• Title/Summary/Keyword: safety facilities

Search Result 3,112, Processing Time 0.033 seconds

Microbiological Hazard Analysis and Verification of Critical Control Point (CCP) in a Fresh-Cut Produce Processing Plant -Case Study of a Fresh-Cut Leaf Processing Plant- (신선편이 농산물 가공업체의 미생물학적 위해 요소 분석 및 중점 관리 지점(CCP)의 검증 -신선편이 엽채류 가공업체를 대상으로-)

  • Kim, Su-Jin;Sun, Shih-Hui;Min, Kyung-Jin;Yoon, Ki-Sun
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.21 no.3
    • /
    • pp.392-400
    • /
    • 2011
  • The objectives of this study were to analyze environmental microbial contamination levels by sampling the surfaces of processing lines and equipment and to verify CCPs of the HACCP plan in a fresh-cut produce processing plant The level of airborne microorganisms in the processing plant was $10^1$ log CFU/plate/15min. Total plate counts and coliform groups of the processing facilities were 1~2 log CFU/100 $cm^2$. No E. coli or S. aureus were detected in the processing plant. However, total plate counts on the cutting board for raw materials and on the spin-dryer were $4.20{\pm}2.12$ log CFU/$cm^2$ and $4.57{\pm}0.92$ log CFU/$cm^2$, respectively. These levels were higher than the safe microbial level, and therefore, the chance of cross-contamination during processing was increased. According to the results of microbiological analyses, total aerobic bacteria and coliform groups of the samples were increased after the second washing and spin-drying steps, due to cross-contamination from the spin-dryer. Thus, an effective method that can be used for microbial control during the washing and drying steps is needed for microbial control in fresh-cut produce processing plants. The results of a verification study also suggest that modification of the HACCP plan is needed along with additional CPs, which were identified as a second washing, spin drying, and the cold storage of final products.

Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014 (설비공학 분야의 최근 연구 동향: 2014년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.7
    • /
    • pp.380-394
    • /
    • 2015
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2014. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of heat and mass transfer, cooling and heating, and air-conditioning, the flow inside building rooms, and smoke control on fire. Research issues dealing with duct and pipe were reduced, but flows inside building rooms, and smoke controls were newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for thermal contact resistance measurement of metal interface, a fan coil with an oval-type heat exchanger, fouling characteristics of plate heat exchangers, effect of rib pitch in a two wall divergent channel, semi-empirical analysis in vertical mesoscale tubes, an integrated drying machine, microscale surface wrinkles, brazed plate heat exchangers, numerical analysis in printed circuit heat exchanger. In the area of pool boiling and condensing, non-uniform air flow, PCM applied thermal storage wall system, a new wavy cylindrical shape capsule, and HFC32/HFC152a mixtures on enhanced tubes, were actively studied. In the area of industrial heat exchangers, researches on solar water storage tank, effective design on the inserting part of refrigerator door gasket, impact of different boundary conditions in generating g-function, various construction of SCW type ground heat exchanger and a heat pump for closed cooling water heat recovery were performed. (3) In the field of refrigeration, various studies were carried out in the categories of refrigeration cycle, alternative refrigeration and modelling and controls including energy recoveries from industrial boilers and vehicles, improvement of dehumidification systems, novel defrost systems, fault diagnosis and optimum controls for heat pump systems. It is particularly notable that a substantial number of studies were dedicated for the development of air-conditioning and power recovery systems for electric vehicles in this year. (4) In building mechanical system research fields, seventeen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the evaluation of work noise in tunnel construction and the simulation and development of a light-shelf system. The subjects of building energy were worked on the energy saving of office building applied with window blind and phase change material(PCM), a method of existing building energy simulation using energy audit data, the estimation of thermal consumption unit of apartment building and its case studies, dynamic window performance, a writing method of energy consumption report and energy estimation of apartment building using district heating system. The remained studies were related to the improvement of architectural engineering education system for plant engineering industry, estimating cooling and heating degree days for variable base temperature, a prediction method of underground temperature, the comfort control algorithm of car air conditioner, the smoke control performance evaluation of high-rise building, evaluation of thermal energy systems of bio safety laboratory and a development of measuring device of solar heat gain coefficient of fenestration system.

Relation of Social Security Network, Community Unity and Local Government Trust (지역사회 사회안전망구축과 지역사회결속 및 지방자치단체 신뢰의 관계)

  • Kim, Yeong-Nam;Kim, Chan-Sun
    • Korean Security Journal
    • /
    • no.42
    • /
    • pp.7-36
    • /
    • 2015
  • This study aims at analyzing difference of social Security network, Community unity and local government trust according to socio-demographical features, exploring the relation of social Security network, Community unity and local government trust according to socio-demographical features, presenting results between each variable as a model and verifying the property of mutual ones. This study sampled general citizens in Gwangju for about 15 days Aug. 15 through Aug. 30, 2014, distributed total 450 copies using cluster random sampling, gathered 438 persons, 412 persons of whom were used for analysis. This study verified the validity and credibility of the questionnaire through an experts' meeting, preliminary test, factor analysis and credibility analysis. The credibility of questionnaire was ${\alpha}=.809{\sim}{\alpha}=.890$. The inout data were analyzed by study purpose using SPSSWIN 18.0, as statistical techniques, factor analysis, credibility analysis, correlation analysis, independent sample t verification, ANOVA, multi-regression analysis, path analysis etc. were used. the findings obtained through the above study methods are as follows. First, building a social Security network has an effect on Community institution. That is, the more activated a, the higher awareness on institution. the more activated street CCTV facilities, anti-crime design, local government Security education, the higher the stability. Second, building a social Security network has an effect on trust of local government. That is, the activated local autonomous anti-crime activity, anti-crime design. local government's Security education, police public oder service, the more increased trust of policy, service management, busines performance. Third, Community unity has an effect on trust of local government. That is, the better Community institution is achieved, the higher trust of policy. Also the stabler Community institution, the higher trust of business performance. Fourth, building a social Security network has a direct or indirect effect on Community unity and local government trust. That is, social Security network has a direct effect on trust of local government, but it has a higher effect through Community unity of parameter. Such results showed that Community unity in Gwangju Region is an important factor, which means it is an important variable mediating building a social Security network and trust of local government. To win trust of local residents, we need to prepare for various cultural events and active communication space and build a social Security network for uniting them.

  • PDF

Risk Ranking Analysis for the City-Gas Pipelines in the Underground Laying Facilities (지하매설물 중 도시가스 지하배관에 대한 위험성 서열화 분석)

  • Ko, Jae-Sun;Kim, Hyo
    • Fire Science and Engineering
    • /
    • v.18 no.1
    • /
    • pp.54-66
    • /
    • 2004
  • In this article, we are to suggest the hazard-assessing method for the underground pipelines, and find out the pipeline-maintenance schemes of high efficiency in cost. Three kinds of methods are applied in order to refer to the approaching methods of listing the hazards for the underground pipelines: the first is RBI(Risk Based Inspection), which firstly assess the effect of the neighboring population, the dimension, thickness of pipe, and working time. It enables us to estimate quantitatively the risk exposure. The second is the scoring system which is based on the environmental factors of the buried pipelines. Last we quantify the frequency of the releases using the present THOMAS' theory. In this work, as a result of assessing the hazard of it using SPC scheme, the hazard score related to how the gas pipelines erodes indicate the numbers from 30 to 70, which means that the assessing criteria define well the relative hazards of actual pipelines. Therefore. even if one pipeline region is relatively low score, it can have the high frequency of leakage due to its longer length. The acceptable limit of the release frequency of pipeline shows 2.50E-2 to 1.00E-l/yr, from which we must take the appropriate actions to have the consequence to be less than the acceptable region. The prediction of total frequency using regression analysis shows the limit operating time of pipeline is the range of 11 to 13 years, which is well consistent with that of the actual pipeline. Concludingly, the hazard-listing scheme suggested in this research will be very effectively applied to maintaining the underground pipelines.

A Study on the Application of Bushings Fire Prevent Structure to Prevent Fire Spread of Transformer (변압기의 화재확산 방지를 위한 부싱 방화구조체 적용에 관한 연구)

  • Kim, Do-Hyun;Cho, Nam-Wook;Yoon, Choung-Ho;Park, Pil-Yong;Park, Keun-Sung
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.53-62
    • /
    • 2017
  • Electric power which is the energy source of economy and industries requires long distance transportation due to regional difference between its production and consumption, and it is supplied through the multi-loop transmission and distribution system. Prior to its actual use, electric power flows through several transformations by voltage transformers in substations depending on the characteristics of each usage, and a transformer has the structure consisting of the main body, winding wire, insulating oil and bushings. A transformer fire that breaks out in substations entails the primary damage that interrupts the power supply to houses and commercial facilities and causes various safety accidents as well as the secondary economic losses. It is considered that causes of such fire include the leak of insulating oil resulting from the destruction of bottom part of bushings, and the chain reaction of fire due to insulating oil that reaches its ignition point within 1 second. The smoke detector and automatic fire extinguishing system are established in order to minimize fire damage, but a difficulty in securing golden time for extinguishing fire due to delay in the operation of detector and release of gas from the extinguishing system has become a problem. Accordingly, this study was carried out according to needs of active mechanism to prevent the spread of fire and block the leak of insulating oil, in accordance with the importance of securing golden time in extinguishing a fire in its early stage. A bushings fireproof structure was developed by applying the high temperature shape retention materials, which are expanded by flame, and mechanical flame cutoff devices. The bushings fireproof structure was installed on the transformer model produced by applying the actual standards of bushings and flange, and the full scale fire test was carried out. It was confirmed that the bushings fireproof structure operated at accurate position and height within 3 seconds from the flame initiation. It is considered that it could block the spread of flame effectively in the event of actual transformer fire.

Analysis of Current Status and Utilization of Protected Trees in Gyeongsan City (경산시 보호수의 현황분석 및 활용방안)

  • Kim, Keun-Ho
    • Journal of agriculture & life science
    • /
    • v.45 no.2
    • /
    • pp.69-83
    • /
    • 2011
  • The aim of the research was to provide basic information for a suitable management and utilization of protected trees by law. To achieve this aim, this study investigated the current state, management status and utilization of protected trees by law in Gyeongsan city. The result of the current state of protected trees indicated that there were 55 protected trees designated since 1982. These trees consisted of 8 species which were located at 41 places. Major species was Sophora japonica (30.9%), followed by Zelkova serrata (23.6%). The protected trees have been used as sacred trees (45.5%) in the villages, followed by scenic trees (36.7%). 38.2% of the protected trees were 200 to 300 years old and 54.6% of the trees were 15 to 30 m in height. 34% of the protected trees were located in the villages, followed by beside road (19.5%). Single trees (78%) were mostly planted. The result of the management status indicated that 58.5% of the root area in protected trees were covered with bare ground, followed by gravel mulch (19.5%). The average of soil hardness was 9.64 mm. The safety fence of tree was installed at 9 places (22%) and a stone wall was built at 22 places (53.7%). 70.9% of the protected trees had a surgical operation to prevent cavities and to cure decay. Granite stone signs were installed at 33 places. The result of the utilization of protected trees indicated that 13 places were used as a rest area in the villages. It consisted of shelters, benches, athletic facilities and outdoor tables. The research suggested potential places for a mini park(pocket park) to recover a local community by using surrounding available land and improving current rest areas of protected trees. The research presented here is a first step towards a more comprehensive analysis of protected trees in Gyeongsan and further research is needed.

Estimation of sediment deposition rate in collapsed reservoirs(wetlands) using empirical formulas and multiple regression models (경험공식 및 다중회귀모형을 이용한 붕괴 저수지(습지) 비퇴사량 추정)

  • Kim, Donghyun;Lee, Haneul;Bae, Younghye;Joo, Hongjun;Kim, Deokhwan;Kim, Hung Soo
    • Journal of Wetlands Research
    • /
    • v.23 no.4
    • /
    • pp.287-295
    • /
    • 2021
  • As facilities such as dam reservoir wetlands and agricultural irrigation reservoir wetlands are built, sedimentation occurs over time through erosion, sedimentation transport, and sediment deposition. Sedimentation issues are very important for the maintenance of reservoir wetlands because long-term sedimentation of sediments affects flood and drought control functions. However, research on resignation has been estimated mainly by empirical formulas due to the lack of available data. The purpose of this study was to calculate and compare the sediment deposition rate by developing a multiple regression model along with actual data and empirical formulas. In addition, it was attempted to identify potential causes of collapse by applying it to 64 reservoir wetlands that suffered flood damage due to the long rainy season in 2020 due to reservoir wetland sedimentation and aging. For the target reservoir, 10 locations including the GaGog reservoir located in Miryang city, Gyeongsangnam province in South Korea, where there is actual survey information, were selected. A multiple regression model was developed in consideration of physical and climatic characteristics, and a total of four empirical formulas and sediment deposition rate were calculated. Using this, the error of the sediment deposition rate was compared. As a result of calculating the sediment deposition rate using the multiple regression model, the error was the lowest from 0.21(m3km2/yr) to 2.13(m3km2/yr). Therefore, based on the sediment deposition rate estimated by the multi-regression model, the change in the available capacity of reservoir wetlands was analyzed, and the effective storage capacity was found to have decreased from 0.21(%) to 16.56(%). In addition, the sediment deposition rate of the reservoir where the overflow damage occurred was relatively higher than that of the reservoir where the piping damage occurred. In other words, accumulating sediment deposition rate at the bottom of the reservoir would result in a lack of acceptable effective water capacity and reduced reservoir flood and drought control capabilities, resulting in reservoir collapse damage.

Correlation Analysis between Damage of Expansion Joints and Response of Deck in RC Slab Bridges (RC 슬래브교의 신축이음 손상과 바닥판 응답과의 상관관계 분석)

  • Jung, Hyun-Jin;An, Hyo-Joon;Park, Ki-Tae;Jung, Kyu-San;Kim, Yu-Hee;Lee, Jong-Han
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.6
    • /
    • pp.245-253
    • /
    • 2021
  • RC slab bridges account for the largest portion of deteriorated bridges in Korea. However, most RC slabs are not included in the first and second classes of bridges, which are subject to bridge safety management and maintenance. The highest damaged components in highway bridges are the subsidiary facilities including expansion joints and bearings. In particular, leakage through expansion joints causes deterioration and cracks of concrete and exposure of reinforced bars. Therefore, this study analyzed the effect of adhesion damage at expansion joints on the response of the deck in RC slab bridges. When the spacing between the expansion joints at both ends was closely adhered, cracks occurred in the concrete at both ends of the deck due to the resistance rigidity at the expansion joints. Based on the response results, the correlation analysis between displacements in the longitudinal direction of the expansion joint and concrete stress at both ends of the deck for each damage scenario was performed to investigate the effect of the occurrence of damage on the bridge behavior. When expansion joint devices at both sides were damaged, the correlation between displacement and stress showed a low correlation of 0.18 when the vehicles proceeded along all the lanes. Compared with those in the intact state, the deflections of the deck in the damaged case at both sides showed a low correlation of 0.34 to 0.53 while the vehicle passed and 0.17 to 0.43 after the vehicle passed. This means that the occurrence of cracks in the ends of concrete changed the behavior of the deck. Therefore, data-deriven damage detection could be developed to manage the damage to expansion joints that cause damage and deterioration of the deck.

A comparative study of risk according to smoke control flow rate and methods in case of train fire at subway platform (지하철 승강장에서 열차 화재 시 제연풍량 및 방식에 따른 위험도 비교 연구)

  • Ryu, Ji-Oh;Lee, Hu-Yeong
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.24 no.4
    • /
    • pp.327-339
    • /
    • 2022
  • The purpose of this study is to present the effective smoke control flow rate and mode for securing safety through quantitative risk assessment according to the smoke control flow rate and mode (supply or exhaust) of the platform when a train fire occurs at the subway platform. To this end, a fire outbreak scenario was created using a side platform with a central staircase as a model and fire analysis was performed for each scenario to compare and analyze fire propagation characteristics and ASET, evacuation analysis was performed to predict the number of deaths. In addition, a fire accident rate (F)/number of deaths (N) diagram (F/N diagram) was prepared for each scenario to compare and evaluate the risk according to the smoke control flow rate and mode. In the ASET analysis of harmful factors, carbon monoxide, temperature, and visible distance determined by performance-oriented design methods and standards for firefighting facilities, the effect of visible distance is the largest, In the case where the delay in entering the platform of the fire train was not taken into account, the ASET was analyzed to be about 800 seconds when the air flow rate was 4 × 833 m3/min. The estimated number of deaths varies greatly depending on the location of the vehicle of fire train, In the case of a fire occurring in a vehicle adjacent to the stairs, it is shown that the increase is up to three times that of the vehicle in the lead. In addition, when the smoke control flow rate increases, the number of fatalities decreases, and the reduction rate of the air supply method rather than the exhaust method increases. When the supply flow rate is 4 × 833 m3/min, the expected number of deaths is reduced to 13% compared to the case where ventilation is not performed. As a result of the risk assessment, it is found that the current social risk assessment criteria are satisfied when smoke control is performed, and the number of deaths is the flow rate 4 × 833 m3/min when smoke control is performed at 29.9 people in 10,000 year, It was analyzed that it decreased to 4.36 people.

A Study on the Countermeasures Taken By the Korean Healthcare and Life Sciences Industry Regarding U.S. Import Refusals: Focus on the Analysis of FDA Violation Codes (한국 바이오헬스 산업의 미국 수입거부 대응 방안 연구 : FDA 위반코드 분석을 중심으로)

  • Yu-Han Lee;Hag-Min Kim
    • Korea Trade Review
    • /
    • v.48 no.3
    • /
    • pp.131-150
    • /
    • 2023
  • The purpose of this study was to find a countermeasure to the U.S. import refusals for the Korean healthcare and life sciences industry. To this end, an analysis of trends during the pandemic was conducted using the KITA Border Rejection Database, which includes information on items and types of import refusals. The reason for rejection was also analyzed according to the FDA violation codes. The degree of countermeasure for import refusals was identified by measuring the unit rejection rate (URR). The results of the analysis showed that the major U.S. import refusals for the Korean healthcare and life sciences industry had expanded from contact lenses to COVID-19 diagnostic kits and drugs after the pandemic broke out. The major reasons for import refusals were non-compliance with the Predicate Device and Drugs Act and non-approval by the FDA for products and facilities. On the other hand, the unit rejection rate (URR) of major items in the Korean healthcare and life sciences industry was measured higher than the industry average. The results therefore showed a low level of response to U.S. import refusals. The results of the analysis of reasons for import refusals by item according to FDA violation codes were as follows. First of all, the main violation for contact lenses and COVID-19 diagnostic kits corresponded to misbranding. This was often due to the fact that Korean companies did not provide the relevant notices and information required by the FDA. Many cases also failed to demonstrate a substantial equivalency compared to predicate devices already on the market. On the other hand, applications for new unapproved drugs were not accepted as they had yet to pass relevant regulations that would prove their safety and efficacy. In conclusion, import refusals for the Korean healthcare and life sciences industry were found to be closely related to technical barriers to trade (TBT).