• 제목/요약/키워드: safety rate

Search Result 5,194, Processing Time 0.029 seconds

Heat Release Characteristics of Typical Live Fire Load in Large Bookstore (대형서점 적재가연물의 초기 연소발열성상)

  • Nam, Dong-Gun
    • Fire Science and Engineering
    • /
    • v.25 no.2
    • /
    • pp.88-94
    • /
    • 2011
  • Heat release characteristics of live fire load are an important parameter for performance oriented fire safety design of a building. While investigations have been carried out on the fire load and its burning behavior in office, residential and commercial buildings and so on, little effort has been paid for the rational treatment of fire load in bookstore. In this report, burning behavior of typical combustible objects in bookstore are studied by measuring heat release rates of bookshelf with book. Based on the results, it has reviewed fire safety when a fire accident occurs on the large bookstore and suggested peak heat release rate per burning surface, fire growth rate, etc of the live fire load required for fire safety design in bookstore.

RCD success criteria estimation based on allowable coping time

  • Ham, Jaehyun;Cho, Jaehyun;Kim, Jaewhan;Kang, Hyun Gook
    • Nuclear Engineering and Technology
    • /
    • v.51 no.2
    • /
    • pp.402-409
    • /
    • 2019
  • When a loss of coolant accident (LOCA) occurs in a nuclear power plant, accident scenarios which can prevent core damage are defined based on break size. Current probabilistic safety assessment evaluates that core damage can be prevented under small-break LOCA (SBLOCA) and steam generator tube rupture (SGTR) with rapid cool down (RCD) strategy when all safety injection systems are unavailable. However, previous research has pointed out a limitation of RCD in terms of initiation time. Therefore, RCD success criteria estimation based on allowable coping time under a SBLOCA or SGTR when all safety injection systems are unavailable was performed based on time-line and thermal-hydraulic analyses. The time line analysis assumed a single emergency operating procedure flow, and the thermal hydraulic analysis utilized MARS-KS code with variables of break size, cooling rate, and operator allowable time. Results show while RCD is possible under SGTR, it is impossible under SBLOCA at the APR1400's current cooling rate limitation of 55 K/hr. A success criteria map for RCD under SBLOCA is suggested without cooling rate limitation.

A study on stability of rear side armor with maximum overtopping (최대월파량의 발생에 따른 사석방파제 배후면 피복석의 안정성에 관한 연구)

  • Ryu, Cheong-Ro;Kim, Hong-Jin;Cheoi, Jong-Wook;Kim, Heon-Tae
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.121-127
    • /
    • 2003
  • Wave overtopping is one of the most important hydraulic responses of breakwater because it significantly affects its functional efficiency, the safety of transit and mooring on the rear side, wave transmission in the sheltered area, rear side armor stones and to some extent, the structural safety itself. In this study, hydraulic model tests has been carried out to investigate the influence of berm's size on overtopping rate by maximum overtopping rate and mean overtopping rate. The hydrodynamic characteristics of berm breakwater by the overtopping rate can be summarized as follows: 1. It is better to use maximum overtopping rate than to use mean overtopping rate for design of coastal structures in the point of view of stability. 2. When construct berm to decrease energy of waves that it was needed to make breaking conditions of wave on the berm. 3. Under the relative length of berm was over 0.13 overtopping rate was significantly decreased. 4. Overtopping rate affected significantly by the relative length of yhe berm than height of the berm.

  • PDF

A Health and Safety Improvement Roadmap for the Construction Industry

  • Diugwu, Ikechukwu A.;Baba, Dorothy L.
    • Journal of Construction Engineering and Project Management
    • /
    • v.4 no.1
    • /
    • pp.37-44
    • /
    • 2014
  • Comparatively, the construction industry has, on average, a higher rate of fatal and major injuries, work induced ill-health and damage to properties than other industrial sectors; and this is a source of concern to industry stakeholders. The study showed that although subcontracting could be contributory to an increase in workplace accidents in the construction industry, contractual aspects of subcontracting arrangements (such as the power imbalance that exist along the client-customer interface) also present opportunities for improvements in health and safety management (HSM) practices in organisations. This conclusion was reached after an analysis of a questionnaire survey (with a 27% response rate) that assessed the attitudes and perception to health and safety issues.

Trust-based Relay Selection in Relay-based Networks

  • Wu, Di;Zhu, Gang;Zhu, Li;Ai, Bo
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.6 no.10
    • /
    • pp.2587-2600
    • /
    • 2012
  • It has been demonstrated that choosing an appropriate relay node can improve the transmission rate for the system. However, such system improvement brought by the relay selection may be degraded with the presence of the malicious relay nodes, which are selected but refuse to cooperate for transmissions deliberately. In this paper, we formulate the relay selection issue as a restless bandit problem with the objective to maximize the average rate, while considering the credibility of each relay node, which may be different at each time instant. Then the optimization problem is solved by using the priority-index heuristic method effectively. Furthermore, a low complexity algorithm is offered in order to facilitate the practical implementations. Simulation results are conducted to demonstrate the effectiveness of the proposed trust-based relay selection scheme.

Safety Critical I&C Component Inventory Management Method for Nuclear Power Plant using Linear Data Analysis Technic

  • Jung, Jae Cheon;Kim, Haek Yun
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.16 no.1
    • /
    • pp.84-97
    • /
    • 2020
  • This paper aims to develop an optimized inventory management method for safety critical Instrument and Control (I&C) components. In this regard, the paper focuses on estimating the consumption rate of I&C components using demand forecasting methods. The target component for this paper is the Foxboro SPEC-200 controller. This component was chosen because it has highest consumption rate among the safety critical I&C components in Korean OPR-1000 NPPs. Three analytical methods were chosen in order to develop the demand forecasting methods; Poisson, Generalized Linear Model (GLM) and Bootstrapping. The results show that the GLM gives better accuracy than the other analytical methods. This is because the GLM considers the maintenance level of the component by discriminating between corrective and preventive.

Analysis of Performance and Development of Environment-friendly High Expansion Foam Concentrate (친환경 고발포 소화약제 개발 및 성능 분석 연구)

  • Kim, Ha-Young;Nam, Jun-Seok;Rie, Dong-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.4
    • /
    • pp.25-29
    • /
    • 2010
  • Foam concentrate is used for fire-extinguishing purposes, occurring foam, mixed with air. In huge oil-fire or the efficiency of fire-extinguishing with small quantity of water, Foam concentrate is used widely. However, perfluorooc tanoicsulfonate and nonylpenol that are included in Foam concentrate could be exposure in danger while they were discharged. The purpose of the research is the development of environment-friendly high expansion foam that exclude the dangerous substances and improvement of danger of the existing foam concentrate. The developed foam is analyzed as the environment-friendly foam in indexes of the environment-toxicity, the biodegradation appraisal, and the dangerous substances-detecting. In addition, the performances of expansion rate, discharge rate, and fire-extinguishing are suitable in the domestic regulation, so it is useful for fire-extinguishing in real fire situation.

A Safety Assessment Methodology for a Digital Reactor Protection System

  • Lee Dong-Young;Choi Jong-Gyun;Lyou Joon
    • International Journal of Control, Automation, and Systems
    • /
    • v.4 no.1
    • /
    • pp.105-112
    • /
    • 2006
  • The main function of a reactor protection system is to maintain the reactor core integrity and the reactor coolant system pressure boundary. Generally, the reactor protection system adopts the 2-out-of-m redundant architecture to assure a reliable operation. This paper describes the safety assessment of a digital reactor protection system using the fault tree analysis technique. The fault tree technique can be expressed in terms of combinations of the basic event failures such as the random hardware failures, common cause failures, operator errors, and the fault tolerance mechanisms implemented in the reactor protection system. In this paper, a prediction method of the hardware failure rate is suggested for a digital reactor protection system, and applied to the reactor protection system being developed in Korea to identify design weak points from a safety point of view.

Improvement for practical application of Risk Assessment in shipbuilding industry (조선업 위험성평가 실용을 위한 개선 방안)

  • Shin, Woonchul
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.3
    • /
    • pp.273-277
    • /
    • 2014
  • Subcontracting business than the contracting business in shipbuilding industry is a lot of hazardous job and highly accident because of highly work intensity. In order to prevent the accidents, there is a need to analyze characteristic. of shipbuilding, to apply measures of risk assessment. In this paper, I suggested an improvement of the risk assessment through the actual condition research in shipbuilding industry. In the research method, I analysed accidents occurred until 2011-2013. Carried out the actual site survey while two weeks in May 2014. As a result, 1) The main pattern were caught-in or between, fall on the high level according to analyzed accidents. 2) To apply the weight show clear of magnitude for risk assessment. 3) Risk estimation of risk assessment is desirable to be quantization by accidents analysis, and to be greater than or equal to 4 steps.