• Title/Summary/Keyword: safety limits

Search Result 901, Processing Time 0.034 seconds

Feasibility Study of Underground LNG Storage System in Rock Cavern (LNG 지하공동 비축시스템의 타당성분석)

  • Chung, So-Keul;Han, Kong-Chang;Park, Eui-Seob
    • Tunnel and Underground Space
    • /
    • v.16 no.4 s.63
    • /
    • pp.296-306
    • /
    • 2006
  • It is difficult to solve problems regarding the adjustment on demand and supply of LNG due to seasonal variations of domestic demand of LNG, a discordance among import pattern and limits of storage facilities and so on. Also, there may be instability in LNG supply due to chances of accidents at LNG producing areas. Therefore, it is very important to secure large LNG storage facilities and to stabilize LNG supply management on a long term basis. The objective of this study is to examine the real-scale applicability of a lined underground rock storage system, which have been verified by a successful operation of the Daejeon LNG pilot plant. The new technology has many advantages of better economy, safety and environment protection, for above-ground and in-ground storage systems. The results of this study may promote the first ever real scale underground LNG storage system in a rock cavern.

Safety Evaluation of Lead and Cadmium in Colored Plastic Kitchenwares (합성수지제 주방용품의 납, 카드뮴 안전성 평가)

  • Yoon Mi-Hye;Eom Mi-Na;Do Young-Sook;Jung Hong-Rae;Jeong Il-Heoung;Ko Hoan-Uck;Son Jin-Seok
    • Journal of environmental and Sanitary engineering
    • /
    • v.19 no.3 s.53
    • /
    • pp.65-70
    • /
    • 2004
  • This study was peformed to survey and evaluate contents of Pb and Cd in colored plastic kitchenwares by Korea Food Sanitation Act. The tested samples were 160 products(32 PE, 65 PP, 10 PS, 18 ABS and 35 MF) in a local market. The Pb and Cd contents range in the samples were $ND\~357.1mg/kg\;and\;ND\~376.6mg/kg$. Pb contents in 6 samples(1 PE, 1 PP, 2 PS and 2 MF) and Cd contents of 2 samples(1 PE and 1 ABS) were above the legal limits. Among the illegal smples, Pb contents were 140.8mg/kg, 283.4mg/kg, 134.0mg/kg, 329.2mg/kg, 357.1mg/kg and 218.3mg/kg, respectively and Cd contents were 123.1mg/kg and 376.6mg/kg. Pb and Cd in various food simulants were not detected in migration test for illegal samples. Simulants were tested at $25^{\circ}C\;and\;60^{\circ}C$ for n-heptane and $4\%$ acetic acid, and $60^{\circ}C\;and\;95^{\circ}C$ for water.

Palm-Size-Integrated Microwave Power Module at 1.35-GHz for an Atmospheric Pressure Plasma for biomedical applications

  • Myung, C.W.;Kwon, H.C.;Kim, H.Y.;Won, I.H.;Kang, S.K.;Lee, J.K.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.498-498
    • /
    • 2013
  • Atmospheric Pressure Plasmas have pioneered a new field of plasma for biomedical application bridging plasma physics and biology. Biological and medical applications of plasmas have attracted considerable attention due to promising applications in medicine such as electro-surgery, dentistry, skin care and sterilization of heat-sensitive medical instruments [1]. Traditional approaches using electronic devices have limits in heating, high voltage shock, and high current shock for patients. It is a great demand for plasma medical industrial acceptance that the plasma generation device should be compact, inexpensive, and safe for patients. Microwave-excited micro-plasma has the highest feasibility compared with other types of plasma sources since it has the advantages of low power, low voltage, safety from high-voltage shock, electromagnetic compatibility, and long lifetime due to the low energy of striking ions [2]. Recent experiment [2] shows three-log reduction within 180-s treatment of S. mutans with a low-power palm-size microwave power module for biomedical application. Experiments using microwave plasma are discussed. This low-power palm-size microwave power module board includes a power amplifier (PA) chip, a phase locked loop (PLL) chip, and an impedance matching network. As it has been a success, more compact-size module is needed for the portability of microwave devices and for the various medical applications of microwave plasma source. For the plasma generator, a 1.35-GHz coaxial transmission line resonator (CTLR) [3] is used. The way of reducing the size and enhancing the performances of the module is examined.

  • PDF

Establishment of Pre-Harvest Residue Limits (PHRLs) of Fungicide Fenarimol and Insecticide Flufenoxuron in Peaches during Cultivation Period (복숭아 재배기간 중 살균제 Fenarimol과 살충제 Flufenoxuron의 생산단계 잔류허용기준 설정)

  • Moon, Hye-Ree;Park, Jae-Hoon;Yoon, Ji-Yeong;Na, Eun-Shik;Lee, Kyu-Seung
    • Korean Journal of Environmental Agriculture
    • /
    • v.32 no.2
    • /
    • pp.136-141
    • /
    • 2013
  • BACKGROUND: This study was performed to establishment the PHRLs of peach during cultivation period, and also to estimate biological half-lives for residues of fenarimol and flufenoxuron. METHODS AND RESULTS: The extracted samples of fenarimol were analyzed by GC-ECD and the flufenoxuron extracted samples were analyzed by HPLC-DAD. Recoveries of fenarimol at two fortification levels of 0.1 mg/kg, 0.5 mg/kg were $93.69{\pm}6.56$(%) and $94.45{\pm}1.60$ (%), respectively. And recoveries of flufenoxuron at two fortification levels of 0.1 mg/kg, 0.5 mg/kg were $106.73{\pm}5.90$(%) and $96.37{\pm}6.66$(%), respectively. CONCLUSION(S): The biological half-lives of fenarimol in single treatment and triple treatment were 3.5day and 3.8day. that of Flufenoxuron was also 7.1day and 4.9day, respectively. The PHRL of fenarimol were recommended as 1.5 mg/kg for 10day before harvest and the PHRL of flufenoxuron were recommended as 1.4 mg/kg for 10day before harvest.

A Study on the Reliability of the Combustible Properties for Acrylic Acid (아크릴릭산의 연소특성치의 신뢰성 연구)

  • Ha, Dong-Myeong
    • Journal of Energy Engineering
    • /
    • v.24 no.3
    • /
    • pp.20-26
    • /
    • 2015
  • For the reliability of the combustible properties of arylic acid, this study was investigated the explosion limits of acrylic acid in the reference data. The flash points and AITs(auto-ignition temperatures) by ignition delay time were experimented. The lower flash points of acrylic acid by using Setaflash and Pensky-Martens closed-cup testers were experimented in $48^{\circ}C$ and $51^{\circ}C$, respectively. The lower flash points of arylic acid by using Tag and Cleveland open cup testers were experimented in $56^{\circ}C$. This study measured relationship between the AITs and the ignition delay times by using ASTM E659 tester for acrylic acid. The AIT of acrylic acid was experimented as $417^{\circ}C$. The lower explosion limit(LEL) and the upper explosion limit(UEL) by the measured the lower flash point and the upper flash point of acrylic acid were calculated as 2.2 Vol% and 7.9 Vol%, respectively.

A Study for Stamping of Patchwork with Resistance Spot Weld (저항 점용접에 의한 실러 패치워크 적용 판재 프레스 성형 연구)

  • Lee, Gyeong-Min;Jung, Chan-Yeong;Song, Il-Jong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.8
    • /
    • pp.25-31
    • /
    • 2018
  • Recently, research on the development of lightweight vehicle bodies is increasing continuously as a response to fuel economy regulations. To reduce the weight of a vehicle body, a conventional steel plate has been substituted by light weight material with high specific strength and the jointing of multi-materials is generally applied. On the other hand, the customer's demand for safety and emotional quality in NVH (Noise, Vibration and Harshness) is becoming increasingly important. Therefore, a light weight with proper strength and NVH quality is needed. In the view of light weighting and NVH quality, the application of a vibration proof steel plate can be an effective solution but the formability of a sandwich panel is different with a conventional steel sheet. Therefore, careful analysis of formability is required. This study aims to characterize the formability of a sandwich high-strength steel plate. The high-strength steel plates of different thicknesses with resistance spot welding and sealer bonding were analyzed using forming limits diagram through a cup drawing test.

A correlation method for high-frequency response of a cargo during dry transport in high seas

  • Vinayan, Vimal;Zou, Jun
    • Ocean Systems Engineering
    • /
    • v.6 no.2
    • /
    • pp.143-159
    • /
    • 2016
  • Cargo, such as a Tension Leg Platform (TLP), Semi-submersible platform (Semi), Spar or a circular Floating Production Storage and Offloading (FPSO), are frequently dry-transported on a Heavy Lift Vessel (HLV) from the point of construction to the point of installation. The voyage can span months and the overhanging portions of the hull can be subject to frequent wave slamming events in rough weather. Tie-downs or sea-fastening are usually provided to ensure the safety of the cargo during the voyage and to keep the extreme responses of the cargo, primarily for the installed equipment and facilities, within the design limits. The proper design of the tie-down is dependent on the accurate prediction of the wave slamming loads the cargo will experience during the voyage. This is a difficult task and model testing is a widely accepted and adopted method to obtain reliable sea-fastening loads and extreme accelerations. However, it is crucial to realize the difference in the inherent stiffness of the instrument that is used to measure the tri-axial sea fastening loads and the prototype design of the tie-downs. It is practically not possible to scale the tri-axial load measuring instrument stiffness to reflect the real tie-down stiffness during tests. A correlation method is required to systematically and consistently account for the stiffness differences and correct the measured results. Direct application of the measured load tends to be conservative and lead to over-design that can reflect on the overall cost and schedule of the project. The objective here is to employ the established correlation method to provide proper high-frequency responses to topsides and hull design teams. In addition, guidance for optimizing tie-down design to avoid damage to the installed equipment, facilities and structural members can be provided.

Low-Earth orbit satellite constellation for ADS-B based in-flight aircraft tracking

  • Nguyen, Thien H.;Tsafnat, Naomi;Cetin, Ediz;Osborne, Barnaby;Dixon, Thomas F.
    • Advances in aircraft and spacecraft science
    • /
    • v.2 no.1
    • /
    • pp.95-108
    • /
    • 2015
  • Automatic Dependent Surveillance Broadcast (ADS-B) is quickly being adopted by aviation safety authorities around the world as the standard for aircraft tracking. The technology provides the opportunity for live tracking of aircraft positions within range of an ADS-B receiver stations. Currently these receiver stations are bound by land and local infrastructural constraints. As such there is little to no coverage over oceans and poles, over which many commercial flights routinely travel. A low cost space based ADS-B receiving system is proposed as a constellation of small satellites. The possibility for a link between aircraft and satellite is dependent primarily on proximity. Calculating the likelihood of a link between two moving targets when considering with the non-periodic and non-uniform nature of actual aircraft flight-paths is non-trivial. This analysis of the link likelihood and the performance of the tracking ability of the satellite constellation has been carried out by a direct simulation of satellites and aircraft. Parameters defining the constellation (satellite numbers, orbit size and shape, orbit configuration) were varied between reasonable limits. The recent MH370 disappearance was simulated and potential tracking and coverage was analysed using an example constellation. The trend of more satellites at a higher altitude inclined at 60 degrees was found to be the optimal solution.

Study on the Well Scenario of the LILW Disposal Facility in Korea (중·저준위 방사성폐기물 처분시설의 우물 이용 시나리오를 적용한 안전평가 연구에 대한 고찰)

  • Jeong, Mi-Seon;Cheong, Jae-Yeol;Park, Jin Beak
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.13 no.1
    • /
    • pp.63-72
    • /
    • 2015
  • The low and intermediate-level radioactive waste generated in Korea is disposed of at Wolsong Disposal Facility. For the safety of a disposal facility, it must be assessed by considering some abnormal scenarios including human intrusion as well as those by natural phenomena. The human intrusion scenario is a scenario that an incognizant man of the disposal facility will be occurred by the drilling. In this paper, the well usage scenario was classified into the human intrusion event as the probability of the well drilling is very low during the man's lifecycle and then was assessed by using conservative assumptions. This scenario was assessed using the dilution factor of contaminants released from a disposal facility and then it was introduced the applied methodology in this study. The assessed scenario using this methodology is satisfied the regulatory limits.

A Study on Frequency Sharing of Fixed Satellite Service with Microwave Landing System (고정위성업무와 마이크로파착륙장치 간의 주파수 공유 연구)

  • Jun, Byung-Kyu;Kang, Ji-Han;Lim, Sang-Seok;Lee, Jae-Wook;Oh, Dae-Sub;Gam, Hye-Mi
    • Journal of Advanced Navigation Technology
    • /
    • v.15 no.1
    • /
    • pp.11-17
    • /
    • 2011
  • In this paper, we consider the frequency sharing feasibility of Fixed Satellite Service (FSS) with Microwave Landing System (MLS) allocated in the C-band. On the basis of characteristics of MLS and FSS suggested by ITU and safety standards of MLS by ICAO, three interference scenarios are built and numerical simulations are carried out for investigating the frequency sharing between the two systems. From the simulation results, we calculate the separation distance between MLS and FSS ground antennas, required for frequency sharing by employing standard protection limits regulating the interference to noise ratio (I/N) of the receiver.