• Title/Summary/Keyword: safety zone

Search Result 1,089, Processing Time 0.03 seconds

Influence of heading date difference on gene flow from GM to non-GM rices (GM벼에서 non-GM벼로 유전자 이동에 대한 개화기 차이의 영향 분석)

  • Oh, Sung-Dug;Chang, Ancheol;Kim, Boeun;Sohn, Soo-In;Yun, Doh-Won
    • Journal of the Korean Society of International Agriculture
    • /
    • v.30 no.4
    • /
    • pp.347-356
    • /
    • 2018
  • Genetically modified (GM) crops have been increased continuously over the world and concerns about the potential risks of GM crops have also been increasing. Even though GM crops have not been cultivated commercially in Korea, it should be necessary to develop the safety assesment technology for GM crops. In this study, we investigated the influence of heading date difference on gene flow from GM to non-GM rice. In the experimental plot design, The PAC GM rice was placed in the center as a pollen donor and non-GM rice were placed in eight directions as pollen receivers. Five pollen receiver rice cultivars were Unkawng, Daebo, Saegyejinmi, Nakdong-byeo, and Ilmi which had different flowering times. A total of 266,436, 300,237, 305,223, 273,373, and 290,759 seeds were collected from Unkawng, Daebo, Saegyejinmi, Nakdong, and Ilmi, respectively, which were planted around PAC GM rice. The GM${\times}$non-GM hybrids were detected by repeated spraying of herbicide and PAT immunostrip assay. Finally, the hybrids were confirmed by PCR analysis using PAC gene specific primer. The hybrids were found in Nakdong-byeo which had the same heading date with PAC GM rice. The hybridization rate was 0.0007% at Nakdong-byeo plot. All of GM${\times}$non-GM hybrids were located within 2 m distance from the PAC GM rice zone. The physiological elements including rice heading date were found to be important factors to determine GM?rice out crossing rate with GM rice. Consideration should be taken into for many factors like the physiological elements of field heading date of rice cultivars to set up the safety management guideline for prevention of GM rice gene flow.

Prediction of Species Distribution Changes for Key Fish Species in Fishing Activity Protected Areas in Korea (국내 어업활동보호구역 주요 어종의 종분포 변화 예측)

  • Hyeong Ju Seok;Chang Hun Lee;Choul-Hee Hwang;Young Ryun Kim;Daesun Kim;Moon Suk Lee
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.7
    • /
    • pp.802-811
    • /
    • 2023
  • Marine spatial planning (MSP) is a crucial element for rational allocation and sustainable use of marine areas. Particularly, Fishing Activity Protected Areas constitute essential zones accounting for 45.6% designated for sustainable fishing activities. However, the current assessment of these zones does not adequately consider future demands and potential values, necessitating appropriate evaluation methods and predictive tools for long-term planning. In this study, we selected key fish species (Scomber japonicus, Trichiurus lepturus, Engraulis japonicus, and Larimichthys polyactis) within the Fishing Activity Protected Area to predict their distribution and compare it with the current designated zones for evaluating the ability of the prediction tool. Employing the Intergovernmental Panel on Climate Change (IPCC) 6th Assessment Report scenarios (SSP1-2.6 and SSP5-8.5), we used species distribution models (such as MaxEnt) to assess the movement and distribution changes of these species owing to future variations. The results indicated a 30-50% increase in the distribution area of S. japonicus, T. lepturus, and L. polyactis, whereas the distribution area of E. japonicus decreased by approximately 6-11%. Based on these results, a species richness map for the four key species was created. Within the marine spatial planning boundaries, the overlap between areas rated "high" in species richness and the Fishing Activity Protected Area was approximately 15%, increasing to 21% under the RCP 2.6 scenario and 34% under the RCP 8.5 scenario. These findings can serve as scientific evidence for future evaluations of use zones or changes in reserve areas. The current and predicted distributions of species owing to climate change can address the limitations of current use zone evaluations and contribute to the development of plans for sustainable and beneficial use of marine resources.

Bathymetric and Topographic Changes of the Gomso-Bay Tidal Flat, West Coast of the Korean Peninsula (한반도 서해안 곰소만 갯벌의 수심 및 지형 변화)

  • Jin Ho Chang;Yong-Gil Kim;Myong Sun Lee
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.6
    • /
    • pp.552-561
    • /
    • 2023
  • The seafloor topography of Gomso Bay on the west coast of Korea was investigated using subtidal bathymetry and tidal-flat altimetry. Gomso Bay consists of 80% tidal flats and 20% subtidal zone, and is divided into an outer bay and an inner bay by the Jujincheon esturary channel. The outer bay tidal flat, has few tidal channels, has a concave topographic profile, and is characterized by the development of chenier and intertidal sand bars, giving it the appearance of gently sloping, dissipative beaches. The inner bay tidal flat has wide upper and middle tidal flats with a well-developed tidal channel system without cheniers. Moreover, the topographical cross-section between these tidal channels is convex upward, and shows the characteristics of a depositional environment greatly influenced by tidal channels and tidal action. An analysis of the horizontal movement of the tidal flat environment over the past 37 years investigating changes in the iso-depth lines in the Gomso-Bay tidal flat between 1981 and 2018 revealed that the Gomso-Bay tidal flat retreated gradually landward. As a result of analyzing the erosion and sedimentation characteristics of Gomso Bay, assuming that most of the water depth changes were due to changes in the elevation of the sea floor and sea level, an average of 1 cm (0 mm/y) of sediment was eroded in the outer bay over the past 37 years (1981-2018), In the inner bay, an average of 50 cm (14 mm/y) was deposited. Notably, the high tidal flats of the outer bay were largely eroded. Monitoring photographs of the coast showed that most of the erosion of the high tidal flats in the outer bay occurred in a short period around 1999 (probably 1997-2002), and that the erosion resulted from the erosion of sand dunes and high-tide beaches caused by temporarily greatly raised high tide levels and storms.

Medical Radiation Exposure Dose of Workers in the Private Study of the Job Function (의료기관 방사선 종사자의 직무별 개인피폭선량에 관한 연구)

  • Kang, Chun-Goo;Oh, Ki-Baek;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.3-12
    • /
    • 2011
  • Purpose: With increasing medical use of radiation and radioactive isotopes, there is a need to better manage the risk of radiation exposure. This study aims to grasp and analyze the individual radiation exposure situations of radiation-related workers in a medical facility by specific job, in order to instill awareness of radiation danger and to assist in safety and radiation exposure management for such workers. Materials and Methods: From January 1, 2010 December 31, 2010, medical practitioners working in the radiation is classified as a regular personal radiation dosimetry, and subsequently one year 540 people managed investigation department to target workers, dose sectional area, working period, identify the job function-related tasks for a deep dose, respectively, the annual average radiation dose were analyzed. Frequency analysis methods include ANOVA was performed. Results: Medical radiation workers in the department an annual radiation dose of Nuclear and 4.57 mSv a was highest, dose zone-specific distribution of nuclear medicine and in the 5.01~19.05 mSv in the high dose area distribution showed departmental radiation four of the annual radiation dose of Nuclear and 7.14 mSv showed the highest radiation dose. More work an average annual radiation dose according to the job function related to the synthesis of Cyclotron to 17.47 mSv work showed the highest radiation dose, Gamma camera Cinema Room 7.24 mSv, PET/CT Cinema Room service is 7.60 mSv, 2.04 mSv in order of intervention high, were analyzed. Working period, according to domain-specific average annual dose of radiation dose from 10 to 14 in oral and maxillofacial radiology practitioners as high as 1.01~3.00 mSv average dose showed the Department of Radiology, 1-4 years, 5-9 years, respectively, 1.01 workers~8.00 mSv in the range of the most high-dose region showed the distribution, nuclear medicine, and the 1-4 years, 5-9 years 3.01~19.05 mSv, respectively, workers of the highest dose showed the distribution of the area in the range of 10 to 14 years, Workers at 15-19 3.01~15.00 mSv, respectively in the range of the high-dose region were distributed. Conclusion: These results suggest that medical radiation workers working in Nuclear Medicine radiation safety management of the majority of the current were carried out in the effectiveness, depending on job characteristics has been found that many differences. However, this requires efforts to minimize radiation exposure, and systematic training for them and for reasonable radiation exposure management system is needed.

  • PDF

Study on the Fire Risk Prediction Assessment due to Deterioration contact of combustible cables in Underground Common Utility Tunnels (지하공동구내 가연성케이블의 열화접촉으로 인한 화재위험성 예측평가)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.1
    • /
    • pp.135-147
    • /
    • 2015
  • Recent underground common utility tunnels are underground facilities for jointly accommodating more than 2 kinds of air-conditioning and heating facilities, vacuum dust collector, information processing cables as well as electricity, telecommunications, waterworks, city gas, sewerage system required when citizens live their daily lives and facilities responsible for the central function of the country but it is difficult to cope with fire accidents quickly and hard to enter into common utility tunnels to extinguish a fire due to toxic gases and smoke generated when various cables are burnt. Thus, in the event of a fire, not only the nerve center of the country is paralyzed such as significant property damage and loss of communication etc. but citizen inconveniences are caused. Therefore, noticing that most fires break out by a short circuit due to electrical works and degradation contact due to combustible cables as the main causes of fires in domestic and foreign common utility tunnels fire cases that have occurred so far, the purpose of this paper is to scientifically analyze the behavior of a fire by producing the model of actual common utility tunnels and reproducing the fire. A fire experiment was conducted in a state that line type fixed temperature detector, fire door, connection deluge set and ventilation equipment are installed in underground common utility tunnels and transmission power distribution cables are coated with fire proof paints in a certain section and heating pipes are fire proof covered. As a result, in the case of Type II, the maximum temperature was measured as $932^{\circ}C$ and line type fixed temperature detector displayed the fire location exactly in the receiver at a constant temperature. And transmission power distribution cables painted with fire proof paints in a certain section, the case of Type III, were found not to be fire resistant and fire proof covered heating pipes to be fire resistant for about 30 minutes. Also, fire simulation was carried out by entering fire load during a real fire test and as a result, the maximum temperature is $943^{\circ}C$, almost identical with $932^{\circ}C$ during a real fire test. Therefore, it is considered that fire behaviour can be predicted by conducting fire simulation only with common utility tunnels fire load and result values of heat release rate, height of the smoke layer, concentration of O2, CO, CO2 etc. obtained by simulation are determined to be applied as the values during a real fire experiment. In the future, it is expected that more reliable information on domestic underground common utility tunnels fire accidents can be provided and it will contribute to construction and maintenance repair effectively and systematically by analyzing and accumulating experimental data on domestic underground common utility tunnels fire accidents built in this study and fire cases continuously every year and complementing laws and regulations and administration manuals etc.

Monitoring of Polycyclic Aromatic Hydrocarbon Residues in Environmental Samples in Korea (국내 PAHs 오염 우려지역의 환경 시료 중 PAHs 잔류량 모니터링)

  • Lim, Jong-Soo;Kim, Seong-Soo;Park, Dong-Sik;Joo, Jin-Ho;Lim, Chun-Keun;Hur, Jang-Hyun
    • The Korean Journal of Pesticide Science
    • /
    • v.11 no.2
    • /
    • pp.95-105
    • /
    • 2007
  • The aim of this study was to determine the residual amounts of PAHs in environmental samples such as crop, soil and water collected from paddy, upland fields and forestlands near industrial zone and/or a thermal power plant in South Korea. All of the samples were analyzed by GC-mass spectrometer. The average contents of total PAHs in soil samples were 140.2 ${\mu}g\;kg^{-1}$ and the range was from 4.3 to $662.9{\mu}g\;kg^{-1}$. The detection of benzo(a)anthracene, chrysene, benzo(b)fluoranthene, benzo(k)fluoranthene, benzo(a)pyrene and dibenzo(a,h) anthracene which have strong carcinogenecity was ranged from 14.2 to 167.8 ${\mu}g\;kg^{-1}$. The residual amounts and detection frequency of PAHs in soil samples from the iron and heavy industrial areas near Pohang and Busan were 3-folds more than those of the other areas. Amounts of PAHs in upland soil samples was 1.5 folds higher than those of paddy soil samples, suggesting that it may be related to the content of organic matter in soil. The average contents of total PAHs in crop samples were 9.7 ${\mu}g\;kg^{-1}$ which ranged from 4.5 to 52.2 ${\mu}g\;kg^{-1}$. However, the residual amounts of PAHs in water samples were not detected. These results showed that soils and crops were slightly contaminated with PAHs. Therefore, the investigation should be continued for evaluating a safety or risk assessment through expansion of regions and crops.

α-Glucosidase inhibitory activity and protease characteristics produced by Bacillus amyloliquefaciens (Bacillus amyloliquefaciens로부터 생산된 protease 특성 및 α-glucosidase 저해활성)

  • Lee, Rea-Hyun;Yang, Su-Jin;Hwang, Tae-Young;Chung, Shin-Kyo;Hong, Joo-Heon
    • Food Science and Preservation
    • /
    • v.22 no.5
    • /
    • pp.727-734
    • /
    • 2015
  • In this study, three GRAS (generally recognized as safety) strain was isolated from Doenjang and Cheonggukjang and identified as a protease-producing microorganism, following the appearance of a clear zone around its colony when cultured on a medium containing skim milk. Based on an analysis of the nucleotide sequence of 16S ribosomal RNA, the strains wereas identified as Bacillus amyloliquefaciens and wereas therefore named Bacillus amyloliquefaciens CDD5, Bacillus amyloliquefaciens CPD4, and Bacillus amyloliquefaciens CGD3. Here, we analyzed the protease and ${\alpha}$-glucosidase inhibitory activities of the three B. amyloliquefaciens strains. Among the isolated strains, B. amyloliquefaciens CGD3 exhibited the highest protease activity (9.21 U/mL, 24 hr). The protease activities of B. amyloliquefaciens CDD5 and B. amyloliquefaciens CPD4 reached 1.14 U/mL and 8.02 U/mL, respectively, at 48 hr. The proteases from the three B. amyloliquefaciens strains showed the highest activities within a pH range of 8.0-9.0 at $50^{\circ}C$, and casein was found to be the preferred substrate on evaluating enzyme activity in the substrate specificity assay. The B. amyloliquefaciens strains exhibited maximal growth when the nutrient broth medium had an initial pH within the range of 5.0-10.0, 6-9% sodium chloride (NaCl), and 5% glucose. B. amyloliquefaciens CDD5 exhibited a low ${\alpha}$-glucosidase inhibition rate (5.32%), whereas B. amyloliquefaciens CPD4 and B. amyloliquefaciens CGD3 exhibited relatively higher inhibition rates of 96.89% and 97.55%, respectively.

The assessment of Seoul City school sheriff system and developmental expansion plan - Around the righteousness proof of the security industry law application - (서울시 학교보안관 제도의 평가와 발전적 확대방안 - 경비업법 적용의 당위성 논증을 중심으로 -)

  • Lee, Sang-Hun
    • Korean Security Journal
    • /
    • no.29
    • /
    • pp.163-191
    • /
    • 2011
  • Recently, the problems in school violence did not stop on the crime between the members at the school and which developed into the invasion crime of the school caused by outsiders. The school is no more the safety zone from the crime. Particularly, in the case of the elementary school, because there are nearly no people who oppose to the outside attacker and can control this, it is the place where it is vulnerable to the invasion crime. The Metropolis of Seoul implements the School Sheriff system within the jurisdiction bureau, in the public elementary school. However, actually the School Sheriff business is being managed, never applying a rule in the Security Industry Law with the main content, that is the Security Industry Law application is excluded. Because the jurisdiction on the contract of Seoul City and operating company are run, the various issues is caused. First, since it is not being considered as a security business, the commercial liability insurance for security company has no chance to applicate when the operation company and the School Sheriff have related damage generation. So the security for the indemnification of loss of the victim is weak. Second, The task of the School Sheriff is ruled just by in the individual contracts. But it is insufficient with this thing. The related duties are required some supplement like a general rule application including the obligation of the guard in the security industry law. Third, the education of the School Sheriff needs to connect with the educational programme in the security industry law. The related professional education specially needed for the prevention of school violence ought to be reserved compensation. Forth, the citizens still demand the strengthening of police patrol for the surroundings of a school in spite of the result of Seoul City's public survey. Therefore, the active relation of cooperation with the police needs to be supported legally and institutionally with the Security Industry Law application. Fifthly, the success of the School Sheriff business can be more guaranteed with the supervision of the legal and institutional device like a the Security Industry Law application or police and all sorts of administrative execution's and etc.

  • PDF

Endoscopic Carpal Tunnel Release Using Single Portal Technique (단일 입구를 이용한 내시경적 수근관 감압술)

  • Cheon Sang-Jin;Kim Hui-Taek;Suh Kuen-Tak;Suh Jeung-Tak;Yoo Chong-Il
    • Journal of the Korean Arthroscopy Society
    • /
    • v.4 no.2
    • /
    • pp.159-165
    • /
    • 2000
  • Purpose : Endoscopic carpal tunnel release technique was developed and has being used to decrease postoperative morbidity and complications. The purpose of this study was to evaluate the clinical results and clinical usefulness of endoscopic carpal tunnel release using single portal technique. Methods and Materials : 18 carpal tunnel syndrome patients who were diagnosed by means of clinical symptoms, physical examination, and electrodiagnostic study had endoscopic carpal tunnel release using single portal technique with about 1 cm oblique wrist incision on 30 hands. And then they were followed-up and reviewed in the same way. Late results of operation were analysed by grading system according to patient's own assessments of relief of symptoms at the final fellow-up. The follow-up period ranged 6 to 13 months from surgery. Results : There were postoperative improvements with respect to clinical symptoms, physical examination, and electrodiagnostic study. 23 of 30 hands$(76.7\%)$ had complete resolution of symptoms. 27 hands$(90\%)$ were able to return to normal activities and work within 6 weeks, and 30 hands$(100\%)$ returned within 8 weeks. In grip strength study, 29 hands$(96.6\%)$ regained preoperative strength in 6 months. 12 of 22 hands$(55\%)$ had improvement with respect to thenar atrophy within 6 months. Late results were as follows . 23 hands$(76.7\%)$ was graded as excellent, 6 hands$(20\%)$ graded as good and 1 hand$(3.3\%)$ graded as fair, and there was no poor result. Conclusion : We think that endoscopic carpal tunnel release with single portal technique is technically safe and simple, if the surgeon takes step to stay within the safety zone based on local anatomy and selects an appropriate patient and that endoscopic carpal tunnel release does have advantages over open release. We agree that the surgeon must be prepared to perform an open technique, if technical difficulties arise, difficulty in introducing the device into the carpal tunnel is encountered, or the transverse fibers of the transverse carpal ligaments are not clearly seen.

  • PDF