• Title/Summary/Keyword: sand, sand concrete

Search Result 801, Processing Time 0.023 seconds

The effect of high-temperature on foamed concrete

  • Canbaz, Mehmet;Dakman, Hafid;Arslan, Baris;Buyuksungur, Arda
    • Computers and Concrete
    • /
    • v.24 no.1
    • /
    • pp.1-6
    • /
    • 2019
  • Within the scope of this study, the foam solution was prepared by properly mixing sulfonate based foam agent with water. Furthermore, this solution was mixed with the mixture of fine sand, cement, and water to produce foamed concrete. The mixture ratios which are the percentage of foam solution used in foam concrete were chosen as 0, 20, 40 and 60% by vol. After these groups reached 28 days of strength, they were heated to 20, 100, 400 and $700^{\circ}C$ respectively. Afterward, high-temperature effects on the foamed concrete were obtained by employing physical and mechanical properties tests. Additionally, SEM (scanning electron microscope) and EDX (energy-dispersive X-ray spectroscopy) tests were employed to analyze the microstructure, and ${\mu}-CT$ (micro computed tomography) images were used to reconstruct 3-D models of the heat-treated specimens. Then, these models are analyzed to examine the void structures and the changes in these structures due to the high temperatures. The study has shown that the void structures reduce the high-temperature effects and the foam solution could be mixed with concrete up to 40 % by vol. where the high strength of foamed concrete is non-mandatory.

Deformation Characteristics of Flexible Pipe with Variation of Buried Conditions (매설조건에 따른 연성관의 변형특성)

  • Lee, Bongjik
    • Journal of the Korean GEO-environmental Society
    • /
    • v.15 no.10
    • /
    • pp.53-62
    • /
    • 2014
  • In Korea, the pipe type that has been well used as sewage pipe from the past is primarily a rigid pipe which is represented by concrete hume pipe, but the use of it is being decreased sharply because of the problems such as tube erosion and incomplete watertightness securing through the time. On the other hand, the use of flexible pipe has been increased because its construction ability is excellent on account of its light weight as well as it is resistant to corrosion. However, because there are lacks of market's confidence in flexible pipe and occurrence cases of partial damage incomplete caused by compaction control, cause analysis and management for them are needed. Therefore, this study tried to estimate the deformation characteristics of pipe caused by each condition through numerical analysis changing construction sequence, rigidity of pipe, strength of ground concrete under the pipe, relative compaction ratio of sand foundation under the pipe and relative compaction ratio of backfill material above the pipe. Evaluation result is that influence on each factor is confirmed and the quality control of sand around the pipe are turned up to be important.

Durability Assessment for Crushed Sand Wet-mix Shotcrete Mixed with Mineral Admixtures (부순모래를 사용한 습식 숏크리트의 광물성 혼화재료 혼입에 따른 내구성 평가)

  • Lee, Kyeo-Re;Han, Seung-Yeon;Nam Gung, Kyeong;Yun, Kyong-Ku
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.5
    • /
    • pp.607-614
    • /
    • 2014
  • The purpose of this dissertation was to investigate the effect of mineral admixtures, such as fly ash, blast furnace slag powder, meta kaolin and silica fume, on the basic properties and durability of crushed sand shotcrete, selecting a series of shotcrete mixtures with a variable admixture. Compressive strength increased as the content of mineral admixtures increased, specially it was the most effective when using meta kaolin both at sample specimen and core after shotcreting. Rapid chloride ion permeability test and sulfuric acid resistance test showed that both durability increased as the substitute rate of mineral admixture increased. In air void analysis with image analysis, the targeted the spacing factor and specific surface were not satisfied because air-entrained agent was not used.

Effect of Particle Breakage on Compaction and Thermal Resistivity of Concrete-based Recycled Aggregates (콘크리트 재생 순환골재의 파쇄 효과에 따른 다짐 및 열저항 특성 연구)

  • Kang, Sungchul;Kim, Gyeonghun;Wi, Jihae;Ahn, Taebong;Lee, Dae-Soo;Choi, Hangseok
    • Journal of the Korean Geotechnical Society
    • /
    • v.31 no.10
    • /
    • pp.17-28
    • /
    • 2015
  • The strict regulations on eco-friendly construction and the significant reduction of natural aggregate resources have raised public concerns on the utilization of recycled aggregates for backfilling a power transmission pipeline trench. In this paper, the particle breakage of concrete-based recycled aggregates and river sand has been experimentally studied during the standard compaction test. The applied compaction energy does not significantly break the river sand particles down, and thus causes no change in the compaction curve, thermal resistivity, and particle gradation characteristics. On the other hand, considerable particle breakage was observed in case of the three recycled aggregates. Such particle breakage leads to enhancing compaction effort, reducing thermal resistivity, and changing particle gradation curve with finer particles that are broken during the first compaction. In addition, particle breakage is more dramatic in lower water contents because pore water may damp down the compaction energy.

Recycling and characterization of bone incorporated with concrete for gamma-radiation shielding applications

  • U. Rilwan;G.M. Aliyu;S.F. Olukotun;M.M. Idris;A.A. Mundi;S. Bello;I. Umar;A. El-Taher;K.A. Mahmoud;M.I. sayyed
    • Nuclear Engineering and Technology
    • /
    • v.56 no.7
    • /
    • pp.2828-2834
    • /
    • 2024
  • This research intends to recycle bone and incorporate it into concrete for radiation shielding application using Phy-X/PSD software. Cement, sand and granite were mixed in proportion of 0.5 kg:1 kg:1 kg to obtain sample A. Other concretes composing of cement, sand, granite and bone ash was in proportion 0.45 kg:1 kg:1 kg:0.05 kg, 0.1 kg:1 kg:1 kg:0.4 kg and 0.35 kg:1 kg:1 kg:0.15 kg to obtain samples B, C and D respectively. 0.5 water-to-cement (W/C) ratio was adopted throughout the mixes because the control mix contain the normal water quantity for normal hydration of cement. Replacing the bone ash for the cement in the fabricated concretes enhances their densities where the fabricated concretes' density decreased from 2.33 g/cm3 to 2.22 g/cm3 by raising the reinforcing bones fly ash concentration from 0 to 0.15 kg. Additionally, increasing the bones fly ash concentration within the fabricated concretes increases their linear attenuation coefficient (LAC) where the fabricated concretes' μ values at 0.662 MeV reach 0.181 cm-1, 0.178 cm-1, 0.174 cm-1, and 0.171 cm-1, respectively for concretes A, B, C, and D. The use of other local materials is recommended, as it improves waste management being the major aim of the sustainable development goal.

Lifetime of Insoluble Anode for Cathodic Protection on Concrete Construction

  • Sohn, Kicheon;Chang, Hyunyoung;Kim, Youngsik
    • Corrosion Science and Technology
    • /
    • v.4 no.2
    • /
    • pp.56-59
    • /
    • 2005
  • In rebar concrete structure, the corrosion of rebar can arise the deterioration of concrete structure and may affect the safety of the whole system. Recently, several methods for corrosion protection have been used and are more important for concrete structure using the sand including chloride ion. Among several protections, electrical cathodic protection has been expected to be one of the most useful methods in corrosion protection for reinforcement of concrete structures. The anode for cathodic protection needs high current density, high corrosion resistance and low overvoltage. To fill up the special qualities, the insoluble anodes were developed and these anodes were coated with metal oxide of $TiO_2$, $ZrO_2$, $RuO_2$, and $IrO_2$. Lifetime of these anodes can be one of the important factors affecting the lifetime of concrete structure in cathodic protection. In this work, several anodes were made by sol-gel method and thermal decomposition method and the lifetime of these anodes was evaluated by NACE international standard test method, TM 0294-94. Also, we did analyze the properties of coated metal oxides.

Influence of Binder Type on the Chloride Threshold Level for Steel Corrosion in Concrete

  • Moon Han-Young;Ann Ki-Yong;Jung Ho-Seop;Shin Dong-Gu
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.4 s.88
    • /
    • pp.663-670
    • /
    • 2005
  • The present study concerns the influence of binder type on the chloride-induced corrosion being accompanied by the chloride threshold level (CTL), chloride transport and as their results the corrosion-free lift. Two levels of cement content, $30\%$ PFA and $65\%$ GGBS concrete were employed. It was found that the most dominant factor to the CTL is the entrapped air void content at the steel-concrete interface, irrespective of the chloride binding capacity, binder type and acid neutralisation capacity of cement matrix. The CTL for lower interfacial air void contents was significantly increased up to $1.52\%$ by weight of cement, whereas a same mix produced $0.35\%$ for a higher level of voids. Because of a remarkable reduction in the diffusion fur GGBS concrete, its time to corrosion ranges from 255 to 1,250 days, while the corrosion-free life for control varies from 20 to 199 days sand for $30\%$ PFA concrete from 200 to 331 days.

A Study on the Mechanical Properties of Concrete using Garnet Powder with Industrial By-Products (산업부산물인 가네트 미분말을 이용한 콘크리트의 역학적 성상에 관한 연구)

  • 임병호;김태곤;박정민;김화중
    • Journal of the Korea Concrete Institute
    • /
    • v.11 no.3
    • /
    • pp.123-130
    • /
    • 1999
  • In a preceding study(1), the using method of garnet powder has been studies through the various investigation of basic material properties on garnet powder, industrial by-products generated in Yungju, Kyungpook. In this study, the various properties of concrete mixed with garnet powder are examined as following condition : Unit weight of water (170kg/㎥), water-binder ratio W/B (53, 55 and 58%), sand-aggregate ratio (S/A) (43, 45 and 48%), substitutional ratio of garnet powder of 0, 5, 10, 15 and 20%. Slump increased a little as the substitutional ratio of garnet increased. Air content decreased a little at the substitutional ratio of 10%. or more. Though there is a little difference in compressive strength according to the W/B and the substitutional ratio, compressive strength of concrete using garnet exceeded that of plain concrete a little in the range of the substitutional ration of 5 to 15%. Also, There is a similar tendency in the tensile and flexural strength. Therefore, the use of garnet powder with industrial by-products is expected to improve the workability and the strength of concrete.

A predictive model for compressive strength of waste LCD glass concrete by nonlinear-multivariate regression

  • Wang, C.C.;Chen, T.T.;Wang, H.Y.;Huang, Chi
    • Computers and Concrete
    • /
    • v.13 no.4
    • /
    • pp.531-545
    • /
    • 2014
  • The purpose of this paper is to develop a prediction model for the compressive strength of waste LCD glass applied in concrete by analyzing a series of laboratory test results, which were obtained in our previous study. The hyperbolic function was used to perform the nonlinear-multivariate regression analysis of the compressive strength prediction model with the following parameters: water-binder ratio w/b, curing age t, and waste glass content G. According to the relative regression analysis, the compressive strength prediction model is developed. The calculated results are in accord with the laboratory measured data, which are the concrete compressive strengths of different mix proportions. In addition, a coefficient of determination $R^2$ value between 0.93 and 0.96 and a mean absolute percentage error MAPE between 5.4% and 8.4% were obtained by regression analysis using the predicted compressive analysis value, and the test results are also excellent. Therefore, the predicted results for compressive strength are highly accurate for waste LCD glass applied in concrete. Additionally, this predicted model exhibits a good predictive capacity when employed to calculate the compressive strength of washed glass sand concrete.

Plastic viscosity based mix design of self-compacting concrete with crushed rock fines

  • Kalyana Rama, JS;Sivakumar, MVN;Vasan, A;Kubair, Sai;Ramachandra Murthy, A
    • Computers and Concrete
    • /
    • v.20 no.4
    • /
    • pp.461-468
    • /
    • 2017
  • With the increasing demand in the production of concrete, there is a need for adopting a feasible, economical and sustainable technique to fulfill practical requirements. Self-Compacting Concrete (SCC) is one such technique which addresses the concrete industry in providing eco-friendly and cost effective concrete. The objective of the present study is to develop a mix design for SCC with Crushed Rock Fines (CRF) as fine aggregate based on the plastic viscosity of the mix and validate the same for its fresh and hardened properties. Effect of plastic viscosity on the fresh and hardened properties of SCC is also addressed in the present study. SCC mixes are made with binary and ternary blends of Fly Ash (FA) and Ground Granulated Blast Slag (GGBS) with varying percentages as a partial replacement to Ordinary Portland Cement (OPC). The proposed mix design is validated successfully with the experimental investigations. The results obtained, indicated that the fresh properties are best achieved for SCC mix with ternary blend followed by binary blend with GGBS, Fly Ash and mix with pure OPC. It is also observed that the replacement of sand with 100% CRF resulted in a workable and cohesive mix.