• Title/Summary/Keyword: saturation area

Search Result 404, Processing Time 0.026 seconds

Surface Saturation Area-Subsurface Outflow-Soil Moisture Storage Relationships: II. Dynamic Analysis (지표포화지역-중간류유출-흙수분저류량 관계: II. 동적 분석)

  • 이도훈;이은태
    • Water for future
    • /
    • v.29 no.2
    • /
    • pp.143-151
    • /
    • 1996
  • The dynamic responses in the subsurface outflow, surface saturation area, soil moisture storage are established by numerical experiments with Richards equation. In addition to this, the dynamical relationship between surface saturation area and subsurface outflow, and between surface saturation area and soil moisture storage are also determined by varying the hillslope shape, soil type, and boundary condition. The simulation results indicate that the dynamical relationships between surface saturation area and subsurface outflow, and between surface saturation area and soil moisture storage are approximated by the steadystate relationships. And the dynamic responses of subsurface outflow and surface saturation area are characterized by the double peaks although the rainfall pattern is asimple pulse input. As a result of numerical simulation, the physical mechanism for the occurrence of the double peaks is explained using the concept of variable source area.

  • PDF

Surface Saturation Area-Subsurface Outflow-Soil Moisture Storage Relationships: I. Steady-State Analysis (지표포화지역-중간류유출-흙수분저류량 관계: I. 정상류 분석)

  • 이도훈;이은태
    • Water for future
    • /
    • v.28 no.5
    • /
    • pp.129-140
    • /
    • 1995
  • In this study we derived steady-state relationships between surface saturation area and subsurface outflow, and between surface saturation area and soil moisture storage through numerical experiments with Richards equation on a hillslope. Numerical experiments analyzed the sensitivity of topographic and soil hydraulic properties on steady-state relationships between surface saturation area and subsurface outflow. And the power law for the extent of surface saturation area was determined as a function of subsurface outflow or soil moisture storage.

  • PDF

Color Saturation Improvement through the Use of Unequal-Area Color Filters for the RGB-LED-Backlight RGBW LCD

  • Wen, Senfar
    • Journal of Information Display
    • /
    • v.10 no.4
    • /
    • pp.164-170
    • /
    • 2009
  • The dependences of color gamut size and power consumption on the area ratio of the neutral and green subpixels for the RGB-LED-backlight RGBW LCD were studied, in which the red- and blue-subpixel areas are the same and represent one-quarter of the pixel aperture area. It was found that the color saturation of the RGBW LCD can be improved through the use of a smaller neutral- and green-subpixel area ratio, at the expense of higher power consumption.

Analysis for Electrical Fire Possibility Using Fuzzy Logic with Input Variables of Overcurrent and Saturation Time in the Indoor Wiring (전기배선에서 과전류와 포화시간을 입력변수로 갖는 퍼지기반 전기화재가능성 분석)

  • Kim, Eun-Jin;Kim, Doo-Hyun;Kim, Sung-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.6
    • /
    • pp.34-39
    • /
    • 2015
  • The study is aimed to develop fuzzy logic system that has overcurrent and saturation time as input variable and possibility of electrical fire as output variable by making bad conductor area with physical damage to indoor wiring. Most previous studies focused on thermal characteristics depending on the current size and no study considered the current size and saturation time at the same time. Therefore, the paper made into account current value and saturation time together. To this end, it created bad conductor area half the size of IV conductor (1.6 mm) on purpose and transmit electrical current from 10A to 60A by unit of 2A to find out the thermal characteristics and saturation time for current. Based on the data that came out, the study applied fuzzy logic and established the current and saturation time as input variable and chance of fire as output variable. As a result, the center of area of the system that depended only on the existing current value was 75 while the system that applied both current and saturation time presented the chance of fire at 92. It is found that the chance of bad conductor area and deteriorated insulation of electrical wire had current and saturation time as important variables. The data can be used as basic data like deteriorated wire insulation or operation features of circuit breaker in investigating the cause of electrical fire.

Color Saturation Improvement by the Use of Unequal-Area Color Filters for the RGBW LCD with RGB LED Backlit

  • Wen, Senfar
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.1073-1076
    • /
    • 2009
  • The dependences of color gamut size and power consumption on the area ratio of neutral and green sub-pixels for the RGBW LCD with RGB LED backlit are studied, in which the areas of red and blue sub-pixels are the same and are one quarter of pixel apertu re area. It is found that high color saturation and power saving can be achieved for the proposed RGBW LCD.

  • PDF

Improvement of The Saturation Voltage Characteristics of BJT Using Folded Back Electrode (Folded Back Electrode를 이용한 BJT의 포화전압특성 개선)

  • 김현식;손원소;최시영
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.5
    • /
    • pp.15-21
    • /
    • 2004
  • In this paper a new structure of BJT is proposed to improve the saturation voltage characteristics so that it can be used to the low power switching devices. In the case of the conventional finger transistor(FT), the saturation voltage is so high that it dose not satisfy the requirements for the low power device. So the other multi base island transistor(MBIT) is suggested and its saturation voltage is so low in the region of low current that it satisfy the requirement for the low power switching devices, but in region of the high current the saturation voltage tends to increase so that it does not satisfy the requirements for the low power switching devices. So in this paper a new structure of folded back electrode transistor(FBET) is proposed and the characteristics is investigated. When the new structure is applied the emitter area is increased by 35 % so the saturation voltage is reduced by 30 % at the low current region and the contact area is increased by 92 % so the saturation voltage is reduced by totally f % at the high current region with the reduction of 30 % by the increase of the emitter area and the reduction of 7 % by the increase of the emitter contact area.

IEEE 802.15.6 Under Saturation: Some Problems to Be Expected

  • Rashwand, Saeed;Misic, Jelena;Khazaei, Hamzeh
    • Journal of Communications and Networks
    • /
    • v.13 no.2
    • /
    • pp.142-148
    • /
    • 2011
  • Because currently available wireless technologies are not appropriate for wireless body area networks (WBANs), the IEEE 802.15.6 standard was introduced by the IEEE 802.15.6 Task Group to satisfy all the requirements for a monitoring system that operates on, in, or around the human body. In this work, we develop an analytical model for evaluating the performance of an IEEE 802.15.6-based WBAN under saturation condition and a noisy channel. We employ a three-dimensional Markov chain to model the backoff procedure as specified in the standard. Probability generating functions (PGFs) are used to compute the performance descriptors of the network. The results obtained from the analytical model are validated by simulation results. Our results indicate that under saturation condition, the medium is accessed by the highest user priority nodes at the vast majority of time while the other nodes are starving.

A Computational Method to Consider the Saturation of Magnetic Field In a High Density Recording Head

  • Park, Gwan-Soo
    • Journal of Magnetics
    • /
    • v.8 no.4
    • /
    • pp.164-168
    • /
    • 2003
  • In high density recording system, the recording head field on a medium should be focused in small bit area and should have a sufficient value to overcome the medium coercivity, which resulted in head saturation. In this paper, an efficient method to access the head field and field gradient considering head saturation is presented. The magnetic vector potential on the head surface is pre-calculated considering head saturation in several cases and accumulated into database. The head field on the recording media is easily produced solving Laplace equation using accessed magnetic vector potential boundaries. The computed head field is compared with a quantified magnetic force microscopy measurement.

Water Consumption of Twisted Sweet Pepper in Greenhouse (온실에서의 꽈리고추 소비수량)

  • 윤용철;이근후;서원명
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 1998.10a
    • /
    • pp.217-223
    • /
    • 1998
  • This study was performed to figure out water consumption of the twisted sweet pepper in a greenhouse. Obtained results are as follows; 1. The ambient temperature was nearly same as the normal year, while the average air temperature and the relative humidity in the green house were little bit higher than those of the outside condition. The transparency of the greenhouse roof was approximately 50%. The total amount of rainfall during the irrigation period was 1,040㎜ which is 350㎜ higher than 1997 during the same period. 2. In case of pot cultivation, as the saturation ratio was increased, the aeaf area and plant height and yield were also increased. The yield from the field cultivation was higher than the average yield from the pot cultivations which are treated by three levels of saturation ratio. 3. The variation of daily consumptive use of the twisted sweet pepper was very large in it's range. In case of the pot cultivation, as the saturation was increased, the daily and the total consumptive use were increased. 4. The daily consumptive use was strongly correlated with the ambient temperature, while it was weakly correlated with the relative humidity and solar radiation. 5. There were close correlation between plant environment; leaf area, plant height and yield, and consumptive use. As the saturation ratio was increased, the correlation between those plant factors and consumptive use was getting stronger.

  • PDF

Analysis of Saturation Flow Rate on Interrupted Flow During Rainfall (강우시 단속류 포화교통류율 변화 분석)

  • Kim, Bongseok;Roh, Chang-Gyun;Son, Bongsoo
    • Journal of Korean Society of Transportation
    • /
    • v.33 no.1
    • /
    • pp.90-99
    • /
    • 2015
  • The climate of Korea has clear rainy and dry season due to seasonal wind. In general, The rainy season in Korea is from early summer through to early fall. And precipitation accounted for more than half of the total annual rainfall in this period. This study is aiming to analysis of variation in saturation flow rate at signalized intersection during rainfall. The range of spatial is urban signalized intersections in Seoul and temporal is rainfall or ideal condition in daylight. Traffic data are collected through CCTV of Seoul Metropolitan Police Agency, and on-site video recordings directly. Weather condition data are collected from the Korea Meteorological Administration. In addition, the value of saturation headway and saturation flow rate, in rainfall condition, are derived through video frame analysis. As a results of analysis, decrease of saturation flow rate and increase of saturation headway during rainfall were confirmed by comparison with non-rainfall. The higher rainfall rate is, the more decreased saturation flow rate at the intersections. Rainfall rate is divided three area by the results of statistical test, and saturation flow rate decrease 7%, 17%, 21%, respectively.