• Title/Summary/Keyword: sample line

Search Result 887, Processing Time 0.024 seconds

VCO fabrication using Microstrip Line operating at the UHF frequency band (UHF대역에서 동작하는 마이크로스트립라인을 이용한 VCO 제작)

  • Rhie, Dong Hee;Jung, Jin-Hwee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.55-58
    • /
    • 2001
  • In this paper, we present the results of the design and fabrication of the VCO(Voltage controlled Oscillator) using RF circuit simulator GENESYS and electromagnetic field simulator EMpower Frequency range is fabricated VCO is 850 MHz ~ 950 MHz, which is used Colpitts Circuit. the fabricated VCO is consisted of resonator, oscillator and MSL(Microstrip Line) is used in LC tuning circuit.(operated by negative feedback) MSL(Microstrip Line), Varactor(Plastic package), low noise TR(SOT-23), chip inductor(1608), chip capacitor(1005), chip resistance(1005). 1005 type is used for sample fabrication of VCO. In the fabrication process, circuit pattern is screen printed on the alumina substrates of over 99.9% purity. Center frequency of the sample VCO is 850MHz at $V_T=1.5V$, while the simulated value was 1.0GHz at $V_T=1.5V$. Variable frequency range of the sample is 860~950MHz in contrast to the 1068~1100MHz of the simulated values.

  • PDF

VCO fabrication using Microstrip Line operating at the UHF frequency band (UHF대역에서 동작하는 마이크로스트립라인을 이용한 VCO 제작)

  • Rhie, Dong-Hee;Jung, Jin-Hwee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.153-156
    • /
    • 2001
  • In this paper, we present the results of the design and fabrication of the VCO(Voltage controlled Oscillator) using RF circuit simulator GENESYS and electromagnetic field simulator EMpower Frequency range is fabricated VCO is 850 MHz ~ 950 MHz, which is used Colpitts Circuit. the fabricated VCO is consisted of resonator, oscillator and MSL(Microstrip Line) is used in LC tuning circuit.(operated by negative feedback) MSL(Microstrip Line), Varactor(Plastic package), low noise TR(SOT-23), chip inductor(1608), chip capacitor(1005), chip resistance(1005). 1005 type is used for sample fabrication of VCO. In the fabrication process, circuit pattern is screen printed on the alumina substrates of over 99.9% purity. Center frequency of the sample VCO is 850MHz at $V_T$=1.5V, while the simulated value was 1.0GHz at $V_T$=1.5V. Variable frequency range of the sample is 860~950MHz in contrast to the 1068~1100MHz of the simulated values.

  • PDF

Recalibrating virial black hole mass estimators

  • Park, Da-Woo;Woo, Jong-Hak
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.2
    • /
    • pp.63.1-63.1
    • /
    • 2011
  • In understanding AGN physics, it is fundamental to determine black hole masses. Based on the gas kinematics of the broad-line region, black hole masses can be derived from the product of the width of the broad emission lines and the continuum/line luminosities. For a sample of 37 intermediate-luminosity AGN at z~0.4, we obtained high quality spectra (S/N~100) using the Low Resolution Imaging Spectrometer(LRIS) at the KECK telescope, in order to calibrate various black hole mass estimators based on the Mg II (2798A), the $H{\beta}$ (4861A), and the $H{\alpha}$ (6563$\bar{A}$) emission lines. Based on our multicomponent fitting analysis, we subtract continuum, FeII emission, and host galaxy starlight, reducing systematic errors in measuring emission line widths. Combining low S/N SDSS spectra with our high S/N keck spectra, we determine a set of ~30 black hole masses of the sample for each emission line. Then by comparing various sets of black hole masses, we internally calibrate each mass estimators and investigate uncertainties and limitations of each mass estimator.

  • PDF

On-line SPE-HPLC Method using Alumina Filtering to Selectively Extract Phenolic Compounds from Environmental Water

  • Lee, Sung-Kwang
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.12
    • /
    • pp.3755-3759
    • /
    • 2010
  • A on-line SPE (solid phase extraction)-HPLC preconcentration method was developed for the determination of phenolic compounds at trace levels in environmental water sample. XAD-4 and Dowex 1-X8 were used as sorbent in the on-line SPE-HPLC method for the selective enrichment of nine phenolic compounds, which are included in the priority pollutants list of the US EPA. Also alumina prefiltering considerably reduced the amount of interfering peaks due to humic substances that could accumulated due to the preconcentration step and prevent quantification of polar phenolic compounds in environmental water samples. This method was used to determine the phenolic compounds in tap and river water and superiority to the US EPA 625 method in its enrichment factor, pretreatment time, recoveries, and detection limit. The limits of detection were in the range of $0.3-0.9\;{\mu}g/L$ in tap water sample.

A Study on Sample Size Dependence of Ferromagnetic Resonance in Polycrystalline Magnesium Ferrites (마그네슘 페라이트에서 강자성 공명의 시료 크기 의존성 연구)

  • 한기태;백종규
    • Journal of the Korean Ceramic Society
    • /
    • v.32 no.2
    • /
    • pp.163-170
    • /
    • 1995
  • Sample size effect on ferromagnetic resonance (FMR) in polycrystalline MgFe2O4 has been investigated. The signal intensity (SI), resonance field (Hres) and line width (ΔH) were found to increase proportionally to r3 with the increase of sample radius. The r3-depencence of SI means the complete penetration of rf-field into the sample, and the broadening of ΔH due to the sample size appears to be closely related to the amount of scattering sources like pores. Meanwhile, the values of Hres (0) and ΔH (0) obtained by extrapolating the data of Hres (r) and ΔH (r) measured at several sizes to r=0, were in good agreement with those calculated using the Schlomann's equations for internal field and ΔH, respectively. This result indicates that the discrepancy between the measured FMR parameters and those calculated by Schlomann's equation could be ascribed to the effect of sample size. Thus it is suggested that the size effect on FMR should be removed for the analysis of the FMR parameters. Meanwhile, our result for the size dependance of ΔH was found to be contradictory to those reported by Dionne, where ΔH 1/r at a given surface roughness. This discrepancy appears to arise from the difference in the definition of reading the line width.

  • PDF

Study of Improvements to Expansion Methods of Sample O-D Survey Data and Synthesis of O-D Data (표본 O-D 조사자료의 합리적인 전수화 및 O-D함성 방안에 관한 연구)

  • 임성빈
    • Journal of Korean Society of Transportation
    • /
    • v.4 no.2
    • /
    • pp.37-58
    • /
    • 1986
  • Since 1960's there have been conducted quite numbers of origin and destination (0-D) surveys in Korea, Most of them, however, were to be said not so successful. In this paper, it was investigated that why the previous 0-D surveys were failed, and that how it could be improved. The findings of this study are: 1. The collection of sample data itself was performed relatively well, but the problem was in the improper expansion methods which were applied. 2. To improve the expansion methods, it should be performed not only the dwelling unit-based sample surveys but also commercial vehicle survey, cordon line survey, screen line counts and other auxiliary travel surveys like transit patronage survey, vehicle miles survey etc. at the same time. 3. To expand the sample surveyed data in a proper way, the adjustment factors should take a disaggregate form and also should be applied not to the specific trips, but to the specific trip makers to avoid the bias which could be caused by the application of adjustment factors in a way that has been used previously. 4. If there is no considerable change in travel patterns, we can synthesize the present 0-D data with past surveyed sample data, using present statistic data in the same way which was developed in this paper when expanding and adjusting sample data.

  • PDF

Development of an Auto Sample Centering Algorithm at the Macromolecular Crystallography Beam Line of the Pohang Light Source (단백질 결정학 빔 라인에서의 자동 샘플 정렬 알고리즘 개발)

  • Jang, Yu-Jin
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.7
    • /
    • pp.313-318
    • /
    • 2006
  • An automatic sample centering system is underway at the protein crystallography beam line of the Pohang Light Source to improve the efficiency of the crystal screening process. A sample pin which contains a protein crystal is mounted on a goniometer head. Then the crystal should be moved to the center of X-ray beam by controlling the motorized goniometer to obtain diffraction data. Since the X-ray beam is located at the center of the image obtained from the CCD camera when the image of the sample pin is in focus, an auto-focusing algorithm is a very important part in the auto-sample-centering system. However the results of applying several well-known auto focusing algorithms directly to the images are not satisfactory owing to the following factors: misalignment of CCD camera, non-uniform cryo-stream in the background of the image and the supporter of the loop. The performance of an auto-focusing algorithm can be increased if the algorithm is applied to only the loop region identified. Non-uniform cryo-stream and a various illumination condition and a stain, which is shown in the image, are main obstacles to loop region identification. In this paper, a simple loop region identification algorithm, which can solve these problems, is proposed and the effective ness of the proposed scheme is shown by applying the auto-focusing algorithm to the loop region identified.

Study on the Anti-cancer, Anti-metastasis and Effects of Immune-response of Aqua-acupuncture with Cuscutae Semen Infusion Solution (토사자약침(兎絲子藥鍼)의 항암작용(抗癌作用) 및 면역효과(免疫效果)에 대(對)한 실험적(實驗的) 연구(硏究))

  • Lee, Jae-Bok;Lee, Byung-Ryul
    • Journal of Acupuncture Research
    • /
    • v.18 no.3
    • /
    • pp.94-104
    • /
    • 2001
  • Objective : The objective of tihs study is to study the effects of anti-cancer, anti-metastasis and effects of immune-response of aqua-acupuncture with Cuscutae Semen infusion solution. Methods : We observed, in-vitro, the cytotoxicity and the effect on the expression of MMP-9 gene, and in-vivo, change of body weight, surviving number, MST, ILS, changes in amount of WBC, RBC, PLT, GOT, GPT, creatinine, glucose and LDH, number of Pulmonary colony. Results : 1. The effect on expression of MMP-9 gene was decreased in all the sample groups in B16-F10 cell line, and was decreased in Lane 1, 2, 3 in HT1080 cell, compared with control group. 2. BALB/c mice which was transpianted S-180 cancer cell line were inhibited significantly in weight increase, in all the sample groups, compared with control group. 3. The sample groups injected in vein with B16-F10 cancer cell line in C57BL/6 mice did'nt show significant change in the number of WBC, RBC, PLT. 4. In immune experiment, all the sample groups showed having more relevancy to the effect on splenic cell proliferation than normal groups. 5. $IFN-{\gamma}$ and $TNF-{\alpha}$ in cytokine-gene were increased in all the sample groups than control group. 6. In flow cytometry of spienic cell, the numbers of CD4+ cell, CD8+ cell and CD19+ cell in sample groups were increased than in control group. Conclusion : Above the results showed that aqua-acupuncture of Cuscutae Semen infusion solution has effects of anti-cancer, anti-metastasis and immune response improvement.

  • PDF

Study on the Anti-cancer, Anti-metastasis and Immune response improvement of Aqua-acupuncture with Cistanches Herba infusion solution (육종용약침의 항암작용(抗癌作用) 및 면역효과(免疫效果)에 대(對)한 실험적(實驗的) 연구(硏究))

  • Lee, Eun-Yong;Lee, Byung-Ryul
    • Journal of Acupuncture Research
    • /
    • v.17 no.1
    • /
    • pp.251-286
    • /
    • 2000
  • To study the effects of anti-cancer, anti-metastasis and immune response improvement of aqua-acupuncture with Cistanches Herba infusion solution, we used Cistanches Herba infusion solution(taken by water-alcohol method) put into Chung-wan(CV12) and Chok-Samni(S36) of BALB/c or C57BL/6 which are corresponding to human body. We observed the cytotoxicity, the effect on the expression of MMP-9 gene, the ability to control cancer cell proliferation, change of body weight, surviving number, MST, ILS, changes in amount of WBC, RBC, PLT, total protein, creatinine, glucose and LDH, weight of spleen, number of pulmonary colony, histological analysis on tissue metastasis of lung and liver, splenic cell proliferation, the expression of cytokine gene, the number of $CD4^+$, $CD8^+$, $CD19^+$ and NK cell, and concluded like this. The results were obtained as follows : 1. The cytotoxicity about B16-F10 cell line of $2^0$, $2^{-1}$, $2^{-2}$, $2^{-5}$ diluent groups in Cistanches Herba infusion solution treatment was inhibited significantly, compared with control group. 2. The cytotoxicity about HT1080 cell line of $2^0$, $2^{-1}$, $2^{-2}$, $2^{-3}$, $2^{-5}$, $2^{-8}$ diluent groups in Cistanches Herba infusion solution treatment was inhibited significantly, compared with control group. 3. The effect on expression of MMP-9 gene was decreased in all the sample groups, compared with control group. 4. The effect on the control-ability on the cancer cell proliferation showed cytotooicity significantly in $2^0$, $2^{-1}$, $2^{-2}$, $2^{-3}$, $2^{-4}$, $2^{-5}$ diluent groups. 5. S-180 cancer cell line transplants in BALB/c mice were inhibited significantly in weight increase in all the sample groups, compared with control group. The surviving number increased in almost sample groups, except one group put into Chok-Samni(S36) with 20% Cistanches Herba infusion solution treatment group that showed same number of the control group. 6. S-180 cancer cell line transplants in BALB/c mice showed high MST and ILS significantly in almost sample groups, compared with control group. But one group put into Chok-Samni(S36) with 20% Cistanches Herba infusion solution treatment group showed low MST and ILS than control group. 7. The sample group injected in vein with B16-F10 cancer cell line in C57BL/6 mice showed increased ILS compared with control group significantly in anti-metastasis test. 8. The sample group injected in vein with B16-F10 cancer cell line in C57BL/6 mice were increased significantly in the number of WBC and glucose, and decreased significantly in the amount of LDH, compared with control group. However, there's no significant increase or decrease in number of RBC, PLT, total protein and creatinine. 9. We couldn't find any significant relation in spleen weight of the sample group. 10. In pulmonary colony, sample group was decreased significantly, compared with control group. 11. Histological analysis of sample group inhivited compared with that of control group in both of lung and liver. 12. In immune system, all the sample groups showed having more relevancy to the effect on splenic cell proliferation than normal group. 13. The effect on cytokine gene expression of all the sample groups were increased than control group. 14. In flow cytometry there's no significant relation in number of $CD8^+$, $CD19^+$ cell, however, the number of $CD4^+$ cell and NK cell in sample groups were increased than in control group. Above the results showed that aqua-acupuncture of Cistanches Herba infusion solution has effects of anti-cancer, anti-metastasis and immune response improvement.

  • PDF

ON THE NATURE OF SODIUM EXCESS OBJECTS

  • Jeong, Hyunjin;Yi, Sukyoung K.;Kyeong, Jaemann;Sarzi, Marc;Sung, Eon-Chang;Oh, Kyuseok
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.1
    • /
    • pp.47.2-47.2
    • /
    • 2014
  • Several studies have reported the presence of sodium excess objects having neutral atomic absorption lines at $5895{\AA}$ (NaD) and $8190{\AA}$ that are deeper than expected based on stellar population models that match the stellar continuum. The origin of these lines is therefore hotly debated. van Dokkum & Conroy proposed that low-mass stars (0.3M) are more prevalent in massive early-type galaxies, which may lead to a strong NaI 8190 line strength. It is necessary to test this prediction, however, against other prominent optical line indices such as NaD, Mgb, and Fe5270, which can be measured with a significantly higher signal-to-noise ratio than NaI 8190. We identified a new sample of roughly one thousand NaD excess objects (NEOs; ~8% of galaxies in the sample) based on NaD line strength in the redshift range 0.00$H{\beta}$ line strengths and significant emission lines, which are indicative of the presence of young stellar populations. This result implies that the presence of the interstellar medium and/or dust contributes to the increase in NaD line strengths observed for these galaxies.

  • PDF