• 제목/요약/키워드: sampling rate of frequency

검색결과 276건 처리시간 0.022초

I/Q 보정기능을 갖는 3차원 레이더 신호처리기용 고속 A/D 변환 기법 연구 (The study on high speed A/D conversion implementation employing I/Q compensating algorithm for 3-D radar signal processor)

  • 조명제;김수중
    • 전자공학회논문지S
    • /
    • 제34S권6호
    • /
    • pp.67-76
    • /
    • 1997
  • In radar signal processing, an A/D converter with sufficient dynamic range and high sampling speed is required to detect the weakest target signals in heavy clutter and ECM environments. As the sampling frequency increases, the amount of digital data transfered to the signal processing module is also increased. To overcome these massive data transfer burden, we need an A/D conversion module with an enough data transfer rate. In this paper, we proposed an implementation scheme of a new A/D conversio module that can be used in multi-mode 3-D phased array radar signal processing system, and evaluated the performance. The proposed A/D conversion module is implemented with a standard A/D converter and a 6U-standard VME bus.

  • PDF

단일주파수분석을 이용한 심폐소생술 흉부압박깊이 추정 (Estimation of Chest Compression Depth during Cardiopulmonary Resuscitation by using Single Frequency Analysis)

  • 유원상;강성민;최성욱
    • 대한의용생체공학회:의공학회지
    • /
    • 제38권4호
    • /
    • pp.211-217
    • /
    • 2017
  • During the emergency situation such as cardiac arrest, cardiopulmonary resuscitation(CPR) is the most important treatment to maintain patient's blood circulation. Since the quality of CPR can not be easily measured or evaluated by the eye, an assistive device with an accelerometer can help to assess the pressure depth of CPR. In this study, we propose a single frequency analysis method to reduce the error of the accelerometer by extracting only one frequency component from the Fourier transform process. To verify the effectiveness of the single frequency analysis, acceleration data at CPR conditions were measured at a sampling rate of 50 / sec using a wristband equipped with an acceleration sensor. Then, We compared the existing distance estimation method and the single frequency analysis method using the measured data. The amplitude value proportional to the compression depth was obtained by applying the single frequency analysis method.

디지털주파수계전기의 고속 샘플링추정기법 (A Technique for Fast Sampling Measurement of Digital Frequency Relay)

  • 남시복;이훈구;마석범;김진수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.185-190
    • /
    • 2006
  • Frequency and phasor are the most important quantities in power system operation because they can reflect the whole power system situation. Frequency reflects the dynamic energy balance between load and generating power, while operators use phasor to constitute the state of system and, moreover, phasor based line relays are currently used in most power systems. So frequency and phasor are regarded as indices for the operating power systems in practice. The proposed technique is suitable for estimation near-nominal, nomina), and off-nominal frequencies. It is useful in designing microprocessor-based relays and meters that need to measure power system frequency. Performance test results, using signals from EMTP source and Excel program, indicate that the proposed technique can provide accurate estimates within 16ms. Maximum estimation errors observed during testing are of the order of 0.006Hz for nominal, near-nominal, and off-nominal frequencies. The proposed technique provides accurate estimates in presence of noise and harmonics and in case ground fault. The rate change of the phase angle is used for estimation. To confirm the validity of the proposed algorithm, the simulation studies carried out on a typical 154[KV] double T/L system by using EMTP software. Some test results are presented in the paper.

  • PDF

주파수 영역상의 AR 모델링 기반 이용한 LR-WPAN용 무선측위기법 (A Frequency Domain based Positioning Method using Auto Regressive Modeling in LR-WPAN)

  • 홍윤기;배승천;최성수;이원철
    • 한국통신학회논문지
    • /
    • 제34권6C호
    • /
    • pp.561-570
    • /
    • 2009
  • 임펄스 기반의 초광대역 통신 기술은 이론적으로 근거리에서 고속의 데이터 전송과 고해상도의 거리 인지 및 무선 측위가 가능하다는 장점을 가지고 있지만 이러한 기능들을 수행하기 위해서는 우선적으로 고속의 ADC(Analog to Digital Convertor)가 요구되며 특히, 시간 기반의 무선 측위 기법을 적용할 경우 더욱 그러하다. 그러나 현실적으로 GHz 이상의 고속의 ADC는 매우 고가이기 때문에 본 논문에서 목표로 하는 저비용을 고려한 저속의 무선 개인 영역 네트워크 (Low Rate - Wireless Personal Area Network; LR-WPAN)에서는 부적합하다. 따라서 본 논문에서는 저속의 ADC로 고정밀의 무선 측위가 가능한 주파수 영역에서 계산의 복잡도가 낮은 AR(Auto Regressive) 모델을 기반으로한 레인징 기법을 소개하고, 아날로그 단에서 주파수 변환을 위해 카운터를 이용한 VCO(Voltage Control Oscillator) 방식의 non-coherent 기반의 수신 구조를 제안한다. 제안된 기법에 대한 성능을 검증하기 위해서 IEEE 802.15.4a TG에서 제시한 채널 모델을 적용하였으며 시뮬레이션 결과로부터 제안된 레인징 및 측위 방안의 우수성을 검증하였다.

국제공동연구 PARTRIDGE를 통한 확률론적 건전성 평가 기술 개발 현황 (Current Status of an International Co-Operative Research Program, PARTRIDGE (Probabilistic Analysis as a Regulatory Tool for Risk-Informed Decision GuidancE))

  • 김선혜;박정순;김진수;이진호;윤은섭;양준석;이재곤;박홍선;오영진;강선예;윤기석;박재학
    • 한국압력기기공학회 논문집
    • /
    • 제9권1호
    • /
    • pp.62-69
    • /
    • 2013
  • A probabilistic assessment code, PRO-LOCA ver. 3.7 which was developed in an international co-operative research program, PARTRIDGE was evaluated by conducting sensitivity analysis. The effect of some variables such as simulation methods (adaptive sampling, iteration numbers, weld residual stress model), crack features(Poisson's arrival rate, maximum numbers of cracks, initial flaw size, fabrication flaws), operating and loading conditions(temperature, primary bending stress, earthquake strength and frequency), and inspection model(inspection intervals, detectable leak rate) on the failure probabilities of a surge line nozzle was investigated. The results of sensitivity analysis shows the remaining problems of the PRO-LOCA code such as the instability of adaptive sampling and unexpected trend of failure probabilities at an early stage.

Study on Rainfall Characteristics for the Millimeter-wave Communication Systems-Comparisons of Rainfall rate data from Several observation methods.

  • Chung, H.S.;Song, B.H.;Lee, J.H.;Park, K.M.;Lee, K.A.
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 1999년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.132-134
    • /
    • 1999
  • Rainfall characteristics for designing the optimum millimeter-wave communication systems from two rainfall data set was analyzed. Two rainfall data sets were compared; one-minute rainfall rate data, one-hour synoptic observation data. Each data set has different observation method, sampling frequency. We looked for tendency and quality confluence between two data sets. We showed several results using one-minute rainfall data by millimeter-wave attenuation model. A climatological one-minute rainfall rate data set over Korean Peninsula will be made after data quality control procedure

  • PDF

복소 주파수 성분 처리를 통한 TR-UWB 시스템의 성능분석 (Performance Analysis for TR-UWB System Exploiting Complex Frequency-Components)

  • 장동헌;양훈기
    • 한국정보통신학회논문지
    • /
    • 제13권2호
    • /
    • pp.253-260
    • /
    • 2009
  • 본 논문에서는 UWB 펄스 신호를 주파수 성분으로 분리해서 수 MHz정도의 ADC로 디지털 구현이 가능한 새로운 구조의 TR-UWB 시스템의 성능을 수학적으로 분석한 후 기존 시스템과 이론적으로 비교한다. TR-UWB 신호의 주파수 변환 특성 및 복소수 성분들의 평균, 분산 값을 유도하여 이를 활용한 이론적인 SNR 계산을 통해 시스템 성능을 분석하고 SNR 비 관점에서 기존 시스템과의 성능을 비교한다. 모의 실험에서는 AWGN 환경과 IEEE 802.15.3a의 다중경로 채널 환경에서의 BER을 통해 제시한 TR-UWB 시스템의 성능이 기존 시스템보다 우수함을 보인다.

ECG 신호의 가변적인 전력선 잡음 제거를 위한 적응형 차감기법 (Adaptive Subtraction Method for Removing Variable Powerline Interference of ECG)

  • 전홍규;조익성;권혁숭
    • 한국정보통신학회논문지
    • /
    • 제15권2호
    • /
    • pp.447-454
    • /
    • 2011
  • 전력선 잡음은 ECG 신호 분석에 있어 특정 구간의 왜곡을 발생시킬 수 있다. 특히 P와 R파와 같이 부정맥 진단에 중요한 요소가 되는 구간은 전력선 주파수가 샘플링 주파수의 배수(multiple)일 경우와 그렇지 않을 경우에 각각 다른 형태의 잡음으로 나타나며, 잡음의 특성 또한 선형과 비선형으로 나누어진다. 본 논문에서는 ECG 신호의 가변적인 전력선 잡음 제거를 위한 적응형 차감 기법을 제안한다. 제안한 방법은 먼저 전력선 주파수와 샘플링 주파수와의 배수 관계를 multiple과 non-multiple로 구분한 후 각 구간에 대한 선형성 여부를 판단한다. 이후 선형 구간은 이동평균 필터를 이용하여 잡음성분을 추출하고, 비선형 구간 잡음은 선형구간에서 추출되어 임시버퍼에 저장된 잡음 성분을 이용하여 추출한다. 제안한 기법의 P파와 R파 검출성능을 평가하기 위해 MIT-BIH 데이터베이스의 119번 레코드를 사용하였다. 실험 결과 기존 노치 필터의 경우 P파 97.91%, R파 96.66%, 제안한 차감기법의 경우 P파 99.01%, R파 97.93%의 검출결과를 나타내었다.

일부 여고생의 배변실태와 생활습관과의 관련성 (A Study on Factors Affecting Constipation of Female High School Students)

  • 김은주
    • 한국학교ㆍ지역보건교육학회지
    • /
    • 제11권2호
    • /
    • pp.71-87
    • /
    • 2010
  • Objectives: The purpose of this study was to find out the prevalence of constipation, related factors of constipation of female high school students. Methods: The study subjects were 322 students of Y high schools located in a Suwon city, who were selected by the accidental sampling from November 2009. We analyzed the data by frequency analysis, Chi-square test, Logistic regression analysis using SPSS ver.12.0. Results: The results of this study were summarized as follows: A prevalence rate of self-reported constipation was 55.3%. From the Logistic analysis by self-reported method, leading causes of constipation on the students were drinking beverage, the less frequency of having meals, irregular time of having meals, not eating breakfast, insufficient exercise and not evacuating the bowels regularly. Conclusions: Based on these results, intervention to increase the amount of beverage constipation, intake of vegetable, regularity of taking meals, stress management should be provided to prevent the constipation.

  • PDF

PARCOR 분석 방법에 의한 디지털 DTMF 수신기 구현에 관한 연구 (On Implementing the Digital DTMF Receiver Using PARCOR Analysis Method)

  • 하판봉;안수길
    • 대한전자공학회논문지
    • /
    • 제24권2호
    • /
    • pp.196-200
    • /
    • 1987
  • The following methods are proposed for implementing digital dual tone multi-frequency (DTMF) receiver: using infinite impulse response(IIR) digital filters, period-counting algorithm, discrete Fourier transform(DFT), and fast Fourier transform(FFT)[2]. The PARCOR(Partical Correlation) analysis method which has been widly used in the speech signal processing area is applied to the dual tone multi-frequency(DTMF) signal detection. This method is easy to implement digitally and stronger to digit simulation of speech than any other methods proposed up to date. Since sampling rate of 4KHz is used in the DTMF receiver for the detection of input DTMF signal originally sampled at 8KHz, it effects two times higher multiplexing efficiency.

  • PDF