• Title/Summary/Keyword: sampling rate of frequency

Search Result 277, Processing Time 0.022 seconds

The Combined Treatment with Oriental Herbal Medicine and Western Biomedical Medicine among Cerebrovascular Attack Patients (뇌졸중 환자의 한약.양약 복합투여에 관한 단면연구)

  • Park Jong-Ku;Koh Kwang-Wook;Kim Chun-Bae;Choi Seo-Young;Yoo Jun-Sang
    • The Journal of Korean Medicine
    • /
    • v.27 no.1 s.65
    • /
    • pp.1-10
    • /
    • 2006
  • Objectives : The combined treatment (CT) with oriental herbal medicine and western biomedical medicine is prevalent in the world including Korea. But the clinical information on frequency, efficacy and safety of CT at lout cerebrovascular attack hat not known thoroughly yet. This study aimed to identify the status and adverse effects of CT for the treatment of stroke patients. Methods : A self-completed questionnaire survey and medical record survey by oriental medical doctors were performed in 20 Korean Oriental medical hospitals. Of the initial 1,000 in-patients through 2-stage sampling method, 883 were participated in this surrey, resulting in a response rate of 88.3%. Results : Among stroke patients, the proportion of CT was 94.1%. 156 respondents (18.8%): were experienced several adverse effects including headache, dizziness (fatigue), diarrhea, constipation, chest discomfort, etc. The severity of these adverse effects was generally mild to moderate. Although they quitted the CT, 9.8% of patients were not relieved from adverse effects. Conclusions : This study suggests that most patients in Korean Oriental medical hospitals used the combined treatment with oriental herbal medicine and western biomedical medicine for management of stroke. Therefore, the medical professionals should provide comprehensive and up-to-date clinical information about potential benefits and risks of CT to the stroke patients.

  • PDF

Analysis of Partial Discharge Characteristics in SF6 Gas Insulation (SF6 가스절연에서 부분방전의 특성분석)

  • Kim, Sun-Jae;Wang, Guoming;Park, Seo-Jun;Kil, Gyung-Suk;An, Chang-Hwan
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.7
    • /
    • pp.429-434
    • /
    • 2016
  • This paper deals with the characteristics of partial discharge (PD) for the purpose of a condition based maintenance (CBM) of gas insulated switchgears (GIS) in power equipment. Four types of electrode systems such as a protrusion on enclosure (POE), a particle on spacer (POS), a free particle (FP) and a Floating were designed and fabricated. PD pulses were measured using UHF sensor with a frequency range of 300 MHz~1.4 GHz and a DAQ with a sampling rate of 250 MS/s. Discharge inception voltage (DIV), discharge extinction voltage (DEV), and phase resolved partial discharge (PRPD) were analyzed depending on electrode systems. The average DIV in the POS was 28.8 kV. It was about 1.7 times higher than that in the FP, which was the lowest value of 17.2 kV. The FP shuffled and jumped at the applied voltage of 23.5 kV. Over 95% of PD pulses in the POE were generated in the negative polarity ($181^{\circ}{\sim}360^{\circ}$) of applied voltage. The results showed the phase (${\Phi}$)-magnitude (dBm) of PD pulses by UHF sensor, a cluster was formed separately depending on electrode systems.

Research on Digital Complex-Correlator of Synthetic Aperture Radiometer: theory and simulation result

  • Jingye, Yan;Ji, Wu;Yunhua, Zhang;Jiang, Changhong;Tao, Wang;Jianhua, Ren;Jingshan, Jiang
    • Proceedings of the KSRS Conference
    • /
    • 2002.10a
    • /
    • pp.587-592
    • /
    • 2002
  • A new digital correlator fur an airborne synthetic aperture radiometer was designed in order to replace the conventional analog correlator unit which will become very complicated while the number of channels is increasing. The digital correlator uses digital IQ demodulator instead of the intermediate frequency (IF) phase shifter to make the correlation processing performed digitally at base band instead of analogly at IF. This technique has been applied to the digital receiver in softradio. The down-converted IF signals from each pair of receiver channels become low rate base-band digital signals after under-sampled, Digitally Down-Converted (DDC), decimated and filtered by FIR filters. The digital signals are further processed by two digital multipliers (complex correlation), the products are integrated by the integrators and finally the outputs from the integrators compose of the real part and the imaginary part of a sample of the visibility function. This design is tested by comparing the results from digital correlators and that from analog correlators. They are agreed with each other very well. Due to the fact that the digital correlators are realized with the help of Analog-Digital Converter (ADC) chips and the FPGA technology, the realized volume, mass, power consumption and complexity turned out to be greatly reduced compared with that of the analog correlators. Simulations show that the resolution of ADC has an influence on the synthesized antenna patterns, but this can be neglected if more than 2bit is used.

  • PDF

Wireless Electrocardiogram Monitoring System for Small Animals Based on IEEE 802.15.4 (IEEE 802.15.4에 기초한 작은 동물을 위한 무선 심전도 감시 시스템)

  • Kim, Dong-Sik;Jin, Ju-Youn;Jo, Mi-Young;Nam, Do-Hyun
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.3
    • /
    • pp.36-43
    • /
    • 2009
  • Electrocardiogram (ECG) is a graphical record of the voltages generated during the heart beats, and is very useful in observing the status of the heart of the human or animals. In this paper, an ECG monitoring system is developed for the small animals, such as the rat. This system is very useful in monitoring the side effect of drugs. Since small animals have faster heart rate than the human case, the monitoring system has a faster sampling frequency and processing speed. Furthermore, for a realtime monitoring of the small moving animals, the system is composed of a small wireless ECG module, which is based on the IEEE 802.121.4 wireless physical layer. The developed wireless ECG system can successfully monitor the ECG of small animals, such as the rat.

Time Synchronization Technique for GNSS Jamming Monitoring Network System (GNSS 재밍 신호 모니터링 네트워크 시스템을 위한 독립된 GNSS 수신기 간 시각 동기화 기법)

  • Jin, Gwon gyu;Song, Young jin;Won, Jong hoon
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.20 no.3
    • /
    • pp.74-85
    • /
    • 2021
  • Global Navigation Satellite System (GNSS) receivers are intrinsically vulnerable to radio frequency jamming signals due to the fundamental property of radio navigation systems. A GNSS jamming monitoring system that is capable of jamming detection, classification and localization is essential for infrastructure for autonomous driving systems. For these 3 functionalities, a GNSS jamming monitoring network consisting of a multiple of low-cost GNSS receivers distributed in a certain area is needed, and the precise time synchronizaion between multiple independent GNSS receivers in the network is an essential element. This paper presents a precise time synchronization method based on the direct use of Time Difference of Arrival (TDOA) technique in signal domain. A block interpolation method is additionally incorporated into the method in order to maintain the precision of time synchronization even with the relatively low sampling rate of the received signals for computational efficiency. The feasibility of the proposed approach is verified in the numerical simualtions.

Preference Differences in Interior Images of Restaurants according to Lifestyles (라이프스타일 유형에 따른 레스토랑 실내이미지 선호도 차이에 관한 연구)

  • Kim, Tae-Hee;Park, Young-Seok
    • Journal of the Korean Home Economics Association
    • /
    • v.43 no.10 s.212
    • /
    • pp.69-79
    • /
    • 2005
  • The purpose of this study was to determine restaurant patrons' preference differences in interior design style of restaurants according to their lifestyles. Written questionnaires were handed out to 500 adults in Seoul and surroundings and the results were sampled by convenience sampling. The questionnaire was composed of respondents' general characteristics, lifestyles, and preference for 10 types of interior design style. A total of 415 questionnaires were usable for data analysis, resulting in a response rate of $83\%$. To analyze the collected data, frequency, factor, reliability, quick clustering K- means and One-Way ANOVA analysis were conducted using SPSS 10.0. The results showed that there were preference differences in 10 types of interior design style of restaurants according to lifestyle types which were categorized into 4 groups. The conservative and self-convinced group showed the lowest preference scores in the 10 types of interior design style which are Romantic, Ethnic, Classic, High-Tech, Elegant, Country, Modem, Minimal, Natural, and Casual style. The quality life pursuing group and extroverted individuality groups showed the high preference scores in most of the styles, especially in the Classic and Elegant styles. The realistic self-centered group showed the highest preference scores in Casual style among the 4 groups. These study findings indicate that restaurants should take into account their patrons' lifestyles as a mean of market segmentation, and respond to their taste and preference when they have established suitable servicescape.

CROSS-INTERFEROMETRY FOR DEM CONSTRUNTION WITH ERS-ENVISAT PAIR

  • Hong Sang-Hoon;Won Joong-Sun
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.542-545
    • /
    • 2005
  • Spaceborne radar interferometry has been widely used to estimate the topography and deformation of the Earth. It is difficult to obtain coherent interferometric SAR pairs especially over coastal areas mainly because of variation of surface conditions. We carried out the experiment using a cross-interferometric pair with a perpendicular baseline of about 1.4 km, a 30 minutes temporal separation and the height sensitivity of about 6 meters. The temporal decorrelation can be reduced by the cross interferometric technique with a 30 minutes temporal separation. Accurate coregistration was performed through resampling of ENVISAT ASAR data to equivalent pixel spacing to the ERS SAR data, because of the differences of the pulse repetition frequency and range sampling rate between the two sensors. Then we estimated range and azimuth offset to a sub-pixel accuracy using image intensity cross correlation. A larger window chip size than a general case was used because it was difficult to distinguish typical features. As range bin increased, the difference of Doppler centroid also increased. It resulted in lower coherence in far range than in near range. Coherences over wetland in near and far range were about 0.8 and 0.5, respectively. The coherence was improved by applying azimuth and range common band filtering, but coherence gap still existed. ERS-ENVISAT cross-interferogram usually lost information in urban area. However, high coherence over a city in this pair was shown, because of less man-made structures than other major cities. Accuracy of the DEM constructed by the ERS-ENVISAT 30-minute pair in a coastal area is to be evaluated.

  • PDF

A Study on Stress Incontinence in Women in Korea (여성의 긴장성 요실금에 관한 연구)

  • Lee, Young-Sook
    • 모자간호학회지
    • /
    • v.4 no.1
    • /
    • pp.12-23
    • /
    • 1994
  • This study was done to determine the situations of stress incontinence(SI) and the differences in general characteristics, obstetrical history and SI related variables between women with stress incontinence and normal women. The design for study was a descriptive study. The number of subjects consisted of 156 women who were selected by systematic random sampling in Kwangju city. Data collection was done with the modified Hendrickson's Stress Incontinence Scale(1981) which was analyzed using frequency and percentiles. The results were as follows : 1. The stress incontinence (SI) rate of the sample was 64.1% and the majority of the women(40.9%) had experienced SI for a period of five years(the mean period was 2.7 years) without any treatment or care(83.0%). The amount of SI was from one drop(40.0%) to one teaspoon(16.7%) daily. 2. Items on the SI scale had the scores ranging from 4 to 44 with a mean score of 13.7 which showed mild SI. 3. The priority of provocative factors for SI were abdominal tightening(83%), coughing(58%), laughing(52%), sneezing(40%), steeping(18%), sudden standing(17%), nose blowing(13%), heavy exercise(11%), rapid walking up-stairs(10%) and excitment (9%) in that order. 4. There were no significant differences in age, education, spouse, job and income between the women with SI and the normal women. 5. There were no significant differences in the age at the last delivery, age of last baby. number of vaginal, or cesarean deliveries, or abdominal operations between the women with SI and the normal women. It can be concluded that SI in women has a high incidence nth various provocative factors but it is relatively mild SI on a daily basis and generally there has been no treatment. It is suggested that a descriptive study of emotional problems and precipitating variables in SI women will increase the knowledge of SI.

  • PDF

Experimental investigation of Scalability of DDR DRAM packages

  • Crisp, R.
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.17 no.4
    • /
    • pp.73-76
    • /
    • 2010
  • A two-facet approach was used to investigate the parametric performance of functional high-speed DDR3 (Double Data Rate) DRAM (Dynamic Random Access Memory) die placed in different types of BGA (Ball Grid Array) packages: wire-bonded BGA (FBGA, Fine Ball Grid Array), flip-chip (FCBGA) and lead-bonded $microBGA^{(R)}$. In the first section, packaged live DDR3 die were tested using automatic test equipment using high-resolution shmoo plots. It was found that the best timing and voltage margin was obtained using the lead-bonded microBGA, followed by the wire-bonded FBGA with the FCBGA exhibiting the worst performance of the three types tested. In particular the flip-chip packaged devices exhibited reduced operating voltage margin. In the second part of this work a test system was designed and constructed to mimic the electrical environment of the data bus in a PC's CPU-Memory subsystem that used a single DIMM (Dual In Line Memory Module) socket in point-to-point and point-to-two-point configurations. The emulation system was used to examine signal integrity for system-level operation at speeds in excess of 6 Gb/pin/sec in order to assess the frequency extensibility of the signal-carrying path of the microBGA considered for future high-speed DRAM packaging. The analyzed signal path was driven from either end of the data bus by a GaAs laser driver capable of operation beyond 10 GHz. Eye diagrams were measured using a high speed sampling oscilloscope with a pulse generator providing a pseudo-random bit sequence stimulus for the laser drivers. The memory controller was emulated using a circuit implemented on a BGA interposer employing the laser driver while the active DRAM was modeled using the same type of laser driver mounted to the DIMM module. A custom silicon loading die was designed and fabricated and placed into the microBGA packages that were attached to an instrumented DIMM module. It was found that 6.6 Gb/sec/pin operation appears feasible in both point to point and point to two point configurations when the input capacitance is limited to 2pF.

Optimized Sigma-Delta Modulation Methodology for an Effective FM Waveform Generation in the Ultrasound System (효율적인 주파수 변조된 초음파 파형 발생을 위한 최적화된 시그마 델타 변조 기법)

  • Kim, Hak-Hyun;Han, Ho-San;Song, Tai-Kyong
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.3
    • /
    • pp.429-440
    • /
    • 2007
  • A coded excitation has been studied to improve the performance for ultrasound imaging in term of SNR, imaging frame rate, contrast to tissue ratio, and so forth. However, it requires a complicated arbitrary waveform transmitter for each active channel that is typically composed of a multi-bit Digital-to-Analog Converter (DAC) and a linear power amplifier (LPA). Not only does the LPA increase the cost and size of a transmitter block, but it consumes much power, increasing the system complexity further and causing a heating-up problem. This paper proposes an optimized 1.5bit fourth order sigma-delta modulation technique applicable to design an efficient arbitrary waveform generator with greatly reduced power dissipation and hardware. The proposed SDM can provide a required SQNR with a low over-sampling ratio of 4. To this end, the loop coefficients are optimized to minimize the quantization noise power in signal band while maintaining system stability. In addition, the decision level for the 1.5 bit quantizer is optimized for a given input waveform, which results in the SQNR improvement of more than 5dB. Computer simulation results show that the SQNR of a FM(frequency modulated) signal generated by using the proposed method is about 26dB, and the peak side-lobe level (PSL) of its compressed waveform on receive is -48dB.