• Title/Summary/Keyword: safety facilities

Search Result 3,134, Processing Time 0.025 seconds

Study on the Status of Fire Safety Management in Elderly Welfare Facilities (노인복지시설의 소방안전관리실태에 관한 연구)

  • Ko, Wang-Youl;Hur, Man-Sung
    • Fire Science and Engineering
    • /
    • v.32 no.3
    • /
    • pp.108-115
    • /
    • 2018
  • Elderly welfare facilities are extremely susceptible to mass casualties in disastrous situations, such as fire, due to the limited physical and mental abilities of their residents. This study examined the status of fire safety management, including the structural problems of elderly welfare facilities, problems of the installation and management of firefighting systems, and problems regarding of fire safety managers. After the Sejong Medical Welfare Facility fire, these problems have been complemented by retrofitting firefighting systems in accordance with the revision of the relevant laws and regulations. On the other hand, the overall status of fire safety management is still insufficient. Therefore, it is important to improve the stability of buildings and firefighting systems as well as fire safety management through additional revision of the relevant laws and regulations.

Plan for Risk Reduction of Smart Factory Process through Accident Analysis and Status Survey (재해분석과 실태조사를 통한 스마트 팩토리 공정의 위험성 감소 방안)

  • Byeon, Junghwan
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.5
    • /
    • pp.22-32
    • /
    • 2022
  • The domestic smart factory is being built and spread rapidly, mainly by mid-sized companies and large enterprises according to the government's active introduction and support policy. But these factories only promote production system and efficiency, so harmfulness and risk factors are not considered. Therefore, to derive harmful risk factors in terms of industrial safety for 12,983 government-supported smart factory workplaces from 2014 to 2019, industrial accident status analysis compared workplaces with automation facilities and government-supported workplaces with automation facilities. Also, to reduce risks associated with domestic smart factory processes, twenty government-supported workplaces with automation facilities underwent analysis, evaluating risks through a status survey using the process evaluation table. In addition, the status survey considered region, size, industry, construction level, and accident rate; the difference in risk according to the structure of the process was confirmed. Based on the smart factory process evaluation results, statistical analysis confirmed that serial, parallel, and hybrid structures pose different risk levels and that the risks of mixed structures are greater. Finally, safety control system application was presented for risk assessment and reduction in the smart factory process, reflecting the results of disaster analysis and actual condition investigation.

A Study on User Satisfaction of Information Facilities for the Visually Impaired (시각장애인의 실내안내시설 설치 이용만족도에 관한 연구)

  • Kim, In-Bae;Kim, Won-Pil
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.26 no.2
    • /
    • pp.19-30
    • /
    • 2020
  • Purpose: The ratio of the visually impaired is gradually increasing due to various causes such as natural aging, accidents, and environmental changes. Therefore, this study has two folds. Firstly, it aims to analyze the current satisfaction level with information facilities for the visually impaired. Secondly, it aims to examine the factors affecting the satisfaction with indoor information facilities. Through this study, it helps to identify problems of information facilities for the visually impaired and it works as a practical data for further improvements. Methods: For 50 visually impaired people, a telephone survey was conducted on the satisfaction with the braille blocks, braille signboards, braille information boards with tactile map, audio guide devices, and safety egress devices. Microsoft Excel and SPSS 26.0 were used for the analysis. Results: It was confirmed that the overall satisfaction with the indoor information facilities was very low. The more the visually impaired people recognized the installation standards, and the better the maintenance was, the higher the satisfaction. In the case of braille blocks and braille signboards, the effect of information transfer on satisfaction was relatively high. In the case of audio guide device and safety egress device, the standard suitability influenced satisfaction. Implications: The low level of satisfaction with the overall information facilities can impede visually impaired people from receiving practical help through the information facilities. Factors influencing the satisfaction level of each facility were identified, which makes it possible to prepare effective improvement measures.

Risk Analysis for Installation Types of Pressure Safety Valve used in the High-pressure Gas Facility (고압가스 사용시설 내 안전밸브 설치유형별 리스크 분석)

  • Kim, Myung-Chul;Woo, Jeong-Jae;Lee, Hyung-Sub;Baek, Jong-Bae
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.4
    • /
    • pp.129-136
    • /
    • 2017
  • This study investigated the probability of possible accident through qualitative and quantitative analysis of the pressure safety valve types installed in facilities using high pressure gas to compare the installation domestic and foreign pressure safety valve standards sought the safety characteristics and safety improvement direction accordingly. The three types are the case where the shut-off valve is not installed at the front of the PSV (Case A), If a shut-off valve is installed at the front of the PSV for inspection (Case B) and If a shut-off valve is installed in front of PSV (C.S.O), PSV is installed in parallel (Case C). Three types of cases were compared with FTA and HAZOP. The results of study of the possible accidents due to over-pressure safety valve installation type, used in a high-pressure gas facilities was shows in the following order Case B > Case A > Case C. The results of analysis through FTA was in order to protect the reservoir for the possible occurring of accident the safety valve installation is depend on its type. In the FTA analysis, defects in the device itself which attached to the storage tank as a substitute for analysis of the probability of operator mistakes was Case B with as high as $2.01{\times}10^{-6}$. Depending on the type of installation analysis of Case B in order to ensure safety is prohibited to install shut-off valve and believes that mandatory regulations are needed. Rationally installing of pressure safety valve in the high pressure using facilities will be expected to improve the industrial safety from severe accidents such as high-pressure gas fire explosion.

Factors to Affect Dental Radiation Safety Management Behaviors (치과 방사선 안전관리 행위에 영향을 미치는 요인)

  • Eom, Suk;Kim, Kyung Won
    • Journal of dental hygiene science
    • /
    • v.12 no.4
    • /
    • pp.335-341
    • /
    • 2012
  • This study conducted a survey targeting at dental hygienists working in medical institutions located in Daegu, Pusan, Ulsan Metropolitan City and Gyeongnam and Gyeongbuk Province from July 18th to August 26th 2011, in order to study factors which affect radiation safety management behaviors and improve levels of those behaviors. The results of this study are as follows. 1. There were significant differences in radiation safety management knowledge of dental hygienists, according to service institutions (p<.001), the current state of defense facilities (p<.006) and the necessity for safety management education (p<.012). 2. There were significant differences in radiation safety management attitudes, according to age (p<.014), service institutions (p<.003), work experience (p<.009), educational level (p<.002), the current state of defense facilities (p<.015), the necessity for safety management education (p<.005) and the intention to take part in the education (p<.036). 3. There were significant differences in radiation safety management behaviors, depending on experience in safety management education (p<.068), measurement of exposed dose (p<.010), the state of defense facilities (p<.001). 4. There were statistically positive correlations between radiation safety management knowledge and attitude, and between radiation safety management attitude and behavior (p<.05). 5. The regular measurement of exposed dose (p<.046) and the present state of defense facilities (p<.001) were found to be factors to affect radiation safety management behaviors. In conclusion, it is considered that building perfect defense facilities of radiology rooms and measuring the exposed does of dental hygienists on a regular basis to alert them to the danger of radiation is considerably important to improve radiation safety management behaviors.

The Effects of Apartment Facility Maintenance on the Residential Satisfaction of Residents (아파트 시설물 유지관리가 입주자의 주거만족도에 미치는 영향)

  • Kim, Myung-Hee;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.3
    • /
    • pp.175-183
    • /
    • 2020
  • This study suggests a solution regarding the effects of apartment facility maintenance and fire safety facility maintenance on the residential satisfaction of residents. The results are as follows. Firstly, facility maintenance had a negative effect on residential satisfaction. Analysis revealed that residential satisfaction decreased the more breakdowns there were in the facilities. This revealed that when maintenance staff neglect the residents' complaints due to the repetitive aspect of their jobs, there was a negative effect on residential satisfaction; therefore, residential satisfaction must be increased by maintaining the facilities well and training support for maintenance staff. Secondly, fire safety facilities had a negative effect on residential satisfaction. Analysis revealed that residential satisfaction decreased the more malfunctions there were in the fire safety facilities and the more replacements there were in fire fighting equipment. This revealed the importance of safety and the fact that the apartment heavily relies on fire safety facilities because there may be a low awareness regarding safety; therefore, maintenance staff must lower the damage from fire safety facilities and to increase the residential satisafaction of residents. Lastly, there needs to be repetitive training and education for residents regarding fire fighting and evacuating in accordance with the fire fighting plan as a means to strengthen residents' safety awareness.

Development of ICT-based road safety integrated facilities for pedestrian crossing (ICT기반 횡단보도용 교통안전 통합시설물 개발)

  • Cho, Choong-Yuen;Yim, Hong-Kyu;Lee, Min-Jae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.12
    • /
    • pp.93-99
    • /
    • 2017
  • The rate of traffic accidents that occurred in Korea last year is 10 out of every 100,000 people, ranking it 6th among the 35 OECD member countries. The accident rate of children with disabilities and elderly people is also high. The purpose of this study is to introduce traffic safety facilities which have been developed for the reduction of traffic accidents in non-urban areas in Korea through an analysis of the related literature, the accident factors using traffic accident analysis system data and traffic accident characteristics. Traffic safety integrated facilities for ICT-based pedestrian crossings are subject to cross-sectional coverage of child protection zones. The smart safety fence prevents vehicles from parking illegally and informs pedestrians that there is an access vehicle on the pedestrian crossing. The smart bump is designed to warn drivers who are not aware of the pedestrians. In order to standardize the appropriate form and size of the traffic safety facilities for pedestrian crossings, we constructed a standard model for each type, considering the road function, press classification, power, lane number, geometric form, etc. As a result, the rate of traffic accidents involving vulnerable people was reduced. In addition, it is anticipated that the maintenance costs will be reduced by the use of a solar power supply and their compatibility with the existing installed safety fences.

Study on Improvement Plans for Installation and Operation of Traffic Safety Facilities according to Differences in Perception Methods and Range of Autonomous Vehicles and Human Vehicles (자율주행차량과 일반차량의 인지 방식과 범위의 차이에 따른 교통안전시설 설치 및 운영 개선방안 연구)

  • Hyeokjun Jang;Eunjeong Ko;Eum Han;Kitae Jang
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.22 no.1
    • /
    • pp.311-326
    • /
    • 2023
  • This paper proposes a plan to improve the installation and operation of traffic safety facilities using a microscopic simulation by confirming the difference in the perception method and range of autonomous vehicles and human vehicles. In this study, the existing 『Traffic Safety Sign Installation·Management Guidelines』 was reviewed, and safety signs among traffic safety facilities were classified according to changes in vehicle behavior. Subsequently, for the classified facilities, the installation location of the traffic sign was changed through simulation experiments, and the optimal location was inferred to suggest an improvement plan. This study confirmed how traffic safety facilities installed based on the visibility of human drivers affect road efficiency and safety in mixed traffic flow with autonomous vehicles and human-controlled vehicles. The optimal location derived through this study is meaningful because it can be used as the basis for revising the guidelines on the installation and management of traffic safety facilities.

A Study on the Functional Safety Analysis of PES-based Electronic Interlocking Unit according to IEC 61508 (IEC 61508 기준 PES 기반 전자연동장치의 기능 안전도 분석에 관한 연구)

  • Lee, Myung-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.11
    • /
    • pp.1526-1532
    • /
    • 2014
  • The Electronic Interlocking unit in railway signalling system is safety-related facilities to determine route and speed for train running. In particular, the SSI(Solid State Interlocking) is Electronic Interlocking unit for high-speed railway, and it performs safety-critical function by MPM(Micro-Processor Module). Meanwhile, MPM is composed of the PES(Programmable Electronic System)-based system, and the PES-based system in railway safety-related facilities should be implemented by complying with the safety requirements defined in IEC 62425 and IEC 61508. In this paper, we performed modeling of failure rate and reliability for MPM implemented by fault tolerance methods and analyzed functional safety for MPM. Moreover, we determined SIL(Safety Integrity Level) for MPM according to the safety requirements defined in IEC 61508 based on an analyzed functional safety.

A Study on the Reconfiguration in the Regulation of Electric Safety Management for the Guarantee of Safety (안전성 확보를 위한 전기안전관리기준의 재설정에 관한 연구)

  • Chung, Jae-Hee
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.6
    • /
    • pp.45-49
    • /
    • 2009
  • This study is to prepare a reasonable basis for the improvement of the electrical safety management regulation. The standards in domestic and foreign countries for the application of new and renewable energy facilities and other devices are analyzed. Other regulations excluding the electrical safety fields and wide surveys are also carried out. Consequently, it is asked that the classification between normal and self electrical facilities should be clear and deregulation for small businesses has to be followed. This study is showed that standards investigates of receiving equipment below 600V above 75kW, eletrical safety manager employment of manufacturing industry and Mid-night electric power. And, it is showed that consignment permission and Consignment inspection periodic relaxation about wind development equipment below 1,000kW, consignment of Technical Development equipment for new and renewable energy below 250kW.