflect the water quality of the Han River. They are; dissolved oxggen saturation, pH, fecal coliform, total solids, BOD and nitrate+ammonia. For each of the six parameters, a subscore function is developed and graphically presented to facilitate the transform of a measurment of the arameter to a subscore on a common score(e.G. 0-100) The score of a sample is calculated as a fuction of the six subscores, using four different approaches; (1) the unweighted arithmetic water quality score, (2) the weighted arithmetic water quality score, (3)the unweighted multiplicative score and (4) the reduced (total) score. Independent of these calculated scores, the experts' score which is calculated by averaging the ratings of water quality experts is obtained and compared with each of the four calculated scores by means of the least square method. The experts' score compares most favorably with the "reduced" score with the correlation coefficient of 0.956 : therefore this method of water quality scoring is adopted to calculate the Han River water quality scores and indices. Water quality index data for Guiri, ukdo, Pokwangdong, Noryangjin, Yongdungpo and Kayang Stations, 1975-1979 are as follow: The overall water quality index data of the Han River between Guiri and Kayang Stations are found; 47.3 in 1976, 48.0 in 1977, 48.5 in 1978 and 54.7 in 1979, indicating the general trend towards water quality improvent in this part of the river, in terms of the increased water quality index by average 1.85 points per year during this period. Finally the optimum sampling frequencies distributed among the six stations, using an equation which takes into account the coefficients of variation of the water quality scores and indices arec calculated.alculated.

  • PDF

A Study on the Condensation Heat Transfer and Pressure Drop in Internally Grooved Tubes Used in Condenser (응축기용 낮은 핀관의 내부 나선 홈에 의한 응축 열전달 성능과 압력손실에 관한 연구)

  • Han, Kyuil;Cho, Dong-Hyun
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.34 no.2
    • /
    • pp.212-222
    • /
    • 1998
  • Heat transfer performance improvement by fin and groovs is studied for condensation of R-11 on integral-fin tubes. Eight tubes with trapczodially shaped integral-fins having fin density from 748 to 1654fpm(fin per meter) and 10, 30 grooves are tested. A plain tube having the same diameter as the finned tubes is also used for comparison. R-11 condensates at saturation state of 32 $^{\circ}C$ on the outside tube surface coded by inside water flow. All of test data are taken at steady state. The heat transfer loop is used for testing singe long tubes and cooling is pumped from a storage tank through filters and folwmeters to the horizontal test section where it is heated by steam condensing on the outside of the tubes. The pressure drop across the test section is measured by menas pressure gauge and manometer. The results obtained in this study is as follows : 1. Based on inside diameter and nominal inside area, overall heat transfer coefficients of finned tube are enhanced up to 1.6 ~ 3.7 times that of a plain tube at a constant Reynolds number. 2. Friction factors are up to 1.6 ~ 2.1 times those of plain tubes. 3. The constant pumping power ratio for the low integral-fin tubes increase directly with the effective area to the nominal area ratio, and with the effective area diameter ratio. 4. A tube having a fin density of 1299fpm and 30 grooves has the best heat transfer performance.

  • PDF

The heat transfer characteristics of a desorber for 150 RT absorption heat pump (150 RT급 흡수식 열펌프용 고온재생기의 열전달 특성)

  • 박찬우;정종수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.3
    • /
    • pp.369-376
    • /
    • 1999
  • Experiments were carried out to study the heat transfer characteristics of a disrober for 150 RT LiBr-water absorption heat pump. An experimental apparatus was divided into four sections, a combustion chamber area, two bare-tube areas, and finally a finned-tube area to quantify the heat transfer rate of each section by measuring the generation rate of vapor. Dividing plates was installed at the upper inside part of deserter to prohibit the moving of vapor generated at heating tubes of a section to another section near. In the first bare-tube area, the generation rate of vapor was the largest among the four sections. The finned-tube area only contributed to give sensible heat increase of solution to the saturation temperature. The heat transfer area of the finned-tube area was 52.2%, which absorbed only 9.2% of the total heat from the combustion gas. On the contrary, the heat transfer area of the first bare-tube area was 16.6%, but it absorbed 52.4% of the total absorbed heat. The temperature of the solution at upper part at the finned-tube area was lower than that of the lower part, because weak solution came in upper part of the finned-tube area. But, this tendency was changed at the first and second bare-tube area due to the vigorous heat transfer and fluid flow enhanced by vapor generation through heating tubes. The overall heat transfer coefficient and heat flux were the largest at the first bare-tube area among the other sections.

  • PDF

Performance of R290 and R1270 as Alternative Refrigerants of R22 According to Temperature Variations of Evaporator and Condenser (증발기와 응축기 온도변화에 따른 R22 대체냉매 R290 및 R1270의 성능평가)

  • Baek In-Cheol;Park Ki-Jung;Shim Yun-Bo;Jung Dong-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.10
    • /
    • pp.761-767
    • /
    • 2006
  • In this study, performance of 2 pure hydrocarbons R290 and R1270 was measured in an attempt to substitute R22 under 3 different temperature conditions. They were tested in a refrigerating bench tester with a hermetic rotary compressor. The test bench provided about 3.5 kW capacity and water and water/glycol mixture were employed as the secondary heat transfer fluids. All tests were conducted under the same external conditions resulting in the average saturation temperatures of $7/45^{\circ}C$ and $-7/41^{\circ}C$ and $-21/28^{\circ}C$ in the evaporator and condenser, respectively. Test results show that the coefficient of performance (COP) of these refrigerants is up to 11.54% higher than that of R22 in all temperature conditions. Compressor discharge temperatures were reduced by $14{\sim}31^{\circ}C$ with these fluids. There was no problem with mineral oil since the mixtures were mainly composed of hydrocarbons. The amount of charge was reduced up to 58% as compared to R22. Overall, these fluids provide good performance with reasonable energy savings without any environmental problem and thus can be used as long term alternatives for residential air-conditioning and heat pumping application.

Performance Evaluation of R22 Alternative Refrigerants According to Temperature Variations of Evaporator and Condenser (증발기와 응축기 온도변화에 따른 R22 대체냉매의 성능평가)

  • Baek, In-Cheol;Shim, Yun-Bo;Jung, Dong-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.58-63
    • /
    • 2006
  • In this study, performance of 2 pure hydrocarbons and 3 mixtures was measured in an attempt to substitute R22 under 3 different temperature conditions. The mixtures were composed of R1270(propylene), R290(propane) and R152a. They were tested in a refrigerating bench tester with a hermetic rotary compressor The test bench provided about 3.5 kW capacity and water and water/glycol mixture were employed as the secondary heat transfer fluids. All tests were conducted under the same external conditions resulting in the average saturation temperatures of $7^{\circ}C/45^{\circ}C$ and $-7^{\circ}C/41^{\circ}C$ and $-21^{\circ}C/28^{\circ}C$ in the evaporator and condenser, respectively. Test results show that the coefficient of performance (COP) of these refrigerants is up to 11.54% higher than that of R22 in all temperature conditions. Compressor discharge temperatures were reduced by $14{\sim}31^{\circ}C$ with these fluids. There was no problem with mineral oil since the mixtures were mainly composed of hydrocarbons. The amount of charge was reduced up to 58% as compared to R22. Overall, these fluids provide good performance with reasonable energy savings without any environmental problem and thus can be used as long term alternatives for residential air-conditioning and heat pumping application.

  • PDF

Water Holding Capacity and Hydraulic Conductivity According to Compaction and Saturation Degree for Perlite amended with Ground Coir (압밀과 포화수준에 따른 분쇄 Coir 혼합 펄라이트의 수분보유력과 수리전도도)

  • Kim, Gi-Rim;Woo, Hyun-Nyung;Kim, Hye-Jin;Park, Mi-Suk;Song, Jin-A;Song, Tae-Yong;Jang, Hyo-Ju;Chung, Doug-Young
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.6
    • /
    • pp.998-1003
    • /
    • 2011
  • This investigation was performed to determine the hydraulic conductivity coefficient and water holding capacity for a specified compaction forces which are the amount of mechanical energy applied to the porous granule (PG) volume. Most current specifications of minerals and perlite as growth media require to be compacted to a specified density, which in general is equivalent to a certain percentage of laboratory compaction. The water holding capacity of the saturated PG was very large at potential above -1 bar compared with perlite, but very little water remained below this value. The water holding capacity and hydraulic conductivity characteristics of graded PG amended with the ground coir less than 2 mm in diameter were also determined from pressure outflow data. The saturated hydraulic conductivity of the saturated and compacted PG was slightly lower by more than one tenth order of magnitude at equal matric potentials of perlite, but when expressed on the basis of equal water deficits, the conductivity of PG was higher at all but the smallest deficits than those of perlite.

Predictive Model of Optimal Continuous Positive Airway Pressure for Obstructive Sleep Apnea Patients with Obesity by Using Machine Learning (비만 폐쇄수면무호흡 환자에서 기계학습을 통한 적정양압 예측모형)

  • Kim, Seung Soo;Yang, Kwang Ik
    • Journal of Sleep Medicine
    • /
    • v.15 no.2
    • /
    • pp.48-54
    • /
    • 2018
  • Objectives: The aim of this study was to develop a predicting model for the optimal continuous positive airway pressure (CPAP) for obstructive sleep apnea (OSA) patient with obesity by using a machine learning. Methods: We retrospectively investigated the medical records of 162 OSA patients who had obesity [body mass index (BMI) ≥ 25] and undertaken successful CPAP titration study. We divided the data to a training set (90%) and a test set (10%), randomly. We made a random forest model and a least absolute shrinkage and selection operator (lasso) regression model to predict the optimal pressure by using the training set, and then applied our models and previous reported equations to the test set. To compare the fitness of each models, we used a correlation coefficient (CC) and a mean absolute error (MAE). Results: The random forest model showed the best performance {CC 0.78 [95% confidence interval (CI) 0.43-0.93], MAE 1.20}. The lasso regression model also showed the improved result [CC 0.78 (95% CI 0.42-0.93), MAE 1.26] compared to the Hoffstein equation [CC 0.68 (95% CI 0.23-0.89), MAE 1.34] and the Choi's equation [CC 0.72 (95% CI 0.30-0.90), MAE 1.40]. Conclusions: Our random forest model and lasso model ($26.213+0.084{\times}BMI+0.004{\times}$apnea-hypopnea index+$0.004{\times}oxygen$ desaturation index-$0.215{\times}mean$ oxygen saturation) showed the improved performance compared to the previous reported equations. The further study for other subgroup or phenotype of OSA is required.