• 제목/요약/키워드: sapphire-loaded cavity

검색결과 6건 처리시간 0.021초

Accurate Measurements of the Unloaded Q of a Dielectric-loaded High-Q $TE_{01{\delta}}$ mode Cavity Resonator with HTS Endplates

  • Kwon, H.J.;Hur, Jung;Lee, Sang-Young
    • Progress in Superconductivity
    • /
    • 제1권1호
    • /
    • pp.36-41
    • /
    • 1999
  • Methods for mode identification and accurate measurements of the unloaded Q ($Q_0$) of a dielectric-loaded $TE_{01{\delta}}$ mode cavity resonator with HTS endplates are proposed. A resonator with a sapphire rod and $YBa_2Cu_3O_{7-x}$(YBCO) endplates was prepared and its microwave properties were studied at temperatures above 30 K. The $TE_{01{\delta}}$ mode $Q_0$ of the resonator, designed to work as a tunable resonator with variations in the gap distance (s) between the sapphire rod and the top YBCO, was more than 1000000 at s = 0 mm and at 30 K with the resonant frequency of 19.56 GHz. The $TE_{01{\delta}}$ mode $Q_0$ decreases as s increases for s < 2 mm until mode couplings between the $TE_{01{\delta}}$ mode and other modes appeared at s = 2 mm. Significant dependence of the $TE_{01{\delta}}$ mode $Q_0$ on the input and output coupling constants was also observed. Applications of the open-ended $TE_{01{\delta}}$ mode cavity resonator for a tunable resonator with a very high Q as well as a characterization tool for the surface resistance measurements of HTS films are described.

  • PDF

고온초전도 박막이 설치된 유전체부하 공진기의 주파수 조절 가능한 High-Q 공진기 제작 및 대면적 고온초전도 박막의 특성평가에의 응용 (Application of Dielectric-loaded Cavity Resonators with HTS Endplates for Tunable High-Q Resonators and Characterization Tools for Large HTS Films)

  • 권형준;박종운;강훈;허정;이상영
    • 한국초전도학회:학술대회논문집
    • /
    • 한국초전도학회 1999년도 High Temperature Superconductivity Vol.IX
    • /
    • pp.75-82
    • /
    • 1999
  • TE$_{01\;{\delta}}$ mode Cavity Resonators with a low loss dielectric rod and YBa$_2Cu_3O_{7-{\delta}}$ (YBCO) endplates were prepared and their microwave properties were studied at temperatures above 30 K. Both sapphire and rutile were used as the dielectrics. The TE$_{01\;{\delta}}$ mode Q$_0$ of the resonator, designed to work as a tunable resonator with variations in the gap distance (s) between the dielectric rod and the top YBCO, was more than 1000000 at s = 0 mm and at 30 K and .the resonant frequency of 19.56GHz when a sapphire rod was used for the dielectric. The TE$_2Cu_3O_{7-{\delta}}$ mode resonant frequency (f$_0$) appeared to decrease as the temperature is raised. Meanwhile, the temperature dependence of the TE$_2Cu_3O_{7-{\delta}}$ mode f$_0$ of the rutile-loaded resonator appeared different with f$_0$ increasing according to the temperature and Q$_0$ more than 300000 at 30 K and f$_0$ = 8.56 CHz. Comparisons were made between the microwave properties of the sapphire-loaded and the rutile-loaded resonators. Also, applications of the TE$_2Cu_3O_{7-{\delta}}$ mode cavity resonator for a tunable resonator with a very high Q$_0$ as · well as a characterization tool for surface resistance measurements of HTS films are described.

  • PDF

An automated measurement system for the microwave surface resistance of high-T$_c$ superconductor films

  • Lee, J.H.;Lim, J.;Lee, Jung-Hun;Lee, Sang-Young
    • 한국초전도학회:학술대회논문집
    • /
    • 한국초전도학회 2000년도 High Temperature Superconductivity Vol.X
    • /
    • pp.173-178
    • /
    • 2000
  • A prototype for a highly sensitive, automated measurement system for the microwave surface resistance of high-T$_c$ superconductor films was set up, and tested by measuring the microwave surface resistances of high-T$_c$ YBa$_2$Cu$_3$O$_{7-{\delta}}$(YBCO) films at the frequency of about 19.6 GHz and the temperature of 30 K ${\sim}$ 90 K. An open-ended TE$_{011}$ mode sapphire-loaded cylindrical cavity resonator was used as the measurement probe, where YBCO films were used as the endplates of the cylindrical cavity. The characteristics of the measurement system include functions to display the unloaded ${\varrho}$ and the resonant frequency of the TE$_{011}$ mode resonator as well as the microwave surface resistance of the YBCO films, all simultaneously as a function of temperature. Applicability of the measurement system for investigating the homogeneity in the microwave properties of large high-T$_c$ superconductor films is discussed.

  • PDF

An Automated Measurement System for the Microwave Surface Resistance of High-$T_c$ Superconductor Films

  • Lee, J.H.;Lim, J.;Lee, Jung-Hun;Lee, Sang-Young
    • Progress in Superconductivity
    • /
    • 제2권1호
    • /
    • pp.27-32
    • /
    • 2000
  • A prototype for a highly sensitive, automated measurement system for the microwave surface resistance of high-$T_c$ superconductor films was set up, and tested by measuring the microwave surface resistances of high-$T_c$ $YBa_2Cu_3O_{7-\delta}$ (YBCO) films at the frequency of about 19.6 GHz and the temperature of 30 K $\sim$ 90 K. An open-ended $TE_{011}$ mode sapphire-loaded cylindrical cavity resonator was used as the measurement probe, where YBCO films were used as the endplates of the cylindrical cavity. The characteristics of the measurement system include functions to display the unloaded Q and the resonant frequency of the $TE_{011}$ mode resonator as well as the microwave surface resistance of the YBCO films, all simultaneously as a function of temperature. Applicability of the measurement system for investigating the homogeneity in the microwave properties of large high-$T_c$ superconductor films is discussed.

  • PDF

마이크로스트립 공진기와 Rutile-loaded Cavity 공진기로 측정한 $YBa_2$$Cu_3$$O-{7-$\delta$}$박막의 마이크로파 표면저항 비교 연구 (A Comparative Study for the Microwave Surface Resistances of $YBa_2$$Cu_3$$O-{7-$\delta$}$ Films Measured with a Microstrip Resonator and a Inutile-loaded Cavity Resonator)

  • O. K. Kwon;H. J. Kwon;Lee, J. H.;Jung Hur;Lee, Sang-Young
    • Progress in Superconductivity
    • /
    • 제2권2호
    • /
    • pp.86-91
    • /
    • 2001
  • Temperature dependences of the unloaded Q(Q$_{0}$) and the resonant frequency ( $f_{0}$) of YB $a_2$C $u_3$ $O_{7-{\delta}}$ (YBCO) microstrip ring resonators and rutile-loaded cylindrical cavity resonators were measured at low temperatures. Dc magnetron-sputtered YBCO films grown on Ce $O_2$-buffered r-cut sapphire (CbS) substrates were used fur this purpose. The surface resistances ( $R_{s}$) of YBCO films measured by both a microstrip ring resonator and a TE $01\delta$/ mode rutile-loaded cylindrical cavity resonator are compared with each other. It turned out that the values of $R_{s}$ measured by the microstrip resonator technique are comparable to those by the rutile-loaded resonator technique at temperatures lower than ~50 K. However, above 50 K, the $R_{s}$ measured by the microstrip resonator technique appeared higher according to the temperature. Our results show that the current crowding effects near the edge of a microstrip resonator become more significant at temperatures near the critical temperature.emperature.e.e.e.e.e.e.

  • PDF

루타일이 삽입된 유전체 공진기의 두 공진 모드를 이용한 루타일의 유전손실과 $YBa_2Cu_3O_{7-{\delta}}$ 박막의 마이크로파 표면저항 측정 (Simultaneous Measurements of the Loss Tangent of Rutile ($TiO_2$) and the Microwave Surface Resistance of $YBa_2Cu_3O_{7-{\delta}}$ Films using Two Resonant Modes of Rutile -loaded cavity Resonator)

  • 임준;이재훈;김민정;허정;이상영
    • Progress in Superconductivity
    • /
    • 제4권2호
    • /
    • pp.137-143
    • /
    • 2003
  • In measuring the microwave surface resistance of high-Tc superconductor (HTS) films using the dielectric-loaded cavity resonator method, one of the most important factors that limit the measurement sensitivity is the measurement error in the loss tangent ($tan\delta$) of the dielectric rod placed inside the cavity. We have measured the effective surface resistance ( $R_{S}$ $^{eff}$) of$ YBa_2$$_Cu3$$_{7-{\delta}}$ (YBCO) films and the $tan\delta$ of rutile ($TiO_2$) using the 'two-tone'method suggested by Kobayashi et at. [IEEE, MTT-S Digest, 495, (2001)], which enables simultaneous measurements of both the $R_{S}$ $^{eff}$ fof HTS films and the $tan\delta$ of the rutile with high sensitivity. A rutile-loaded cavity resonator with the $TE_{012}$ and $TE_{021}$ resonant frequencies at 13.67 - 14.01 GHz is used for this purpose. At temperatures where the two modes do not couple with other modes, the $R_{S}$ $^{eff}$ of YBCO films and $tan\delta$ of rutile measured by the two-tone method appear to match well with the corresponding values measured using the reported $tan\delta$ values of sapphire within 10 %. Usefulness of the 'two-tone' method for microwave characterization of HTS films and dielectrics is discussed.d.ielectrics is discussed.ussed.

  • PDF