• Title/Summary/Keyword: sampling points

Search Result 638, Processing Time 0.029 seconds

Impact of urbanization on Nwaorie and Otamiri Rivers in Owerri, Imo State, Nigeria

  • Ogbomida, Emmanuel T.;Emeribe, Chukwudi N.
    • Advances in environmental research
    • /
    • v.2 no.2
    • /
    • pp.119-129
    • /
    • 2013
  • The study examined the effect of urbanization on the water quality of Nwaorie and Otamiri Rivers in Owerri metropolis, Imo State, South-East Nigeria. Water samples were collected from Nwaorie and Otamiri Rivers from four sampling stations up and down stream. Water parameters analyzed using standard procedures were: color, turbidity, temperature, pH, total hardness, total solids, metals (Iron and magnesium), anions (nitrate and ammonia) and Fecal coliform. Results showed increased levels of coloration, iron, ammonia, turbidity and fecal coliform which exceeded the World Health Organization (WHO) permissible limits for drinking water. Increase in these parameters indicated influx of industrial effluent from the nearby industries and indiscriminate disposal of wastes at the bank of the rivers. Application of ANOVA showed various degree of variation in pollutants levels between the two rivers and at different sampling points. River Nwaorie was observed to be more impacted than River Otamiri. High values of iron observed from the study could be deleterious to human health if the river water is consumed without treatment. The study, therefore, recommended proper waste management and disposal as well as effluent treatments in Owerri municipal against pollution of surface water.

Digital Scan Converter Algorithm for Ultrsound Sector Scanner (초음파 섹터 스캐너를 위한 디지털 스캔 변환 기법)

  • 김근호;오정환
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.4
    • /
    • pp.469-478
    • /
    • 1996
  • In the conventional digital ultrasound scanner, the reflected signal is sampled either in polar coordinates of R-$\theta$ method, or in Cartesian coordinates of uniform ladder algorithm (ULA). The R-$\theta$ scan method necessitates a coordinate transform process which makes hardware complex in comparison with ULA scan mrthoA In spite of this complexity, R-$\theta$ method has a good resolution in ultrasonographic (US) image, since scan direction of the US imaging is a radial direction. In this paper, a new digital scan converter is proposed, which is named the radius uniform ladder algorithm (RULA). The RULA has the rome scan direction as the US scanning in the radial direction and as the display space in the $\theta$ direction. In tllis new approach, sampled points we uniformly distributed in each horizontal line i.n well as in each radial ray so that the data are displayed in the Cartesian coordinates by the 1-D interpolation process. The propped algorithm has an uniform resolution in the periphery and the center field in comparison with equi-angle ULA and equi-interval ULA. To extend the scan angle, concentric square raster sampling (CSRS) is adopted with reduction of discontinuities on the junctions between horizontal scan and vertical scan. The discontinuities are reduced by using the hmction filtering along the $\theta$ direction.

  • PDF

Soil sampling plan design of key facilities for denuclearization based on data quality objective process

  • Jeon, Yeoryeong;Kim, Yongmin
    • Nuclear Engineering and Technology
    • /
    • v.54 no.10
    • /
    • pp.3788-3794
    • /
    • 2022
  • The possibility of denuclearization of the Korean Peninsula has been continuously debated, and the initiative participation of the Republic of Korea has necessitated preemptive measures against neighboring countries. In this study, we present a proposal for formulating a site survey plan when the amount of site information provided is insufficient and the accuracy of the information is not guaranteed. Considering a case wherein "a soil sample analysis is used to determine the presence or absence of nuclear activity" in a radiochemical laboratory, which is a typical key facility for denuclearization, the optimal soil sample collection plan is designed based on international guidelines and public information. In the event of denuclearization, a scenario that is not based on the expertise of the sample collector is set, and the data quality objective (DQO) process is applied to ensure reality. Consequently, the primary sample collection points can be derived in consideration of accessibility, and the sample collection scale can be adjusted according to the cost. By applying the DQO process to ensure sample representativeness and reality, reliable and resource-efficient soil sample collection can be achieved in radiochemical laboratories and other denuclearization facilities.

Airborne Nicotine Concentrations in Harvesting and the Processing of Tobacco Leaves (담뱃잎 수확 및 가공 과정에서 공기 중 니코틴농도)

  • Park, Sung-Jun;Kim, Jong-Seuk;Kim, Jik-Su;Lee, Kwan;Lim, Hyun-Sul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.20 no.1
    • /
    • pp.47-52
    • /
    • 2010
  • Green tobacco sickness (GTS) is known as an occupational disease among tobacco harvesters, and a form of acute nicotine intoxication by the absorption of nicotine through the skin from the wet green tobacco plant. On the assumption that GTS may occur by inhalation as well as absorption of nicotine, we measured the airborne nicotine concentration in tobacco field and the processing room of tobacco leaves. We measured the airborne nicotine concentrations in the tobacco field and processing room between 13 and 30 July 2008. All sampling and analyses of airborne nicotine were conducted according to the manual of analytic methods of NIOSH 2551, and we sampled 2 times at 11 points in the tobacco field by area sampling. The sampling in the processing room of tobacco leaves was conducted at 3 points, and earlymorning dew was collected from the tobacco by wringing the moisture into specimen bottles. The airborne nicotine concentration [geometric mean (geometric standard deviation)] in the tobacco field in the P.M. was higher [49.2 mg/$m^3$ (1.3)] than the A.M. concentration [43.4 mg/$m^3$ (1.4)]. Similarly, the nicotine concentration in the processing room of tobacco leaves was 224.4 mg/$m^3$ (1.2), and the concentration of nicotine in the dew was 64.7 mg/${\ell}$ (1.7). Based on our results, the airborne nicotine concentration in the tobacco field and the processing room of tobacco leaves were 100 and 400 times higher than the occupational recommended values (TLV-TWA of 0.5 mg/$m^3$), respectively. In the future, it is hoped that epidemiologic studies and environmental measurements will be conducted for GTS which occurs by inhalation of nicotine. If GTS is confirmed to occur by inhalation of nicotine, respiratory and dermal protective equipment must be distributed.

Improved VFM Method for High Accuracy Flight Simulation (고정밀 비행 시뮬레이션을 위한 개선 VFM 기법 연구)

  • Lee, Chiho;Kim, Mukyeom;Lee, Jae-Lyun;Jeon, Kwon-Su;Tyan, Maxim;Lee, Jae-Woo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.49 no.9
    • /
    • pp.709-719
    • /
    • 2021
  • Recent progress in analysis and flight simulation methods enables wider use of a virtual certification and reduces number of certification flight tests. Aerodynamic database (AeroDB) is one of the most important components for the flight simulation. It is composed of aerodynamic coefficients at a range of flight conditions and control deflections. This paper proposes and efficient method for construction of AeroDB that combines Gaussian Process based Variable Fidelity Modeling with adaptive sampling algorithm. A case study of virtual certification of a F-16 fighter is presented. Four AeroDB were constructed using different number and distribution of high-fidelity data points. The constructed database is then used to simulate gliding, short pitch, and roll response. Compliance with certification regulations is then checked. The case study demonstrates that the proposed method can significantly reduce number of high-fidelity data points while maintaining high accuracy of the simulation.

A study on the determination of substrata using the information of exponential response rate by simulation studies (모의실험을 기반으로 지수형 응답률 보정을 위한 세부 층 결정에 관한 연구)

  • Min, Joo-Won;Shin, Key-Il
    • The Korean Journal of Applied Statistics
    • /
    • v.31 no.5
    • /
    • pp.621-636
    • /
    • 2018
  • Research on the application of informative sampling technique has been conducted in order to reduce the influence of non-response. Chung and Shin (Korean Journal of Applied Statistics, 30, 993-1004, 2017) showed that the estimation accuracy improved when using exponential response rate information for the parameter estimation if the distribution of errors included in the super population model follows normal distribution. However this method divides the stratum into equally spaced substrata to obtain the sample weight of the informative sampling technique and shows that the accuracy of the estimation improves as the number of substrata increases. In this study, with the given number of total sample size, the optimal substratum boundary points are calculated using equal space, quantile, and LH algorithm; consequently, the results using those methods are compared through simulation. We also studied the criteria to determine the number of substrata and substratum boundaries that can be used in practice with various types of auxiliary variable distributions.

MCMC Algorithm for Dirichlet Distribution over Gridded Simplex (그리드 단체 위의 디리슐레 분포에서 마르코프 연쇄 몬테 칼로 표집)

  • Sin, Bong-Kee
    • KIISE Transactions on Computing Practices
    • /
    • v.21 no.1
    • /
    • pp.94-99
    • /
    • 2015
  • With the recent machine learning paradigm of using nonparametric Bayesian statistics and statistical inference based on random sampling, the Dirichlet distribution finds many uses in a variety of graphical models. It is a multivariate generalization of the gamma distribution and is defined on a continuous (K-1)-simplex. This paper presents a sampling method for a Dirichlet distribution for the problem of dividing an integer X into a sequence of K integers which sum to X. The target samples in our problem are all positive integer vectors when multiplied by a given X. They must be sampled from the correspondingly gridded simplex. In this paper we develop a Markov Chain Monte Carlo (MCMC) proposal distribution for the neighborhood grid points on the simplex and then present the complete algorithm based on the Metropolis-Hastings algorithm. The proposed algorithm can be used for the Markov model, HMM, and Semi-Markov model for accurate state-duration modeling. It can also be used for the Gamma-Dirichlet HMM to model q the global-local duration distributions.

Evaluating Reliability of Rooftop Thermal Infrared Image Acquired at Oblique Vantage Point of Super High-rise Building (초고층건물의 사각조망에서 촬영된 지붕표면 열화상의 신뢰도 평가)

  • Ryu, Taek-Hyoung;Um, Jung-Sup
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.5
    • /
    • pp.51-59
    • /
    • 2013
  • It is usual to evaluate the performance of the cool roof by measuring in-site rooftop temperature using thermal infra-red camera. The principal advantage of rooftop thermal infrared image acquired in oblique vantage point of super high-rise building as a remote sensor is to provide, in a cost-effective manner, area-wide information required for a scattered rooftop target with different colors, utilizing wide view angle and multi-temporal data coverage. This research idea was formulated by incorporating the concept of traditional remote sensing into rooftop temperature monitoring. Correlations between infrared image of super high-rise building and in-situ data were investigated to compare rooftop surface temperature for a total of four different rooftop locations. The results of the correlations analyses indicate that the rooftop surface temperature by the infrared images of super high-rise building alone could be explained yielding $R^2$ values of 0.951. The visible permanent record of the oblique thermal infra-red image was quite useful in better understanding the nature and extent of rooftop color that occurs in sampling points. This thermal infrared image acquired in oblique vantage point of super high-rise made it possible to identify area wide patterns of rooftop temperature change subject to many different colors, which cannot be acquired by traditional in-site field sampling. The infrared image of super high-rise building breaks down the usual concept of field sampling established as a conventional cool roof performance evaluation technique.

Optimal Placement of Sensors for Damage Detection in a Structure and its Application (구조물의 손상탐지를 위한 센서 위치 최적화 및 적용)

  • 박수용
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.7 no.4
    • /
    • pp.81-87
    • /
    • 2003
  • In this paper, the feasibility of using Shannon's sampling theorem to reconstruct exact mode shapes of a structural system from a limited number of sensor points and localizing damage in that structure with reconstructed mode shapes is investigated. Shannon's sampling theorem for the time domain is reviewed. The theorem is then extended to the spatial domain. To verify the usefulness of extended theorem, mode shapes of a simple beam are reconstructed from a limited amount of data and the reconstructed mode shapes are compared to the exact mode shapes. On the basis of the results, a simple rule is proposed for the optimal placement of accelerometers in modal parameter extraction experiments. Practicality of the proposed rule and the extended Shannon's theorem is demonstrated by detecting damage in laboratory beam structure with two-span via applying to mode shapes of pre and post damage states.

Precise System Models using Crystal Penetration Error Compensation for Iterative Image Reconstruction of Preclinical Quad-Head PET

  • Lee, Sooyoung;Bae, Seungbin;Lee, Hakjae;Kim, Kwangdon;Lee, Kisung;Kim, Kyeong-Min;Bae, Jaekeon
    • Journal of the Korean Physical Society
    • /
    • v.73 no.11
    • /
    • pp.1764-1773
    • /
    • 2018
  • A-PET is a quad-head PET scanner developed for use in small-animal imaging. The dimensions of its volumetric field of view (FOV) are $46.1{\times}46.1{\times}46.1mm^3$ and the gap between the detector modules has been minimized in order to provide a highly sensitive system. However, such a small FOV together with the quad-head geometry causes image quality degradation. The main factor related to image degradation for the quad-head PET is the mispositioning of events caused by the penetration effect in the detector. In this paper, we propose a precise method for modelling the system at the high spatial resolution of the A-PET using a LOR (line of response) based ML-EM (maximum likelihood expectation maximization) that allows for penetration effects. The proposed system model provides the detection probability of every possible ray-path via crystal sampling methods. For the ray-path sampling, the sub-LORs are defined by connecting the sampling points of the crystal pair. We incorporate the detection probability of each sub-LOR into the model by calculating the penetration effect. For comparison, we used a standard LOR-based model and a Monte Carlo-based modeling approach, and evaluated the reconstructed images using both the National Electrical Manufacturers Association NU 4-2008 standards and the Geant4 Application for Tomographic Emission simulation toolkit (GATE). An average full width at half maximum (FWHM) at different locations of 1.77 mm and 1.79 mm are obtained using the proposed system model and standard LOR system model, which does not include penetration effects, respectively. The standard deviation of the uniform region in the NEMA image quality phantom is 2.14% for the proposed method and 14.3% for the LOR system model, indicating that the proposed model out-performs the standard LOR-based model.