Development of IoT-based Safety Management Method through an Analysis of Risk Factors for Industrial Valves (산업용 밸브의 위험요소 분석을 통한 IoT 기반 안전관리 방안 개발)

  • Kim, Jung-Hoon;Kim, Young-Gu
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.5
    • /
    • pp.35-43
    • /
    • 2019
  • The safety of industrial valves, which are the core parts of plant facilities, are managed by manpower and there are difficulties because of side area for inspection and limited accessibility due to the nature of facilities. The industrial valves used in plant facilities cause problems such as interrupted production; a loss of life due to leak or explosion of poisonous material and flammable gases, and difficulty in locating accident positions in the event of leakage or failure. Therefore, safety management and control systems based on IoT technology are needed. This study is about the development of risk factor prediction technique among the safety management of industrial valves through IoT- based wireless communication and the development of actuator control system. We have developed IoT-based industrial valve safety management techniques to prevent accidents caused by main risk factors by conducting an analysis of the structural characteristics of valves and an analysis of the causes of main risk factors through review of failure data and literature and an analysis of accident scenarios.

Workers' perceptions on the experience education for occupational safety and health in community: Focused on the values and affecting factors (지역사회 산업안전보건 체험교육에 대한 근로자의 인식: 체험교육의 가치와 영향 요인을 중심으로)

  • Park, Kyoung Ok
    • The Journal of Korean Society for School & Community Health Education
    • /
    • v.22 no.1
    • /
    • pp.73-92
    • /
    • 2021
  • Objectives: The purposes of this study was to describe workers' perceived values and the affecting factors (pros and cons) of the experience education for occupational safety and health and to suggest the strategies and future directions to improve the experience educational quality. Methods: A total of 8 male workers taking the safety and health education of the 7 safety experience education centers involved in this study (5 centers managed by Korea Occupational Safety and Health Agency (KOSHA), 2 centers of large commercial companies). This study used Photovoice, a qualitative method, as the study method. We conducted the photovoice-based in-depth interview with the SHOWeD questions and strategy and used the taxonomical analysis. Results: The study participants' perceived values of experience education were strengthening self-efficacy of the safety and health practices, providing practically useful information, and enjoying refreshing experiences different from daily jobs. Positive affecting factors of the experience education (pros) were providing the educational environments and opportunities of direct experiences, teaching practical safety and health contents for the participants, and the trainer's instruction competencies. Negative affecting factors of the experience education (cons) were learner's negative or standing postures during trainer's lecturing, insufficient exercise conditions and facilities for education, and difficult and theory-oriented lecture far from the practical jobs in reality. Conclusions: Major values of exercise education were direct experiences, useful contents and interesting opportunities from the education participants' perspectives. To improve the exercise education quality, overall educational environments such as convenience facilities as well as exercise facilities should be modified altogether. This study partially and conveniently used the photovoice method as the study limitation.

A Study on the Safety Job Procedures for Alkaline Water Electrolysis Facilities Based on Renewable Energy (재생에너지 기반 알칼라인 수전해설비의 안전작업절차 방안 연구)

  • Doo-Hyoun Seo;Tae-Hun Kim;Kwang-Won Rhie;Seong-Chul Hong;Hyun-Gi Kim
    • Journal of the Korean Institute of Gas
    • /
    • v.28 no.1
    • /
    • pp.27-34
    • /
    • 2024
  • In accordance with the clean hydrogen-centered hydrogen industry development plan, technology development and demonstration operation of water electrolysis devices are being actively carried out. Risk assessments are performed on newly developed hydrogen-using facilities and supplies to identify potential hazard factors. However, in general, most industrial accidents are caused by operator's human error or incorrect work practices. Additionally, the possibility of accidents occurring during operation control, maintenance, and inspection increases. For this reason, for equipment developed for demonstration operation, the correct work methods for the main jobs of operator must be reviewed and work procedures must be prepared. Accordingly, in this study, we conducted a job safety analysis (JSA) on major jobs in the operation of water electrolysis facilities to study safe work methods and necessary measures.

A Study on the DC Leakage Current Test for Power Cable of Private Electrical Facilities considering Lightning Arrester (피뢰기를 고려한 자가용 전기설비 인입선로의 직류누설전류시험에 관한 연구)

  • Jeong, Ki-Seok;Gil, Hyoung-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.1
    • /
    • pp.142-147
    • /
    • 2018
  • Private electrical facilities are judged whether it is suitable for the insulation aging condition of their incoming underground cables using DC leakage current test method. In the case where the service point of utility is the secondary side of cut out switch installed in the electric pole, there is a problem that it is difficult to separate the lightning arresters(LA) because of their high position of the pole. Therefore, the field test voltage is applied at value lower than DC 30 kV, which are stated in the inspection guideline. However, this test could reduced the insulation performance of the LA by accelerating the electrical stress of the metal oxide varistor element in the pre-breakdown region. In this study, we analyzed the relationship between the DC test voltage and the leakage current using the non-destructive DC high voltage equipment with leakage current measurement function. The results show that the leakage current increases sharply above the specified test voltage. As a consequence, it could be contributed to improve insulation aging inspection method by selecting the possible test area on the VI characteristic curve of the pre-breakdown area of the LA.

A Study on the Improvement of Dangerous Goods Safety Management in Maritime Terminal (항만 옥외저장소 위험물의 안전관리 개선 방안)

  • Lee, Bong-Woo;Shin, Se-Cheol;Park, Kyung-Jin;Choina, Yeong-Hwan
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.3
    • /
    • pp.393-401
    • /
    • 2020
  • According to the research and investigations performed on Port Facilities for cargo-works of hazardous materials around the Port of Busan, a conclusion was drawn that the manually operating foam tower monitors are ineffective as they are hard to access due to the radiant heat under contingency circumstances such as a fire. Moreover, in some cases, the effective range of Foam Tower Monitors are insufficient to reach docked ships and manifolds where hazardous materials are being unloaded. In addition, Dangerous Goods freights are inadequately and inefficiently stored regardless properties of hazardous substances due to complicated local regulations, and some are equipped with inapplicable facilities for docked ships. Therefore, in order to effectively counteract the contingencies and obtain safety, it would be recommended to install adequate facilities.

The guideline for development and verification of railway software (철도 소프트웨어 개발 및 검증을 위한 지침)

  • Lee, Young-Jun;Choi, Jong-Gyun;Cha, Kyung-Ho;Cheon, Se-Woo;Lee, Jang-Soo;Kwon, Ki-Choon;Jung, Ui-Jin
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.659-664
    • /
    • 2008
  • The Railroad Safety Act's regulation reads as follows. "The Minister of Construction and Transportation may qualify and authorize the product to guarantee performance and safety of parts, machine, and device used in Railway fields." Another regulation reads as follows."“The guidelines about targets, standards, and procedures of Quality and Authority in first provision are decided as Ministry of Construction and Transportation Decree." The software used in rail cars and facilities is considered as a railway product. Therefore, it is qualified and authorized for acquiring the safety of rail cars and facilities. The software businesses shall again a Quality and Authority for applying a software to the rail cars and facilities. This paper regulates some guidelines that are needed to develop a software. The procedures that a software developer performs are divided by plan, requirement, design, implementation, and maintenance. The procedures that a software verification person performs are classified by verification plan, requirement verification, design verification, implementation verification, testing verification, maintenance verification, and safety activity. The entire processes and detailed activities to develope and verify a software are described as new guidelines.

  • PDF

A Study on the Safety for Pedestrians Waiting for Signal (보행신호를 대기하는 보행자의 안전에 관한 연구)

  • Kim, Hansol;Baek, Seryong;Choi, Yongsoon;Yoon, Junkyu;Lim, Jonghan
    • Journal of Auto-vehicle Safety Association
    • /
    • v.13 no.3
    • /
    • pp.41-46
    • /
    • 2021
  • The number of big traffic accident cases of pedestrian death appeared to be minor, however compared to death rate in car to car accidents is very high and quite a few of the pedestrian death rates among all traffic accidents are counted to be almost 40%. Previous pedestrian safety studies were mostly aimed at reducing the degree of pedestrian injuries from a vehicle to pedestrian collision, and less at preventing a collision itself. This research was conducted with a method of using road facilities to prevent vehicles from rushing into the sidewalk. This research used one of the collision analyzing programs, called PC-Crash to simulate the vehicle rushing into the sidewalk. Based on the program, it could derive an optimal safe zone location where the pedestrian can wait for the pedestrian light safely. Also, changing road facilities such as pedestrian light pillars or signal controllers can widen 440% compared to the present safe zone. Accordingly, researchers have to consider a method to analyze and apply pedestrian safe zones along with road facilities location when designing a road.

A Study on current Status and the problem of Agricultural Facilities (농촌시설물에 대한 현황 및 문제점 파악에 관한 연구)

  • Choi, Oh-Young;Shin, Han-Woo;Kim, Tae-Hui;Kim, Gwang-Hee
    • Journal of the Korea Institute of Building Construction
    • /
    • v.8 no.6
    • /
    • pp.147-154
    • /
    • 2008
  • In today, there has been an increase in the construction of agricultural facilities due to the development in agricultural technology. Agricultural facilities are becoming bigger and higher to plant various agriculture. This study analyzes the construction and maintenance problems in agricultural facilities. The results of this survey on the status of agricultural facilities are presented. Firstly, the construction cost is most important factor in agricultural facilities. Secondly, Materials durability is important factor in selecting the facilities. Third, safety in facilities is also important factor. The results of this research are greenhouse is lack of the law of contract and the performance and need for the construction process supervision.

A Study on the School Safety Accidents Prevention Policy Applied Delphi Technique (델파이 기법을 활용한 학교안전사고 예방정책에 관한 연구)

  • Park, Sang-Keun;Yoon, Yong Gi
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.14 no.2
    • /
    • pp.45-63
    • /
    • 2015
  • The purpose of this study is to suggest school safety accidents prevention policy by applying delphi technique as a method to decrease school safety accidents which have been increasing consistently. As results of Delphi, the plans to improve school safety accidents prevention policy per area are as follows: First, it is required to establish systematic safety policy by dividing school facilities into four stages such as planning, designing and building, maintenance and evaluation etc. Second, it is required studies to overcome budget limitation and accountability of people in charge of safety of facilities to apply school safety policy as a useful measure. Third, it is required to make an effort to revise relevant legislations through examinations of relevant government ministries per each area to reflect prevention measures to safety policy consistently.

Factors affecting radiation safety management practice of radiation workers in dental medical institutions (치과의료기관 방사선관계종사자의 방사선 안전관리 실천도에 영향을 미치는 요인)

  • Lee, Eun-Gyeong;Jang, Gye-Won;Kweon, Dae-Cheol;Lee, Kyeong-Hee
    • Journal of Korean society of Dental Hygiene
    • /
    • v.19 no.2
    • /
    • pp.251-263
    • /
    • 2019
  • Objectives: To establish foundations for reinforcing radiation safety management in dental facilities. Methods: This study investigated the status of radiation safety management among radiation workers in dental facilities nationwide for a period of six months from July to December in 2018 and analyzed the factors that affect their compliance with radiation safety measures. Results: Compliance with safety measures was higher in the Honam region (p<0.01) and Yeongnam region (p<0.01), in university hospitals and general hospitals (p<0.05), along with an increasing perception of the importance of safety management (p<0.001). Conclusions: It is important to strengthen education about radiation safety management, develop a radiation safety guideline that could be reasonably applied to dental institutions, and implement relevant regulations or legal grounds to promote compliance with these measures.