• Title/Summary/Keyword: safety factor and displacement

Search Result 185, Processing Time 0.027 seconds

An EMG Analysis Study of Grinding Work by Posture and Working Time (연삭작업시 작업자세와 작업시간에 따른 근전도 분석에 관한 연구)

  • 배동철;장성록
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.1
    • /
    • pp.79-83
    • /
    • 2001
  • Posture of the upper limbs in field works is known to be an important risk factor associated with CTD(Cumulative Trauma Disorders). In particular, uncomfortable posture and highly repetitive works in shipbuilding industry(for instance, sand blasting, grinding and blast painting, etc) made workers exposed to a great risk of injuries. The purpose of this paper is to analyze recruitment pattern of the muscles according to posture(joint angle displacement) during grinding. In this study, EMG signals of pectoralis major, latissimus dorsi, and posterior deltoid muscle were measured and analyzed from FlexComp EMG solution. And subjective ratings of perceived exertion were made using Borg's CR-10 rating scale.

  • PDF

A case study on the optimal tunnel design based on risk analysis (위험도 분석에 근거한 최적 터널설계 사례)

  • You, Kwang-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.12 no.5
    • /
    • pp.379-387
    • /
    • 2010
  • In this study, a case study was introduced for the design of a twin tunnel along high speed national highway Route 12 from Damyang to Sungsan. It was related to determine the optimal tunnel support pattern and excavation method based on a risk analysis in order to incorporate the uncertainty of ground properties. To this end, three alternatives with different amounts of support and excavation method were selected and risk analysis was performed by applying Monte Carlo simulation technique, respectively. Stability of the tunnel was quantified by the factor of safety. To improve the result, the 729 cases of the combination of ground properties (deformation modulus, cohesion, and internal friction angle) satisfying a Gaussian distribution were generated and applied. Also, stability of the tunnel was confirmed by analyzing the distribution of both displacement and shotcrete bending stress.

The Stability Evaluation for Pseudo-Static Analysis of Composite Dam (복합댐의 등가정적해석에 의한 안정성 평가)

  • 오병현;임정열;이종욱
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.09a
    • /
    • pp.205-212
    • /
    • 2002
  • It was performed that the stability evaluation using pseudo-static method and modified pseudo-static method for rockfill and rockfill-concrete section of composite dam. As a results of pseudo-static and modified pseudo-static analysis using seismic coefficient 0.154g, the maximum displacement at dam crest was occurred about 14~18cm on rockfill section and about 5~9cm on rockfill-concrete section, respectively. Also, that the factor of safety of down slope was more than 1.0~1.5. the rockfill and rockfill-concrete section of composite dam did not show any stability problems for 0.154g. Further research is still necessary in seismic safety of composite dam.

  • PDF

A Proposed method of the Strength Calculation of Pipe Support (파이프 서포트의 내력 산정 방안)

  • 이영욱;최순주
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.1
    • /
    • pp.59-64
    • /
    • 2001
  • Even though there is a guideline for the required strength of pipe support in inspection, it does not mean the nominal strength which can be used for the form work design. And, Concrete Specification defines that the pipe support should be designed according to the steel design guidelines but the design details are not provided, such as buckling length and the sectional modulus, etc. For the better prediction of strength of pipe support, the slenderness ratio of support which reflects the boundary condition should be considered. In this paper, the elastic buckling formula based on the slenderness is derived. The formula contains the strength reduction factor that consider the strength deduction caused by initial lateral deformation and is 0.65 consistently regardless of boundary conditions. And the coefficient of effective buckling length is calculated from the experiment.

  • PDF

Mechanical Fracture Characteristic of Epoxy Insulation Barrier for High Voltage GIS (초고압 GIS용 에폭시 절연물 배리어 파단 특성)

  • Suh, Wang Byuck
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.10
    • /
    • pp.641-645
    • /
    • 2017
  • In this study, an epoxy insulation barrier for high voltage GIS was developed using epoxy and a filler with a Young's modulus of 11 GPa. The material was investigated using a simulation of the principal stress, displacement, and safety factors while optimizing the profile shape. The simulation showed that thelarger Young's modulus of the $Al_2O_3$ filler compared to the $SiO_2$ in the epoxy insulation can contribute to an increase in resistance to mechanical fracturing for theoptimized profile barrier in high voltage GIS. In addition, the safety factor was improved by 10%. It can be concluded that the mechanical fracturing properties of the insulation barrier can be enhanced by increasing the content of the elastic filler, $Al_2O_3$, for high voltage GIS applications.

A Study on Manufacturing Temporary Platform Structure Using Press Forming Processes (프레스 가공 공정을 이용한 가설구조물 제조에 관한 연구)

  • Park, Joon-Hong;Lee, Jae-Sup;Lee, Sung-Keun;Kim, Hyun-Soo;Sung, Ki-ln
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.6 no.4
    • /
    • pp.92-97
    • /
    • 2007
  • A temporary structure is a framework of metal poles and planks, used as a working platform from which building repairs or construction can be carried out safety. The manufacturing process of the existing model consumes a many hour. So, it is modified manufacturing process. In this study, it is attempted to find out the shape of modified working platform considering manufacturing process and using Taguchi method, and it reduces production process. The design parameters are defined to discribe shape of model. As a result of the shape design, maximum Von-Mises stress and displacement considering a safety factor were satisfied with CTEA (Construction Temporary Equipment Association of Korea) standard.

  • PDF

A study on structural integrity and dynamic characteristic of inertial load test equipment for performance test of railway vehicle propulsion control system (철도차량 추진제어장치 성능시험을 위한 관성부하 시험설비의 구조안전성 및 동특성 평가 연구)

  • Jang, Hyung-Jin;Shin, Kwang-Bok;Lee, Sang-Hoon;Lee, Dae-Bong
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.1389-1394
    • /
    • 2010
  • This paper describes the evaluation of structural integrity and dynamic characteristic of inertial load test equipments for performance test of railway vehicle propulsion control system. The propulsion control system of railway vehicle has to be confirmed of safety and reliability prior to it's application. Therefore, inertial load test equipments were designed through theoretical equation for performance test of propulsion control system. The structural analysis of inertial load test equipments was conducted using Ansys v11.0 and it's dynamic characteristic was evaluated the designed using Adams. The results showed that the structural integrity of inertial load test equipment was satisfied with a safety factor of 10.2. Also, the structural stability was proved by maximum dynamic displacement of 0.82mm.

  • PDF

Development of Seismic Damage Evaluation factor of Reinforced Concrete Pier for Fragility Analysis (취약도 해석을 위한 철근콘크리트 교각의 지진손상 평가인자 결정)

  • 고현무;이지호;강중원;조호현
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2002.09a
    • /
    • pp.308-315
    • /
    • 2002
  • Fragility analysis is widely used for the seismic safety evaluation of a structure. In fragility analysis, damage evaluation is a crucial factor. Most of the present fragility analyses use the representative responses such as displacement and absorbed hysteretic energy as a tool of damage evaluation. But damage evaluation method that can represent the local damage of a structure is required in the case of piers of which the local damage can cause the whole failure of bridge system. Therefore this study proposes a damage index, which can represent the distribution and magnitude of local damage by using the Lee and Fenves'plastic-damage model. Using the proposed damage index, fragility curves and damage probability matrix of pier are produced and fragility analysis is performed.

  • PDF

Structural Safety Analysis on Crack Propagation in Compact Tension Specimen (소형 인장 시험편 내의 크랙 전파에 대한 구조 안전해석)

  • Cho, Jae-Ung
    • Journal of the Korea Convergence Society
    • /
    • v.5 no.1
    • /
    • pp.23-27
    • /
    • 2014
  • In case eccentric load is applied at compact tension specimen, the propagation behavior due to existence or nonexistence of hole, numbers and positions of holes near crack is investigated in this study. Strain energy, displacement and stress happened in specimen are examined through simulation analysis. And stress intensity factor is obtained by the basis of strain energy and deformation. When defect or hole exists in structure, the possibility of fracture can be thought to be verified by using the study result.

The Influence of Impact Angle on Hip Fracture in Fallings

  • Choi, Jae-Bong
    • International Journal of Safety
    • /
    • v.4 no.1
    • /
    • pp.1-7
    • /
    • 2005
  • The direction of the applied load and displacement rate on the femur during falls may be an important factors in the etiology of hip fractures. Nonetheless, previous studies did not consider these two factors simultaneously for falling condition. Therefore, in the present study, an impact test system is developed to simulate the falling condition and the influence of impact angle on the deformation pattern changes of proximal femur is investigated. The results showed that a slight variation in impact angle quite affects deformation pattern of the proximal femur. Along with bone mineral density and trabaecular morphology, the impact angle can be another important factor affecting the structural capacity of the proximal femur.