Analysis of Leakage Current Waveforms for Transmission Line Porcelain Insulators due to ESDD Contamination (ESDD 오손에 따른 송전용자기애자의 누설전류 파형의 분석)

  • Park, Jae-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.10
    • /
    • pp.1461-1470
    • /
    • 2012
  • This paper reports the contamination performance of transmission line porcelain insulators tested under five different contaminant conditions - clean and ESDD (equivalent salt deposit density) level (A, B, C, and D) through measurement of their leakage current under drop of potential method. To estimate the contamination for transmission line porcelain insulators, leakage current waveform and its maximum value were measured under step-up power test. In the clean insulators test, % distortion factors decreased with increasing step-up power, and as the ESDD level increased, some characteristics such as frequency analysis, harmonics and % distortion facotor could be used for contamination diagnosis of the transmission line porcelain insulators.

Analysis of Deterioration Characteristics for Connection Factor used in Grounding System (접지시스템에 사용되는 접속요소의 열화특성 분석)

  • Gil, Hyoung-Jun;Shong, Kil-Mok;Kim, Young-Seok;Kim, Chong-Min
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.2
    • /
    • pp.9-13
    • /
    • 2015
  • This paper describes the analysis of deterioration characteristics for connection factor used in grounding system. The connection method of grounding system is specified in IEC standard. In order to analyze the deterioration characteristics for connection factor, deterioration test was carried out when the connection factor was buried in salt water and underground. The test connection factors were C-type sleeve, clamp, and exothermic welding. As a consequence, most of the connection factor was corroded, and the electrical resistance decreased after deterioration. The analytical results can be used to establish the safety of grounding system.

Analysis of Deterioration Characteristics for Connection Factor according to Connection Method of Grounding System (접지시스템의 접속방식에 따른 접속요소의 열화특성 분석)

  • Gil, Hyoung-Jun;Kim, Hyang-Kon;Kim, Dong-Ook;Kim, Dong-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.2126-2127
    • /
    • 2011
  • This paper describes the analysis of deterioration characteristics for connection factor according to connection method of grounding system. The connection method of grounding system is specified in IEC standard. In order to analyze the deterioration characteristics for connection factor, deterioration test was carried out when the connection factor was buried in salt water and underground. The test connection factors were C-type sleeve, clamp, and exothermic welding. As a consequence, most of the connection factor was corroded, and the electrical resistance decreased after deterioration. The analytical results can be used to establish the safety of grounding system.

  • PDF

Chemical Composition and Sources of Atmospheric Particulates Collected on the West Coast of Korea (서해안 대가 분진의 화학 조성 및 기원에 대한 연구 (1))

  • 최만식;조성록;이동수
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.5 no.2
    • /
    • pp.72-83
    • /
    • 1989
  • Twenty-five atmospheric particulates were collected using a high volume aerosol sampler from Septermber to December, 1988 on a site located on the West coast of Korea and analysed for twelve elements (Na, Mg, Al, Mn, Fe, Cu, Co, Ni, Zn, Ag, Cd, and Pb) by AAS. The particles being mainly crustal minerals, large quantity of spherical fly ashes were also observed. In order to identify the origin of trace metals in atmospheric particulates, enrichment factor, interelemental correlation and factor analysis were performed. Based upon these analysis, the twelve elements can be classified into three groups; the elements dominantly present in soil particles (Al, Mn, Fe, Co, and Ni), those in sea salt aerosols (Na and Mg), and those in air pollution-derived particles (Cu, Cd, Pb, Ag and Zn).

  • PDF

A Study on the Characteristics of ELB Insulating Material deteriorated by Salt water (염수에 의해 열화된 누전차단기 절연재료의 특성에 관한 연구)

  • Kim, Hyung-Rae;Kim, Dong-Ook;Kim, Hyeog-Soo;Choi, Chung-Seog;Kim, Hoon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.878-881
    • /
    • 2001
  • In this paper, we analyzed the characteristics of insulating material with ELB(earth leakage circuit breaker) through tracking experiment and the study was carried out three different types of samples. The tracking is breakdown phenomenon of material surface that is generated on the organic insulating material. The test method applied IEC publication 587. The result of the sample breakdown by tracking was carbonized and resistance of between the electrodes is approximately 300$\Omega$. In the result of DSC analysis, the caloric peak was detected before 100$^{\circ}C$ in product of tracking. It appeared weight loss of 10.87% at 537$^{\circ}C$ on TGA. IR spectrum analysis showed carbon-hydrogen(C-H)bond on molecular structure that is the sample of tracking.

  • PDF

Characteristics of Material Damage Caused by Acid Deposition in East Asia

  • Yoo, Young-Eok;Maeda, Yasuaki
    • Journal of Environmental Science International
    • /
    • v.11 no.5
    • /
    • pp.445-454
    • /
    • 2002
  • Material exposure experiments were performed to evaluate the relationship between air pollution and material corrosion rates based on collaboration with researchers in China, Japan, and Korea. Qualitative and quantitative atmospheric corrosion was estimated from damage caused to bronze, copper, steel, marble, cedar, cypress, and lacquer plates exposed to outdoor and indoor conditions in certain East Asian cities. The effects of atmospheric and meteorological factors on the damage to the copper plates and marble pieces were estimated using a regression analysis. The results indicated that sulfur dioxide produced the most destruction of the materials, especially in South Korea and China. In Japan, the copper plates were damaged as a result of natural conditions and sea salt. Copper was also found to be damaged by the surface deposition of sulfur and chlorine. Meanwhile, marble was substantially degraded by gaseous sulfur dioxide, yet sulfate ions in rain had no effect. Accordingly, the analysis of air pollution from the perspective of material damage was determined to be very useful in evaluating and substantiating the intensity of air pollution in East Asia.

Studies on thermal and swelling properties of Poly (NIPAM-co-2-HEA) based hydrogels

  • Shekhar, Suman;Mukherjee, M.;Sen, Akhil Kumar
    • Advances in materials Research
    • /
    • v.1 no.4
    • /
    • pp.269-284
    • /
    • 2012
  • Thermoresponsive hydrogels based on N-Isopropylacrylamide (NIPAM) and 2-Hydroxyethylacrylate (HEA) were prepared by free radical polymerization. The hydrogels were characterized by elemental (CHN) analysis, differential scanning calorimetry (DSC) and thermo gravimetric analysis (TGA). DSC thermogram showed two endothermic transitions which are due to hydration of water present in different environments. One near $0^{\circ}C$ called melting transition of ice and was used to calculate the quantitative determination of the amounts of freezing and non freezing water. The other transition above the ambient temperature was due to the combination of hydrophobic hydration and hydrophilic hydration which changes with the copolymer compositions. Swelling and deswelling studies of the hydrogels were carried out using the aqueous media, salt and urea solutions. The experimental results from swelling studies revealed that copolymers have lower rates of swelling and deswelling than the homopolymer.

Desorption EMC Models for Rapeseed (유채씨의 방습 평형함수율)

  • Kim, You-Ho;Han, Jea-Woong;Keum, Dong-Hyuk
    • Journal of Biosystems Engineering
    • /
    • v.32 no.6
    • /
    • pp.403-407
    • /
    • 2007
  • This study was performed to determine desorption equilibrium moisture contents(EMC) of rapeseed grown in Korea. EMC values were measured by static method using saturated salt solutions at three temperature levels of 30, 40 and $50^{\circ}C$, and eight relative humidity levels in the range from 11.0 to 83.6%. The measured EMC values were fitted to Chung-Pfost, Modified Halsey, Modified Henderson and Modified Oswin models by using nonlinear regression analysis. The results of root mean square errors for four models showed that Halsey and Modified Oswin Models could serve as good models, but the Chung-Pfost and Modified Henderson models could not show reasonably good fitting.

Detection and Genomic Analysis of Viroid-like RNA Molecules Isolated from Korean Peonies (한국산 작약에서 분리한 바이로이드 유사 RNA 분자의 확인과 유전자 분석)

  • 정동수;김무인;이재열
    • Korean Journal Plant Pathology
    • /
    • v.13 no.2
    • /
    • pp.113-117
    • /
    • 1997
  • Low moleuclar weight (LMW) RNAs were isolated form Korean peonies which expressed symptoms of stunt and epinasty. The LMW plant RNAs were purified by Qiagen column chromatography which could separate viroid specific nucleic acid at differential salt concentration. After the inoculation of the purified RNAs from the peonies, the inoculated tomatoes (cv. Rutgers) expressed the symptoms of stunt and epinasty. Also the same molecular weight RNAs with viroid-like RNAs were isolated from the inoculated tomatoes. Double-stranded cDNA were synthesized by the methods of reverse transcription (RT) and polymerase chain reaction (PCR) with the purified RNA and primers. The same cDNAs associated with viroid-like RNAs wre cloned from the inoculated tomatoes. The cDNA has been sequenced and its 375-nucleotides were arranged into secondary structure. The cloned cDNA showed 47~54% homology compared with other viroids. The sequence homology of the cloned cDNA were partially high with plant genomic RNAs.

  • PDF

Adsorption Equilibrium Moisture Content of Rough Rice, Brown Rice, White Rice and Rice Hull (벼, 현미, 백미 및 왕겨의 흡습평형함수율)

  • Keum, D. H.;Kim, H.
    • Journal of Biosystems Engineering
    • /
    • v.26 no.1
    • /
    • pp.57-66
    • /
    • 2001
  • This study was performed to determine adsorption equilibrium moisture contents of rough rice, brown rice, white rice and rice hull grown in Korea. EMC values were measured by static method using saturated salt solutions at three temperature levels of 20$\^{C}$, 30$\^{C}$ and 40$\^{C}$, and eight relative humidity levels in the range from 11.2% to 85.0%. The measured EMC values were fitted to modified Henderson, Chung-Pfost, and modified Oswin models by using nonlinear regression analysis. The results of comparing root mean square errors for three models showed that modified Henderson and Chung-Pfost models could serve as good models, and that modified Oswin model could not be applicable to rough rice, brown rice, white rice and rice hull.

  • PDF