A Study on the Calculation of Evacuation Capacity for the Development of Korean Life Safety Standards for Medical facilities (의료시설의 한국형 인명안전기준개발을 위한 피난용량 산정에 관한 연구)

  • Choi, Yun-Ju;Kim, Yun-Seong;Jin, Seung-Hyeon;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.92-93
    • /
    • 2021
  • In the case of medical facilities, the evacuation time is delayed due to the decrease in the number of people in the hallway and exits due to the increase in the width of evacuation by using mobile beds, wheelchairs, crutches, etc. Accordingly, it is considered to secure evacuation capacity to reduce evacuation time according to corridor width and exit width. Accordingly, we would like to compare the standards related to the evacuation capacity of medical facilities in Korea and NFPA, derive differences, and use evacuation simulations to compare evacuation times according to changes in corridor width and exit width. In Korea, it is calculated based on the floor area by use, but in the case of NFPA 101, the number of evacuation routes, stair width, corridor exit width, and two-way door width was stipulated depending on the number of people. Using evacuation simulation, efficient evacuation capacity is calculated according to the reduction of evacuation time by changing the width of the hallway, changing the width of the exit, the width of the corridor, and the width of the exit. The evacuation simulation is intended to be used to secure evacuation safety of domestic medical facilities by calculating the effective evacuation time reduction by changing the width of the hallway and exit.

  • PDF

Development of Real-Time Active Type Seals (실시간 능동형 타입 격납장치 개발)

  • Jung-ki Shin;Heekyun Baek;Yongju Lee
    • Journal of Radiation Industry
    • /
    • v.18 no.1
    • /
    • pp.9-14
    • /
    • 2024
  • In order to thoroughly verify the denuclearization of the Korean Peninsula, it is urgent to develop technology capabilities to monitor, detect, collect, analyze, interpret, and evaluate nuclear activities using nuclear materials and secure nuclear transparency. The IAEA is actively using seal technology to maximize the efficiency of safety measures, and currently uses metal cap, paper, COBRA, and EOSS as seal devices. Unlike facilities that comply with safety measures requirements, such as domestic nuclear facilities, facilities subject to denuclearization are likely to have various risk environments that make it difficult to apply safety measures, and there is a high possibility that continuity of knowledge (COK) such as damage, malfunction, and power loss will not be maintained. This study aims to develop a real-time active seal device that can be applied in such special situations to enable immediate response in the event of a similar situation. To this end, the main functions of the real-time seal device were derived and applied, and a commercialized seal device and operation software. The real-time seal technology developed through this study can be applied to all nuclear facilities in South Korea, especially used as storage equipment for dry cask storage facilities of heavy water reactor's after fuel, and it is believed that unnecessary radiation exposure by inspectors can be minimized.

Simple priority setting method for Screening in public health assessment of waste incineration facilities (폐기물 소각시설 주변 환경보건평가 중 스크리닝 단계에서의 우선순위 선정기법에 관한 연구)

  • Kim, Gi Young;Hong, Seung Cheol
    • Journal of Environmental Impact Assessment
    • /
    • v.21 no.5
    • /
    • pp.813-821
    • /
    • 2012
  • Environmental and public health concern for the emission of air pollutants from burn-up process in waste incineration plants located in the vicinity of living environment was increased during the past decade. The purpose of this study was to suggest of the simple and rapid method of priority setting model for the decision of full-scale public health assessment. This method was consists of total 5-step. Step 1 was "secure the satellite map" and we can use the satellite map which serves from the website such as NAVER Co. Step 2 was "drawing mesh on the map" for catch the point of occupation of environmental sensitivity facilities, and step 3 was "identification and sorting of the facilities", Step 4 was "setting of weight" using the "weighted linear combination (WLC) method". Finally, all facility was sorted by score. As a result, we can set a priority of 145 facilities based on 177 facilities which managed in local government. Facilities in Seoul metropolitan area was high rank in priority list. On the other side, Facilities located at the country or rural area was low rank because of low occupation of the house and the environmental sensitivity facilities such as kindergarten, elementary school, and hospital. In this study, we suggested simple and rapid method that using for screening procedure of public health assessment.

Human Hazard by Outdoor Electrical Facilities in Submerged Area (옥외 전기시설물 침수시 누설전류에 의한 인체영향)

  • 하태현;이현구;배정효;김대경
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.12
    • /
    • pp.602-607
    • /
    • 2003
  • We show three-dimensional distribution of voltages resulted from the leakage current originated from outdoor electrical facilities in a submerged area. In case these facilities are grounded by the neutral line multiple grounding method, the existence of ungrounded electrical facilities can cause a disastrous effect on near-by passengers. In order to investigate this situation, we installed a real-scale test field for the experiment type I (for the leakage current path between a enclosure grounded electrical facility and another enclosure grounded one), and that for the experiment type II (for the leakage current path between a enclosure grounded electrical facility and another ungrounded one). For both cases, we carried out three-dimensional monitoring of the voltage distribution while varying additional conditions such as the exposure of the underground cables and the finishing of cable connection part. The result shows that a disastrous effect on human safety can arise from the leakage current without a pertinent measure for the construction and maintenance of outdoor electrical facilities.

A Study on the Odor and Ventilation in Sludge Incineration Facilities (슬러지 소각시설 악취 및 환기에 관한 연구)

  • Seo, Byung-Suk;Jeon, Yong-Han
    • Journal of the Korea Safety Management & Science
    • /
    • v.22 no.2
    • /
    • pp.7-13
    • /
    • 2020
  • Sludge incineration facilities are socially recognized as a hate facility. Therefore, a careful deodorization plan must be established. Therefore, the incineration facility must conduct research on odor ventilation. In this study, a odor diffusion simulation in an incineration facility was conducted and analyzed. In particular, research was carried out on carry-in rooms, pre-treatment rooms, and storage facilities for crops, which are expected to rapidly spread odor. As a result, ammonia 1.62, hydrogen sulfide 0.63, and acetaldehyde 0.73 were found in the transfer room. In addition, pretreatment rooms and stencil storage facilities were found to be lower than regulatory standards.

A Study on the Prediction of Descending Smoke Time according to the Design Method of Domestic and Foreign Smoke Facilities for the Improvement of Smoke Facilities Standards in Logistics Warehouse (물류창고의 배연설비 기준 개선을 위한 국내·외 배연설비의 설계 방법에 따른 연기하강시간 예측에 관한 연구)

  • Hun, Ye-Rim;Kim, Yun-Seong;Jin, Seung-Hyun;Koo, In-Hyuk;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.141-142
    • /
    • 2022
  • Recently, fires in logistics warehouses in Korea are continuously increasing. In addition, the need for fire safety in logistics warehouses is emerging. So, it is believed that it is necessary to establish standards for vent facilities under effective smoke control for the evacuation safety of residents in logistics warehouses. Therefore, this paper compares the standards related to combustion facilities in Korea, the United States, and Japan, and applies the design method to logistics warehouses of domestic materials to predict smoke drop time and use it as a basic data for improving domestic smoke facilities standards.

  • PDF

Study on service and Use the Actual conditions of Day care Center for the elderly - with A Focus on Adult Day Care Facilities - (노인주간보호시설의 프로그램운영과 공간구성관계연구 - 경기도 노인주간보호시설을 중심으로 -)

  • Kim, Yong-Woong;Park, Kyung-Jin
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.2
    • /
    • pp.135-141
    • /
    • 2013
  • As the country's elderly people who are 65 years or older recently exceeded 10% of the total population with development of medical technology and improvement of living standards, Korea has turned into an aging society. Especially in Gyeonggi-do, as of late December 2012, elderly people who were 65 years or older were 1,135,242 persons, taking up 18.98% of the region's population and registering the largest number of elderly people in the nation's cities or provinces. Due to such a sharp rise in elderly population, support for the elderly is increasing the burden on families and communities. The study aims to take as its subjects elderly people staying at authorized elderly welfare facilities, who are weak in mind and body and have difficulty in daily life with disabilities, or adult day care facilities that take care of elderly people during the day or at night, examine the concept of adult day care facilities and instances in foreign countries, and study the status of the adult day care facilities located in Gyeonggi-do, their services, and safety by figuring out space arrangement based on program implementation. Spacial arrangement in program operation should satisfy fuction and purpose from the manager and user's perspective, and a desirable program operation should provide separate spaces for the elderly with Alzheimer's and those without Alzheimer's. Compared to residential care facilities, adult day care facilities incur less financial burden and, compared to other authorized services, have many right functions that can upgrade the quality of users and satisfy their desires. Major countries like Japan, the UK, and Sweden recognize the right functions of day and night care services and aggressively support and utilize adult day care facilities. For adult day care facilities, quality services should be developed and use and choices should be enhanced as regards services. Development of special programs for the elderly with dementia and stroke, instead of simple protective functions of a program, must be actively promoted, while manpower training is required for program operation, conveniences, and safety. By developing and providing space arrangement models that focus on efficiency, convenience, and safety of program operation, adult day care operation can be revitalized, while quality of elderly care may be enhanced and welfare budget can be saved.

An Evaluation of EOCS Regarding Safety Management Effects on Buried Gas Pipelines and Convenience of the Excavators and the Operators of Gas Companies

  • Ryon, Young-Don;Chae, Chung-Keun;Bang, Hyo-Jung;Yoon, Young-Kee;Lee, Su-Kyung
    • International Journal of Safety
    • /
    • v.6 no.2
    • /
    • pp.43-48
    • /
    • 2007
  • We introduced the Excavation One Call System (EOCS) as a pilot system, in Seoul, Korea. The system utilizes the phone and internet to transfer information about digging underground and buried gas pipelines, although currently written forms are used in accordance with the City Gas Business Law. After one year, we evaluated the business model by surveying the excavators and the operators of the gas companies. This paper shows that the EOCS was more effective in preventing the buried gas pipelines from being damaged than the existing method that has to use due form. It also shows that the EOCS was more convenient and cost efficient than the present policies in place. We come to the conclusion that the EOCS should be extended nationwide and gradually include other subsurface facilities.

- A Study on Development of Safety Diagnostic valuation of the City-gas Facilities Using AHP - (AHP를 활용한 도시가스 산업시설의 안전진단평가표 개발에 관한 연구)

  • Yang Kwang Mo;Jun Hyun Jong;Kang Kyong Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.6 no.4
    • /
    • pp.25-37
    • /
    • 2004
  • Safety diagnostic indicator pointer can divide by greatly two. One is management (Software) side that one that differ with mechanical (Hardware) side that handle laying stress on equipment connected with safety manages organization and management connected with safety. Weight appropriates according to specific gravity that relevant element occupies in facilities. To give so big value in particular element in grant of weight pays attention because break balance of whole guideline and should gives. Finally, efficient safety net may see effect before self-regulation inside by minimum target establishment using AHP by government and legal, systematic countermeasure establishment for this, strict law application and each business proprietor and though activity and user's active safety activity forms harmony properly.

A study on the analysis of actual main line systems of entertainment places (공연장내 간선설비에 대한 현장실태분석 연구)

  • Bae, S.M.;Kim, H.S.;Gil, H.J.;Yi, G.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1765-1767
    • /
    • 2003
  • The standard of living has been getting higher by reason of industrialization and economic growth. It makes people have more cultural desire(wants). Because of reasons mentioned above, a number of entertainment place and performance with high-tech is increased. This has been brought also increasing a number of electrical accident such as electrical shock, electrical fires and accidents of electrical facilities. This paper suggests technical, operational and special precautions of actual electric main line systems in entertainment places and is also written on the purpose of being applied with related provisions to designing electrical facilities, construction, check-up and inspection and maintenance for preventing further electrical disasters in entertainment places.

  • PDF