• Title/Summary/Keyword: saline environment

Search Result 174, Processing Time 0.025 seconds

Comparison of hydrochemical informations of groundwater obtained from two different underground storage systems

  • Lee, Jeonghoon;Kim, Jun-Mo;Chang, Ho-Wan
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.04a
    • /
    • pp.110-113
    • /
    • 2002
  • Statistical- based, principal component analysis (PCA) was applied to chemical data from two underground storage systems containing LPG to assess the usefulness of such technique at the initial stage (Pyeongtaek) or middle stage (Ulsan) of hydrochemical studies. For the first case, both natural and anthropogenic contamination characterize regional groundwater. Saline water buffered by Namyang lake affects as a natural factor, whereas cement grouting influence as an artificial factor. For the second study area, contaminations due to operation of LPG caverns, such as disinfection activity and cement grouting effect, deteriorate groundwater quality. This study indicates that principal component analysis would be particularly useful for summarizing large data set for the purpose of subsurface characterization, assessing their vulnerability to contamination and protecting recharge zones.

  • PDF

Descriptive Analysis of Low Saline Water in Youngdeuk, the East Coast of Korea in 2010 (2010년 동해 영덕 연안의 저염수)

  • Choi, Yong-Kyu;Kwon, Kee-Young;Yang, Joon-Yong
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.18 no.5
    • /
    • pp.379-387
    • /
    • 2012
  • In order to see the oceanographic conditions, the observations of aquaculture farm of ascidian in Youngdeuk, the east coast of Korea were conducted through 6 times-23 February, 6 April, 8 June, 19 August, 6 October and 20 December-in 2010. Surveys were conducted in 20 stations bimonthly using SBE 19 CTD instrument. The mixed layer depth (MLD) was deep in winter and shallow in summer. The cold water below $5^{\circ}C$ in temperature was occupied below thermocline through all season. The temperature was high in the southeastern area. The salinity was increased from the coast to the open sea. The halocline was distinct at 20 m depth in August and at 40 m depth in October. The lowest value of salinity was appeared at the depth of 10 m in October. In addition the value of precipitation minus evaporation denoted negative in October. These low saline water seemed to inflow to the coast from the open sea. Therefore the low saline water moved to the east coast of Korea. The EKWC may play an important role to convey the low saline water. It may affect the aquaculture farm along the coast as the mass mortality of ascidian. It needs to clarify the role and pathway of EKWC to transfer the low saline water along the east coast of Korea.

Abundance and Diversity of Microbial Communities in the Coastal Aquifers in Songji Lagoon, South Korea (송지호 해안 대수층 미생물 군집의 풍부도 및 다양성)

  • Jung-Yun Lee;Dong-Hun Kim;Woo-Hyun Jeon;Hee Sun Moon
    • Journal of Soil and Groundwater Environment
    • /
    • v.28 no.5
    • /
    • pp.12-24
    • /
    • 2023
  • The Songji lagoon is brackish environment with a mixture of saline and fresh water, and the interaction of groundwater-lagoon water creates a physicochemical gradient. Although some studies have been conducted on the hydrological and geochemical characteristics of the Songji lagoon, microbial ecological studies have not yet been conducted. In this study, we investigated the effect of groundwater and surface water interaction on water quality as well as microbial community changes in the Songji Lagoon using 16S rRNA gene sequencing. Hydrochemical analyses show that samples were classified as 5 hydrochemical facies (HF) and hydrochemical facies evolution (HFE) revealed the intrusion phase was more dominant (57.9%) than the freshening phase (42.1%). Higher microbial diversity was found in freshwater in comparison to saline water samples. The microbial community at the phylum level shows the most dominance of Proteobacteria with an average of 37.3%, followed by Bacteroidota, Actinobacteria, and Patescibacteria. Heat map analyses of the top 18 genera showed that samples were clustered into 5 groups based on type, and Pseudoalteromonas could be used potential indicator for seawater intrusion.

Effects of several suspending media on behavior of Toxoplasma gondii (보존액이 Toxoplasma gondii의 생존성에 미치는 영향)

  • Jin, Joo-Eun;Chung, Kyung-Tae;Lee, Woo-Won;Yang, Ju;Lee, Gang-Rog;Kim, Geun-Kyu
    • Korean Journal of Veterinary Service
    • /
    • v.22 no.2
    • /
    • pp.129-134
    • /
    • 1999
  • A preservation test of Toxoplasma gondii tachyzoites for considerable time was tried to obtain simple and economical methods using various suspending media at $4^{\circ}C$ rather than serial passage of the parasite in mice. The preservation period was a term that the tachyzoites were detected from the peritoneal fluid of mice after inoculation of 2$\times$$10^5$ organisms preserved according to the lapse of time. The numbers of tachyzoite per 1\textrm{mm}^3$ of the peritoneal fluid with 2$m\ell$ of the saline solution taken in 4days after inoculation were presented as percentage in proportion to the control. The numbers. of tachyzoite per 1\textrm{mm}^3$ of the peritoneal fluid of the control were consisted of the average number of the tachyzoites of 10 mice inoculated with 2$\times$$10^5$ organisms by serial mouse passage. The tachyzoites could be preserved for 26 days in the suspending medium of saline solution at $4^{\circ}C$ Ringer's solution for 18 days, Hank's solution for 28 days, and egg-glycerine solution for 50 days.

  • PDF

A development of new dielectric tracer test method for groundwater logging: laboratory soil column test (지하수 검층을 위한 새로운 유전율 추적자 시험법의 개발)

  • Kim Man-Il;Kim Hyoung-Soo;Jeong Gyo-Cheol
    • The Journal of Engineering Geology
    • /
    • v.14 no.3 s.40
    • /
    • pp.301-311
    • /
    • 2004
  • This study is suggested a new dielectric tracer test method to understand geological structure of porous media and groundwater flow to use the dielectric constant which is one of electrical special quality of various geological materials. To measure their parameters, tracer material is made an ethanol mixing liquid(EML) having a same specific gravity of water. Also, soil materials are prepared a dielectric tracer test using the FDR system that could measure dielectric constant for saturated standard sand and river sand layers which have different initial porosity. To compare with their results, we discussed with the concentration variation of saline water having a saline concentration $3\%$ which is general tracer material by using the electro multi-meter system in the laboratory or field test. In two tracer experiment results, EML tracer test could confirm definitely EML concentration variation from each saturated soil layer as standard and river sands. However, tracer test of saline water $3\%$ concentration could not confirm permeating movement of water by degree of salinity change because these are settled at lower part column in a whole column area continuously. These causes are that specific gravity of saline water is heavier than water. That is, it could know that deposition of saline water is composed of lower part of soil column continuously independently of the direction of water into saturated soil material.

The changes of soil salinity in the Pinus densiflora forest after seawater spread using a fire-fight helicopter

  • Park, Jeong Soo;Koo, Kyu-Sang;Lee, Eun Ju
    • Journal of Ecology and Environment
    • /
    • v.38 no.4
    • /
    • pp.443-450
    • /
    • 2015
  • The east coast of the Korean Peninsula is susceptible to fires because of the low rainfall in winter and spring, and large forest fires have occurred in this area. Lack of fresh water to combat fires has hampered efforts to prevent widespread forest fires in this region. Seawater has not been used as a suppressant because of possible detrimental effects of salt. We investigated the mobility of saline water in the forest soil and their effect on the microbial activity. Using a fire-fighting helicopter, seawater was sprayed over three plots (50 × 100 m) located on the eastern slope of the Baekdu mountain range in South Korea in April, 2011. We sampled the soil in April 4, May 20, and August 5 to determine the amount of salt that remained in the soil. The electrical conductivity value of the soil decreased to <400 μS/cm over a 1-month period. Approximately, four months after the application of seawater, the electrical conductivity value and Na+ content in all treatment plots did not significantly differ to those of the control plot, and total microbial activity also recovered to that of the control. Our results indicate that the amount of rainfall, soil physical-chemical properties, and topological factors may be a critical factor determining the mobility of saline water in forest soil.

A Study on the Effect of the Rhizobacterium, Bacillus sp. SH1RP8 and Potassium Family Polymers on the Crop Growth under Saline (염 환경 하에서 Bacillus sp. SH1RP8와 Polyacrylate Polymers가 작물 생장에 미치는 영향에 관한 연구)

  • Hong, Sun Hwa;Kim, Ji Seul;Park, Jang Woo;Lee, Eun Young
    • KSBB Journal
    • /
    • v.30 no.3
    • /
    • pp.97-102
    • /
    • 2015
  • This study aimed to evaluate the potential plantgrowth promoting effects of potassium polyacrylate, a superabsorbent polymer, and Bacillus sp. SH1RP8, a family of plant-growth-promoting bacteria. Potassium polyacrylate was selected as the polymer for use due to its high molecular weight and its ability to retain and continuously supply moisture. Plant-growth-promoting rhizobacteria (PGPR) were isolated from the soil and applied to plants growing in dry environments, such as saline conditions. The moisture absorption and retention abilities of potassium polyacrylate were evaluated at a high temperature ($50^{\circ}C$) and in a dry condition, during which time the polymer showed a water retention potential of 19606.07% after 29 days. To overcome the reaming problem in the soil environment, natural polymers (such as cellulose) were mixed with the potassium acrylate. The shoot growths of Peucedanum japonicum Thunb and Arundo donax were significantly enhanced when treated with the mixture of the isolated rhizosphere bacterium SH1RP8 and potassium polyacrylate (63.5 and 124.3%, respectively).

Effects of Aerobic/non-aerobic Starvation Periods on the Physical Characteristics of Activated Sludge and Organic Removal Efficiency in SBR (폭기/비폭기 상태의 기근기간이 활성슬러지의 물리적 특성 및 유기물 제거에 미치는 영향)

  • Oh, Hye-Ran;Kim, Sang-Soo;Moon, Byung-Hyun;Yoon, Cho-Hee
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.2
    • /
    • pp.343-348
    • /
    • 2010
  • The objective of this study was to investigate the effects of starvation periods with aerobic or non-aerobic conditions on the organic removal efficiencies and physical characteristics of activated sludge for treating saline and non-saline wastewater. During the experiment, MLSS, MLVSS, sludge volume index (SVI), floc size and fractal dimension, $COD_{Mn}$ removal efficiencies were monitored. The reductions of MLSS, MLVSS and SVI with maintaining the sludge under a non-aerobic condition during starvation periods were smaller than those under a aerobic condition. Floc size, fractal dimension and $COD_{Mn}$ removal efficiencies were less decreased under non-aerobic condition than under aerobic condition. And SVI were strongly correlated with floc size and fractal dimension. Consequently, the result showed that maintaining the activated sludge under non-aerobic starvation conditions was better strategy than that under aerobic starvation conditions as it adapted and resisted to starvation.

Electrokinetic Restoration of Saline Agricultural Land (염류집적 농경지의 전기동력학적 정화)

  • Jo, Sung-Ung;Kim, Do-Hyung;Yang, Jung-Seok;Chung, Keun-Yook;Baek, Ki-Tae
    • Journal of Soil and Groundwater Environment
    • /
    • v.17 no.4
    • /
    • pp.19-26
    • /
    • 2012
  • The influence of operation time on electrokinetic restoration was investigated to remove salts from sulfate-accumulated greenhouse soil. Operation time is directly related to the process cost, therefore, we determined the relationship between operation time and removal of salts. Nitrate and sodium were removed almost completely within 2 weeks, chloride and calcium was removed in proportion to the operation time. Sulfate was accumulated at the center of anode and cathode. The soil electrical conductivity (EC), an indicator for soil salinity, showed similar shape with the residual sulfate after electrokinetic treatment. The soil EC was not changed after 2 weeks, however, the energy consumption increased with operation time. Based on the experimental results, most salts except sulfate were removed within 2 weeks, but sulfate was not removed during same time period. For the further removal of sulfate, longer operation time is in need.