• 제목/요약/키워드: sag

검색결과 704건 처리시간 0.027초

전력계통 운전조건을 고려한 순간전압강하 추계 방법 (Method to Estimate Expected Sag Frequency Considering the Operating Condition of Power System)

  • 손정대;이계병;박창현
    • 전기학회논문지
    • /
    • 제65권3호
    • /
    • pp.382-387
    • /
    • 2016
  • This paper deals with the assessment of voltage sags regarding the variation of system operating conditions. In general, voltage sag assessment is performed by assuming the constant operating condition throughout the year. However, the assumption can lead to assessment errors in case of considerable changes of system operation condition. This paper presents a method to estimate ESF(expected sag frequency) considering the operating conditions according to the changes of power demand throughout the year.

개선된 전압 Sag 및 위상 검출기법에 의한 동적전압보상시스템 (Dynamic Voltage Restorers using Improved Voltage Sag and Phase Detection Algorithm)

  • 이재영;한운동;송양회;손진근;전희종
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.185-188
    • /
    • 2005
  • The recent growth in the use of impactive and nonlinear loads, electronic devices sensitive to power quality has caused many power quality problems. Dynamic voltage restorers(DVR) are known as the best effective and economic means to compensate for power quality problems(especially, voltage sag and swell). In this paper, we addresses the detecting algorithms of an voltage sag and phase for operating DVR. Experimental results are included to illustrate the efficacy of the proposed algorithm.

  • PDF

Sag와 Swell에 따른 계통 이상 검출에 관한 연구 (The Study of Grid Fault Detection for Sag, Swell)

  • 김민기;노용수;김준구;정용채;원충연
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.471-472
    • /
    • 2013
  • When ESS(Energy Storage System) is under normal operation, island situation can be occur because of grid accidents. When island operation occur, the system mode switches in to UPS(Uninterruptible Power Supply) mode to supply stabled load power. To decide island operation, checking grid magnitude or frequency is general. But regulation for sag and swell is required. In this paper, it proposes grid connection error detection algorithm for UPS operation when sag and swell occurs in grid, and analyzed by simulation.

  • PDF

배전계통에 분산전원 연계시 전압강하에 의한 민감부하의 피해를 고려한 보호협조 연구 (A Study on the Coordination Scheme Considering the Loss of Sensitive Load by Voltage Sag at Distribution System Interconnected Dispersed Generation)

  • 정승복;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.363-365
    • /
    • 2003
  • Recently, the concern of power qualiaty problem is increasing. Especially, Voltage quality problem have been increased important problem. Electronic device was affected by voltage sag. So, sensitive load that included many electronic Device was affected by voltage sag. also, it may have economic loss. In this paper, we argue the coordination scheme considering the loss of sensitive load. The coordination device of distribution system for instaneous fault is recloser and sectionalizer, But, the fault clearing time of recloser is more than 2 seconds. So, voltage sag generates long time that affected sensitive load. HS(high speed switchgear) has fast fault clearing time(0.015s) that not affected sensitive load. Therefore, the coordination applied HS is used. The proposed schemes are proved and evaluated by a case study using PSCAD/EMTDC simulation.

  • PDF

리클로징 시간을 고려한 배전계통 순간전압강하의 수용가측 영향 (Customer's Effects of Momentary Voltage Sag in Power Distribution System Considering Reclosing Interval)

  • 문종필;김재철;강봉석;윤상윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.36-38
    • /
    • 2003
  • In this paper, It was evaluated that the customer's effects of momentary voltage sag in power distribution system considering reclosing interval. Above all, power quality problems were discussed widely, various international standards about power quality were compared to each other. after the continuous voltage sag waves of power distribution system on fault were induced, the experimentation about voltage sag for critical load was performed using source simulator. The results of experimentation were displayed as the form of 2 and 3-dimensional CBEMA Curve.

  • PDF

3상 다이나믹 UPS의 성능 시험을 위한 Sag-Swell 발생기 (Sag-Swell Generator for the test of 3-phase Dynamic UPS)

  • 김중원;이기수;변우열;노의철;김인동;전태원;김흥근
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.514-517
    • /
    • 2004
  • This paper describes a new 3 phase Sag-Swell generator for the test of custom power devices such as UPS, DVR, DSTATCOM, SSTS, etc. The proposed scheme has good features of simple structure, high reliability wide range of sag and swell variation, It can also generate voltage outage. The control scheme for the generation is simple. The operation principle of the proposed scheme is described and verified through simulations.

  • PDF

순간전압품질이 저압 전기기기 운전한계에 미치는 특성연구 (The study on the characteristics of operating limit of low voltage electric machine under the effects of voltage quality)

  • 박인덕;정성원;김재현;이근준
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.95-97
    • /
    • 2007
  • This paper studies on operating limit curve of low voltage electric machinery with respect to source voltage variation or sag. Also, it discusses electric machine and compensation equipment design methodology based on voltage quality effect assessment technology. Voltage quality standards, such as SEMI47, CBEMA, ITIC curve are regarded to examine the relation between time constants of load and sagging time of sag generator, the load(low voltage electric machinery) study. Voltage sag characteristics of loads, time constant and sag relation voltage-time operating limits are tested and verified.

  • PDF

직접전력변환 방식의 단상 sag/swell 보상기 구현 (Implementation of Single-phase Voltage Sag/swell Compensator using Direct Power Conversion)

  • 이상회;차한주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 춘계학술대회 논문집 에너지변화시스템부문
    • /
    • pp.118-120
    • /
    • 2009
  • 본 논문에서는 직접 전력변환방식의 단상 sag/swell 보상기를 구현하였다. 제안된 보상기는 정현파 입력/ 출력 필터, 직렬연결 변압기와 dc 링크 커패시터부가 없는 단상 back-to-back PWM컨버터로 구성되어 있다. 이 보상기의 장점은 dc-link 진해 커패시터가 제거되어 전력회로부가 간단하게 구현되어 향상된 신뢰성 및 내구성을 확인 할 수 있으며 동시에 단상 전압 sag/swell을 보상하며 스위칭 손실을 줄이는 간단한 PWM 방법을 들 수 있다. 더구나, 제안된 방법은 일반적인 직접 전력변환방식에서 요구되어지는 복잡한 4-step 전류 방법이 필요 없는 간단한 전류제어방법을 채용할 수 있는 구조이며 제안된 보상기의 구조와 PWM 방법의 타당성을 프로토타입 하드웨어를 제작하여 실험결과로 보상기의 우수성을 확인하였다.

  • PDF

산불에 의해 가열된 가공송전선의 이도거동 (The SAG Behavior of Overhead Conductor due to Forest Fire)

  • 김병걸;김상수;전완기;한세원;김진한
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.516-517
    • /
    • 2007
  • Because forest fire can give a serious damage to overhead conductors, the thorough understanding about sag behavior of burned conductor is very important in maintaining the transmission line safely. Therefore, a systematic investigation was carried out by heating method. As the heating temperature increases, drastic change of tensile strength of Al wire due to the softening of Al wire occurred. When Al wire is exposed to the flame(about $800^{\circ}C$) during only 13 seconds, the remained tensile strength of Al wire showed under 90%. and then sag of overhead conductor become deteriorated. The detailed results will be given in the text.

  • PDF

장경간용 고강도 가공송전선 개발 (Development of a High Strength Conductor for Long Span)

  • 김병걸;김상수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.521-522
    • /
    • 2007
  • A new high strength conductor was designed for long span transmission line with a high nitrogen steel having high tensile strength and non-magnetic properties and high strength AI alloy. The tensile strength of conductor is very important to reduce the sag. The height of electric tower depend on the sag also. More than 36% less of sag was achieved by using ACHR(Aluminum conductor stranded high-nitrogen steel reinforced) instead of conventional ACSR.

  • PDF