• 제목/요약/키워드: same department

검색결과 19,781건 처리시간 0.038초

Flexural, electrical, thermal and electromagnetic interference shielding properties of xGnP and carbon nanotube filled epoxy hybrid nanocomposites

  • Lee, Young Sil;Park, Yeon Ho;Yoon, Kwan Han
    • Carbon letters
    • /
    • 제24권
    • /
    • pp.41-46
    • /
    • 2017
  • The microstructure, flexural properties, electrical conductivity, thermal conductivity and electromagnetic interference (EMI) shielding effectiveness (SE) of epoxy composites filled with multi-walled carbon nanotubes (CNTs), exfoliated graphite nanoplatelets (xGnPs) and CNT-xGnP hybrid filler were investigated. The EMI SE of the CNT-xGnP hybrid composite was higher than 25 dB at 100 MHz while that of the xGnP based composite was almost zero. The flexural modulus of the CNT-xGnP based epoxy composite continuously increased to 3.32 GPa with combined filler content up to 10 wt% while that of the CNT based epoxy composites slightly decreased to 1.96 GPa at 4 wt% CNT, and dropped to 1.57 GPa at 5 wt% loading, which is lower than that of epoxy. The CNT and CNT-xGnP samples had the same EMI SE at the same surface resistivity, because samples with the same surface conductivity have the same amount of the charge carriers.

Change of Blood Cells' Number from Capillaries and Venous Blood of 20's Healthy Adults

  • Seon, Ji-Yeong;Lee, Jae Sik
    • 대한임상검사과학회지
    • /
    • 제43권4호
    • /
    • pp.156-160
    • /
    • 2011
  • It was confirmed that we got somewhat different results even though we performed same items with same methods from capillaries and venous blood of healthy 72 cases. Items which capillaries blood has higher value than venous blood are the numbers of erythrocyte, lymphocyte, basophil, hematocrit, MCHC and RDW. Total numbers of RBC (p<0.035), lymphocyte and basophil are shown statistically significance. Items which venous blood has higher value than capillary blood are the numbers of platelet (p<0.00) and neutrophil (p<0.01). Fallible items in clinics can be shown the numbers of RBC, platelet, lymphocyte and neutrophil because we got somewhat different results even though we performed same items with same methods from capillaries and venous blood, respectively. It is necessary to choose the clear criteria and normal value depends on clinical specimen as the number of platelets are measured with an abnormal value shown over 40% down. As normal difference according to each item and method is currently acceptable and applicable in clinics, it is considered that a new normal value depends on clinical specimen should be established and is to be useful positively in clinics.

  • PDF

협응이동훈련이 정상 성인의 지지발에 따른 족부압력분포에 미치는 변화 (Change of Foot Pressure Distributions on Stance Leg during Coordinative Locomotor Training in Healthy Adults)

  • 임재헌;국은주;김진철
    • 대한물리의학회지
    • /
    • 제18권1호
    • /
    • pp.59-66
    • /
    • 2023
  • PURPOSE: This study examined the foot pressure distribution using the sprinter and skater patterns of coordinative locomotor training. METHODS: Thirty healthy adults, comprising 11 men and 19 women, participated in the study. All the participants performed patterns in sprinter pattern conditions 1-3 and skater pattern conditions 1-3, and were measured using a pedoscan to determine the applied foot pressure distribution. RESULTS: The participants significantly differed in the big toe during the sprinter pattern. As a result of the post hoc test, opposite and opposite sprinters showed a significant difference from the same sprinters (same sprinter; 21.33 ± 5.92, opposite sprinter; 23.54 ± 5.41, and reopposite sprinter; 24.14 ± 6.46). There was a significant difference in the lateral side during the skater pattern. As a result of the post hoc test, reopposite and same skaters showed a significant difference from opposite skaters (same skater; 49.88 ± 5.75, opposite skater; 48.78 ± 5.64, and reopposite skater; 51.15 ± 5.37). CONCLUSION: The foot pressure was distributed toward the hallux and fifth toe according to the sprinter and skater patterns of coordinative locomotor training.

Q-Switching of a Diode-Pumped Nd:YVO4 Laser with a Closely Folded Resonator

  • Lee Hyuncheol;Lee Yongwoo;Kwak Chonghoon;Kwon Jinhyuk;Yi Jonghoon;Lim Yong-Sik
    • Journal of the Optical Society of Korea
    • /
    • 제9권2호
    • /
    • pp.64-67
    • /
    • 2005
  • A diode-pumped $Nd:YVO_4$ laser is developed. The laser has a closely folded resonator. The laser beam in two arms of the folded resonator passes the same acousto-optic modulator. The laser output power and pulsewidth dependence on a Q-switching frequency were measured. It is found that the newly proposed geometry provides an effective means for reducing the pulsewidth while maintaining almost the same output power compared with the usual folded resonator, where the beam in one arm of the resonator passes the acousto-optic modulator.

Structural Similarity and Expression Differences of Two Pj-Vg Genes from the Pandalus Shrimp Pandalopsis japonica

  • Jeon, Jeong-Min;Kim, Bo-Kwang;Kim, Young-Ji;Kim, Hyun-Woo
    • Fisheries and Aquatic Sciences
    • /
    • 제14권1호
    • /
    • pp.22-30
    • /
    • 2011
  • Vitellogenin (Vg) is the precursor of vitellin (Vn), which is the major yolk protein in nearly all oviparous species, including fish, amphibians, reptiles, and most invertebrates. It is one of the most important factors during reproduction, and numerous studies have shown that Vg genes are markers of the reproductive cycle and effecter genes induced by endocrine-disrupting chemicals (EDCs). Previously, we isolated two distinct cDNAs encoding vitellogenin homologs Pj-Vg1 and Pj-Vg2 from Pandalus shrimp Pandalopsis japonica. In this study, full-length genomic sequences of Pj-Vg1 and Pj-Vg2 were determined using a PCR-based genome walking strategy. Isolated Pj-Vg1 and Pj-Vg2 genes were 11,910 and 11,850 bp long, respectively. Both Pj-Vg genes had 15 exons and 14 introns, and the splicing sites were also the same, suggesting that they arose via gene duplication. The similar structural characteristics of decapod Vg genes suggest that they are all orthologs that evolved from the same ancestral gene. Analysis of Pj-Vg1 and Pj-Vg2 expression revealed that the relative copy numbers of Pj-Vg1 and Pj-Vg2 were similar in the hepatopancreas, whereas Pj-Vg2 transcripts were also detected in the ovary. Expression of both Pj-Vg genes was induced in hepatopancreas of mature individuals, whereas only Pj-Vg2 transcripts were upregulated in the ovaries from mature animals, suggesting that both Pj-Vgs are important for oocyte development. A strong positive correlation was found between Pj-Vg1 and Pj-Vg2 transcripts in the same individual, indicating they are under the same control mechanisms. Additionally, a positive correlation was found between ovarian and hepatopancreatic Pj-Vg2 transcripts, suggesting that its dual expression is regulated by similar physiological conditions. Knowledge of the similarities and differences between the two vitellogenin-like genes, Pj-Vg1 and Pj-Vg2, would help us to understand their roles in reproduction and other physiological effects.

Test-Retest Reliability of Level-Specific CE-Chirp Auditory Brainstem Response in Normal-Hearing Adults

  • Jamal, Fatin Nabilah;Dzulkarnain, Ahmad Aidil Arafat;Shahrudin, Fatin Amira;Marzuki, Muhammad Nasrullah
    • Journal of Audiology & Otology
    • /
    • 제25권1호
    • /
    • pp.14-21
    • /
    • 2021
  • Background and Objectives: There is growing interest in the use of the Level-specific (LS) CE-Chirp® stimulus in auditory brainstem response (ABR) due to its ability to produce prominent ABR waves with robust amplitudes. There are no known studies that investigate the test-retest reliability of the ABR to the LS CE-Chirp® stimulus. The present study aims to investigate the test-retest reliability of the ABR to the LS CE-Chirp® stimulus and compare its reliability with the ABR to standard click stimulus at multiple intensity levels in normal-hearing adults. Subjects and Methods: Eleven normal-hearing adults participated. The ABR test was repeated twice in the same clinical session and conducted again in another session. The ABR was acquired using both the click and LS CE-Chirp® stimuli at 4 presentation levels (80, 60, 40, and 20 dBnHL). Only the right ear was tested using the ipsilateral electrode montage. The reliability of the ABR findings (amplitudes and latencies) to the click and LS CE-Chirp® stimuli within the same clinical session and between the two clinical sessions was calculated using an intra-class correlation coefficient analysis (ICC). Results: The results showed a significant correlation of the ABR findings (amplitude and latencies) to both stimuli within the same session and between the clinical sessions. The ICC values ranged from moderate to excellent. Conclusions: The ABR results from both the LS CE-Chirp® and click stimuli were consistent and reliable over the two clinical sessions suggesting that both stimuli can be used for neurological diagnoses with the same reliability.

Test-Retest Reliability of Level-Specific CE-Chirp Auditory Brainstem Response in Normal-Hearing Adults

  • Jamal, Fatin Nabilah;Dzulkarnain, Ahmad Aidil Arafat;Shahrudin, Fatin Amira;Marzuki, Muhammad Nasrullah
    • 대한청각학회지
    • /
    • 제25권1호
    • /
    • pp.14-21
    • /
    • 2021
  • Background and Objectives: There is growing interest in the use of the Level-specific (LS) CE-Chirp® stimulus in auditory brainstem response (ABR) due to its ability to produce prominent ABR waves with robust amplitudes. There are no known studies that investigate the test-retest reliability of the ABR to the LS CE-Chirp® stimulus. The present study aims to investigate the test-retest reliability of the ABR to the LS CE-Chirp® stimulus and compare its reliability with the ABR to standard click stimulus at multiple intensity levels in normal-hearing adults. Subjects and Methods: Eleven normal-hearing adults participated. The ABR test was repeated twice in the same clinical session and conducted again in another session. The ABR was acquired using both the click and LS CE-Chirp® stimuli at 4 presentation levels (80, 60, 40, and 20 dBnHL). Only the right ear was tested using the ipsilateral electrode montage. The reliability of the ABR findings (amplitudes and latencies) to the click and LS CE-Chirp® stimuli within the same clinical session and between the two clinical sessions was calculated using an intra-class correlation coefficient analysis (ICC). Results: The results showed a significant correlation of the ABR findings (amplitude and latencies) to both stimuli within the same session and between the clinical sessions. The ICC values ranged from moderate to excellent. Conclusions: The ABR results from both the LS CE-Chirp® and click stimuli were consistent and reliable over the two clinical sessions suggesting that both stimuli can be used for neurological diagnoses with the same reliability.

지역사회 노인을 위한 대면과 비대면 운동프로그램이 운동 만족도에 미치는 영향 (Effects of Face-to-face and Non-face-to-face Exercise Programs on Exercise Satisfaction for the Elderly in the Community)

  • 이다솔;이한숙;김래현;김예슬;김채윤;박범식;박병현;신미지;오은주;우수민;유지민;이주연;정성흠;정효규
    • 대한물리의학회지
    • /
    • 제18권1호
    • /
    • pp.67-76
    • /
    • 2023
  • PURPOSE: The study compared the satisfaction of the exercise program in a face-to-face and non-face-to-face manner with the same exercise program. METHODS: This study was conducted through convenience sampling for 57 seniors over 65 years of age. After conducting 30 minutes of the same exercise program face-to-face on the first visit and non-face-to-face on the second visit, a satisfaction survey was conducted. The survey data were processed statistically using SPSS 26.0 (SPSS Inc, IBM, USA). An independent t-test was used to compare the type of exercise program. The Spearman's Rank Correlation was conducted to correlate the satisfaction between cognitive function and education level. RESULTS: The overall satisfaction with the face-to-face program was higher than the non-face-to-face exercise programs. All three satisfaction items in face-to-face exercise programs were higher than in non-face-to-face exercise programs (p < .05). The main source of dissatisfaction in the case of face-to-face exercise programs was having a good relationship with people for face-to-face and a 'lack of communication' in the case of non-face-to-face. CONCLUSION: The elderly showed higher satisfaction in face-to-face exercise than in non-face-to-face exercise. This study is significant in that accurate satisfaction comparison was possible by conducting the same exercise program on the same subject for a relatively short time, and through this, the development of an exercise program was suggested.

Uniform Side Illumination Generated from LEDs Arranged by an Annealing Algorithm

  • Wang, Xu;Lei, Panling;Qian, Chaoyi;Wang, Zhiping;Xu, Xuefen;Su, Zhouping
    • Current Optics and Photonics
    • /
    • 제6권3호
    • /
    • pp.332-336
    • /
    • 2022
  • Given a cubic space, it is easy to uniformly illuminate the floor with light sources placed on top. However, little has been reported about uniform illumination on walls with the same configuration of light sources. Here we present a luminaire consisting of nine light-emitting diodes (LEDs) with perfect Lambertian distribution, placed on the top as a 3 × 3 rectangular LED array. The distances between LEDs and tilt angles of each individual LED are adjustable and optimized by an annealing algorithm. After optimization, the array produces a rectangular illumination pattern on one wall with a uniformity of about 89%. Analysis shows that the tilt angles of individual LEDs are key parameters for uniform side illumination. In a scenario that is more practical, the tilt angles of all the LEDs are set to be the same, only decreasing the uniformity to 83%.

중소형 회로 차단기에 적용 가능한 한류 메커니즘의 개발 (A Study on the impact on the quality of hemming the number of hemming process)

  • 이제덕;박종식;임재국;박동희;박민호;최계광;김세환;윤재웅;이춘규
    • Design & Manufacturing
    • /
    • 제10권1호
    • /
    • pp.41-45
    • /
    • 2016
  • Electrical equipment in factories, buildings, etc. with the development of the industry has become a large capacity. By the development, electric load also become diversified and there is also highly functional requirements being electrical equipment. Particularly in the small and medium-sized circuit breakers, tend to preferentially consider the economy stands out and improvements in safety, ease of mounting and connection through the modularity of the basic dimensions compact and cost to block expansion of the scope of the development of capacity, etc. The product having a competitive has been strongly required. In order to implement the circuit breakers of breaking capacity and compact at the same time taking into account the economic development of this technology applied to the current-limiting mechanism is essential budget or the current limiting mechanism is currently available mechanisms applicable to small and medium-sized frame (frame) can not do it. In this paper, at the same time satisfying the economic efficiency, by minimizing the load force of the moving contactor (moving contactor) to be applied to small and medium frame other hand to secure the economical efficiency without using high speed contact parting acceleration of the moving contactor conventional current-limiting mechanism, and to develop a current-limiting mechanism that can be satisfied with the same or higher performance to meet the needs of the market.