• Title/Summary/Keyword: sampling rate of frequency

Search Result 277, Processing Time 0.033 seconds

Vacuum Assisted Auto-Lancing Technique for Capillary Blood Sampling on the Forearm with Minimized Pain (전완부위 최소통증 채혈을 위한 진공 자동 채혈기법)

  • Park Mi Sook;Park Kyung Soon;Kim Kyung Ah;Jun Myung Hee;Kim Tae Im;Lee Tae Soo;Cha Eun Jong
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.557-563
    • /
    • 2004
  • A new vacuum assisted auto-lancing technique is proposed to minimize pain. Specially designed lancing device was introduced, which applied -100mmHg right after skin puncture on the forearm. Sampled blood volumes were measured in 58 normal females. Mean volume of 464 samples was approximately 2.6$\muL$ and the frequency of more than 0.5$\muL$ was 86%. Thus the success rate of blood sugar test should also be the same when using modern glucose meters capable of testing with only 0.3~0.5$\muL$ of capillary blood. When pain scores were quantitatively evaluated by the visual pain measure, only 23% pain of the traditional finger sampling was experienced, demonstrating that capillary blood sampling was performed on the forearm with almost no pain. The present technique reduced pain to a great degree, though resampling might be unavoidable due to 14% of test failure rate estimated for modern glucose meters. However, minimized pain makes the present technique of great convenience for diabetic patients who need blood sampling a few times a day.

The Relationship Between Negotiating Efforts on Leisure Restriction and Participation in Leisure Sports (여가제약 협상노력과 레저스포츠참가의 관계)

  • Kim, Kyong-Silk;Jin, Eun-Hee;Koo, Kyong-Ja
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.449-453
    • /
    • 2009
  • The primary purpose of this study was to probe the relationship between negotiating efforts on leisure restriction and participation in leisure sports. This study has sampled for 26 days from 2009 February 9th to March 6th 250 adult at the age of 19 living in capital area using the Purposive Sampling Method. The study has then divided these samples into 3groups which are : public people, members of an association club, members of a club. To exclude non-participant of leisure sports, the researcher has visited the leisure sports facilities to sampling survey. The collected data were put into the SPSSWIN 15.0 program to be Factor Analysis, Reliability Analysis, Multiple Regression Analysis, Path Analysis. The results are: 1) Negotiating efforts on leisure sports affect the frequency of leisure sports participation: thus, the more effort on leisure activity and eagerness to change the more frequent the participation rate becomes. 2) Negotiating efforts on leisure sports affect the length of leisure sports participation. The means that the recharging through leisure activity and regulatory the intensity can extend the length of participation. 3) Negotiating efforts on leisure sports affect the intensity of participation. The more effort on leisure activity result in higher intensity of participation.

  • PDF

Open-Loop Pipeline ADC Design Techniques for High Speed & Low Power Consumption (고속 저전력 동작을 위한 개방형 파이프라인 ADC 설계 기법)

  • Kim Shinhoo;Kim Yunjeong;Youn Jaeyoun;Lim Shin-ll;Kang Sung-Mo;Kim Suki
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.1A
    • /
    • pp.104-112
    • /
    • 2005
  • Some design techniques for high speed and low power pipelined 8-bit ADC are described. To perform high-speed operation with relatively low power consumption, open loop architecture is adopted, while closed loop architecture (with MDAC) is used in conventional pipeline ADC. A distributed track and hold amplifier and a cascading structure are also adopted to increase the sampling rate. To reduce the power consumption and the die area, the number of amplifiers in each stage are optimized and reduced with proposed zero-crossing point generation method. At 500-MHz sampling rate, simulation results show that the power consumption is 210mW including digital logic with 1.8V power supply. And the targeted ADC achieves ENOB of about 8-bit with input frequency up to 200-MHz and input range of 1.2Vpp (Differential). The ADC is designed using a $0.18{\mu}m$ 6-Metal 1-Poly CMOS process and occupies an area of $900{\mu}m{\times}500{\mu}m$

Output characteristics of ac excited $CO_2$ laser as a adjusting a phase angle and frequency (위상각와 주파수 제어에 따른 상용주파 AC 여기 방식의 펄스형 $CO_2$ 레이저 전원장치 개발에 관한 연구)

  • Chung, Hyun-Ju;Kim, Do-Wan;Lee, Dong-Hoon;Kim, Joong-Mann;Kim, Mee-Je;Cho, Jung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2098-2100
    • /
    • 2000
  • We propose pulsed $CO_2$ laser below 30W by the AC(60Hz) switching control of leakage transformer primary which has some advantage of cost and size compared to a typical pulsed power supply. Pulse repetition rate is adjusted from 5Hz to 60Hz to control laser output. In this laser, a low voltage open loop control for high voltage discharge circuit is employed to avoid the HV sampling or switching and high voltage leakage transformer is used to convert rectified low voltage pulse to high voltage one. A ZCS(Zero Cross Switch) circuit and a PIC one-chip microprocessor are used to control gate signal of SCR precisely. The pulse repetition rate is limited by 60Hz due to the frequency of AC line and a high leakage inductance. The maximum laser output was obtained about 23W at pulse repetition rate of 60Hz, total gas mixture of $CO_{2}/N_{2}$/He = 1/9/15, SCR gate trigger angle 90$^{\circ}$, and total pressure of 18Torr.

  • PDF

Linkage between Digital Down Converter System and Spectrum Sensing Method (Digital Down Converter 시스템과 스펙트럼 센싱 기법 연동 방안)

  • Hong, Moo-Hyun;Moon, Ki-Tak;Kim, Ju-Seok;Kim, Kyung-Seok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.3
    • /
    • pp.43-50
    • /
    • 2010
  • DDC(Digital Down Converter) is a conversion technology to decimate to a lower sampling rate and DDC for the future development of communications technology has the necessary skills. So, it has been recognized in the wireless and the SDR(Software Defined Radio) system as essential components. In addition, research is underway on spectrum sensing for efficient communications environment due to the shortage of frequency resources. In this paper, the DDC systems were analyzed for CIC(Cascaded Integrator Comb) Filter, WDF(Wave Digital Filter), SRC(Sample Rate Conversion) each module. Moreover, we proposed a linkage effectively between DDC system and Spectrum Sensing for improve the efficiency of use of frequency by computer simulations. The simulation results of the DDC system was applied to the spectrum sensing capabilities. Also, performance and complexity of the results were derived and proposed system was the result of the check.

Commercial frequency AC discharge magnetic stimulation operating characteristics (상용교류방전 자기자극장치의 동작특성)

  • Kim, Whi-Young
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.12
    • /
    • pp.2685-2692
    • /
    • 2009
  • We propose pulsed magnetic stimulation below 30W by the AC(60Hz) switching control of leakage transformer primary which has some advantage of cost and size compared to a typical pulsed power supply. Pulse repetition rate is adjusted from 5Hz to 60Hz to control magnetic stimulation output. In this magnetic stimulation, a low voltage open loop control for high voltage discharge circuit is employed to avoid the HV sampling or switching and high voltage leakage transformer is used to convert rectified low voltage pulse to high voltage one. A ZCS(Zero Cross Switch)circuit and a DSP & FPGA are used to control gate signal of SCR precisely. The pulse repetition rate is limited by 60Hz due to the frequency of AC line and a high leakage inductance. The maximum magnetic stimulation output was obtained about 33W at pulse repetition rate of 60Hz, total 40, 80, 120, $160^{\circ}$, SCR gate trigger angle $90^{\circ}$ and total output.

A Seroepidemiological Study on Hepatitis B Vaccination Program - In Elementary School Student from Kyonggi-Do Province - (B형 간염 예방 접종 실태 평가를 위한 혈청 역학적 연구 -경기도 지역 초등학생을 대상으로-)

  • Lee, Suk-Yong;Choi, Boyoul;Shin, Young-Jeon;Bang, Keum-Nie;Ki, Moran;Park, Hung-Bae;Yoon, Jae-Deuk;Lee, Kye-Chol;Youn, Bae-Joong
    • Pediatric Infection and Vaccine
    • /
    • v.4 no.2
    • /
    • pp.240-256
    • /
    • 1997
  • Purpose: To evaluate the hepatitis B vaccination program which has been conducted since 1980, Korea. Methods: This study was carry out self reported questionnaire and serologic test covering 2,072 elementary school students who were born between 1980 and 1987, selected by cluster sampling. The HBV serologic markers (HBsAg, Anti-HBs and Anti-HBc) were tested by radioimmunoassay (RIA). The contents of questionnaire include demographic data of students and parents, vaccination status, vaccination frequency, vaccination age, past history of mother's HBV test. Results: 1) The HBsAg positive rates by sex showed 3.7% for male and 2.7% for female, representing an average rate of 3.4%. The HBsAg positive rates by age group showed 5.6% for 13 years and l.5% for 6 years, representing a tendency of lowering rate as ages being younger. 2) The pre-natal HBV test rate was 10.2%, while post-natal HBV test rate was 42.5%. The test showed that the parents' educational level being higher than others, the pre- and post-natal HBV test showed higher rates. In case the fathers occupation being office worker, the post-natal HBV test showed a higher rate compared with other occupation. 3) Overall vaccination rate was 82.6%, complete vaccination rate 69.8%, booster injection rate 42.8%. The vaccination rate, complete vaccination rate and booster injection rate increased as the age being younger. If the educational level of parents were higher, the vaccination rate, complete vaccination rate and booster injection rate showed higher rates. Younger students showed younger vaccination age, and higher educational background of family showed younger vaccination ages. 4. With regard to positive rate of HBV markers by vaccination age, HBsAg and Anti-HBc positive rate showed higher degrees in the following order; preschool age (1-6 years), school age (6-13 years) and infancy (0-1 year). Anti-HBs positive rate was increased as the frequency of vaccination increased. Five years after initial complete vaccination, minimum protective rate was lowest, 69.6%.

  • PDF

Determination of Appropriate Sampling Frequency and Time of Multiple Blood Sampling Dual Exponential Method with $^{99m}Tc$-DTPA for Calculating GFR (사구체여과율 계산을 위한 $^{99m}Tc$-DTPA를 이용한 다중 채혈 이중지수법의 적정 채혈 횟수 및 시간의 선정)

  • Kim, Chung-Ho;O, Joo-Hyun;Chung, Yong-An;Yoo, Ie-Ryung;Sohn, Hyung-Sun;Kim, Sung-Hoon;Chung, Soo-Kyo;Lee, Hyoung-Koo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.1
    • /
    • pp.33-39
    • /
    • 2006
  • Purpose: To determine appropriate sampling frequency and time of multiple blood sampling dual exponential method with $^{99m}Tc$-DTPA for calculating glomerular filtration rate (GFR). Materials & Methods: Thirty four patients were included in this study. Three mCi of $^{99m}Tc$-DTPA was intravenously injected and blood sampling at 9 different times, 5ml each, were done. Using the radioactivity of serum, measured by gamma counter, the GFR was calculated using dual exponential method and corrected with the body surface area. Using spontaneously chosen 2 data points of serum radioactivity, 15 collections of 2-sample GFR were calculated. And 10 collections of 3-sample GFR and 12 collections of 4-sample GFR were also calculated. Using the 9-sample GFR as a reference value, degree of agreement was analyzed with Kendall's $\tau$ correlation coefficients, mean difference and standard deviation. Results: Although some of the 2-sample GFR showed high correlation coefficient, over or underestimation had evolved as the renal function change. The 10-120-240 min 3-sample GFR showed a high correlation coefficient (${\tau}=0.93$), minimal difference ($Mean{\pm}SD=-1.784{\pm}3.972$), and no over or underestimation as the renal function changed. The 4-sample GFR showed no better accuracy than the 3-sample GFR. Conclusions: In the wide spectrum of renal function, the 10-120-240 min 3-sample GFC could be the best choice for estimating the patients' renal function.

A study on the design exploration of Optical Image Stabilization (OIS) for Smart phone (스마트폰을 위한 광학식 손떨림 보정 설계 탐색에 관한 연구)

  • Lee, Seung-Kwon;Kong, Jin-Hyeung
    • Journal of Digital Contents Society
    • /
    • v.19 no.8
    • /
    • pp.1603-1615
    • /
    • 2018
  • In order to achieve the low complexity and area, power in the design of Optical Image Stabilization (OIS) suitable for the smart phone, this paper presents the following design explorations, such as; optimization of gyroscope sampling rate, simple and accurate gyroscope filters, and reduced operating frequency of motion compensation, optimized bit width in ADC and DAC, evaluation of noise effects due to PWM driving. In experiments of gyroscope sampling frequencies, it is found that error values are unvaried in the frequency above 5KHz. The gyroscope filter is efficiently designed by combining the Fuzzy algorithm, to illustrate the reasonable compensation for the angle and phase errors. Further, in the PWM design, the power consumption of 2MHz driving is shown to decrease up to 50% with respect to the linear driving, and the imaging noises are reduced in the driving frequency above 2MHz driving frequency. The operating frequency could be reduced to 5KHz in controller and 10KHz in driver, respectively, in the motion compensation. For ADC and DAC, the optimized exploration experiments verify the minimum bit width of 11bits in ADC as well as 10bits in DAC without the performance degradation.

Analysis and Compensation of STO Effects in the Multi-band OFDM Communication System of TDM Reception Method (TDM 수신 방식의 멀티 대역 OFDM 통신 시스템에서 STO 특성 분석 및 보상)

  • Lee, Hui-Kyu;Ryu, Heung-Gyoon
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.5A
    • /
    • pp.432-440
    • /
    • 2011
  • For the 4th generation mobile communication, LTE-advanced system needs the broad frequency band up to 100MHz for providing the data rate of maximum 1Gpbs. However, it is very difficult to secure the broad frequency band in the current frequency allocation situation. So, carrier aggregation was proposed as the solution, in which several fragmented frequency bands are used at the same time. Basically, multiple parallel receivers are required to get the information data from the different frequency bands but this conventional multi-chain receiver system is very inefficient. Therefore, in this paper, we like to study the single chain system that is able to receive the multi-band signals in a single receiver based on the time division multiplexing (TDM) reception method. This proposed TDM receiver efficiently manage to receive the multi-band signals in time domain and handle the baseband signals with one DSP board. However, the serious distortion could be generated by the sampling timing offset (STO) in the TDM-based system. Therefore, we like to analyze STO effects in the TDM-based system and propose a compensation method using estimated STO. Finally, it is shown by simulation that the proposed method is appropriate for the single chain receiver and show good compensation performance.