• Title/Summary/Keyword: safety rate

Search Result 5,224, Processing Time 0.05 seconds

A Study on Improvement of Test Method of Nuclear Power Plant ESF ACS by applying Regulatory Guide 1.52 (Rev.3) (Reg. Guide 1.52(Rev.3)를 적용한 원전 ESF 공기정화계통 성능시험법 개선 연구)

  • Lee, Sook-Kyung;Kim, Kwang-Sin;Sohn, Soon-Hwan;Song, Kyu-Min;Lee, Kae-Woo;Park, Jeong-Seo;Cho, Byoung-Ho;Yoo, Byeang-Jea;Hong, Soon-Joon;Kang, Sun-Haeng
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.8 no.4
    • /
    • pp.311-318
    • /
    • 2010
  • U. S. NRC Regulation Guide 1.52 regulating ESF ACS in nuclear power plants has been revised to revision 3. To apply reduction of operability test time, allowance of alternative challenge agents for in-place leak test of HEPA filters, and upgrade of Methyl Iodide penetration acceptance criterion in activated carbon performance test suggested in Reg. Guide 1.52(Rev.3) on Yonggwang units 5 and 6 ESF ACSes, technical feasibility study was carried out with on-site experiments as well as experiments with a lab-scale model. It was confirmed that the moisture in the system returned to the level before the test in 1 or 4 days even though the moisture was removed during the operability test lasting more than 10 hours. Therefore, it is appropriate to perform monthly operability test in 15 minutes just long enough to check the operability of equipment. To change challenge material for in-place HEPA filter leak test, size of aerosol, production rate, and leak detection capability were compared for DOP and PAO. It was concluded that PAO can be substituted for DOP in nuclear power plants. The upgrade of Methyl Iodide penetration acceptance criterion from 0.175 % to 0.5 % in active carbon filter bed deeper than 4 inches was to conform to the change of activated carbon performance test method to ASTM D3803(1989). It was confirmed that Methyl Iodide penetration acceptance criterion of 0.5 % under $30^{\circ}C$, relative humidity 95 % condition was conservatively good enough for testing performance of active carbon insitu. The licence change of Yonggwang units 5 and 6 has been completed based on this study.

The Efficacy and Effect of Reverse Geometry Contact Lens on Cornea (역기하학 렌즈의 유효성과 각막에 미치는영향)

  • Kim, Kwang-Bae;Kim, Young-Hoon;Bark, Sang-Bai;Sun, Kyung-Ho;Jeong, Youn-Hong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.2
    • /
    • pp.1-12
    • /
    • 2007
  • Object of this research is to estimate the effect of myopia correction and safety on reverse geometry contact lens fitting in school children. This research include 53(106eyes) schoolchildren among 7 to 18 years who has low to moderate myopia(-1.00D~-5.00D) and prescribed reverse geometry contact lens for purpose on orthokeratology between January to July 2004 and had 3months full follow up examination. They were tested for slit lamp examinations, BUT(Break up time), direct ophthalmoscopy, retinoscopy, uncorrected visual acuity, best corrected visual acuity, autorefraction, autokeratometry and corneal topography in each examination(1day, 1week, 2weeks, 1, 2, and 3months) of before-and-after lens wearing to find out the effect of myopic correction and side effect. The results came out as follow. The average of uncorrected visual acuity was $0.0938{\pm}0.378$ before lens wear and $0.3136{\pm}0.283$ after 1day lens wear, and there was fast improvement after 1week($0.7925{\pm}0.301$) and little improvement after 2weeks period but still they shows better uncorrected visual acuity(p<0.01). The result of this study, the reverse geometry lens is very useful to correct refractive error and control the progression of myopia temporally among low to moderate myopic patient. The side effects were relatively rare but further study should be necessary with long term lens wear effect on eye health. For the lens prescription, the clinical fitting process had higher rate of success with consideration of eccentricity and corneal topography.

  • PDF

Monitoring of Pesticide Residues on Dried Agricultural Products (건조채소류의 잔류농약 실태 조사)

  • Gang, Gyungri;Mun, Sujin;Kim, Gwang-Gon;Yang, Yongshik;Lee, Semi;Choi, Euna;Ha, Dongryong;Kim, Eunsun;Cho, Baesik
    • The Korean Journal of Pesticide Science
    • /
    • v.21 no.1
    • /
    • pp.49-61
    • /
    • 2017
  • The study was conducted for safety evaluation of 208 kinds of residue pesticides on 200 dried agricultural products, which are distributed in Gwangju. The method of monitoring was the second of Multi Class Pesticide Multi-residue Methods in Korean Food Code, and GC-ECD, GC-NPD, GC-MSD, and LC-MS/MS were used as evaluation equipment to analyze. The residue level in pesticides were 15.5% (31 of 200 samples) and 4 samples exceeded MRLs. 4.5 mg/kg of pyraclostrobin (MRL; 3.0 mg/kg) was detected in red pepper, 1.49 mg/kg of chlorpyrifos (MRL; 0.13 mg/kg) in daikon leaves, 38.26 mg/kg of pyridalyl (MRL; 0.25 mg/kg) in pepper leaves, 0.98 mg/kg of chlorpyrifos (MRL; 0.05 mg/kg), respectively. Pesticides were found on the 15 samples among the 21 samples of red pepper which is a fruit vegetable, and this resulted in high detection rate of 71%. In addition, pesticides were detected on chwinamul, shitake, siler divaricata, daikon leaves and others within MRLs. The frequent detected kinds of pesticides were insecticide (47.6%), fungicide (33.3%), acaricide (14.3%), nematicide (4.8%) in the order named, and pesticides were methoxyfenozide > pyraclostrobin > azoxystrobin, chlorantraniprole > novaluron, trifloxystrobin in frequent order.

Structural Behavior of Mixed $LiMn_2O_4-LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ Cathode in Li-ion Cells during Electrochemical Cycling

  • Yun, Won-Seop;Lee, Sang-U
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.5-5
    • /
    • 2011
  • The research and development of hybrid electric vehicle (HEV), plug-in hybrid electric vehicle (PHEV) and electric vehicle (EV) are intensified due to the energy crisis and environmental concerns. In order to meet the challenging requirements of powering HEV, PHEV and EV, the current lithium battery technology needs to be significantly improved in terms of the cost, safety, power and energy density, as well as the calendar and cycle life. One new technology being developed is the utilization of composite cathode by mixing two different types of insertion compounds [e.g., spinel $LiMn_2O_4$ and layered $LiMO_2$ (M=Ni, Co, and Mn)]. Recently, some studies on mixing two different types of cathode materials to make a composite cathode have been reported, which were aimed at reducing cost and improving self-discharge. Numata et al. reported that when stored in a sealed can together with electrolyte at $80^{\circ}C$ for 10 days, the concentrations of both HF and $Mn^{2+}$ were lower in the can containing $LiMn_2O_4$ blended with $LiNi_{0.8}Co_{0.2}O_2$ than that containing $LiMn_2O_4$ only. That reports clearly showed that this blending technique can prevent the decline in capacity caused by cycling or storage at elevated temperatures. However, not much work has been reported on the charge-discharge characteristics and related structural phase transitions for these composite cathodes. In this presentation, we will report our in situ x-ray diffraction studies on this mixed composite cathode material during charge-discharge cycling. The mixed cathodes were incorporated into in situ XRD cells with a Li foil anode, a Celgard separator, and a 1M $LiPF_6$ electrolyte in a 1 : 1 EC : DMC solvent (LP 30 from EM Industries, Inc.). For in situ XRD cell, Mylar windows were used as has been described in detail elsewhere. All of these in situ XRD spectra were collected on beam line X18A at National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory using two different detectors. One is a conventional scintillation detector with data collection at 0.02 degree in two theta angle for each step. The other is a wide angle position sensitive detector (PSD). The wavelengths used were 1.1950 ${\AA}$ for the scintillation detector and 0.9999 A for the PSD. The newly installed PSD at beam line X18A of NSLS can collect XRD patterns as short as a few minutes covering $90^{\circ}$ of two theta angles simultaneously with good signal to noise ratio. It significantly reduced the data collection time for each scan, giving us a great advantage in studying the phase transition in real time. The two theta angles of all the XRD spectra presented in this paper have been recalculated and converted to corresponding angles for ${\lambda}=1.54\;{\AA}$, which is the wavelength of conventional x-ray tube source with Cu-$k{\alpha}$ radiation, for easy comparison with data in other literatures. The structural changes of the composite cathode made by mixing spinel $LiMn_2O_4$ and layered $Li-Ni_{1/3}Co_{1/3}Mn_{1/3}O_2$ in 1 : 1 wt% in both Li-half and Li-ion cells during charge/discharge are studied by in situ XRD. During the first charge up to ~5.2 V vs. $Li/Li^+$, the in situ XRD spectra for the composite cathode in the Li-half cell track the structural changes of each component. At the early stage of charge, the lithium extraction takes place in the $LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ component only. When the cell voltage reaches at ~4.0 V vs. $Li/Li^+$, lithium extraction from the spinel $LiMn_2O_4$ component starts and becomes the major contributor for the cell capacity due to the higher rate capability of $LiMn_2O_4$. When the voltage passed 4.3 V, the major structural changes are from the $LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ component, while the $LiMn_2O_4$ component is almost unchanged. In the Li-ion cell using a MCMB anode and a composite cathode cycled between 2.5 V and 4.2 V, the structural changes are dominated by the spinel $LiMn_2O_4$ component, with much less changes in the layered $LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ component, comparing with the Li-half cell results. These results give us valuable information about the structural changes relating to the contributions of each individual component to the cell capacity at certain charge/discharge state, which are helpful in designing and optimizing the composite cathode using spinel- and layered-type materials for Li-ion battery research. More detailed discussion will be presented at the meeting.

  • PDF

The Initial Growth of Scirpus planiculmis and its Herbicidal Response for the Screening (Screening을 위한 새섬매자기(Scirpus planiculmis) 초기생육(初期生育) 및 제초제(除草劑) 반응성(反應性))

  • Hwang, I.T.;Choi, J.S.;Lee, B.H.;Hong, K.S.;Cho, K.Y.
    • Korean Journal of Weed Science
    • /
    • v.14 no.4
    • /
    • pp.245-251
    • /
    • 1994
  • The initial growth and herbicidal responses of Scirpus planiculmis were examined under both laboratory and greenhouse condition. Initial growth of S. planiculmis at two different soils(soil A and B), was compared with the growth at normal paddy soil, and growth rates at two soils were 32% and 86% as compared to the growth rates at normal paddy soil. Two different soils were soil A(rice-uncultivable) and soil B(rice-cultivable). Transplanted(2.5 leaf stage) and direct seeded rice(Dongjinbyeo) could not grow at soil A. The growth of transplanted rice at soil B was almost same as the growth at normal paddy soil, but the growth of direct seeded rice was 50% of the growth at normal paddy soil. S. planiculmis among the perennial weeds was most tolerant to NaCl, and Cyperus serotinus, Eleocharis kuroguwai, Sagittaria pygmaea, Sagittaria trifolia, Potamogeton distinctus were followed. The intial growth rate of S. planiculmis was more rapid than C. serotinus. Cutting types and times of corm reduced 20-40% of the initial growth of S. planiculmis. During the initial growth of S. planiculmis, the growth of S. planiculmis was severly inhibited by the earlier removal of corm from seedlings, and it represents that the corm plays an important role in the initial growth of this species. Bentazone among 14 commercialized herbicides showed the best safety on direct seeded rice and the highest control effect agaist S. planiculmis.

  • PDF

Bond Characteristics and Splitting Bond Stress on Steel Fiber Reinforced Reactive Powder Concrete (강섬유로 보강된 반응성 분체 콘크리트의 부착특성과 쪼갬인장강도)

  • Choi, Hyun-Ki;Bae, Baek-Il;Choi, Chang-Sik
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.5
    • /
    • pp.651-660
    • /
    • 2014
  • Structural members using ultra high strength concrete which usually used with steel fiber is designed with guidelines based on several investigation of SF-RPC(steel fiber reinforced reactive powder concrete). However, there are not clear design method yet. Especially, SF-RPC member should be casted with steam(90 degree delicious) and members with SF-RPC usually used with precast members. Although the most important design parameter is development method between SF-RPC and steel reinforcement(rebar), there are no clear design method in the SF-RPC member design guidelines. There are many controversial problems on safety and economy. Therefore, in order to make design more optimum safe design, in this study, we investigated bond stress between steel rebar and SF-RPC according to test. Test results were compared with previously suggested analysis method. Test was carried out with direct pull out test using variables of compressive strength of concrete, concrete cover and inclusion ratio of steel fiber. According to test results, bond stress between steel rebar and SF-RPC increased with increase of compressive strength of concrete and concrete cover. Increasing rate of bond stress were decrease with increase of compressive strength of SF-RPC and concrete cover significantly. 1% volume fraction inclusion of steel fiber increase the bond stress between steel rebar and SF-RPC with two times but 2% volume fraction cannot affect the bond stress significantly. There are no exact or empirical equations for evaluation of SF-RPC bond stress. In order to make safe bond design of SF-RPC precast members, previously suggested analysis method for bond stress by Tepfers were evaluated. This method have shown good agreement with test results, especially for steel fiber reinforced RPC.

Performance Evaluation of Advance Warning System for Transporting Hazardous Materials (위험물 운송을 위한 조기경보시스뎀 성능평가)

  • Oh Sei-Chang;Cho Yong-Sung
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.4 no.1 s.6
    • /
    • pp.15-29
    • /
    • 2005
  • Truck Shipment Safety Information, which is a part of the development of NERIS is divided into Optimal Route Guidance System and Emergency Response System. This research is for establishing an advance warning system, which aims for preventing damages(fire, explosion, gas-escape etc.) and detecting incidents that are able to happen during transporting hazardous materials in advance through monitoring the position of moving vehicles and the state of hazardous materials in real-time. This research is peformed to confirm the practical possibility of application of the advance warning system that monitors whether the hazardous materials transport vehicles move the allowed routes, finds the time and the location of incidents of the vehicles promptly and develops the emergency system that is able to respond to the incidents as well by using the technologies of CPS, CDMA and CIS with testing the ability of performance. As the results of the test, communication accuracies are 99$\%$ in freeway, 96$\%$ in arterial, 97$\%$ in hilly sections, 99$\%$ in normal sections, 96$\%$ in local sections, 99$\%$ in urban sections and 98$\%$ in tunnels. According to those results, the system has been recorded a high success rate of communication that enough to apply to the real site. However, the weak point appeared through the testing is that the system has a limitation of communication that is caused in the rural areas and certain areas where are fewer antennas that make communication possible between on-board unit and management server. Consequently, for the practical use of this system, it is essential to develop the exclusive en-board unit for the vehicles and find the method that supplements the receiving limitation of the GPS coordinates inside tunnels. Additionally, this system can be used to regulate illegal acts automatically such as illegal negligence of hazardous materials. And the system can be applied to the study about an application scheme as a guideline for transporting hazardous materials because there is no certain management system and act of toxic substances in Korea.

  • PDF

Improvement of Heat Pump Heating Performance by Selective Heat Storage Using Air Heat of Inside and Outside Greenhouse (온실 내외부 공기열의 선택적 축열에 의한 히트펌프 난방성능 개선)

  • Kwon, Jin Kyung;Kim, Seung Hee;Jeon, Jong Gil;Kang, Youn Koo;Jang, Kab Yeol
    • Journal of Bio-Environment Control
    • /
    • v.26 no.4
    • /
    • pp.353-360
    • /
    • 2017
  • In this study, the design and performance test of the air to water heat pump capable of producing hot water for greenhouse heating by using the surplus solar heat inside the greenhouse and the air heat outside greenhouse as the selective heat source were conducted. The heat storage operations using the surplus solar heat and the outside air heat were designed to be switched according to the setting temperature of the greenhouse in consideration of the optimum temperature range of the crop. In the developed system, it was possible to automatically control the switching of heat storage operation, heating and ventilation by setting 12 reference temperatures on the control panel. In the selective heat storage operation with the surplus solar heat and outside air heat, the temperature of thermal storage tank was controlled variably from $35^{\circ}C$ to $52^{\circ}C$ according to the heat storage rate and heating load. The heat storage operation times using the surplus solar heat and outside air heat were 23.1% and 30.7% of the experimental time respectively and the heat pump pause time was 46.2%. COP(coefficient of performance) of the heat pump of the heat storage operation using the surplus solar heat and outside air heat were 3.83 and 2.77 respectively and was 3.24 for whole selective heat storage operation. For the comparative experiment, the heat storage operation using the outside air heat only was performed under the condition that the temperature of the thermal storage tank was controlled constantly from 50 to $52^{\circ}C$, and COP was analyzed to be 2.33. As a result, it was confirmed that the COP of the heat storage operation using the surplus solar heat and outside air heat as selective heat source and the variable temperature control of the thermal storage tank was 39% higher than that of the general heat storage operation using the outside air heat only and the constant temperature control of the thermal storage tank.

Tow-Year Follow-up Study for Clinical Feature and Immunity of The Children, Vaccinated by 47 Passaged Oka Strain Live Attenuated Varicella Vaccine (47계대 Oka주 약독화 생백신 접종 후 2년간 임상 및 면역성의 추적 연구)

  • Kang, Jin Han;Kim, Jong Hyun;Hur, Jae Kyun;Woo, Koo
    • Pediatric Infection and Vaccine
    • /
    • v.7 no.1
    • /
    • pp.129-135
    • /
    • 2000
  • Purpose : We previously reported the short-term immunogenecity and safety of 47 passaged Oka strain live attenuated varicella vaccine in healthy children in 1997. Now, we conducted this two-year follow-up study to confirm the maintenance of immunity, the occurrence of natural varicella infection and the activation of vaccine induced latent infection on the same vaccine. Methods : 99 children who had been immunized by 47 passaged Oka strain live attenuated varicella vaccine in 1997 were followed up by questionnaire, and 46 children out of study group were followed up serologically. They were asked to report any instance of varicella or herpes zoster since they had been immunized. If there was any evidence of varicella or herpes zoster, they should be clinically or serologically confirmed by doctor. Also, those patients' parents were asked to report any instance of varicella or herpes zoster in their family, playmate, kindergarten, school, or other settings. The immunity to VZV was confirmed by EIA and FAMA test. Results : 6 recipients developed breakthrough varicella after exposure to VZV in family, kindergarten and school during follow-up period. However, clinical features of those patients were very mild and self limited without therapy. And none of the recipients developed herpes zoster during this observation period. The results of EIA test showed that study subjects were all seropositive except one, and the antibody titers and GMT of FAMA test were seropositively maintained in all subjects. Statistically, the antibody titers of EIA and FAMA test confirmed two years after vaccination were higher than those results confirmed one month after vaccination. Conclusion : Our study results suggest that the immunity of 47 passaged Oka strain live attenuated varicella is well maintained until 2 years later after vaccination, and mild natural infection after exposure to VZV can be occurred with low rate. There were not developing zoster in study vaccine after vaccination for two-years.

  • PDF

Immunogenicity, Reactogenicity and Safety of a Combined DTPa-IPV Vaccine Compared with Separate DTPa and IPV Vaccines in Healthy Korean Infants (한국의 건강한 영아를 대상으로 DTPa-IPV 혼합백신을 접종한 경우와 DTPa 백신과 IPV 백신을 각각 투여하였을 경우의 면역원성, 반응원성 및 안전성)

  • Kim, Chang Hwi;Cha, Sung Ho;Shin, Son Moon;Kim, Chun Soo;Choi, Young Youn;Hong, Young Jin;Chey, Myoung Jae;Kim, Kwang Nam;Hur, Jae Kyun;Jo, Dae Sun;Kim, Sung Shin;Lee, Sang Lak;Song, Eun Song;Ramakrishnan, Gunasekaran;Ok, Jin Ju;Van Der Meeren, Olivier;Bock, Hans L.;Kim, Jung Soo
    • Pediatric Infection and Vaccine
    • /
    • v.17 no.2
    • /
    • pp.156-168
    • /
    • 2010
  • Purpose : To compare immunogenicity and reactogenicity of a combined diphtheria-tetanus-acellular pertussis-inactivated poliovirus vaccine (DTPa-IPV, $Infanrix^{TM}$ IPV, GlaxoSmithKline Biologicals) with co-administration of commercially available DTPa and IPV vaccines at separate injection sites (DTPa+IPV). Methods : A total of 458 infants aged 8-12 weeks were randomized to receive three-ose primary vaccination at 2, 4 and 6 months with DTPa-IPV or DTPa+IPV. Blood samples were collected pre and post vaccination for measurement of immune responses. Reactogenicity was assessed following each dose using diary cards. Results : One month post-dose 3, seroprotection rates for anti-diphtheria, anti-tetanus and anti-poliovirus types 1, 2 and 3 were ${\geq}99.5%$ and vaccine response rates to pertussis antigens were at least 98.6% in both DTPa-IPV and DTPa + IPV groups. Non-inferiority between the groups was demonstrated based on pre-defined statistical criteria. Incidences of both local and systemic symptoms were within the same range across both groups with grade 3 symptoms reported following no more than 4.3% of DTPa-IPV doses and 4.5% of DTPa + IPV doses. Two serious adverse events (both pyrexia) after DTPa-IPV administration were considered vaccine-related. Both infants recovered fully. Conclusion : Combined DTPa-IPV vaccine was immunogenic and well tolerated when used as a three-dose primary vaccination course in Korean infants. DTPa-IPV could be incorporated into the Korean vaccination schedule, reducing the number of injections required to complete primary immunization.