• Title/Summary/Keyword: sampling rate of frequency

Search Result 276, Processing Time 0.022 seconds

ECG Compression Structure Design Using of Multiple Wavelet Basis Functions (다중웨이브렛 기저함수를 이용한 심전도 압축구조설계)

  • Kim Tae-hyung;Kwon Chang-Young;Yoon Dong-Han
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.9 no.3
    • /
    • pp.467-472
    • /
    • 2005
  • ECG signals are recorded for diagnostic purposes in many clinical situations. Also, In order to permit good clinical interpretation, data is needed at high resolutions and sampling rates. Therefore In this paper, we designed to compression structure using multiple wavelet basis function(SWBF) and compared to single wavelet basis function(SWBF) and discrete cosine transform(DCT). For experience objectivity, Simulation was performed using the arrhythmia data with sampling frequency 360Hz, resolution lIbit at MIT-BIH database. An estimate of performance estimate evaluate the reconstruction error. Consequently compression structure using MWBF has high performance result.

Kinematical Aspects Gliding Technique in 500-m Speed Skaters: From Start to Seven Strokes

  • Ryu, Jae Kyun;Kim, Young Suk;Hong, Sung Hong
    • Korean Journal of Applied Biomechanics
    • /
    • v.26 no.4
    • /
    • pp.333-341
    • /
    • 2016
  • Objective: The purpose of this study was to assess the consistency of the gliding and push-off motion for single leg skating from the first to fourteenth steps. We hypothesized that: 1) there would be no difference in stroke trajectory, step rate, and cycle rate between the left and right steps of gliding; and 2) there would be a difference in the resultant velocity of toe push-off and the horizontal velocity of the center of mass after six step push-offs. Method: The study included five male 500-m speed skaters (mean height, $1.80{\pm}0.02m$; mean weight, $76.8{\pm}3.96kg$; record, $35.83{\pm}0.30sec$; 100-m record, <9.97 sec). Data were collected from the first to fourteenth steps (40 m) and recorded using five digital JVC GR-HD1KR video cameras (Victor Co., Japan) operating at a sampling frequency of 60 fields/sec and shutter speed of 1/500 sec. For each film frame, the joint positions were digitized using the KWON3D motion analyzer. Position data were filtered with low-pass Butterworth $4^{th}$ order at the cut-off frequency of 7.4 Hz. Results: The right toe of the skating trajectories at $2^{nd}$, $5^{th}$, and $7^{th}$ strokes differed from those of the left toe. The angles of the right and left knee demonstrated unbalanced patterns from the flexion and extension legs. The step and cycle rates of the right and left leg differed from the start until 20 m. The resultant velocities of the toe at the push-off phase and of the body mass center diverged before the six push-offs. Conclusion: This study's findings indicate that the toe of skating trajectory on left and right sliding after push-off should maintain a symmetrical trajectory. The resultant velocity of toe push-off and horizontal velocity from the center of body need to be separated after about six step push-offs.

Design of Class-II Partial-Response System above the Nyquist Rate (나이퀴스트 속도를 초과하는 제2종 부분응답 시스템의 설계)

  • 오용선
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.2 no.1
    • /
    • pp.27-35
    • /
    • 1998
  • In this paper, we propose a novel spectral-chopping model of Class-II$(1+D)^2$ -PRS system which reveals improved spectral efficiency. We build up the model having spectrum chopped by the amount of Nyquist over-rate, and then compare its characteristics with the conventional model in both the time-domain and the frequency-domain. When the transmission system operates above the Nyquist rate, the new model has better performance than the conventional PRS using its inherent speed-tolerance. According to our investigations, Class-II PRS shows more excellent effect in the spectral-chopping method than Class- I and W types analyzed previously. We ascertain that the over-rate of 26.675 obtained by the inherent speed-tolerance could be improved upto 40% using spectrum-truncation. These effects come from the fact that the raised-cosine spectrum of Class-II PRS has smaller Boss of frequency component and energy than any other types for the same amount of truncation. In order to validate these theoretical results, we present their sidelobe-trends confirming cancellation effects at the sampling instants and some experimental results showing their patterns of eye-openings and spectra.

  • PDF

Design of a 1.2V 7-bit 800MSPS Folding-Interpolation A/D Converter with Offset Self-Calibration (Offset Self-Calibration 기법을 적용한 1.2V 7-bit 800MSPS Folding-Interpolation A/D 변환기의 설계)

  • Kim, Dae-Yun;Moon, Jun-Ho;Song, Min-Kyu
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.3
    • /
    • pp.18-27
    • /
    • 2010
  • In this paper, a 1.2V 7-bit 1GSPS A/D converter with offset self-calibration is proposed. The proposed A/D converter structure is based on the folding-interpolation whose folding rate is 2, interpolation rate is 8. Further, for the purpose of improving the chip performance, an offset self-calibration circuit is used. The offset self-calibration circuit reduce the variation of the offset-voltage,due to process mismatch, parasitic resistor, and parasitic capacitance. The chip has been fabricated with a 1.2V 65nm 1-poly 6-metal CMOS technology. The effective chip area is $0.87mm^2$ and the power dissipates about 110mW at 1.2V power supply. The measured SNDR is about 39.1dB when the input frequency is 250MHz at 800MHz sampling frequency. The measured SNDR is 3dB higher than the same circuit without any calibration.

A Study on the Pulsed $CO_2$ Laser by the Switching Control of Leakage Transformer Primary (누설변압기 1차측의 스위칭 제어에 의한 펄스형 $CO_2$레이저에 관한 연구)

  • Chung, Hyeon-Ju;Lee, Dong-Hoon;Kim, Hee-Je
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.9
    • /
    • pp.541-545
    • /
    • 2000
  • We propose a pulsed $CO_2$laser below 30W by the AC(60Hz) switching control of leakage transformer primary which has some advantages of cost and size compared to a typical pulsed power supply. Pulse repetition rate is adjusted from 5 Hz to 60 to Hz control laser output. In this laser a low voltage open loop control for high voltage pulse discharge circuit is employed to aviod the Hv sampling or switching and high voltage leakage transformer is used to convert low voltage pulse rectified from AC to high voltage one. A ZCS(Zero Crossing Switch) circuit and a PIC(programble one-chip microprocessor are used to control gate signal of SCR precisely. The pulse repetition rate is limited by 60Hz due to the frequency of AC line and a high leadkage inductance. The maximum laser output was about 23 W at pulse repetition rate of 60Hz total gas mixture of $CO_2$ : $N_2$ : He=1: 9: 15 and total pressure of 18 Torr

  • PDF

A Study on the Airborne PCM Telemetry System (탑재형 PCM 원격측정장치에 관한 연구)

  • 강정수;이만영
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.8 no.1
    • /
    • pp.1-11
    • /
    • 1983
  • The object of this paper is to investigate a PCM telemetry system which is designed and constructed in individual modules for an airborne remote measurement system for the first time in Korea. The time division multiplexing PCM encoder has maximum allowable input channels 64 words/frame, 140kbits/sec bit rate. 200frames/sec and 10 bits/wod resolution. And the transmitting unit is designed for 2.2-2.3GHz(s-band) telemetry frequency band, PCM/FM modulation. The Study of airborne PCM telemtry system contribute to develop a device which can acquire various technical data of newly developing flying vehicles by remote measurement. The performance of the proposed system has been verified through a seguence of tests.

  • PDF

Decimation Chain Modeling for Dual-Band Radio Receiver and Its Operation for Continuous Packet Connectivity

  • Park, Chester Sungchung;Park, Sungkyung
    • Journal of information and communication convergence engineering
    • /
    • v.13 no.4
    • /
    • pp.235-240
    • /
    • 2015
  • A decimation chain for multi-standard reconfigurable radios is presented for 900-MHz and 1,900-MHz dual-band cellular standards with a data interpolator based on the Lagrange method for adjusting the variable data rate to a fixed data rate appropriate for each standard. The two proposed configurations are analyzed and compared to provide insight into aliasing and the signal bandwidth by means of a newly introduced measure called interpolation error. The average interpolation error is reduced as the ratio of the sampling frequency to the signal BW is increased. The decimation chain and the multi-rate analog-to-digital converter are simulated to compute the interpolation error and the output signal-to-noise ratio. Further, a method to operate the above-mentioned chain under a compressed mode of operation is proposed in order to guarantee continuous packet connectivity for inter-radio-access technologies. The presented decimation chain can be applied to LTE, WCDMA, GSM multi-mode multi-band digital front-end which will ultimately lead to the software-defined radio.

Breast and Cervical Cancer Screening in Women Referred to Urban Healthcare Centers in Kerman, Iran, 2015

  • Ahmadipour, Habibeh;Sheikhizade, Sahar
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.sup3
    • /
    • pp.143-147
    • /
    • 2016
  • Breast and cervical cancers are among leading causes of morbidity and mortality in women worldwide. Regular screening is very important for early detection of these cancers, but studies indicate low rates of screening participation. In this survey we studied the rate of screening participation among women 18-64 years old referred to urban health centers in Kerman, Iran in 2015. A cross-sectional study was carried out on 240 women who were selected using a multistage sampling method. Data collected using a questionnaire covered demographics and questions about common cancer screening status in women. Analysis was by SPSS 19. The mean age of participants was $31.7{\pm}7$. Most (97.1%) were married, housewives (83.3%), had high school diploma (43.8%) and a monthly income more than ten million Rls. The frequency of the Pap test performance was higher in women who were employed and with a university degree (p<0.05). The frequency of mammography performance in women over 40 years was also higher in women with university degree (p<0.05). There was no statistically significant difference in the frequency of pelvic examination, and self and clinical breast examinations based on education, household income and employment (p>0.05). Our study found that the rate of screening participation among women is low. Investigation of the barriers, increasing the awareness of women about the importance and advantages of screening and also more incentives for health personnel especially family physicians to pay more attention to preventive programs could be effective.

Performance Analysis of DMF Acquisition System in Frequency-Selective Rayleigh Fading Channel (주파수 선택적 레일리 페이딩 채널에서의 DMF 초기동기 장치의 성능분석)

  • 김성철;이연우;조춘근;박형근;차균현
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.7B
    • /
    • pp.1351-1360
    • /
    • 1999
  • In frequency selective channels, conventional PN code acquisition schemes are not ideal candidates. This is because they are primarily designed for the AWGN channel. In this paper, a direct-sequence spread-spectrum(DSSS) PN code acquisition system based on digital matched filtering (DMF) with automatic threshold control(ATC) algorithm is presented and analyzed with regards to probability of detection and probability of false alarm. These two important probabilities, the probability of detection ($P_D$) and the probability of false alarm ($P_{FA}$) are derived and analyzed in considering Doppler shift, sampling rate, mean acquisition time, and PN chip rate in frequency selective Rayleigh fading channel when using serial-search method as detection technique. From computer simulation results of a DMF acquisition system model, it is shown that the performance of the acquisition system using ATC algorithm is better than that of constant threshold system.

  • PDF

Vacuum Assisted Auto-Lancing Technique for Capillary Blood Sampling on the Forearm with Minimized Pain (전완부위 최소통증 채혈을 위한 진공 자동 채혈기법)

  • Park Mi Sook;Park Kyung Soon;Kim Kyung Ah;Jun Myung Hee;Kim Tae Im;Lee Tae Soo;Cha Eun Jong
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.557-563
    • /
    • 2004
  • A new vacuum assisted auto-lancing technique is proposed to minimize pain. Specially designed lancing device was introduced, which applied -100mmHg right after skin puncture on the forearm. Sampled blood volumes were measured in 58 normal females. Mean volume of 464 samples was approximately 2.6$\muL$ and the frequency of more than 0.5$\muL$ was 86%. Thus the success rate of blood sugar test should also be the same when using modern glucose meters capable of testing with only 0.3~0.5$\muL$ of capillary blood. When pain scores were quantitatively evaluated by the visual pain measure, only 23% pain of the traditional finger sampling was experienced, demonstrating that capillary blood sampling was performed on the forearm with almost no pain. The present technique reduced pain to a great degree, though resampling might be unavoidable due to 14% of test failure rate estimated for modern glucose meters. However, minimized pain makes the present technique of great convenience for diabetic patients who need blood sampling a few times a day.