• Title/Summary/Keyword: safety hazards

Search Result 947, Processing Time 0.031 seconds

A risk management methodology for maritime logistics and supply chain applications

  • Mokhtari, Kambiz;Ren, Jun
    • Ocean Systems Engineering
    • /
    • v.4 no.2
    • /
    • pp.137-150
    • /
    • 2014
  • In the marine industry although there has been significant growth towards safety, security and risk assessments or risk-based strategies such as marine insurance and regulations to avoid the risks of damage to properties and the environment or the prospect of premature death caused by accidents etc, the moves toward managing the risks which are linked directly to the business functions and decision making processes have been very slow. Furthermore in the marine industry most perceptions, methodologies and frameworks of dealing with hazards, risks, safety and security issues are for their assessment rather than their management. This trend reveals the fact that in different marine industry sectors such as logistics and shipping there is a lack of coherent risk management framework or methodology from which to understand the risk-based decisions especially for the purpose of design, construction, operation, management and even decommissioning of the marine related applications. On the other hand risk management is not yet viewed holistically in the marine industry in order to, for example, assign a right person, i.e. risk manager, who can act as a coordinator and advisor with responsibilities that are only specific to risk management. As a result this paper, by examining the present physical borders and risk-based activities in the marine industry, aims to propose an appropriate risk management methodology in addition to the emergent role of risk managers which will enable the industry users initially to become familiar with the concept of risk management at its holistic level. In the later stages this eventually can lead to development of risk management capabilities at an exclusive level and its integration into the marine industry functions in future.

Current Status of Tire Recycling in Taiwan

  • Shanshin Ton;Taipau Chia;Lee, Ming-Huang;Chien, Yeh-Chung;Shu, Hung-Yee
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.230-235
    • /
    • 2001
  • There are more than 15 millions cars or motors in Taiwan. According to the statistics from Environmental Protection Administration, the number of resulting scrap tires are near 110 thousand tons each year. The tire recycle programs in Taiwan were first conducted in 1989 and executed by ROC Scrap Tire Foundation. However, the current efficiency of the tire recycling industry still needs to be improved to minimize the environmental problem or fire hazards caused by scrap tires storage. Ten major tire-recycling factories are surveyed in this study. The investigations include the source of scrap tire, the shredding process, the market of products, the management of wastes disposal, and the difficulties of these sectors. As the varieties of the shredding machines of the recycle factories, there are three kinds of final products which include powder, granular, and chips. The wastes, wires and fibers, produced by the shredding process are the major problems fur all the factories. The percentage of the wire and fiber removal from rubbers still needs to be increased. The best approaches found in this study to increase the efficiency of scrap tire recycling processes are proposed which include the improvement of magnetic separation system fiber/rubber separation system and the minimization of waste disposal. A categorized standard of the processing outputs is suggested as a reference for the decision-making of the tire-recycling factories.

  • PDF

Design and Development of Signal Transmitting POD for Aircraft Application (항공기용 신호 송출 POD의 설계 및 개발)

  • Kim, Jee-heung;Kwak, Young-kil;Kim, Kichul;Park, Joo-rae
    • Journal of Advanced Navigation Technology
    • /
    • v.24 no.1
    • /
    • pp.1-8
    • /
    • 2020
  • In this research, we develop an airborne equipment radiating S/C-band signal to a target located at a long distance. RF interface of the equipment comprises band-specific transmitters and an broadband antenna to satisfy EIRP(effective isotropic radiated power) requirements. The equipment is in a shape of a POD like an aircraft fuel tank. The measured weight of the equipment is 119.8 kg, the CG(center of gravity) is 1391.35 mm and the MOI(moment of inertia) are 46.07 ± 0.05(Iyy) kg·㎡, 45.36 ± 0.09(Izz) kg·㎡. All results are found to meet the requirements for aircraft installation. To verify flight safety, EMI(electromagnetic interference) tests (RE102, CE102), environmental tests (high/low temperature operation, altitude), intra-system EMC(electromagnetic compatibility) and HERP(hazards electromagnetic radiation personnel) tests have been conducted and all the test results met the requirements. It is confirmed that the equipment could be mounted on the aircraft by meeting all electrical and mechanical requirements.

Analysis of Microbial Contaminants and Microbial Changes during Dried-laver Pyropia spp. Processing (마른김(Pyropia spp.) 가공 공정 경과에 따른 미생물 오염도 분석)

  • Kwon, Kion;Ryu, Dae-Gyu;Jeong, Min-Chul;Kang, Eun-Hye;Jang, Yumi;Kwon, Ji Young;Kim, Jeong-Mok;Shin, Il-Shik;Kim, Young-Mog
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.51 no.1
    • /
    • pp.8-14
    • /
    • 2018
  • We investigated the levels of microbial contaminants and microbial hazards during dried-laver processing. We analyzed 321 samples obtained from 18 dried-laver Pyropia spp. manufacturing facilities, including water, swab-, and processing samples as well as final products. The levels of microbial contaminants, including viable cell counts (VCC) and coliform bacteria, increased as processing progressed. The sanitary indicator bacterium, Escherichia coli, was not detected in the final products although VCC levels were high, generally exceeding 5 log CFU/g. We also investigated changes in microbial contaminants at each processing step. Both VCC and total coliform dramatically increased after 4 days of continuous processing, indicating that microbial contaminants originated, mainly, from cross contamination during processing.

Changes of egg Quality according to eggshell treatment and storage condition (계란의 난각 처리와 보관 방법에 따른 품질 변화)

  • Lee Sung-Mo;Hong Chong-Hae
    • Korean Journal of Veterinary Service
    • /
    • v.28 no.3
    • /
    • pp.225-234
    • /
    • 2005
  • Egg has been considered as one of the most important food sources in both nutritionally and economically. However, because the hazards of egg flow chains' complexity from producers to consumers and the insufficiency of cold chain systems in Korea are still remained, preventive measures for egg safety should be established. This experiment was carried out to investigate the changes of egg qualify during storage in order to find out the proper storage condition and eggshell treatment. Eggs were stored at cold condition $(5^{\circ}C,\;relative\;humidity;\;RH:\;65\pm3\%)$ and room Condition $(1st: Sep\; 6\~Nov\; 15,\;2001,\; 10\~30^{\circ}C,\;RH\;41\~86\%,\;2nd;\; Dec\;13,\;2001\~Feb\;21,\;2002,\;4\~23^{\circ}C,\;RH\;36\~89\%)$ after eggshell treatment (unwashed, washed and coated egg) during'10 weeks and examined weight loss and interior quality periodically. Weight loss was in decreasing order room washed > room unwashed > cold washed > cold unwashed > room coated > cold coated egg. And, Haugh unit was decreasing order room washed > room unwashed > room coated > cold washed > cold unwashed > cold coated egg. Our findings show that both coated eggs and refrigeration reduces the rate of decline in Haugh units and egg weight. And, washed eggs had lower average Haugh units and a higher weight loss than any of the eggshell treatment in both storage conditions. Conclusively, for washing eggshell, 150 ppm of sodium hypochlorite, regular exchange and temperature control of water should be consistent and also eggs should be dried immediately after washing. Also, national guidelines for temperature and moisture of storage places, transportation and expiration data should be established to keep quality and weight loss of eggs. Storage temperature that is a critical factor in the quality and safety of eggs should be kept under 12'c and labelling of expiration date should be obligatory.

Estimation of Contamination Level of Listeria monocytogenes in meat and meat products Using Probability Approaches (확률적 접근방법을 이용한 식육에서의 Listeria monocytogenes 오염수준 산출)

  • Park, Gyung-Jin;Kim, Sung-Jo;Shim, Woo-Chang;Chun, Seok-Jo;Choi, Eun-Young;Choi, Weon-Sang;Hong, Chong-Hae
    • Journal of Food Hygiene and Safety
    • /
    • v.18 no.3
    • /
    • pp.107-112
    • /
    • 2003
  • Probabilistic exposure assessment has been recognized as an important tool in microbial risk assessment, because of obtained the desired results to characterize of variability and uncertainty associated with the microbial hazards. In addition, it will be provided much more actuality information than the point-estimate approaches. In this study, we present methodology using mathematical probability distribution in exposure assessment and estimating of contamination level of Listeria monocytogenes in meat and meat products as a case study. The result of estimation contaminatin level was mean ($50^{th}$ percentile) -4.08 Log CFU/g minimum ($5^{th}$ percentile) -4.88 Log CFU/g, maximum ($95^{th}$ percentile) -3.56 Log CFU/g.

Study on the Joint Stiffness, Natural Frequency and Damping Ratio of Stone Pagodas in Korea (국내 석탑의 강성, 고유진동수 및 감쇠비에 관한 연구)

  • Lee, Sung-Min;Choi, Hee-Soo;Lee, Ki-Hak;Lee, Chan-Hee;Jo, Young-Hoon
    • Journal of Korean Association for Spatial Structures
    • /
    • v.18 no.1
    • /
    • pp.45-53
    • /
    • 2018
  • Following the earthquake that shook the city of Gyeongju, Korea, in 2016, it became apparent that research on the safety of cultural heritages against the seismic hazards is necessary in Korea. Predictions of how historically significant stone pagodas would behave the earthquakes anticipated in near future, which are the subject of this study, is also required. In this study, the dynamic characteristics of 15 cultural heritage designated stone pagodas of Korea were investigated, including natural frequency and damping ratio, and the stiffness of the stone material and its contact area were determined using eigenvalue analysis by assuming the stone pagodas to be multi-degree-of-freedom structures. The results of this study enable the structural modeling of stone pagodas using a finite element analysis program and the method is expected to be useful in assessing the structural safety of stone pagodas against vertical loads as well as lateral forces, including earthquakes. Also, by identifying the dynamic characteristics of the structures, the results of this study can be utilized as a nondestructive testing method to determine the rigidity of cultural heritage structures and to identify inherent problems. The natural frequencies of the Korean stone pagodas were measured to be within 3.5~8.3Hz, excluding cases with distinct natural frequency results, and it was determined that the natural frequencies of the stone pagodas are influenced by various parameters including the height and joint stiffness of the structures.

A Study on the Physical and Chemical Characteristics and Hazards Buthanethiol (Buthanethiol의 물리화학적 특성과 유해성 연구)

  • Kim, Hyeon-Yeong
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.4
    • /
    • pp.9-17
    • /
    • 2013
  • Butanethiol is known as a typical odorant with hydrogen sulfide, methyl mercaptan, methyl sulfide, but on the physical and chemical properties and biological hazard assessment, including inhalation toxicity data are very scarce. Butanethiol as a colorless transparent liquid, and has physic-chemical characteristics with flash point as $-23^{\circ}C$ and strong fire risk, boiling point $84-85^{\circ}C$, vapor pressure 80.71 mmHg ($25^{\circ}C$), freezing point $-140.14^{\circ}C$. From whole body exposure with SD rats, the $LC_{50}$ is above 2,500 ppm (9.22mg/L), and then it is classified as the acute toxic chemical (inhalation) category 4 according to the governmental notification No. 2012-14.

Analysis of Induced Voltage on the Gas Pipeline at the Fault in a Underground Power Cables (지중전력케이블에서 고장발생시 인근 가스배관에 유도되는 전압 해석)

  • Bae J. H.;Kim D. K.;Kim K. J.
    • Journal of the Korean Institute of Gas
    • /
    • v.4 no.3 s.11
    • /
    • pp.26-32
    • /
    • 2000
  • Because of the continuous growth of energy consumption, and also the tendency to site power lines and pipelines along the same routes, the close proximity of high voltage structures and metallic pipelines has become more and more frequent. Moreover, normal steady state and fault currents become higher as electric networks increase in size and power Therefore, there has been and still is a growing concern(safety of people marking contact with pipeline, risk of damage to the pipeline coating, the metal and equipment connected to pipeline, especially cathodic protection system) about possible hazards resulting from the influence of high voltage power system on metallic structures(gas pipeline, oil pipeline and water pipeline etc.). Therefore, we analyze the interference problems when the gas pipeline is buried with power cable in the same submarine tunnel. This paper present the results of the study about interference mechanism, AC corrosion limitation of safety voltage and analysis of induction voltage.

  • PDF

Prediction of the Noise Levels for a Newly-founded Petrochemical Plant (신설 석유화학 공장의 소음도 예측)

  • 윤세철;이해경
    • Journal of the Korean Society of Safety
    • /
    • v.11 no.4
    • /
    • pp.135-142
    • /
    • 1996
  • Prolonged in-plant personnel exposure to high noise levels results in permant hearing damage. There are no way to correct this hearing damage by treatment or use of hearing aids. Therefore, every employer is responsible for providing a workplace free of such hazards as excessive noise. This study was carried out to evalute and predict a given noise environment based on specific limit as the noise guarantee for a newly-founded petrochemical plant. The maximum total sound level should not exceed 85dBA in the work area, except where the area is defined as a restricted area and 70dBA at the plant boundary. Prediction of the noise levels within the plant area for a newly-founded petrochemical plant was achieved by dividing all plant area into 20m$\times$20m regular grid spaces and noise level inside the area or unit that in-plant personel exposure to high noise levels was estimated computed into 5m$\times$5m regular grid spaces. The noise level at the grid point that was propagated from each of the noise sources(equipments) computed using the methematical formula was defined as follows : $SPL_2$=$SPL_1-20log{\frac{r_2}{r_1}}$(dB) where $SPL_1$ =sound pressure level at distance $r_1$ from the source $SPL_2$=sound pressure level at distance $r_2$ from the source As a result, the equipments exceeded noise limit or irritaring noise levels were identified on the specific grid coordinates. As for equipments in the area that show high noise levels, appropriate counter-measures for noise control (by barriers, enclosure, silencers, or the change of equipments, for example) should be reviewed. Methods for identifying sources of noise applied in this study should be the model for prediction of the noise levels for any newly-founded plant.

  • PDF