• Title/Summary/Keyword: safety monitoring system

Search Result 1,475, Processing Time 0.029 seconds

A Study on Model of the State's Aviation Safety Management System (국가 통합항공안전관리시스템 모형 구축에 관한 연구)

  • Park, Min-Kyu
    • Journal of the Korea Safety Management & Science
    • /
    • v.13 no.2
    • /
    • pp.1-8
    • /
    • 2011
  • The Chicago Convention in 1944 made important contributions to aviation safety improvement, building an aviation safety monitoring system for its signatory countries. As ICAO is now on the verge of changing its supervision system from self-reporting to preventive Continuous Monitoring Approach(CMA) in 2013, we also expect our own safety system to make a progress accordingly. The government is pushing ahead with plans to build an integrated safety management system at government level that satisfies international standards and reflects domestic features. To this end, this report proposes the most effective system-building model, by analyzing the current status of the system that is in use and meets the requirements of international aviation agencies.

Developing a Safety Scaffold Monitoring System Using Wireless Sensor Network Technology

  • Tserng, H. Ping;Huang, Hung-Jui;Li, Xin-Yan;Huang, Han-Tang
    • International conference on construction engineering and project management
    • /
    • 2015.10a
    • /
    • pp.324-327
    • /
    • 2015
  • Scaffold is the most commonly used equipment in various types of construction works. Since various types of construction works use the same scaffold equipment, it becomes more difficult to be controlled and managed, thus resulting hazard frequently. According to the information announced in July 2012 by Council of Labor Affairs Executive Yan, the site collapse or incomplete anti-falling protection has led the site to accident frequently, and this is the main reason that causes construction industry occupational disasters. The labor death occupational hazard ratio rises up to 13% in scaffold activity, and the Council of Labor Affairs Executive Yan has showed that the death ratio is higher when using the scaffold in construction site, the total number of death has reached to 139 from 2005 to 2010. In order to ensure the safety of scaffold user, this study tends to build a wireless sensor monitoring system to detect the reliability and safety of the scaffold. The wireless sensor technique applies in this study is different with the traditional monitoring technique which is limited with wired monitoring. Wireless sensor technique does not need wire, it just needs to consider the power supply for establishing the network and receiving stable information, and it can become a monitoring system. In addition, this study also integrates strain gauge technique in this scaffold monitoring system, to develop a real-time monitoring data transfer mechanism and replace the traditional wired single project monitoring equipment. This study hopes to build a scaffold collapse monitoring system to effectively monitor the safety of the scaffold as well as provide the timesaving installation, low-cost and portable features.

  • PDF

Design of PTZ Camera-Based Multiview Monitoring System for Efficient Observation in Vessel Engine Room (선박 기관실의 효율적인 감시를 위한 PTZ 카메라 기반의 멀티뷰 모니터링 시스템 설계)

  • Kim, Heon-Hui;Hong, Sang-Jun;Nam, Taek-Kun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.7
    • /
    • pp.1129-1136
    • /
    • 2021
  • A pan-tilt-zoom (PTZ) camera-based monitoring system for efficient monitoring in the engine room of a vessel was designed. A number of places exist where traditional analog instruments are still used in vessel engine rooms, and blind spots closely related to safety exist, for which flooding or fire is a concern. A camera-based monitoring system that guarantees a wide range at a relatively fast cycle for these monitoring points can be an effective alternative to enhance the safety of a vessel. Therefore, a multiview monitoring system is proposed in which the functions of the existing PTZ camera are further strengthened using a software. The monitoring system comprises four modules: camera control, location registration, traversal control, and multiview image reconstruction. The effectiveness of the method was evaluated through a series of experiments in an engine room environment.

A Numerical Study to Analyze Safety of Pressure Leakage Monitoring System of Gas Extinguishing Agent (가스소화약제 압력누기감시장치의 안전성 분석을 위한 수치적 연구)

  • Go, A-Ra;Lim, Dong-Oh;Son, Bong-Sei
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.103-110
    • /
    • 2016
  • While the demand for the gas system fire extinguishers increases every year, there are insufficient safety measures for assessing the extinguishing performance, such as system safety and reliability in the preparation of increasing demand, which has emerged as a social problem. One of the most critical causes of accidents occurring with the gas extinguishing system is pressure leakage from the extinguishing agent storage container. This is considered to be one of the critical factors on which the success of fire suppression depends. In this study, its safety measure was studied, Because it was deemed urgently necessary. The newly developed pressure leakage monitoring system is a system monitoring storage condition, pressure, leakage and discharge of the storage container related to agent concentration, which is one of the critical factors for fire suppression. This was developed to be applicable to the $CO_2$ and HFC-23 systems. Therefore, for structural safety analysis, the safety performance was verified by the fluid structure coupling analysis of the safety problems that may occur when the pressure leakage monitoring system is applied to the gas fire extinguisher. For analysis programs, the FloEFD program from Mentor Graphics was used for computational fluid dynamics analysis and ABAQUS from Dassault Systems was used for structural analysis. From the result of numerical analysis, the structure of $CO_2$ did not develop plastic deformation and its safety was verified. However, plastic deformation and deviation issue occurred with the HFC-23 monitoring system and therefore verified the structural safety of pressure leakage monitoring system by data obtained from redesigning and adjusting the condition of numerical interpretation three times.

A Study on the Improvement of Subcontractors' Safety Management System in Construction Industries (건설업 협력회사 안전수준 향상 방안에 관한 연구)

  • Lee, Jae Yun;Oh, Tae Keun
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.2
    • /
    • pp.78-84
    • /
    • 2017
  • Subcontractors have an increased risk of accidents compared to large contractors. Subcontractors' safety management system is in close association with workers in construction sites. Contractors should strengthen subcontractors' roll and responsibility and provide continual support to prevent an accident. And also these supporting system should be provided to subcontractors' headquarters as well as construction site. Contractors' priority management for subcontractors safety should be transferred from the post management for disciplinary action to the preventive management to improve subcontractors participation and safety performance. Subcontractors can not establish the safety management system with just a one time supporting only. Contractors support and monitoring should be provided to subcontractors regularly and continuously to establish their self safety management system. The subcontractors safety management system improvement program(SSMSIP) suggested in this study will be a effective supporting system for subcontractors to establish and improve their safety management system. If we carry out the objective and quantitative evaluations and supporting system such as SSMSIP and provide the consequential incentive program to subcontractors, it can contribute to the accident reduction.

Development of Safety Monitoring System for Operating Railway Tunnel (운용중인 철도터널의 안전관리 시스템 시범구축)

  • Lee, Su-Hyung;Shin, Min-Ho;Kim, Hyun-Ki
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.73-78
    • /
    • 2008
  • There has been need for safety monitoring systems for the social infrastructures. These infrastructures are subject to degradation over time, reduced functionality, and loss of functionality as a result of factors such as a wide variety of installation environments, natural disasters, and nearby work. Therefore, it is necessary to perform appropriate inspections, repairs, and renovations to ensure safe and efficient maintenance and operation. This paper introduces the example of the development of the safety monitoring system for operating railway tunnel. Tunnel profile measuring system using laser beam, crack gauges, accelerometer and a pluviometer were implemented to monitor the safety of a deteriorated tunnel. The measured data were transferred through wireless network and analyzed in real time. The safety criteria for tunnel stabilities and train operations are also discussed.

  • PDF

Development of Tank Lorry Monitoring System for Safety Using Intelligent Computing Device (지능형 단말기를 사용한 탱크로리 운행 안전 모니터링 시스템 개발)

  • Lee, Choon-Young;Bae, Ki-Man;Park, Geun-Young;Lee, Dong-Jin;Lim, Jeong-Sik;Lee, Sang-Ryong
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.2
    • /
    • pp.42-47
    • /
    • 2008
  • It is important for national safety that tank lorry or bulk lorry which is carrying toxic gas or explosive materials should be monitored during the maneuvering from starting point to destination as well as vehicle or tank status. Therefore, we propose a safety monitoring system for tank lorry to check driving condition and the vehicle status. We studied the integration of central control system with in-vehicle computer system connected with various sensors for monitoring through a communication network.

  • PDF

The Results of the Application of a Real-time Chemical Exposure Monitoring System in a Workplace (스마트 센서 세트를 활용한 화학물질 상시모니터링 시스템의 작업현장 적용 결과)

  • Wook Kim;Jangjin Ryoo;Jongdeok Jung;Gwihyun Park;Giyeong Kim;Jinju Kang;Kihyo Jung;Seunghon Ham
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.2
    • /
    • pp.215-229
    • /
    • 2023
  • Objectives: To validate the effectiveness of a real-time chemical exposure monitoring system developed by KOSHA (Korea Occupational Safety and Health Agency), we applied the system to a workplace in the electronics industry for 153 days. Methods: The monitoring system consisted of a PID chemical sensor, a LTE communication equipment, and a web-based platform. To monitor chemical exposure, four sets of sensors were placed in two manufacturing tasks - inspection and jig cleaning - which used TCE as a degreasing agent. We reviewed previous reports of work environment measurements and conducted a new work environment measurement on one day during the period. The PID sensor systems detected the chemical exposure levels in the workplace every second and transmitted it to the platform. Daily average and maximum chemical exposure levels were also recorded. Results: We compared the results from the real-time monitoring system and the work environment measurement by traditional methods. Generally, the data from the real-time monitoring system showed a higher level because the sensors were closer to the chemical source. We found that 28% of jig cleaning task data exceeded the STEL. Peak exposure levels of sensor data were useful for understanding the characteristics of the task's chemical use. Limitations and implications were reviewed for the adoption of the system for preventing poisoning caused by chemical substances. Conclusions: We found that the real-time chemical exposure monitoring system was an efficient tool for preventing occupational diseases caused by chemical exposure, such as acute poisoning. Further research is needed to improve the reliability and applicability of the system. We also believe that forming a social consensus around the system is essential.

Web-based Real Time Failure Diagnosis System Development for Induction Motor Bearing (유도전동기 베어링의 원거리 실시간 결함진단시스템 개발)

  • Kwon, Oh-Heon;Lee, Seung-Hyun
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.3 s.71
    • /
    • pp.1-8
    • /
    • 2005
  • The industrial induction motor is widely used in the rotating electrical machine for the transmission of power. It is very reliable equipment, but it could lead to the loss of production and lift when failure occurs. Therefore, the failure data is acquired and analyzed by attaching an exclusive instrument to existing induction motor. However, these instruments could lead to side effects, increasing the production costs, because they are very expensive. The purpose of this study is the development of an induction motor bearing failure diagnosis system constructed using LabVIEW which can be supplied the kernelled function, process monitoring and current signature analysis. In addition, the availability and reasonability of the constructed system was examined for an induction motor with failure defects in outer raceway and ball bearing. From the results, it shows that failure diagnosis system constructed is useful for real-time monitoring with detection of bearing defects over the web.

A Safety Evaluation Strategy Employing Bridge Health Monitoring System by Traffic Loads (교량 상시계측시스템을 이용한 실시간 안전성평가시스템 구축 방안)

  • Lee, Woo-Sang;Joo, Bong-Chul;Park, Ki-Tae
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.481-484
    • /
    • 2008
  • The research was carried out to suggest the bridge health monitoring systems that have been composed damage detection algorithm and a system for evaluation load carrying capacity of bridge by traffic loads for the purpose of safety management of bridge structure in efficient and economic.

  • PDF