• Title/Summary/Keyword: safety inspection criteria

Search Result 131, Processing Time 0.023 seconds

DEVELOPMENT AND EVALUATION OF THE MUON TRIGGER DETECTOR USING A RESISTIVE PLATE CHAMBER

  • Park, Byeong-Hyeon;Kim, Yong-Kyun;Kang, Jeong-Soo;Kim, Young-Jin;Choi, Ihn-Jea;Kim, Chong;Hong, Byung-Sik
    • Journal of Radiation Protection and Research
    • /
    • v.36 no.1
    • /
    • pp.35-43
    • /
    • 2011
  • The PHENIX Experiment is the largest of the four experiments that have taken data at the Relativistic Heavy Ion Collider. PHENIX, the Pioneering High Energy Nuclear Interaction eXperiment, is designed specifically to measure direct probes of the collisions such as electrons, muons, and photons. The primary goal of PHENIX is to discover and study a new state of matter called the Quark-Gluon Plasma. Among many particles, muons coming from W-boson decay gives us key information to analyze the spin of proton. Resistive plate chambers are proposed as a suitable solution as a muon trigger because of their fast response and good time resolution, flexibility in signal readout, robustness and the relatively low cost of production. The RPC detectors for upgrade were assembled and their performances were evaluated. The procedure to make the detectors better was optimized and described in detail in this thesis. The code based on ROOT was written and by using this the performance of the detectors made was evaluated, and all of the modules for north muon arm met the criteria and installation at PHENIX completed in November 2009. As RPC detectors that we made showed fast response, capacity of covering wide area with a resonable price and good spatial resolution, this will give the opportunity for applications, such as diagnosis and customs inspection system.

Sanitation Management Practices of Food Delivery Companies that Supply Food to School Foodsevice establishments (학교급식 식재료 유통업체의 위생관리 실태)

  • Kim, Yun-Hwa;Lee, Yeon-Kyung
    • Food Science and Preservation
    • /
    • v.17 no.6
    • /
    • pp.889-896
    • /
    • 2010
  • We evaluated the sanitation management practices in food delivery companies that supply food and food ingredients to school food-service establishments. We examined the practices 38 food delivery companies located in the Daegu and Gyeongbuk areas of Korea. Sanitation management practices were self-evaluated using a Likert 5-point scale. The total mean score for delivery company sanitation performance was 4.45. Scores for perceived sanitation management performance of the delivery companies were: food ingredient storage and management (4.47); delivery worker (4.47); and management of delivery van (4.38). The personal hygiene score was significantly higher than those of other sanitation inspection items evaluated (p<0.05). Delivery company managers believed that their sanitation management programs kept food hygienically and that the food was delivered to a high level of safety and at optimal quality. However, the managers thought that food quality standardization was needed to ensure transparency in delivery. Food delivery companies wish to obtain sanitation and supply certifications if they meet certain criteria.

A Study on Safety Management Inspection of Diagnostic X-ray System (진단용 엑스선 장치의 안전관리 검사에 관한 연구)

  • Lee, Hoo min;Kim, Hyeon ju
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.887-893
    • /
    • 2018
  • The purpose of this study is to compare the performance of X-ray generators installed in hospitals and universities and apply the quality control items of diagnostic X-ray generators to recognize the importance of periodic performance management. First, the reproducibility and linearity test results showed that the PAE of the reproducibility evaluation was high for the GX-650 devices that met the acceptance criteria in all the experimental conditions and lacked the periodic quality control. In the linearity evaluation, when the tube voltage was set to 100 kVp, It was measured to deviate from the error. In addition, it was found that the PAE in the low-accuracy evaluation results relative to an X-ray tube voltage and tube current of the device low occurrence frequency. The HVL experiment was included in all of the devices at the HVL by tube voltage. Therefore, it is necessary to recognize the importance of quality control of all devices rather than hospital and laboratory, and to manage the device performance by actively managing the device, and to establish a short - term quality control system like special medical devices.

GIS Management on Risk Evaluation of a Road Slope Using Terrestrial LiDAR (지상 LiDAR를 활용한 접도사면 위험평가에 따른 GIS관리)

  • Jang, Yong Gu;Kwak, Young Joo;Kang, In Joon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.1D
    • /
    • pp.169-175
    • /
    • 2006
  • Recently, slope failures are disastrous when they occur in mountainous area adjoining highways. The accidents associated with slope failures have increased due to rapid urbanization of mountainous area. Therefore, the inspection of slope is conducted to maintain road safety as well as road function. In this study, we apply to the remedy which is comparing existent description to advanced technology using GIS. We utilize a Terrestrial LiDAR, one of the advanced method, to generate precise and complete road slope model from expert point of view. In result, we extract hazardous slope information from external measurements referring to the evaluation criteria of external slope stability. We suggest not only the database but also the method of road risk evaluation based on internet GIS.

Flexural Tensile Strength of Concrete Block Masonry (비보강 콘크리트 조적조의 휨인장강도)

  • Kim, Young-Sang
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.9 no.4
    • /
    • pp.119-126
    • /
    • 2005
  • The objective of this paper is to evaluate the flexural tensile strength of unreinforced concrete masonry wall to ensure the structural safety in out-of-plane behaviors under the wind or earthquake loads. Flexural tensile strength of unreinforced concrete masonry wall has been obtained from the full scale tests of total 327 specimens and the statistical analysis are performed for each of the cases. The flexural tensile strength derived from experiments is classified as 13 groups according to masorny units, mortar ingredients, and the direction of tensile stresses and the mean tensile strength and the variable coefficient are obtained for each case. The uniform and concentrated transverse loads have been applied over the face of the wall specimens. The ultimate mean flexural tensile strengths are distributed from 1,564 kPa to 363 kPa according to masonry units, mortar ingredients, and other factors. The allowable flexural tension stress criteria will be established based on the mean flexural tensile strengths in the future.

Quantitative Fire Risk Assessment and Counter Plans Based on FDS and GIS for National Road Bridges (FDS와 GIS를 이용한 교량 화재 위험도의 정량적 평가 및 적용방안)

  • Ann, Ho June;Park, Cheol Woo;Kim, Yong Jae;Jang, Young Ik;Kong, Jung Sik
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.6
    • /
    • pp.185-195
    • /
    • 2017
  • In recent years, unexpected bridge fire accidents have increased because of augmenting the number of traffic volumes and hazardous materials by the increment in traffics and distribution business. Furthermore, in accordance with the effort of using the under space of bridges, the ratio of occupied by combustible materials like oil tanker or lorry has been increased. As a result, the occurrence of bridge fire has been growing drastically. In order to mitigate the accident of bridge fire, risk assessment of bridge fire has been studied, however, practical risk models considering safety from users' viewpoints were scarce. This study represented quantitative risk assessment model applicable to national road bridges in Korea. The primary factors with significant impacts on bridge fire accidents was chosen such as clearance height, materials of bridges, arrival time of fire truck and fire intensity. The selected factors were used for Fire Dynamics Simulation (FDS) and the peak temperature calculated by FDS in accordance with the fire duration and fire intensity. The risk assessment model in bridge fire reflected the FDS analysis results, the fire damage criteria, and the grade of fire truck arrival time was established. Response plans for bridge fire accidents according to the risk assessment output has been discussed. Lastly, distances between bridges and fire stations were calculated by GIS network analysis. Based on the suggested assessment model and methodology, sample bridges were selected and graded for the risk assessment.

Analyses of Structural Performances for Reinforced Concrete Middle-Rise Residential Building under Construction (중층 규모 철근콘크리트 주거형 건물의 시공 중 구조성능 분석)

  • Ko, Jun-Young;Kim, Jae-Yo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.5
    • /
    • pp.96-103
    • /
    • 2019
  • Middle-rise reinforced concrete residential buildings account for a large portion of the Korea, and structural performance analysis are needed for problems that could occur during the construction of such buildings. Thus, a middle-rise reinforced concrete residential building with 25 stories are selected as a sample model for structural performance analysis. The structural analyses are performed by dividing a sample model into the construction stage models of the 5th, 10th, 15th, 20th and 25th floors and the completion stage models with the design completed. For the comparisons of structural performances, Eigenvalue analysis results and lateral-load-resisting capabilities and structural design performances of structural members are analyzed. As a result of analyses, it was confirmed that both the construction and completion stage do not exceed KBC criteria limits at the lateral displacement and story drift ratio, and structural design performances of structural members confirm structural safety in all components except for some members of the wall. Therefore, it was concluded that if structural stability is obtained during the completion stage of a middle-rise reinforced concrete residential building, structural stability is secured under construction.

Relationship between the Tidal Range in Sea Level and Damage of Domestic Port Facility (해수면 조위차와 항만시설물의 손상과의 관계 분석)

  • Binna Lee;Jong Suk Lee;Sung Jin Lee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.6
    • /
    • pp.55-61
    • /
    • 2023
  • In this study, a basic research was conducted to establish a maintenance plan considering the environmental factors and deterioration characteristics of port facilities. The precise safety diagnosis reports for Incheon and Busan port facilities were referenced to examine the extent of deterioration and damage. The relationship with the degradation environmental assessment presented in the current guidelines was also analyzed. The analysis of the damage level of Incheon and Busan port facilities revealed that Incheon Port exhibited approximately three times higher damage rate compared to Busan Port. In the case of Incheon Port, reinforcement corrosion and external damage showed similar proportions, while in Busan Port, reinforcement corrosion had a higher proportion compared to external damage. On the other hand, when comparing with the degradation environmental assessment presented in the guidelines, it was found that there were some limitations in performing quantitative evaluation based on the guidelines for assessing port facilities. Therefore, an analysis based on tidal range was conducted by referring to existing literature. The analysis of tidal range in Incheon and Busan regions showed that Incheon had approximately five times higher difference compared to Busan. It is considered that this can be utilized as a differentiated item from existing degradation environmental assessment criteria.

Risk Analysis Method for Deriving Priorities for Detailed Inspection of Small and Medium-sized Fill Dam (중소형 필댐의 정밀점검 우선순위 도출을 위한 간이 위험도 분석 방법)

  • Kim, Jinyoung;Kang, Jaemo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.21 no.10
    • /
    • pp.11-16
    • /
    • 2020
  • Korea's agricultural reservoir is one of the country's major infrastructures and plays an important role in people's lives. However, aging reservoirs are a risk for life and property. Currently, large and small dams and reservoirs have been constructed nationwide for more than 40 years of aging. Dams and reservoirs built nationwide are managed by various institutions. Therefore, it is difficult to manage all dams and reservoirs due to cost and time. Managers in the field with less management personnel and lack of expertise should be able to quickly identify risk factors for multiple reservoirs. In this study, risk factors such as seepage, leakage, settlement slide, crack and erosion were selected. To assess the risk of the items, we used the analytical hierarchical process (AHP), one of the Multi-Criteria Decision Making (MCDM) methods. The analysis showed that seepage has the greatest impact on reservoir collapse. It is judged that the priority of detailed diagnosis can be determined by evaluating the risk of dam reservoir collapse in a convenient way in advance using the calculated weight.

Quality Control Tests and Acceptance Criteria of Diagnostic Radiopharmaceuticals (진단용 방사성의약품의 품질관리시험 및 기준)

  • Park, Jun Young
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.53 no.1
    • /
    • pp.1-10
    • /
    • 2021
  • Radiopharmaceuticals are drugs that contain radioisotopes and are used in the diagnosis, treatment, or investigation of diseases. Radiopharmaceuticals must be manufactured in compliance with good manufacturing practice regulations and subjected to quality control before they are administered to patients to ensure the safety of the drug. Radiopharmaceuticals for administration to humans need to be sterile and pyrogen-free. Hence, sterility tests and membrane filter integrity tests are carried out to confirm the asepticity of the finished drug product, and a bacterial endotoxin test conducted to assess contamination, if any, by pyrogens. The physical appearance and the absence of foreign insoluble substances should be confirmed by a visual inspection. The chemical purity, residual solvents, and pH should be evaluated because residual by-products and impurities in the finished product can be harmful to patients. The half-life, radiochemical purity, radionuclidic purity, and strength need to be assessed by analyzing the radiation emitted from radiopharmaceuticals to verify that the radioisotope contents are properly labeled on pharmaceuticals. Radiopharmaceuticals always carry the risk of radiation exposure. Therefore, the time taken for quality control tests should be minimized and care should be taken to prevent radiation exposure during handling. This review discusses the quality control procedures and acceptance criteria for a diagnostic radiopharmaceutical.