• Title/Summary/Keyword: sample pretreatment

Search Result 229, Processing Time 0.03 seconds

Removal of Natural Organic Matter using Potassium ferrate(VI) (Potassium ferrate(VI)를 이용한 자연유기물질 제거)

  • Lim, Mi-Hee;Kim, Myoung-Jin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.29 no.12
    • /
    • pp.1337-1344
    • /
    • 2007
  • In this research, we synthesized potassium ferrate(VI) acting as an oxidant, disinfectant, and coagulant, and used it to treat natural organic matter(NOM, HA and FA) in river water. The removal efficiencies obtained by $UV_{254}$ ranged from 20.7 to 73.6% for 10 mg/L HA and from 52.6 to 77.5% for 10 mg/L FA in Nakdong river sample as the ferrate dose varied from 2 to 46 mg/L(as Fe). However, the removal efficiencies by TOC analysis ranged from 0 to 20.3% for HA and from 0 to 26.6% for FA at the same ferrate doses. The removal efficiencies of NOM increased either with decreasing pH or with increasing temperature. The removal efficiency of HA by ferrate was comparable to those by traditional coagulants such as $Al_2(SO_4)_3{\cdot}18H_2O$, $FeSO_4{\cdot}7H_2O$, and FeO(OH). The reaction between ferrate and HA reached a steady state within 60 seconds, showing first-order with respect to the reaction time. The removal efficiencies of HA by traditional coagulants were improved by pretreatment of HA using a small amount of ferrate.

Factors Affecting the Minimum Detectable Activity of Radioactive Noble Gases (방사성 노블가스 측정을 위한 최소검출방사능 산출의 조절인자)

  • Park, Ji-young;Ko, Young Gun;Kim, Hyuncheol;Lim, Jong-Myoung;Lee, Wanno
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.16 no.3
    • /
    • pp.301-308
    • /
    • 2018
  • Anthropogenic radioactive noble gases formed by nuclear fission are significant indicators used to monitor the nuclear activity of neighboring countries. In particular, radioactive xenon, owing to its abundant generation and short half-life, can be used to detect nuclear testing, and radioactive krypton has been used as a tracer to monitor the reprocessing of nuclear fuels. Released radioactive noble gases are in the atmosphere at infinitesimal amounts due to their dilution in the air and their short half-life decay. Therefore, to obtain reliable and significant data when performing measurement of noble gases in the atmosphere, the minimum detectable activity (MDA) for noble gases should be defined as low as possible. In this study, the MDA values for radioactive xenon and krypton were theoretically obtained based on the BfS-IAR system by collecting both noble gases simultaneously. In addition, various MDA methods, confidence level and analysis conditions were suggested to reduce and optimize MDA with an assessment of the factors affecting MDA. The current investigation indicated that maximizing the pretreatment efficiency and performance maintenance of the counter were the most important aspects for Xe. In the case of Kr, since sample activities are much higher than those of Xe, it is possible to change the target MDA or to simplification of the analysis system.

Development of a Method for Detecting Iodide and Chloride Ions in Infant Formula using an Ion Selectivity Electrode (이온선택성 전극법을 이용한 조제분유중의 염소 및 요오드 이온함량 분석방법 연구)

  • Ko, Jin-Hyouk;Kwak, Byung-Man;Ahn, Jang-Hyuk;Jeon, Tae-Hong
    • Food Science of Animal Resources
    • /
    • v.28 no.3
    • /
    • pp.301-305
    • /
    • 2008
  • This study was carried out to develop an accurate and rapid analysis method to measure the contents of iodide and chloride in infant formula using an ion selectivity electrode. The infant formula SRM 1846 (Standard Reference Material 1846, NIST, USA) was used as a CRM (Certified reference material). Samples were dissolved in water with 3% acetic acid and filtered through filter paper and adjusted to pH 7.0 with 0.1N NaOH. At pH 7.0, the iodide content of the CRM was $1.04{\pm}0.03\;mg/kg$ compared to the specification of $1.11{\pm}0.1\;mg/kg$ of CRM, and the recovery was $93.7{\pm}2.7%$. The chloride content was $5114.3{\pm}240\;mg/kg$ compared to the specification of $4,920{\pm}300mg/kg$ of CRM, and the recovery was $103.9{\pm}4.9%$. Ion selectivity electrodes could be successful1y used to determine the concentration of iodide and chloride ions in infant formula by a simple and rapid pretreatment of sample matrixes.

Fracture Analysis of Implant Components using Scanning Electron Microscope : Part II - Implant Retaining Screw (임플란트 구성요소의 파절면에 관한 주사전자현미경적 연구 : Part II - 임플란트 유지나사)

  • Lim, Kwang-Gil;Kim, Dae-Gon;Cho, Lee-Ra;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.4
    • /
    • pp.373-388
    • /
    • 2010
  • Fracture causes serious problems in many instance of prosthetic failures. But it is hard to find the definite causes when fractures occur. Fractography encompasses the examination of fracture surfaces that contain features resulting from the interaction of the advancing crack with the microstructure of the material and the stress fields. All fractured specimens(implant retaining screw) retrieved from Gangneung-Wonju national university dental hospital for 3 years(from 2007 to 2009). After pretreatment of samples, the scanning electon microscope were used for surface examination and fracture analysis. In case of most of the fractured specimens, fracture took place by fatigue fracture and fractured surface represents fatigue striation. Fatigue striation indicate the progression of the crack front under cyclic loading, are characteristic of stage 2 crack growth. The site of crack initiation and stage 1 crack growth were not easily identified in any of the failure, presumably because of the complex microstructural features of the polycrystalline sample. In case of fractured by overload, dimpled or cleavage surface were observed. Using the interpretation of characteristic markings(ratchet mark, fatigue striation, dimple, cleavage et al) in fracture surfaces, failure events containing the crack origin, crack propagation, material deficiency could be understand. Using the interpretation of characteristic markings in fracture surfaces, cause and mechanism of fractures could be analyzed.

Effects of Heat Treatment and Extraction Method on Antioxidant Activity of Several Medicinal Plants (열처리와 추출방법에 따른 몇 가지 약초의 항산화 활성)

  • Jang, Gwi-Yeong;Kim, Hyun-Young;Lee, Sang-Hoon;Kang, Yu-Ri;Hwang, In-Guk;Woo, Koan-Sik;Kang, Tae-Soo;Lee, Jun-Soo;Jeong, Heon-Sang
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.41 no.7
    • /
    • pp.914-920
    • /
    • 2012
  • We investigated the effects of heat treatment and extraction method on the antioxidant activities of five medicinal plants: Cyperus rotundus, Eucommia ulmoides, Bupleurum falcatum, Achyranthes japonica Nakai, and Akebia quinata. Extraction was performed with only ultrasound, ultrasound after heating at $130^{\circ}C$ for 2 hours, and reflux extraction with distilled water. The phenolic contents of reflux extraction and ultrasound extraction after heating were higher than only ultrasound extraction, and ultrasound extraction after heating samples was higher than reflux extraction except for Eucommia ulmoides and Cyperus rotundus. Total flavonoid content was higher in reflux and ultrasound extraction after heating samples than only ultrasound extraction, except for Cyperus rotundus. ABTS radical scavenging activity was higher in reflux extraction and ultrasound extraction after heating a sample, than only ultrasound extraction. DPPH radical scavenging activity was higher in reflux extraction except for Achyranthes japonica Nakai and Akebia quinata. The reducing power of ultrasound extraction after heating was higher with Achyranthes japonica Nakai. From the results of this study, we can expect to increase the antioxidant activity of medicinal plant extracts by applying suitable extraction and pretreatment conditions on the type of medicinal plant.

Preliminary study on geochemical elements concentration changes in coral skeleton from Chuuk, Micronesia (마이크로네시아 축 경산호 골격의 지화학 원소 농도에 대한 예비연구)

  • Hyun, Sang-Min;Park, Heung-Sik;Kim, Su-Hyun;Kim, Han-Jun;Jang, Suk
    • The Korean Journal of Quaternary Research
    • /
    • v.22 no.1
    • /
    • pp.1-12
    • /
    • 2008
  • We investigated metal concentrations and oceanic environment changes that have occurred over the past several years by studying the hard coral Porites lutea, which inhabits tropical and subtropical areas. Soft X-radiographs clearly showed distinctive annual bands within 71 mm coral sample, which reflect changes in the oceanic environment over this period. There were large fluctuations in the major and minor element concentrations. Considering the physicochemical partition coefficient, some elements accumulated in the aragonite matrix in a mechanical manner, while others were affected by environmental factors. The concentrations of some heavy metals varied over a wide range, implying local environmental effects. The variation of Sr/Ca and Mg/Ca in coral skeleton clearly showed large-scale fluctuation over the specific intervals, implying environmental changes during this period. The concentrations of heavy metals also show high fluctuations, and roughly accord with Mg/Ca variation. In addition, Cu and Zn seem to show cyclicity-like peaks, coincide with Mg/Ca variation over the specific intervals. Such variation might be related to local pollution and oceanographic changes. More detailed investigation is necessary, including the pretreatment of coral skeleton sediment.

  • PDF

Evaluation of Exposure Indicators for Plants by Silicon Tetrachloride Release (사염화규소 누출사고지점 주변 식물에 대한 노출지표 평가)

  • Park, Jae-Seon;Kim, Jee-Young;Kim, Myeong-Ock;Park, Hyun-Woo;Chung, Hyen-Mi;Choi, Jong-Woo
    • Korean Journal of Environmental Agriculture
    • /
    • v.36 no.4
    • /
    • pp.288-292
    • /
    • 2017
  • BACKGROUND: Silicon tetrachloride reacts with moisture in the atmosphere to generate hydrogen chloride, which affects the environment. Since silicon tetrachloride and its by-products are dispersed in the atmosphere in a short time after the silicon tetrachloride release into the atmosphere, it is difficult to directly assess the extent of environmental impact. In the present study, the exposure test of silicon tetrachloride or hydrogen chloride was examined in order to establish the criterion of the range affected by the silicon tetrachloride release, and the actual crops in the area exposed to silicon tetrachloride leakage were analyzed. METHODS AND RESULTS: For the experiment of exposure to silicon tetrachloride or hydrogen chloride, the leaves of red-pepper and corn were used in glass sealed containers. In the actual accident area, 59 samples from 10 different kinds of crops were collected. The pretreatment of the sample was performed by freezing and grinding, and then extracted using distilled water. The pH and concentration of chloride ($Cl^-$) ion of the extracted solution were measured using pH meter and ion chromatograph, respectively. CONCLUSION: Exposure to silicon tetrachloride caused visible damage, increasing the concentration of chloride ion, and decreasing the pH as well as hydrochloric acid. In the actual crops of the affected area, the tendency was the same as the result of the laboratory test, and the range of influence could be estimated through the concentration of $Cl^-$ ion over 2,000 mg/kg, and the correlation evaluation between the concentration of $Cl^-$ and pH. Therefore, the concentration of $Cl^-$ ion and the correlation between $Cl^-$ and pH would be considered as the factors to estimate the influence range of silicon tetrachloride release.

Static Supercritical Fluid Extraction of PCBs from Soil Matrix (정적 초임계유체 방식에 의한 토양 중의 PCBs 추출)

  • Ryoo, Keon-Sang;Lee, Won-Kyoung;Hong, Yong-Pyo;Oh, In-Gyung;Kim, Yong-Gyun
    • Journal of the Korean Chemical Society
    • /
    • v.47 no.6
    • /
    • pp.578-584
    • /
    • 2003
  • Polychlorinated biphenyls (PCBs) known as environmental contaminants in soil were analyzed by the soil pollution standard process test and the static supercritical $CO_2$ extraction mode. It was shown that the percent average recoveries of PCBs by the soil pollution standard process test were ranged in 25-35% and the corresponding standard deviations were above 10%. In contrast, the percent average recoveries of PCBs by the static supercritical $CO_2$ extraction mode were 2-2.5 times higher and standard deviations were within 7%. These results indicate that static supercritical $CO_2$ extraction mode may be a useful alternative to sample pretreatment certified by the soil pollution standard process test. The increasing supercritical $CO_2$ pressure from 1130 psi to 1996 psi at $40^{\circ}C$ enhanced the recovery of all PCB congeners from soil. However, at same Tc and Pc, the equilibrium time (5 versus 60 minutes) had no effect on the recovery of each PCB congener. Finally, similar PCB recoveries were obtained under the same extraction condition, regardless of the molecular weight and structure (coplanar versus non-coplanar) of PCB congeners.

Effect of Aging Time on the Sonic Conductivity of $PEO_8LiClO_4/Al_2O_3$ Composite Polymer Electrolytes ($PEO_8LiClO_4/Al_2O_3$ 복합 고분자 전해질에서의 이온 전도도의 노화 현상)

  • Choi, Byoung-Koo;Park, Young-Hwan
    • Polymer(Korea)
    • /
    • v.31 no.3
    • /
    • pp.263-268
    • /
    • 2007
  • Most of current works on the PEO-salt electrolytes has been focused on the enhancement of ionic conductivity with an addition of nano-ceramic fillers, but the significant drop of the conductivity with storage time is still in question and has been frequently overlooked. The conductivity drop with aging time has been assumed to come from the incorporation of ceramic particles. However, according to authors, the reported high-temperature values of the conductivity of pure $PEO_8LiCIO_4$ electrolytes are nearly in agreements, but the low temperature values are in great discrepancy reaching up to 10000 times. It indicates that the conductivity at ambient temperature is greatly dependent on the thermal history and sample preparations. In this paper, we showed that the ionic conductivities of both $PEO_8LiCIO_4$ and $PEO_8LiClO_4/Al_2O_3$ polymer electrolytes are strongly dependent on the thermal pretreatment and aging time. The conductivity drop with aging time of both ceramic-free and ceramic composite electrolytes has been measured to be nearly parallel. We showed that the conductivity relaxation with aging time is inherent irrespective of the incorporation of nano-ceramic fillers, since the PEO electrolytes at ambient temperature are in two-phase nature being in non-equilibrium state, never reaching completion.

Purification of IgG1 Type Mouse Monoclonal Antibodies with DEAE-Trisacryl Chromatography (DEAE-Trisacryl 크로마토그래피법에 의한 IgG1 Type 쥐 단일클론 항체의 분리정제)

  • 최태부;정용근
    • Microbiology and Biotechnology Letters
    • /
    • v.16 no.5
    • /
    • pp.335-342
    • /
    • 1988
  • An anion exchange chromatography was employed for the purification of mouse monoclonal antibodies from ascitic fluid and in vitro cultivation media. After cultivation of hybridomas, Alps 25-3, HCGK, A4W, and KW, producing IgG1, the culture supernatants were harvested by centrifugation, precipitated with 50-60% ammonium sulfate, and dialyzed against 0.025 M Tris-HCI buffer (pH 8.2). Then the dialyzed samples were loaded into a DEAE-Trisacryl M anion exchange column. Monoclonal antibodies bound to the DEAE-Trisacryl M were eluted with 0.025 M Tris-HCI buffer (pH 8.2) containing 30-40 mM NaCl. In ammonium sulfate precipitation, the recovery of the monoclonal antibody was shown to be 90% and 84% from in vitro culture media containing 10% and 2% fetal bovine serum, respectively. On the other hand, the pretreatment by ultrafiltration enhanced the yield up to 91% whereas the purity was lower than that by ammonium sulfate treatment. Subsequently, in the DEAE-Trisacryl M chromatographic separation, the purities and recoveries of all the monoclonal antibodies from both the in vitro culture supernatants and ascitic fluids were 70-80% and 65% respectively. The monoclonal antibody, Alps 25-3 could be further purified with a purity of 95% through an immunoadsorbent chromatography.

  • PDF