• Title/Summary/Keyword: sample line

Search Result 888, Processing Time 0.029 seconds

Development of a Flow Injection Analysis Technique for On-line Monitoring of Xylitol Concentrations (자일리톨 농도의 온라인 모니터링을 위한 흐름주입분석기술 개발)

  • 이종일
    • KSBB Journal
    • /
    • v.17 no.4
    • /
    • pp.339-344
    • /
    • 2002
  • Flow injection analysis technique for monitoring of xylitol concentrations in biological processes has been developed using xylitol oxidase (XYO) immobilized on VA-Epoxy Biosynth carrier. The immobilized XYO cartridge has been integrated into a FIA system with an oxygen electrode and systematically investigated with regards to the factors which can affect the activity of the immobilized XYO, such as pH, temperature, salt concentration etc. The activity of the immobilized XYO increased with the temperature ($19.0 - 29.0^{circ}C$) and sample injection volume ($75-250\muL$) and molarity of potassium phosphate buffer (0.1-1 M), but it reached the highest value at pH 8.5. The XYO-FIA system has been also applied for on-line monitoring of xylitol concentrations in a reactor and showed good operational stability and agreement with off-line data measured with HPLC.

On Line Monitoring and Diagnosis Technique for the Array of Photovoltaic Energy System (태양광 발전시스템 전지모듈의 온라인 감시 진단 시스템 개발)

  • Lee, Jong-Pil;Ji, Pyeong-Shik;Byun, Sang-Zoon;Lim, Jae-Yoon
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.4
    • /
    • pp.168-172
    • /
    • 2007
  • The global environment deteriorating which originated from using of fossil fuel is an serious problem for human being to solve. The photovoltaic energy has been considered as a solution. In advanced countries, research and development for photovoltaic(PV) energy system is carrying on. Once installed, a PV array requires maintenance and fault diagnosis other than an occasional cleaning. In this research, the proposed system monitor and diagnosis the output of PV array by on-line for maintenance of PV power plant. The validity of proposed system is verified using sample system.

Tie Line Constrained Equivalent Assisting Generator Model (TEAG) Considering Forced Outage Rates of Transmission Systems

  • Park, Jaeseok;Tran, Trung-Tinh;Sungrok Kang;Park, Dongwook;Jaeyoung Yoon;Seungil Moon;Roy Billinton
    • KIEE International Transactions on Power Engineering
    • /
    • v.4A no.2
    • /
    • pp.91-99
    • /
    • 2004
  • This paper illustrates a tie line constrained equivalent assisting generator (TEA G) model considering forced outage rates of transmission systems for reliability evaluation of interconnected power systems. Interconnections between power systems can provide improved levels of reliability. It is expected that the TEAG model developed in this paper will prove useful in the solution to problems related to the effect of transmission system uncertainties in the reliability evaluation of interconnected power systems. The characteristics and concept of this TEAG considering transmission systems are described in detail by sample studies on a simple test system.

Laser Generation of Focused Lamb Waves

  • Jhang, Kyung-Young;Kim, Hong-Joon;Kim, Hyun-Mook;Ha, Job
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.6
    • /
    • pp.637-642
    • /
    • 2002
  • An arc-shaped line array slit has been used for the laser generation of focused Lamb waves. The spatially expanded Nd:YAG pulse laser was illuminated through the arc-shaped line array slit on the surface of a sample plate to generate the Lamb waves of the same pattern as the slit. Then the generated Lamb waves were focused at the focal point of which distance from the slit position is dependent on the curvature of slit arc. The proposed method showed better spatial resolution than the conventional linear array slit in the detection of laser machined linear defect and drill machined circular defect on aluminum plates of 2mm thickness. Using the focused waves, we could detect the linear defect and the circular defect with the improvement of spatial resolution. The method can also be combined with the scanning mechanism to get an image just like by the scanning acoustic microscope(SAM).

Low Resistivity Ohmic Ni/Si/Ni Contacts to N-Type 4H-SiC (낮은 접촉저항을 갖는 Ni/Si/Ni n형 4H-SiC의 오옴성 접합)

  • Kim C. K.;Yang S. J.;Cho N. I.;Yoo H. J.
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.10
    • /
    • pp.495-499
    • /
    • 2004
  • Characteristics of ohmic Ni/Si/Ni contacts to n-type 4H-SiC are investigated systematically. The ohmic contacts were formed by annealing Ni/Si/Ni sputtered sequentially The annealings were performed at 950℃ using RTP in vacuum ambient and N₂ ambient, respectively. The specific contact resistivity(p/sub c/), sheet resistance(R/sub s/), contact resistance (R/sub c/) transfer length(L/sub T/) were calculated from resistance(R/sub T/) versus contact spacing(d) measurements obtained from TLM(transmission line method) structure. While the resulting measurement values of sample annealed at vacuum ambient were p/sub c/ = 3.8×10/sup -5/Ω㎠, R/sub c/ = 4.9 Ω and R/sub T/ = 9.8 Ω, those of sample annealed at N₂ ambient were p/sub c/ = 2.29×10/sup -4/Ω㎠, R/sub c/ = 12.9 Ω and R/sub T/ = 25.8 Ω. The physical properties of contacts were examined using XRD 3nd AES. The results showed that nickel silicide was formed on SiC and Ni was migrated into SiC. This result indicates that Ni/Si/Ni ohmic contact would be useful in high performance electronic devices.

A Study of Hair Damage by Magic Straight Perm

  • Lim, Sun-Nye
    • Applied Microscopy
    • /
    • v.42 no.3
    • /
    • pp.129-135
    • /
    • 2012
  • In this study, the changes in hair quality before and after Magic straight perm have been evaluated through a hair damage measurement method. For this, a healthy high school student's (age18 years) wavy hair was selected and permed on the left and right sides. Then, the changes caused by physical methods which were applied during the fl at iron-based Magic straight perm were evaluated based on the hair damage measurement method before and after the Magic straight perm. According to the protein release test after the Magic straight perm, 1.26% in average and 0.14% was observed in Cool Magic straight perm sample. In a field emission scanning electron microscopy (FE-SEM) test, saw teeth-shaped partial desquamation of cuticle cells and impurities were observed in the warm-treated hair sample. In atomic force microscope (AFM), line-profile is a method to represent roughness data on hair. According to analysis on 3-dimensional (3D) images, the hair with Cool Magic straight perm was lower than the hair with Warm Magic perm in terms of the color change of 3D images. In addition, vertical changes were observed in the hair with Cool Magic perm. As a result, irregular surface roughness was observed. This study proposed a method to minimize hair damage by cooling down the heat with the cool hair straightener as soon as the Warm Magic was finished.

Fin Cutting Line Detection Technique based on RANSAC for Fish Cutting Automation System (생선 가공 자동화 시스템을 위한 RANSAC 기반 지느러미 절단선 검출 기법)

  • Jang, Yonghun;Park, Changhyeon
    • Journal of KIISE
    • /
    • v.43 no.3
    • /
    • pp.346-352
    • /
    • 2016
  • The fishing industry requires many workers to manually carry out the jobs of sorting and cutting fishes. There are therefore many dangerous situations in their working environment and the throughput is inefficiently low. This paper introduces an automatic fin cutting system based on RANSAC that is able to increase the throughput of fish processing jobs. The system proposed in this paper first detects the edges of a fish using a high-pass filter. The boundary lines between fin and body are then detected by adjusting parameters and the threshold of the noise filters. Finally, the optimal cutting lines are detected using RANSAC. Through an experiment with a sample of 50 fishes, this paper shows that the proposed system detects the cutting lines with about 90% accuracy.

Effects of the length the MSL on the oscillation characteristic of the VCO (VCO의 MSL길이가 발진특성에 미치는 영향)

  • 이동희;정진휘
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.721-724
    • /
    • 2001
  • In this paper, we present the effect the length the MSL(Microstrip Line) on the oscillation characteristic of the fabricated VCOs(Voltage Controlled Oscillator) designed and analyzed by RF circuit simulator Serenade(ANSOFT Co.) and fabricated by screen printing method on the alumina substrate. We have fabricated VCOs with 3 different MSL length and each MSL length of the VCO is 140mi1, 280mil and 560mi1. The oscillation frequency of each sample(VCO) was tuned to UHF band(750MHz∼900MHz) varying the capacitance. The experimental result shows the phase noise -82∼-97[dBc/Hz] at a 50 [kHz] offset frequency, the pushing figure 94∼318[kHz] at 3${\pm}$0.15[V] and the harmonics 13∼21 [dBc] between MSL length 140mi1s and 560mi1. The frequency and output variation width are 779∼898[MHz], -36∼-33[dBm] at MSL length 140mi1; 818∼836[MHz], -27.19∼-27.06[dBm] at 280mi1;751.54∼751.198[MHz],-33.44∼ -33.31[dBm] at 560mi1. we examined 3 VCOs oscillation characteristic difference through comparison with phase noise, oscillation power and frequency by control voltage change, harmonics and pushing figure for each sample.

  • PDF

Studies on the Electrical Properties of $Dy_{2-x}Sr_{1+x}Fe_2O_{7-y}$ ferrite System Which Can be used as Filler for Conducting Rubbers (도전성 고무의 충전제로 이용 가능한 $Dy_{2-x}Sr_{1+x}Fe_2O_{7-y}$ 페라이트계의 전기적 특성에 대한 연구)

  • Lee, Eun-Seok;Choi, Sei-Young
    • Elastomers and Composites
    • /
    • v.28 no.2
    • /
    • pp.103-107
    • /
    • 1993
  • To make new filler for conducting rubber, the sample of perovskite-related ferrite system $Dy_{2-x}Sr_{1+x}Fe_2O_{7-y}$ (x=0.0, 0.5, 1.0, 1.5, and 2.0) were synthesized at 1473K in air. $M{\ddot{o}}ssbauer$ spetrum of x=0.0 sample shows typical six line pattern with $M{\ddot{o}}ssbauer$ parameters, $I.S=3.6{\times}10^{-1}mm/sec,\;E_Q=-7.0{\times}10^{-2}mm/sec,\;H_{int}=5.19{\times}10^2\;Koe$. In case of x=2.0, the spectrum is composed of single line exhibiting coexistance of $Fe^{3+}(I.S.=3.7{\times}10^{-1}mm/sec)$ ions and $Fe^{4+}(I.S.=-1.9{\times}10^{-1}mm/sec)$ ions. With increase in x value electrical conductivity at constant temperature sharply increased and the activation energies decreased from $3.8{\times}10^{-1}\;to\;1.9{\times}10^{-1}\;eV$.

  • PDF

AN ANALYSIS OF SOFT TISSUE PROFILE (연조직 측모에 관한 분석)

  • Chang, Young-Il;Choi, Hee-Young;Shin, Soo-Jung
    • The korean journal of orthodontics
    • /
    • v.25 no.5 s.52
    • /
    • pp.627-634
    • /
    • 1995
  • The purpose of this study to analyze characteristics of soft tissue profile in Korean young adults. The sample consisted of 50 young adults (25 males and B females) who had pleasing and normal occlusion. Soft tissue analysis (facial convexity angle, nasolabial angle, H-angle, Z-angle, E-line to upper lip, lower lip, Sn-pog' to upper lip, lower lip) was performed on lateral cephlograms. Mem and standard deviation was obtained. When compared by other studies, mean profile of this sample was relatively straighter and both the upper and lower lips was more protrusive.

  • PDF